This guide is for helping new customers get their Sencore VB330-Appliance setup and running as quickly and easily as possible.

The VB330-Appliance allows users to analyze up to 2000 IP compressed streams up to 20-50 Gbps total bandwidth providing IP timing analysis, stream ETR 101 290 analysis and deep content analysis.

Download the Full User's Manual

The current versions of the full user's manuals can be obtained from the Download tab of the VB330-Appliance product page on our website: www.sencore.com or by emailing Sencore ProCare support at procare@sencore.com.

Unpack the Equipment

Check that there are no signs of damage to equipment due to transport. If the equipment appears to be damaged, please contact Sencore ProCare for support.

In addition to the Sencore VB330-Appliance server hardware itself, the box should include two power cables and various rackmount hardware.

Equipment Installation and Power Up

The VB330-Appliance is designed for rack installation and should be securely connected to the rack using the included rack rails and screws suitable for the rack type. Note that there should be sufficient room for air to freely flow around the unit, ensuring proper cooling. The VB330-Appliance requires front-to-back airflow.

When the equipment is installed, it should be powered by connecting both power cables to power outlets. If one of the redundant power supplies is disconnected from power, an alarm will sound from the unit. Re-establish power to the second power supply or remove the second power supply to silence the alarm. The VB330-Appliance can operate in the range 100-240VAC.

Figure 1: IP Port Connectors

Diagram showing the IP port connectors on the VB330-Appliance, labeled as Management Port 1, Mgmt 2, Secondary Video Input, and Primary Video Input.

Establish Web Connection to the VB330-Appliance

In order to access the VB330-Appliance's web user interface, it is necessary to establish an Ethernet connection to the device. There are two alternative ways to connect to or set the device's management IP address: using the pre-set management IP address or connecting a monitor and keyboard to the server.

Using the Pre-Set Management IP Address

The Sencore VB330-Appliance is shipped with the following factory settings for management port 1:

In order to connect to management port 1, the PC used for setup should have corresponding network settings. Connect a PC directly to the device's management port using an Ethernet cable.

For Windows, the network parameters are set in the Control Panel - Network and Internet - Network and Sharing Center - Network Connection Properties - Internet Protocol Version 4 Properties view. Select the user defined address, and set the PC's IP address to 10.0.20.100 and the subnet mask to 255.255.0.0.

When the IP address of the PC has been set in the same subnet as the VB330-Appliance's factory setting, a web browser can be used to access the web user interface at 10.0.20.101 or the network settings can be edited using an SSH connection.

Figure 2: Setting the IP address manually in Windows

Screenshot showing the process of setting an IP address manually in Windows network settings.

Connecting to the VB330-Appliance Using SSH

In order to manage the VB330's IP address settings remotely or via the network connection, an SSH session must be established. Any regular SSH client can be used. One popular client, the free application PuTTY, can be downloaded from http://www.chiark.greenend.org.uk/~sgtatham/putty.

Use the VB330's default management port IP address of 10.0.20.101 (or another address if it has been changed) as the Host Name and click the OPEN button.

The default Linux login for Sencore VideoBRIDGE servers is root for the user and mpeg101 for the password. Once you are logged in, use the nmtui tool to edit the network connections.

Figure 3: SSH Connection with PuTTY

Screenshot showing the PuTTY configuration window for establishing an SSH connection.

Connecting Monitor and Keyboard to the VB330-Appliance

It is also possible to configure the network settings of the VB330-Appliance using a monitor and keyboard connected directly to the server. Once the VB330-Appliance server boots, login to Linux. The default Linux login for Sencore VideoBRIDGE servers is root for the user and mpeg101 for the password. Once you are logged in, use the nmtui tool to edit the network connections.

Editing Network Connection Settings Using nmtui

The network settings of the VB330-Appliance can be edited using various methods applicable to Linux servers. Sencore recommends the use of the graphical tool nmtui. To load the nmtui tool, type nmtui in the command line and press ENTER.

Once the nmtui tool is loaded, use it to edit a connection. There should be four connections for the VB330-Appliance. The one called Management 1 should be preset to 10.0.20.101. Edit the network settings so that they are appropriate for your network. Then save and quit nmtui and reboot the server using the reboot command to apply the new settings.

Figure 4: nmtui tool for editing network settings

Screenshot showing the nmtui tool interface for editing network settings.

Connect to the Web User Interface of the VB330-Appliance

Once the server reboots, the web user interface can be accessed using the IP address that was set for the management port. All further configuration takes place using a web browser over HTTP.

The following web browsers are supported:

Type the management IP address of the VB330-Appliance in the browser URL field and press ENTER. The web UI will be displayed.

Video Input IP Ports

The primary and secondary video IP ports on the VB330-Appliance require SFPs to connect to the customer's video network. The unit should work with any MSA compliant SFP. Customers must provide SFPs (and potentially adapters) that are compliant with their network.

The following types of SFPs are supported directly by both video IP ports:

The following types of SFPs are supported with adapters by both video IP ports:

Figure 5: QSFP to SFP+ Adapter

Image of a QSFP to SFP+ adapter.

Configuring Video Input IP Ports

The IP addresses of the primary and secondary video IP ports on the VB330-Appliance can configured using the Networking link on the Admin web UI once a web connection to the management port has been established.

http://<Management IP>/admin

The default username is root and the password is mpeg101.

Figure 6: VB330-Appliance Admin Web UI

Screenshot of the VB330-Appliance Admin Web UI.

Verify Correct Operation

Once everything is configured for analysis, the results can be viewed by clicking the Multicasts - Parameters tab. Refer to the full user manual for more details on the analysis capabilities.

Figure 7: VB330-Appliance Analysis UI

Screenshot of the VB330-Appliance Analysis UI, showing various network and stream parameters.

Define Input Streams in the VB330-Appliance

Input streams should be defined in the VB330-Appliance so that they can be monitored. The streams to be monitored are defined in the Multicasts - Streams tab in the VB330-Appliance web UI.

http://<Management IP>/probe

Support

Contact Sencore ProCare for support, if required.

Models: VB330, 50G IP Monitoring Software Probe, VB330 50G IP Monitoring Software Probe, IP Monitoring Software Probe, Software Probe, Probe

File Info : application/pdf, 4 Pages, 448.29KB

PDF preview unavailable. Download the PDF instead.

VB330-APPLIANCE-Quick-Start-Guide-v7.0-Form-8224

References

Microsoft Word for Microsoft 365

Related Documents

Preview Sencore Impulse 400D Quick Start Guide: Installation and Network Configuration
A concise guide to installing and configuring the network settings for the Sencore Impulse 400D 4K UHD Receiver/Decoder, covering package contents, physical installation, and IP address management via web interface or API.
Preview Sencore Impulse 300D Network Decoder Quick Start Guide
A quick start guide for the Sencore Impulse 300D Network Decoder, covering package contents, installation, and management.
Preview Sencore Impulse 300E Quick Start Guide
Quick start guide for the Sencore Impulse 300E Internet Streaming Encoder, covering package contents, installation, and network management.
Preview Sencore Impulse 400D Quick Start Guide
Quick start guide for the Sencore Impulse 400D 4K UHD Receiver/Decoder, covering package contents, installation, and management.
Preview Sencore AG 4800XS AtlasGear 20-Slot openGear Chassis: Features & Specifications
Explore the Sencore AG 4800XS, a 20-slot openGear chassis designed for professional video processing. Learn about its hot-swappable components, redundant power, network management, and compatible AtlasGear cards for multi-channel decoding and A/V processing.
Preview Sencore MRD 7000 Receiver Decoder Software User Manual
This user manual provides comprehensive guidance on the Sencore MRD 7000 Receiver Decoder Software, covering its features, installation, web interface operation, and technical specifications for professional broadcast and AV applications.
Preview Sencore AG6000 openGear Receiver Decoder Card | 4K UHD Broadcast Video
The Sencore AG6000 is a high-performance 4K/UHD receiver decoder card for the openGear platform, offering versatile input options including ASI, MPEG/IP, Satellite, and RF, along with advanced audio and video processing for broadcast and professional video applications.
Preview Sencore Original Replacement Leads Price List
A comprehensive price list for Sencore's original replacement leads and accessories, including part numbers, descriptions, and prices for various test leads, adapters, probes, cables, and power supplies.