EV Charging Station Manual
Model: F-MBZ1
Introduction
This manual provides comprehensive information for the Feyree EV Charging Station, designed to meet the needs of electric vehicle owners. It covers features, installation, operation, safety precautions, and troubleshooting.
A white electric vehicle is connected to a wall-mounted EV charging station. The charging station has a carbon fiber-like texture and a digital display.
Standard Compliance: Charging plug meets SAE J1772 standard. Control box meets IEC 61851 control principle.
Operating Temperature: -30°C to 55°C.
It is recommended to read the instructions before use.
Features
- Charging plug meets SAE J1772 standard.
- Control box meets IEC 61851 control principle.
- Excellent protection performance, protection grade IP65.
- Operating temperature: -30°C to 55°C.
Mechanical Properties
- Mechanical life: No-load plug in/pull out > 10000 times.
- Impact of external force: Can afford 1m drop and 2T vehicle run over pressure.
Control Box Function
- Leakage protection (restart recovery).
- Over voltage/under-voltage protection (self-checking recovery).
- Lightning protection.
- Over current protection.
- Overheat protection.
- Ground protection.
Appearance Dimension
Dimensions of the charging station: width 161mm, depth 86mm, height 310mm.
Width: 161mm
Depth: 86mm
Height: 310mm
Product Structure
Outline drawings showing the front, side, back, and angled views of the Feyree EV charging station.
The product structure includes the main unit with a display screen, buttons, and charging port.
Charger Cord Specification
- 7.6KW: 3G6mm² + 1*0.5mm²
- 9.6KW: 3G8mm² + 2*0.5mm²
- 12KW: 3G10mm² + 2*0.5mm²
Electric Performance
Rated voltage, current, and power:
- 85V-264V AC, 8A-10A-13A-16A-32A / 7.6KW
- 85V-264V AC, 13A-16A-25A-32A-40A / 9.6KW
- 85V-264V AC, 13A-16A-25A-32A-40A-50A / 12KW
- Insulation Resistance: >1000MΩ (DC500V)
- Terminal Temperature Rise: < 50K
Cautions
- Do not bring dangerous items such as flammable, explosive, or combustible materials, chemicals, flammable steam, etc. near the charging pile.
- Keep the charging gun head clean and dry. If it is dirty, wipe it with a clean dry cloth. It is strictly forbidden to touch the charging gun core with your hands when it is charged.
- It is strictly forbidden to use the charging pile when the charging gun or charging cable is defective, cracked, worn, broken, or the charging cable is exposed. If you find any, please contact the staff in time.
- Do not attempt to disassemble, repair, or modify the charging pile. If there is a need for maintenance or modification, please contact the staff. Improper operation may cause damage to the equipment, water leakage, etc.
- If there is any abnormality during use, press the emergency stop button ? immediately to cut off all input and output power supplies.
- In case of rain and thunder, please charge carefully ⛈️.
- Children are not allowed to approach or use the charging pile during the charging process to avoid injury.
- During the charging process, the vehicle is prohibited from driving and can be charged only when it is stationary. Please turn off the hybrid electric car before charging.
- Do not use the device in extreme temperatures (normal operating range: -30°C to 55°C).
Installation Process
Diagram illustrating wall mounting points for the charging station, with vertical measurements of 1100mm and 1280mm from a floor line. Another diagram shows the gun base installation at 800mm from the ground.
Illustration of the installed charging station on a brick wall, connected to a vehicle.
- Wiring and installing the wall bracket:
- Wall-mounted installation and fixing: Hang the mounting holes on the back of the device into the fixing screws on the wall from the front, and fix them.
- Installation of gun base: Just below the equipment, install the gun base. The installation height is 800mm from the ground.
The installation is over, the effect is as follows:
Power-on Inspection and Debugging
1) Check before operation
Before running, please check carefully and ensure the following items:
- The installation position of the AC pile is convenient for operation and maintenance.
- The AC pile and accessories are correctly connected and installed firmly.
- Reasonable selection of leakage protection switch for AC inlet.
- No external objects or parts are left on the top of the AC pile.
2) Power on the device
- Make sure that the above inspection items before operation meet the requirements.
- Close the power inlet leakage protection circuit breaker.
- Power on the AC pile: There is about 5 seconds of power-on self-check time, and the green indicator light flashes.
- After the power-on self-check is completed, observe the status of the LED indicator.
Normal standby: The green light is always on.
Equipment failure: Red light is always on.
LED Screen Description
Detailed diagram of the charging station's LED screen. It displays: Time (00:00:00), Temperature (30°C), Voltage (223V), Current (0.0A), Power (0.0kW), Energy (0.0kWh), Status (Ready), Set Current (32A), Delay Time (D:01h), Charge Time (T:00h). It also shows icons for Timer, Wifi State, and Energy.
Screen Elements:
- Time: 00:00:00
- Temperature: 30°C
- Voltage: 223V
- Current: 0.0A
- Power: 0.0kW
- Energy: 0.0kWh
- Status: Ready
- Set Current: 32A
- Delay Time (D): 01h
- Charge Time (T): 00h
- [Timer Icon]
- [Wifi State Icon]
- [Energy Icon]
Set Delaytime
| Serial Number | Status | Green LED | Blue LED | Red LED | Definition Description |
|---|---|---|---|---|---|
| 1 | Ready | On | Off | Off | Power-on self-test or reset |
| 2 | Connect | Flash | Off | Off | The voltage of detection point 1 is 9±0.8V. |
| 3 | Charging | Off | Breathe | Off | Detection point 1 voltage is 6±0.8V, the relay is closed. |
| 4 | Finish | Off | On | Off | Charging complete. |
| 5 | Err:CP | Off | Off | Fault (0.5s) 1 time | Electrical disconnection. |
| 6 | Under Voltage | Off | Off | Fault (0.5s) 2 time | 1 phase: voltage < 85V; 3 phase: voltage < 147V. |
| 7 | Over Voltage | Off | Off | Fault (0.5s) 3 time | 1 phase: voltage > 264V; 3 phase: voltage > 457V. |
| 8 | Elec Leakage | Off | Off | Fault (0.5s) 4 time | The relay is disconnected, and it needs to be re-powered after the fault is removed before the relay is allowed to close. |
| 9 | Over Current | Off | Off | Fault (0.5s) 5 time | When the line current is Ie+2 < I ≤ Ie+4, 60S, the relay is disconnected, and it will automatically restart after 10S. Repeat three times for permanent disconnection. When I > Ie+4, the relay is disconnected, and the charging ends. |
| 10 | Over Temp | Off | Off | Fault (0.5s) 6 time | Temperature > 85 degrees, disconnect the relay, wait for the temperature < 65 degrees, then turn on charging. |
| 11 | Ungrounded | Off | Off | Fault (0.5s) 7 time | The ground wire is not connected, the relay is disconnected, and the relay is allowed to close after the fault is removed. |
How to use RFID card?
Image of the Feyree EV charging station with an RFID card placed on its sensing area.
- When the RFID function is cancelled by the charging pile, the charging gun can be directly inserted into the car charging base for charging.
- When the RFID function is turned on, just put the RFID card in the sensing position and start charging, and then you can take away the RFID card.
- If you want to end charging, you can place the RFID card in the sensing position again and end charging after a short delay.
- If you want to continue charging, you must pull out the charging gun or press the emergency stop button ?, then reset, and put the RFID card at the sensing position again to continue charging.
How to cancel RFID card
Image of the Feyree EV charging station with annotations indicating to press a specific area for 10 seconds to disable RFID, followed by a screen showing "Disable RFID".
- Press this place for 10 seconds.
- "Disable RFID" appears on the screen, swipe the card and cancels successfully.
If you want to continue using the RFID card, just repeat the above operation.
Troubleshooting
Fault display screens showing error messages like "Err:CP", "Under Voltage", and "Elec Leakage", along with relevant voltage/current readings and warning icons.
(1) Err:cp (abnormal connection of charging gun)
Fault display:
Err:CP [Warning Icon]
Troubleshooting:
- Check whether the connection of the charging gun is correct and reliable.
- If the fault still exists, please contact us.
(2) Under Voltage (AC input voltage too low)
Fault display:
Under Voltage [Warning Icon]
Troubleshooting:
- Use a multimeter to measure the actual input voltage of the equipment.
- If the actual voltage is lower than 85V for a short time, please wait for the power grid to recover to the normal range.
- If the actual voltage is less than 85V AC for a long time, please contact the power supply department.
- If the actual voltage is greater than 85V AC, please contact us.
(3) Elec Leakage (Leakage current greater than 30mA)
Fault display:
Elec Leakage [Warning Icon]
Troubleshooting:
- Immediately disconnect the leakage / overcurrent protection switch of the distribution box ?.
- Check whether the AC pile output line is damaged or has low impedance connection to the ground.
- After the above problems are eliminated, power on again. If the fault still exists, please contact us.
Warranty
Damage caused for the following reasons is not covered by the warranty:
- Improper handling, installation, use, and maintenance by the user.
- Product falls into the water.
This warranty is for the original purchaser only and is NOT transferable.