Owner's Manual for BANNER models including: R50C-L-B22AOU-MQ, R50C-L-B22AOU-MQ Motor Driven Roller Controller, R50C-L-B22AOU-MQ, Motor Driven Roller Controller, Driven Roller Controller, Roller Controller, Controller

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

R50C-L-B22AOU-MQ | Convertidores

R50C-L-B22AOU-MQ Motor Driven Roller Controller ...

14 août 2024 — Efficiently control motor driven rollers from a PLC using Modbus communication. Simplify installation of multiple R50Cs on a conveyor using M12.

[PDF] R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Aug 14, 2024 · Pin 2 On Delay, One-shot, Pulse- stretcher time, or Totalizer ... Pin 2 Delay Timer 2 Upper. 0..65535. Pin 2 Off Delay or Totalizer time.


File Info : application/pdf, 18 Pages, 13.80MB

PDF preview unavailable. Download the PDF instead.

242661
R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual
Original Instructions p/n: 242661 Rev. A 14-Aug-24 © Banner Engineering Corp. All rights reserved.

Contents
Chapter 1 Features
Model ............................................................................................................................................................................................................. 3 Overview........................................................................................................................................................................................................ 3 Compatible Motor Driven Rollers................................................................................................................................................................... 4
Chapter 2 Configuration Instructions
SNAP SIGNAL® Configuration Software ...................................................................................................................................................... 5 Modbus Configuration ................................................................................................................................................................................... 5
Chapter 3 Mechanical Installation
Wiring............................................................................................................................................................................................................. 9
Chapter 4 Status Indicators...................................................................................................11 Chapter 5 Specifications
FCC Part 15 Class B for Unintentional Radiators........................................................................................................................................ 13 Industry Canada ICES-003(B)..................................................................................................................................................................... 14 Dimensions .................................................................................................................................................................................................. 14
Chapter 6 Accessories
Cordsets ...................................................................................................................................................................................................... 15
Chapter 7 Banner Engineering Corp Limited Warranty..................................................... 17
© Banner Engineering Corp. All rights reserved.

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Chapter Contents
Model.................................................................................................................................................................................................................... 3 Overview .............................................................................................................................................................................................................. 3 Compatible Motor Driven Rollers ......................................................................................................................................................................... 4

Chapter 1

Features

· Efficiently control motor driven rollers from a PLC using Modbus communication

· Simplify installation of multiple R50Cs on a conveyor using M12 connectors and motor power connections in series

· Compact bimodal to Modbus® device converter that reports and controls two channels of discrete inputs/outputs, and an analog output

voltage value (0 V DC to 18 V DC) via register settings on a Modbus

RTU server

PR

· Enabled Delay Modes: ON/OFF Delay, ON/OFF One-shot, ON/OFF/

Retriggerable One-shot, ON/OFF Pulse-stretcher and Totalizer

· Measurement Metrics: Count, Counts Per Minute (CPM), and Duration

· Discrete Mirroring: Discrete signals (In/Out) from a channel can be mirrored to the other channel's output

· Discrete input/output can be independently configured as NPN or PNP

· L-Code power pass-through

· Rugged over-molded design meets IP65, IP67, and IP68

· Connects directly to a sensor or anywhere in-line for ease of use

· R50C hubs are a quick, easy, and economical way to integrate nonModbus devices into a Modbus system

Model
Model Name
R50C-L-B22AOU-MQ

Function

Control

L-Code ports with bimodal function: 2 inputs, 2 outputs, and an analog voltage output

Modbus®

Connectors
(1) Pair of integral 5-pin M12 A-Code male/female quickdisconnect connectors
and
(1) Pair of integral 5-pin M12 L-Code male/female quick-disconnect connectors

Overview
The R50C-L-B22AOU-MQ Motor Driven Roller Controller allows for the connection to two discrete Input/Output channels, and also provides an analog voltage output control from 0 V DC to 18 V DC. This hub also supports L-Code power input/ output.
With two discrete channels that can be configured as inputs or outputs, the R50C allows for precise control over start/stop functions, direction, and error conditions. The 0­18 volt analog output ensures accurate speed control for both standard and high-speed motor driven roller systems. LED indicators provide clear status monitoring and facilitate troubleshooting, ensuring smooth and efficient operation.
The use of compact sealed M12 connectors and motor power connections in series simplifies the installation process, making it easy to set up multiple R50Cs on a conveyor. The M12 L-coded connections support higher current demands and share up to 16 amps of power, delivering more power while occupying less space than traditional connectors.

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 3 of 18

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Features

The IP67-rated fully-sealed housing and -40° C to 70° C operating range make the R50C suitable for use in challenging environments without the need for additional protective enclosures. This robustness ensures reliability and longevity in harsh conditions.

Compatible Motor Driven Rollers
The R50C is compatible with the following motor driven rollers:
· Itoh Denki PM- XE, XP · Itoh Denki PM- XC · Interoll EC310 · Interoll EC5000 · PulseRoller Senergy IDC · Lenze MDR o450 · Rulmeca BL3

page 4 of 18

© Banner Engineering Corp. All rights reserved.

14-Aug-24

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Chapter Contents
SNAP SIGNAL® Configuration Software ............................................................................................................................................................. 5 Modbus Configuration .......................................................................................................................................................................................... 5

Chapter 2

Configuration Instructions

SNAP SIGNAL® Configuration Software
The SNAP SIGNAL® Configuration Software offers an easy way to manage converter Modbus® settings, retrieve data, and visually show converter data. The SNAP SIGNAL Configuration Software runs on any Windows machine and uses an adapter cable (BWA-UCT-900, p/n 19970) to connect the converter to the computer.
Download the most recent version of the SNAP SIGNAL Configuration Software from the Banner Engineering website: https://www.bannerengineering.com/sg/en/products/software/snap-signal-configuration-software.html.

Modbus Configuration

Device Port States

Modbus Register Address
40001
40002

Description
Pin 4 - Channel 1 Pin 2 - Channel 2

I/O range

Comments

0..1

Black wire discrete output

0..1

White wire discrete output

Default
0 0

Access

Notes

RW

0 = Inactive, 1 = Active

RW

0 = Inactive, 1 = Active

Analog Out Value

Modbus Register Address
40003

Description Pin 5 - Analog Out

I/O range

Comments

0..10200

Voltage = mV

Default

Access

Notes

0

RW

Max. Voltage = 18000 mV

Port Configuration

Modbus Register Address
40004
40005
40006

Description

I/O range

Comments

Default

Access

Notes

Pin 4 IO Selection

0..5

Pin 2 IO Selection

0..5

L-Code Auxiliary Power Status

0..1

0 = NPN Input
1 = PNP Input
2 = NPN Output with Pull Up 3
3 = PNP Output with Pull Down
4 = NPN Output Push Pull
5 = PNP Output Push Pull
0 = NPN Input
1 = PNP Input
2 = NPN Output with Pull Up 3
3 = PNP Output with Pull Down
4 = NPN Output Push Pull
5 = PNP Output Push Pull

0 = Off, 1 = On

-

RW

PNP output

RW

PNP output

RO

APwr LED Status

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 5 of 18

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Configuration Instructions

Modbus Configuration

Modbus Register Address
40601
40602
40603 40604 40605

Description

I/O range

Comments

Baud Rate
Parity Address Reserved (cannot be read or written) Restore Factory Configuration

0 = 9.6k 1 = 19.2k 2 = 38.4k 0 = None 1 = Odd 2 = Even 1-254 None 0 = No Operation, 1 = Restore

0 = 9.600 1 = 19200 2 = 38400 0 = None 1 = Odd 2 = Even -

Default

Access

1

RW

0

RW

1

RW

-

-

-

WO

Device Information

Modbus Register Address
40606-40615
40616-40631
40632
40633 40634 40635 40636 40637
40644-40659
40680 40681 40682 40683 40684

Description

I/O range

Comments

Default

Access

Notes

Banner Name

0..65535

Product Name

0..65535

Item H

0..65535

Item L Serial Number H Serial Number Serial Number Serial Number L

0..65535 0..65535 0..65535 0..65535 0..65535

User Define Tag

0..65535

Discovery

0..1

All-Time Run Time H 0..65535

All-Time Run Time L 0..65535

Resettable Run Time H 0..65535

Resettable Run Time L 0..65535

-

Banner Engineering

RO

-

R50C-LB22AOU-MQ

RO

816907 split into two 16-bit registers

12

RO

-

30475

RO

-

-

RO

-

-

RO

-

-

RO

-

-

RO

User Writable Space

More Sensors. More Solutions.

RW

0 = Disabled, 1 = Enabled -

RW

-

-

RO

-

-

RO

-

-

RW

-

-

RW

(9 words/18 Characters)
(16 words/32 Characters)
Banner Item Number Serial Number is split into (4) 16-bit registers (16 words/32 Characters) Flash all LEDs to find hub Upper 16 of 32 bits Lower 16 of 32 bits Upper 16 of 32 bits Lower 16 of 32 bits

Measurement Reads

Modbus Register Address

Description

41001

Pin 4 Active State

41002

Pin 2 Active State

I/O Range

Comments

0..1

0 = Inactive, 1 = Active

-

0..1

0 = Inactive, 1 = Active

-

41003

Pin 4 Count H

0..65535

Pin 4 Count Value Upper

-

Default

41004

Pin 4 Count L

0..65535

Pin 4 Count Value Lower

-

Continued on page 7

Access

Notes

RO

-

RO

-

Upper 16 of 32 bits = Running

RO

count of the received input

pulses

Lower 16 of 32 bits = Running

RO

count of the received input

pulses

page 6 of 18

© Banner Engineering Corp. All rights reserved.

14-Aug-24

Configuration Instructions

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Modbus Register Address

Description

I/O Range

Continued from page 6

Comments

Default

41005

Pin 4 Duration H 0..65535

Pin 4 Duration Value Upper

-

41006
41007
41008 41009 41010 41011 41012 41013

Pin 4 Duration L

0..65535

Pin 4 Duration Value Lower

-

Pin 4 Events Per Minute H

0..65535

Pin 4 Events Per Minute L

0..65535

Pin 4 Totalizer Count H
Pin 4 Totalizer Count L

0..65535 0..65535

Pin 2 Count H

0..65535

Pin 2 Count L

0..65535

Pin 4 Events Per

Minute Value

-

Upper

Pin 4 Events Per

Minute Value

-

Lower

Pin 4 Totalizer Count Upper

-

Pin 4 Totalizer Count Lower

-

Pin 2 Count Value Upper

-

Pin 2 Count Value Lower

-

Pin 2 Duration H 0..65535

Pin 2 Duration Value Upper

-

41014

Pin 2 Duration L

0..65535

Pin 2 Duration Value Lower

-

41015

Pin 2 Events Per Minute H

0..65535

Pin 2 Events Per

Minute Value

-

Upper

41016 41017 41018

Pin 2 Events Per Minute L

0..65535

Pin 2 Totalizer Count H
Pin 2 Totalizer Count L

0..65535 0..65535

Pin 2 Events Per

Minute Value

-

Lower

Pin 2 Totalizer Count Upper

-

Pin 2 Totalizer Count Lower

-

Metric Count Presets

Modbus Register Address

Description

41100

Pin 4 Count H

41101

Pin 4 Count L

41102

Pin 2 Count H

41103

Pin 2 Count L

I/O Range

Comments

0..65535

Pin 4 Count Value Upper

-

0..65535

Pin 4 Count Value Lower

-

0..65535

Pin 2 Count Value Upper

-

0..65535

Pin 2 Count Value Lower

-

Default

Access

Notes

Upper 16 of 32 bits =

RO

Duration of the last input pulse in µs with 50 µs

granularity

Lower 16 of 32 bits =

RO

Duration of the last input pulse in µs with 50 µs

granularity

Upper 16 of 32 bits = Running

RO

count of the number of pulses received averaged over one

minute. Range 1 to 37,500

Lower 16 of 32 bits = Running

RO

count of the number of pulses received averaged over one

minute. Range 1 to 37,500

RO

Upper 16 of 32 bits = Totalizer count

RO

Lower 16 of 32 bits = Totalizer count

Upper 16 of 32 bits = Running

RO

count of the received input

pulses

Lower 16 of 32 bits = Running

RO

count of the received input

pulses

Upper 16 of 32 bits =

RO

Duration of the last input pulse in µs with 50 µs

granularity

Lower 16 of 32 bits =

RO

Duration of the last input pulse in µs with 50 µs

granularity

Upper 16 of 32 bits = Running

RO

count of the number of pulses received averaged over one

minute. Range 1 to 37,500

Lower 16 of 32 bits = Running

RO

count of the number of pulses received averaged over one

minute. Range 1 to 37,500

RO

Upper 16 of 32 bits = Totalizer count

RO

Lower 16 of 32 bits = Totalizer count

Access

Notes

RW

Upper 16 of 32 bits

RW

Lower 16 of 32 bits

RW

Upper 16 of 32 bits

RW

Lower 16 of 32 bits

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 7 of 18

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Configuration Instructions

Pin 4 Port Configuration (Black - Female, Discrete 1)

Modbus Register Address

Description

41201

Pin 4 Mode

41202
41203
41204 41205 41206 41207

Pin 4 Delay Timer 1 Upper
Pin 4 Delay Timer 1 Lower
Pin 4 Delay Timer 2 Upper Pin 4 Delay Timer 2 Lower Pin 4 Mirroring Enable Pin 4 Mirroring Inversion

I/O Range

Comments

Default Access

Notes

0 = Disabled

1 = On Off Delay

2 = On One-shot

3 = Off One-shot

0..8

4 = On Pulse-stretcher

0

RW

5 = Off Pulse-stretcher

6 = Totalizer

7 = Retriggerable On One-shot

8 = Retriggerable Off One-shot

0..65535

Pin 4 On Delay, One-shot, Pulsestretcher time, Totalizer Count

0

RW

0..65535

Pin 4 On Delay, One-shot, Pulsestretcher time, Totalizer Count

0

RW

0..65535

Pin 4 Off Delay or Totalizer time 0

RW

0..65535

Pin 4 Off Delay or Totalizer time 0

RW

0..1

0 = Disabled, 1 = Enabled

0

RW

0..1

0 = Not inverted, 1 = Inverted

0

RW

-
Upper 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Lower 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Upper 16 of 32 Bits = Milliseconds Lower 16 of 32 Bits = Milliseconds Enable mirroring of Pin 2 input Invert Pin 2 input state

Pin 2 Port Configuration (White - Female, Discrete 2)

Modbus Register Address

Description

41301

Pin 2 Mode

41302
41303
41304 41305 41306 41307

Pin 2 Delay Timer 1 Upper
Pin 2 Delay Timer 1 Lower
Pin 2 Delay Timer 2 Upper Pin 2 Delay Timer 2 Lower Pin 2 Mirroring Enable Pin 2 Mirroring Inversion

I/O Range

Comments

Default Access

Notes

0 = Disabled

1 = On Off Delay

2 = On One-shot

3 = Off One-shot

0..6

4 = On Pulse-stretcher

0

RW

5 = Off Pulse-stretcher

6 = Totalizer

7 = Retriggerable On One-shot

8 = Retriggerable Off One-shot

0..65535

Pin 2 On Delay, One-shot, Pulsestretcher time, or Totalizer Count

0

RW

0..65535

Pin 2 On Delay, One-shot, Pulsestretcher time, or Totalizer Count

0

RW

0..65535 Pin 2 Off Delay or Totalizer time 0

RW

0..65535 Pin 2 Off Delay or Totalizer time 0

RW

0..1

0 = Disabled, 1 = Enabled

0

RW

0..1

0 = Not Inverted, 1 = Inverted

0

RW

-
Upper 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Lower 16 of 32 Bits: Mode 1, 2, 3, 4, 5, 7, 8 = Milliseconds Mode 6 = Count Upper 16 of 32 Bits = Milliseconds Lower 16 of 32 Bits = Milliseconds Enable mirror of Pin 4 input Invert Pin 4 input state

page 8 of 18

© Banner Engineering Corp. All rights reserved.

14-Aug-24

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Chapter Contents Wiring ................................................................................................................................................................................................................... 9

Chapter 3

Mechanical Installation

Install the R50C to allow access for functional checks, maintenance, and service or replacement. Do not install the R50C in such a way to allow for intentional defeat. Fasteners must be of sufficient strength to guard against breakage. The use of permanent fasteners or locking hardware is recommended to prevent the loosening or displacement of the device. The mounting hole (4.5 mm) in the R50C accepts M4 (#8) hardware.
See the figure below to help in determining the minimum screw length.

18.0 mm

X 3 mm *

Screw Length = 18.0 mm + "X" mm + 3 mm

* for minimum engagement of three threads

CAUTION: Do not overtighten the R50C's mounting screw during installation. Overtightening can affect the performance of the R50C.

Wiring

A-Code Male and Female Pinouts

Modbus - Male

Pin

1
1

2

2

4

3

3

5

4

5

Motor Driven Roller (MDR) - Female

Pin

1

2

1

2

3

3

4

5

4

5

12 V DC to 30 V DC RS485/D1/B+ GND RS485/D0/ABannerBus

Signal Description

12 V DC to 30 V DC Channel 2 GND Channel 1 Analog Out

Signal Description

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 9 of 18

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

L-Code Male and Female Pinouts (16A)

Male Pinout

Female Pinout

Pin

5

1

4

5

1

4

12

3

2

33

24

5

Mechanical Installation

Wire Color Brown White Blue Black Gray

+24 V DC GND GND +24 V DC FE

Signal Description

page 10 of 18

© Banner Engineering Corp. All rights reserved.

14-Aug-24

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Chapter Contents
Chapter 4

Status Indicators

The R50C has matching LED indicators on both sides of the converter to allow for installation needs, while still providing adequate indication visibility.
There are two pairs of green LEDS: · PWR: A-Code power indication · APwr: L-Code power indication
Additionally, there are four pairs of amber LEDs: · C: Modbus communications · AO: Analog Out · D1: Discrete Channel 1 (Pin 4) · D2: Discrete Channel 2 (Pin 2)

R50C-L-B22AOU-MQ 12-30 V dc 50 mA

PWR C

C PWR

R50C-L-B22AOU-MQ 12-30 V dc 50 mA

APwr AO D1 D2

front

A-Code Power Indicator Green LEDs

Off Solid Green

Indication

L-Code Power Indicator Green LEDs

Off Solid Green

Indication

Modbus Communications Amber LEDs

Indication Off Flashing Amber (4 Hz) Solid Amber for 2 seconds, then off
Solid Amber for 2 seconds, then to flashing amber (4 Hz)

D2 D1 AO APwr
back

Power off Power on

Status

L-Code power is off or not attached L-Code power is on or active

Status

Status Modbus communications are not present Modbus communications are active Modbus communications are lost after connection Modbus communications are momentarily lost, but then communication is reestablished

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 11 of 18

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Status Indicators

Analog Out Amber LEDs

Off Solid Amber

Indication

Discrete Channel 1 and Discrete Channel 2 Amber LEDs

Off Solid Amber

Indication

Status Analog output value is outside the allowable output range (0 V DC to 18 V DC) Analog output value is inside the allowable output range (0 V DC to 18 V DC)

Discrete is inactive Discrete is active

Status

page 12 of 18

© Banner Engineering Corp. All rights reserved.

14-Aug-24

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Chapter Contents
FCC Part 15 Class B for Unintentional Radiators .............................................................................................................................................. 13 Industry Canada ICES-003(B)............................................................................................................................................................................ 14 Dimensions......................................................................................................................................................................................................... 14

Chapter 5

Specifications

Supply Voltage 12 V DC to 30 V DC at 400 mA maximum
Power Pass-Through Current 16 A maximum
Discrete Output Load Rating 200 mA
Analog Output Load Requirements Resistance > 1000 
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Leakage Current Immunity 400 µA
Indicators See Status Indicators
Connections (1) Integral 5-pin M12 A-Code female quickdisconnect connector (1) Integral 5-pin M12 A-Code male quickdisconnect connector (1) Integral 5-pin M12 L-Code female quickdisconnect connector (1) Integral 5-pin M12 L-Code male quickdisconnect connector
Construction Coupling Material: Nickel-plated brass Connector Body: PVC translucent black
Vibration and Mechanical Shock Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5 minutes sweep, 30 minutes dwell) Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave)
Certifications
Banner Engineering BV Park Lane, Culliganlaan 2F bus 3 1831 Diegem, BELGIUM
Turck Banner LTD Blenheim House Blenheim Court Wickford, Essex SS11 8YT GREAT BRITAIN

Product Identification

Environmental Rating IP65, IP67, IP68
Operating Conditions Temperature: ­40 °C to +70 °C (­40 °F to +158 °F) 90% at +70 °C maximum relative humidity (non-condensing) Storage Temperature: ­40 °C to +80 °C (­40 °F to +176 °F)
Required Overcurrent Protection

WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.

Overcurrent protection is required to be provided by end product application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.

Supply Wiring (AWG)
20
22
24

Required Overcurrent Protection (A)
5.0 3.0 1.0

Supply Wiring (AWG)
26
28
30

Required Overcurrent Protection (A)
1.0 0.8 0.5

FCC Part 15 Class B for Unintentional Radiators
(Part 15.105(b)) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 13 of 18

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Specifications

(Part 15.21) Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

Industry Canada ICES-003(B)
This device complies with CAN ICES-3 (B)/NMB-3(B). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la norme NMB-3(B). Le fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne peut pas occasionner d'interférences, et (2) il doit tolérer toute interférence, y compris celles susceptibles de provoquer un fonctionnement non souhaité du dispositif.

Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change.

M12 x 1.0

M12 x 1.0

M12 x 1.0

M12 x 1.0

page 14 of 18

© Banner Engineering Corp. All rights reserved.

14-Aug-24

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Chapter Contents Cordsets ............................................................................................................................................................................................................. 15

Chapter 6

Accessories

A-Code connectivity accessories are listed below. For L-Code connectivity accessories, please reach out to Banner Application Support at 1-888-3-SENSOR (736767).

Cordsets

Model BC-M12F4-M12M4-22-1 BC-M12F4-M12M4-22-2 BC-M12F4-M12M4-22-5 BC-M12F4-M12M4-22-8 BC-M12F4-M12M4-22-10
BC-M12F4-M12M4-22-15

4-pin Double-Ended M12 Female to M12 Male Cordsets

Length

Dimensions (mm)

Pinouts

1 m (3.28 ft) 2 m (6.56 ft) 5 m (16.4 ft) 8 m (26.25 ft) 10 m (30.81 ft)
15 m (49.2 ft)

40 Typ. [1.58"]
M12 x 1 ø 14.5 [0.57"] 44 Typ. [1.73"]
M12 x 1 ø 14.5 [0.57"]

Female 2
1 3
4
Male
1 2
4 3

1 = Brown 2 = White 3 = Blue 4 = Black

Model BC-M12F4-M12M4A-22-1 BC-M12F4-M12M4A-22-2 BC-M12F4-M12M4A-22-5 BC-M12F4-M12M4A-22-8 BC-M12F4-M12M4A-22-10
BC-M12F4-M12M4A-22-15

4-pin Double-Ended M12 Female to M12 Male Right-Angle Cordsets

Length

Dimensions (mm)

Pinouts

1 m (3.28 ft) 2 m (6.56 ft) 5 m (16.4 ft) 8 m (26.25 ft) 10 m (30.81 ft)
15 m (49.2 ft)

32 Typ. [1.26"]
30 Typ. [1.18"]

M12 x 1 ø 14.5 [0.57"]
44 Typ. [1.73"]

ø 14.5 [0.57"] M12 x 1

Female 2
1 3
4
Male
1 2
4 3

1 = Brown 2 = White 3 = Blue 4 = Black

Model BC-M12F4A-M12M4A-22-1 BC-M12F4A-M12M4A-22-2 BC-M12F4A-M12M4A-22-5 BC-M12F4A-M12M4A-22-8 BC-M12F4A-M12M4A-22-10
BC-M12F4A-M12M4A-22-15

4-pin Double-Ended M12 Female Right-Angle to M12 Male Right-Angle Cordsets

Length

Dimensions (mm)

Pinouts

1 m (3.28 ft) 2 m (6.56 ft) 5 m (16.4 ft) 8 m (26.25 ft) 10 m (30.81 ft)
15 m (49.2 ft)

32 Typ. [1.26"]
30 Typ. [1.18"]

Female
2 1
3 4

M12 x 1 ø 14.5 [0.57"]

Male
31 Typ.
1 2

32 Typ.

4 3

1 = Brown 2 = White 3 = Blue 4 = Black

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 15 of 18

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Model

4-Pin M12 Female RS-485 to USB Adapter Cordset, with Wall Plug

Length

Style

Dimensions

BWA-UCT-900

1 m (3.28 ft)

Straight

Accessories

Pinout (Female)

2

4

1

3

1 = Brown 2 = White 3 = Blue 4 = Black

page 16 of 18

© Banner Engineering Corp. All rights reserved.

14-Aug-24

R50C-L-B22AOU-MQ Motor Driven Roller Controller Product Manual

Chapter Contents
Chapter 7

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.
THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.
For patent information, see www.bannerengineering.com/patents.

14-Aug-24

© Banner Engineering Corp. All rights reserved.

page 17 of 18

LinkedIn X (formerly Twitter) Facebook
© 2024. All rights reserved. www.bannerengineering.com



References