User Guide for RENISHAW models including: RMI-QE, RMIQE, KQGRMI-QE, KQGRMIQE, RMI-QE Radio Machine Probe, Radio Machine Probe, Machine Probe, Probe

User manual

Renishaw plc RMI-QE RMI-QE Radio Machine Interface KQGRMI-QE KQGRMIQE rmi qe

download (pdf)

RMI-QE Rmi Qe Radio Machine Interface by Renishaw plc

PDF preview unavailable. Download the PDF instead.

RMI-QE-Users-Manual-Renishaw-plc-kqgrmi-qe-ex-1-10
Quick-start guide H-6551-8520-RTA
RMI-QE

EN DE ES FR IT 
Issued: xx.xxxx

Publications for this product are available by scanning the barcode or visiting www.renishaw.com/rmi-qe.
Für dieses Produkt stehen weitere Informationen zur Verfügung. Scannen Sie dazu den Barcode oder besuchen Sie
www.renishaw.de/rmi-qe.
Para acceder a las publicaciones sobre este producto escanee el código de barras o visite www.renishaw.es/rmi-qe.
Les documentations pour ce produit sont disponibles en scannant le code barres ou en visitant www.renishaw.fr/rmi-qe.
Le pubblicazioni relative a questo prodotto sono disponibili scansionando il codice a lato oppure visitando il sito: www.renishaw.it/rmi-qe.
 www.renishaw.jp/rmi-qe 

PL
CS
RU
 ()  () 

Dostp do dokumentacji tego produktu mona uzyska, skanujc kod kreskowy lub odwiedzajc witryn www.renishaw.pl/rmi-qe.
Publikace pro tento produkt jsou k dispozici po naskenování QR kódu nebo na stránce www.renishaw.cz/rmi-qe.
      ,  -    www.renishaw.ru/rmi-qe.
 
www.renishaw.com.tw/rmi-qe
  www.renishaw.com.cn/rmi-qe
         
www.renishaw.co.kr/rmi-qe.

Safety
Information to the machine supplier/installer
It is the machine supplier's responsibility to ensure that the user is made aware of any hazards involved during operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards and safety interlocks are provided.
If the probe fails, the probe signal may falsely indicate a probe seated condition. Do not rely on probe signals to halt the movement of the machine.
Information to the equipment installer
All Renishaw equipment is designed to comply with the relevant EU and FCC regulatory requirements. It is the responsibility of the equipment installer to ensure that the following guidelines are adhered to, in order for the product to function in accordance with these regulations:
· Any interface MUST be installed in a position away from any potential sources of electrical noise (for example, power transformers, servo drives).
· All 0 V/ground connections should be connected to the machine "star point" (the "star point" is a single point return for all equipment ground and screen cables). This is very important and failure to adhere to this can cause a potential difference between grounds.
· All screens must be connected as outlined in the user instructions. · Cables must not be routed alongside high current sources (for example, motor power supply cables), or be near high-speed data
lines. · Cable lengths should always be kept to a minimum.
Equipment operation
If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

Switch settings SW1 and SW2

Factory settings shown are for: · A-6551-0049 · A-6551-0050
SW1

Abbreviations are as follows: · NO = Normally open · NC = Normally closed · NH = Normally high · NL = Normally low
SW2

Switch SW1 output configuration Switch SW2 output configuration

PROBE

STATUS 1

Pulsed

NO

LOW BATTERY
NO

ERROR NO

PROBE

STATUS 2a/2b

Pulsed

NH

MACHINE

START

Level

Dedicated start

Seated start on

`Fast' turn on

ON

Level

NC

NC

NC

Level

NL

Pulsed Common Seated `Standard'

start

start off turn on

CAUTION: Exercise caution when using error or probe SSR in NO mode as a wiring fault could cause loss of error

condition and therefore could result in a non-failsafe condition.

5

Wiring diagram (with output groupings shown)

RMI-QE

Turquoise
Turquoise/black Violet
Violet/black Green
Green/black White

Probe status 1 (SSR) Low battery (SSR) Error (SSR) Machine start input [P1]

Pink

Machine start input [P2] (see note)

White/red

Machine start input [P3] (see note)

5 V Driver
Driver 12 V to 30 V
0 V Screen

White/blue

Brown

Yellow Grey
Orange
Red (see note)

Signal Return

Black Green/yellow

Machine start input [P4] (see note) Machine start return Probe status 2a (5 V isolated driven skip) Probe status 2b
Power supply (12 V to 30 V)
Machine ground ("star point")

CAUTION: The power supply 0 V should be terminated at the machine ground ("star point"). A negative supply can be used, when wired appropriately.
NOTE: A switch can be fitted between the machine power supply and the red wire, to aid powering up the RMI-QE when partnering.
6

RMI-QE visual diagnostics

LOW BATTERY/START LED

Off

Battery is okay

and no M-code

start/stop in

progress

Battery low

M-code start/ stop in progress
Battery low and M-code start/ stop in progress
Overload error

PROBE STATUS LED Probe triggered
Probe seated
System error See installation guide Overload error

P1, P2, P3, P4 SYSTEM STATUS LEDs

Off

Probe number empty

Probe number full, in standby

Probe number full, operating

System error See installation guide

Selection error

Partnering/clearing pending, probe full

Partnering pending, probe empty

Partnering complete, probe full

Probe authentication error

Clearing complete, probe empty

KEY TO THE SYMBOLS Continuously on Flashing

SIGNAL LED

Off

No probes

operating

Good communications

Poor communications

Overload error

ERROR LED

Off

No error

Error

System error See installation guide
Overload error
7

This page is intentionally left blank.
8

© 2021 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw plc. Renishaw plc. Registered in England and Wales. Company no: 1106260. Registered office: New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR, UK.
Disclaimer WHILE CONSIDERABLE EFFORT WAS MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT PUBLICATION, ALL WARRANTIES, CONDITIONS, REPRESENTATIONS AND LIABILITY, HOWSOEVER ARISING, ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW. RENISHAW RESERVES THE RIGHT TO MAKE CHANGES TO THIS DOCUMENT AND TO THE EQUIPMENT, AND/OR SOFTWARE AND THE SPECIFICATION DESCRIBED HEREIN WITHOUT OBLIGATION TO PROVIDE NOTICE OF SUCH CHANGES.
Trade marks RENISHAW® and the probe symbol are registered trade marks of Renishaw plc. Renishaw product names, designations and the mark `apply innovation' are trade marks of Renishaw plc or its subsidiaries. Other brand, product or company names are trade marks of their respective owners.
Warranty Unless you and Renishaw have agreed and signed a separate written agreement, the equipment and/or software are sold subject to the Renishaw Standard Terms and Conditions supplied with such equipment and/or software, or available on request from your local Renishaw office. Renishaw warrants its equipment and software for a limited period (as set out in the Standard Terms and Conditions), provided that they are installed and used exactly as defined in associated Renishaw documentation. You should consult these Standard Terms and Conditions to find out the full details ofyour warranty. Equipment and/or software purchased by you from a third-party supplier is subject to separate terms and conditions supplied with such equipment and/or software. You should contact your third-party supplier for details.
9

EU declaration of conformity

C

Renishaw plc hereby declares that the RMI-QE is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.
Contact Renishaw plc or visit www.renishaw.com/mtpdoc for the full EU declaration of conformity.

Disposal of waste electrical and electronic equipment (WEEE)

The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service or Renishaw distributor.
Disposal of batteries
The use of this symbol on the batteries, packaging or accompanying documents indicates that used batteries should not be mixed with general household waste. Dispose of the used batteries at a designated collection point. This will prevent potential negative effects on the environment and human health which could otherwise arise from inappropriate waste handling. Contact your local authority or waste disposal service concerning the separate collection and disposal of batteries. All lithium and rechargeable batteries must be fully discharged or protected from short circuiting prior to disposal.
10

REACH regulation Information required by Article 33(1) of Regulation (EC) No. 1907/2006 ("REACH") relating to products containing substances of very high concern (SVHCs) is available at: www.renishaw.com/REACH
China RoHS For more information on China RoHS visit: www.renishaw.com/chinarohs
FCC Information to user (USA only) 47 CFR Section 15.19 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. 47 CFR Section 15.21 The user is cautioned that any changes or modifications not expressly approved by Renishaw plc or authorised representative could void the user's authority to operate the equipment.
ICES Information to user (Canada only) This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme ICES-001 du Canada
11

Patents
Features of RMIQE and features of similar products are the subject of one or more of the following patents and/ or patent applications: Patents pending
12

 288 181 200436 T +86 21 6180 6416 F +86 21 6180 6418 E shanghai@renishaw.com
www.renishaw.com.cn

/
 


EUFCC  ·  · 0/""
 ·  ·  · 


13

Radio approvals
Canada: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1)l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
14

15

Renishaw plc
New Mills, Wotton-under-Edge Gloucestershire, GL12 8JR United Kingdom

T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com
www.renishaw.com

For worldwide contact details, visit www.renishaw.com/contact
*H-6551-8520-01*


Adobe PDF Library 15.0 Adobe InDesign 16.1 (Windows)