Instructions for ARROW models including: DLX-35541-VPSC Pressure Injectable One Lumen PICC pre Loaded, DLX-35541-VPSC, Pressure Injectable One Lumen PICC pre Loaded, Injectable One Lumen PICC pre Loaded, PICC pre Loaded

linux, amd64

[PDF] Pressure Injectable One-Lumen PICC pre-loaded with Arrow VPS ...www.teleflexvascular.com › lidstock

DLX-35541-VPSC - Teleflex Incorporated - Vascular Access Product Catalog

PDF preview unavailable. Download the PDF instead.

LBL072343
PB-10000-850 8.5 X 10.5

DLX-35541-VPSC (IPNXXXXXX)

4 1 Fr.

Lumen

55 cm catheter length

.018 inch dia. spring-wire guide

Pressure Injectable One-Lumen PICC pre-loaded with Arrow® VPS PrecisionTM Stylet

Contents:
1: One Lumen TaperFree® Catheter: 4 Fr. (1.45 mm OD) x 55 cm, Pressure Injectable, Contamination Guard, Arrow® VPS PrecisionTM Stylet and TuohyBorst Adapter 
1: GlideThruTM Peel-Away Sheath: 4 Fr. x 2-3/4" (7 cm) Radiopaque over 4 Fr. Dilator 
1: Spring-Wire Guide, Nitinol, Marked: .018" (0.46 mm) dia. x 17-3/4" (45 cm) (Straight Soft Tip on One End - Straight Stiff Tip on Other) with Arrow Advancer 
1: Stiffening Stylet (0.36mm dia. x 75cm with straight distal tip)  1: Injection Needle: SafetyGlideTM1 25 Ga. x 5/8" (1.60 cm)  1: Safety Introducer Needle: Echogenic 21 Ga. x 2-3/4" (7 cm) TW  1: Blunt Fill Needle: 18 Ga. x 1-1/2" (3.81 cm)  1: Introducer Needle: Echogenic 21 Ga. x 2-3/4" (7 cm) TW  1: Syringe: 5 mL Luer-Lock  4: 10 mL Luer-Lock Pre-Filled Saline Syringe  1: 5 mL 1% Lidocaine HCl Solution and Alcohol Prep  1: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution  2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with
Hi-Lite OrangeTM Tint  1: Dust Cap: Non-Vented  1: SharpsAway® II Locking Disposal Cup  1: SharpsAway® Disposal Cup  1: Catheter Trimmer  1: Towel: 24" x 36" (61 cm x 91 cm)  1: Maximal Barrier DrapeTM with two 13 cm (5") x 15 cm (6") fenestrations  1: Safety Scalpel: #11  1: Sterile Procedure Sign  1: Patient ID Card 

1: Patient Information Booklet  1: Medication Label: 1% Lidocaine  2: Paper Tape Measure  1: Tourniquet  1: Foam Electrodes (3 per pack)  10: Gauze Pad: 2" x 2" (5 cm x 5 cm)  10: Gauze Pad: 4" x 4" (10 cm x 10 cm)  1: Surgical Apparel: Impervious Gown  1: Dressing: Tegaderm®3 CHG 3-1/2" x 4-1/2" (8.5 cm x 11.5 cm)  1: Transducer Cover with Gel and Rubber Bands  1: Surgical Apparel: Mask with Eye Shield  1: Dressing: STATLOCK®4 PICC Plus Catheter Stabilization Device  1: Surgical Apparel: Bouffant Cap  1: Surgical Apparel: Mask  1: Tape: Steri-Strip®3 
1A trademark of Becton, Dickinson and Company. 2A registered trademark of CareFusion or one of its subsidiaries. 3A registered trademark of 3M Company. 4A registered trademark of C. R. Bard, Inc.

MR Safe Not made with natural rubber latex. Store between 20 ­ 25°C (68 ­ 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication.
Contraindications: The Pressure Injectable PICC is contraindicated wherever there is presence of device related infections or presence of thrombosis in the intended insertion vessel or catheter pathway. Clinical assessment of the patient must be completed to ensure no contraindications exist.

Lumen Pink (17 Ga.)

Priming Volume*
(mL) 0.63

Gravity Flow Rate
(mL/hr) 970

Pump Flow Rate
(mL/hr) 5300

MAX Pressure Injection
Flow Rate** (mL/sec) 5

* Priming volumes are approximate and are done without accessories.  Flow rate values are approximate and are determined using deionized water at 100 cm head height.  Pump flow rates are determined at maximum pump pressure of 10 psig and represent approximate flow capabilities. ** Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.


CAS # 7440-48-4

LBL072343 R01 (2024-04)

