D313928-A ~10436180.ai

emily.haarmann

For 80 and 90 Single Stage Furnaces

MG2R | Gas Furnace | Maytag | Literature Library

MG2R | Gas Furnace | Unbranded | Literature Library

MG2R | Gas Furnace | Miller | Literature Library

PDF preview unavailable. Download the PDF instead.

10436180
COM X T4 T3 T2 T1
EAC-H
120V HUM-H
CIRC-H
XFRM-H
LINE-H

WIRING DIAGRAM

For 80+ and 90+ Single Stage Furnaces

Refer to the Installation Instructions provided with the furnace for the proper heating and cooling speeds for your application.

Red LED Flash Error/Condition

Flash codes stored in memory (auto-erased after 14 days)

1

System Lockout (Retries Exceeded)

2

Pressure Switch Stuck Closed

3

Pressure Switch Stuck Open

4

Open High Temperature Limit Switch

5

Flame Sensed>4.25 Seconds with Gas Valve De-Energized

6

Open Flame RO Switch

8

Ignitor Relay Error

10

Open Fuse

11

Ignitor Open

12

Inducer Relay Error

Flash codes NOT stored in memory

7

Low Flame Sense Signal

9

Twinning Fault

Control Failure / No Power / Internal Fault / IRQ Loss

Off

Gas Heating Lockout (Gas valve energized when it should be de-energized)

Or Gas valve De-energized when it should be Energized

Rapid Flash Reverse Polarity

Continuous On Normal Operation

PRESSURE SWITCH

ORANGE

SUPPLY AIR LIMIT

ORANGE BLUE

BLUE W/ WH STRIPE

VENT LIMIT

FLAME ROLLOUT

If any of the original wire as supplied with the furnace must be replaced, it must be replaced with wiring material having a temperature of at least 105 C.
Use copper conductors only.

GREEN

FLAME SENSOR RED

GAS VALVE

YELLOW YELLOW

Motor SPEED
Cool

Cool Motor SPEED DIPSWITCH SETTING (S1-1, S1-2, S1-3) 123 123 123 123 123 123 123 123 Position OFF OFF OFF ON OFF OFF ON ON OFF OFF ON OFF OFF OFF ON OFF ON ON ON OFF ON ON ON ON

Y

T1

T2

T3

T4

T1+T2

T1

T1

T1

Heat Motor SPEED DIPSWITCH SETTING (S2-1, S2-2)

12 12 12 12

Position OFF OFF ON OFF ON ON OFF ON

Motor

SPEED W

T1

T2

T3

T4

Heat

Fan Motor SPEED DIPSWITCH SETTING (S2-3, S2-4)

12 12 12 12

Position OFF OFF ON OFF OFF ON ON ON

Motor

SPEED G

T1

T2

T4

T1+T2

Fan

1 1 WHITE
2 2 BLK W/ WHITE STRIPES IGNITOR

GREEN

R

C

INDUCER

11

22

BLUE BLUE

WHITE BLACK

WHITE

WHITE

BLUE

BLK W/ WHITE STRIPES

BLACK WHITE

24 V WHITE W/ BLK STRIPES

120 V

1234 1234

LINE-N XFMR-N CIRC-N 120V HUM-N EAC-N IND-N IGN-N

321 654 987 12 11 10

Y/ DHUM Y Y1 Y2 W R G C

LEGEND:
FIELD WIRING LOW VOLTAGE HIGH VOLTAGE

GREEN

WHITE BLACK

BLACK

DOOR SWITCH

BLUE BLUE

MOTOR

1 2 3 4 5 N L CG

GREEN

NOTE: FOR BLOWER
WIRING SEE BLOWER TABLE
LITERATURE

RED ORANGE
BLUE BLACK WHITE BLACK GRAY

123456789 123456789

RED ORANGE
BLUE
BLACK WHITE

BLACK GRAY

BLOWER DECK LIMIT

10436180 (New)
06/22

