Nortek Global HVAC E7 Series Electric Furnaces

Technical Specifications

Product Overview

The E7 Series furnace is designed for all sizes of manufactured and modular homes, incorporating reliability and low maintenance. Units can be installed free-standing in a utility room or enclosed in an alcove or closet. E7 Series furnaces are A/C ready, with 16 blower speeds to meet any cooling requirement.

Available Models:

Features and Benefits

Model Identification

The model number is structured as follows:

E7E*-0**H1

Furnace Parts Identification

Diagram showing key components of the furnace:

Unit Specifications

FURNACE MODELS E7- 010H 012H 015H 017H 020H 023H
Rated Heating Output, Btuh (see note 1) 35,000 41,000 53,000 57,000 70,000 75,000
Watts (Total kw, Heating Elements & Blower) 10.4 12.0 15.4 16.6 20.4 22.0
Supply Voltage 240 Volts/60Hz/1-Phase
Heating Elements, No. (Total kw) 2 (10.0) 2 (11.6) 3 (15.0) 3 (16.2) 4 (20.0) 4 (21.6)
Motor Speed, H.P. Rating, Amps 16 Speed, 1/2 HP, 3.6 A
Test ESP, in. w.c. Max 0.3
Optional Cooling Available with factory installed blower 2.0-4.0 Ton
Optional Heat Pump Available with factory installed blower 2.0-4.0 Ton
Air Filter (Standard) 18" x 20" x 1" (nominal)
Furnace Dimensions Upflow/Downflow: Width-20" (508mm), Height-29" (737mm), Depth-24 1/2" (623mm) Multipose: Width-20" (508mm), Height-60 5/8" (1546mm), Depth-24 1/2" (623mm)

Note 1: Heating output rated at listed voltage. For outputs at voltages other than 240V, multiply Btuh rating by the following factors: x 0.92 (230V), x 0.84 (220V), x 0.75 (208V)

Electrical Specifications

MODEL NUMBER E7E*- SUPPLY CIRCUIT AMPERES TOTAL AMPERES MAXIMUM OVER-CURRENT RATING MINIMUM CIRCUIT AMPACITY
010H1 Single 45.3 60 57 57
012H1 Single 51.6 70 65 65
012H1 Dual "A" 27.8 35 35 35
012H1 Dual "B" 24.2 35 30 30
015H1 Single 66.1 90 83 83
015H1 Dual "A" 45.3 60 57 57
015H1 Dual "B" 20.8 30 26 26
017H1 Single 71.1 90 89 89
017H1 Dual "A" 45.0 60 56 56
017H1 Dual "B" 26.1 35 33 33
020H1 Single 86.9 110 109 109
020H1 Dual "A" 45.3 60 57 57
020H1 Dual "B" 41.7 60 52 52
023H1 Single 93.6 125 117 117
023H1 Dual "A" 45.3 60 57 57
023H1 Dual "B" 48.0 60 60 60

NOTE: Wire size must be in accordance with the applicable revision of the NEC and all other applicable codes.

Anticipator Settings

Furnace Model Thermostat Anticipator Setting
010, 012 0.2
015, 017, 020, 023 0.4

Clearances

ALL MODELS CLOSET ALCOVE
Front ‡ 6" 18" 18"
Back 0" 0" 0"
Sides 0"† 0"† 0"†
Top 0" 0" 0"
Top and Sides of Duct 0" 0" 0"
Bottom of Duct 0" 0" 0"

‡ Service Clearance

† For upflow application using upflow stand, 1" minimum per side.

E7EM Physical Dimensions

Diagram showing physical dimensions for the E7EM model:

E7EU & E7ED Physical Dimensions

Diagram showing physical dimensions for the E7EU and E7ED models:

E7 Furnace Upflow Stand Dimensions

Diagram showing dimensions for the E7 Furnace Upflow Stand.

Optional Accessories

Available Coil Cabinets

Coil Box Dimension A Width (mm) Dimension B Depth (mm) Dimension C Height (mm)
1006730 20" (508mm) 24" (610mm) 31.5" (802mm)
1006731 20" (508mm) 24" (610mm) 31.5" (802mm)
904067 20" (508mm) 24" (610mm) 27" (686mm)
902976 20" (508mm) 24" (610mm) 29" (736mm)

Accessories List

Description Part Number
Blower, 5 Ton 1027059
Heating Thermostat Intertherm (12 Pac) 903188 (903182)
Heating Thermostat Miller (12 Pac) 903189 (903183)
Thermostat Sub-Base 914146
Heating/Cooling Thermostat CM65 Intertherm/Miller (12 Pac) 903992 (903993)
Heating/Cooling Thermostat GE Intertherm (12 Pac) 903192 (903186)
Heating/Cooling Thermostat GE Miller (12 Pac) 903193 (903187)
Automatic Damper for AC or HP Package Unit 901083
"VEE" Box Adapters (10") - 5 / carton 901985
Duct Connector 10" Dia. x 6" Long - 6 / carton 902926
"VEE" Box Adapters (12") - 5 / carton 902149
Single Wide Fitting Kit (12") 911468A
Double Wide Fitting Kit (12") 911469A
Single Wide Fitting Kit (14") 914957
Double Wide Fitting Kit (14") 914956
Y-Fitting (12") 911470
Y-Fitting (14") 917195
Fan Delay Kit (TDR) 911758
Top Grille/Frame 902989
Top Grille/Frame (4 pack) 903000
Cabinet to Combine w/ Grille/Frame 903891
Upflow Stand 1014501
Coil Cabinet (For all sizes), Upflow & Downflow w/ Solid Door 1006730
Coil Cabinet (For all sizes), Upflow & Downflow w/ Louvered Door 1006731
Coil Cabinet Downflow (Front return) 904067
Coil Cabinet Upflow (Solid door, limited capacities) 902976

Accessory Kits

Vent Kits

Description Part Number
Soffit Air Inlet (for VentilAire III only) 917201A
VentilAire III - Sloped 3/12 914098
VentilAire IV - Sloped 3/12 914229
VentilAire V - Sloped 3/12 1018547

Plenum Connectors

Dimensions Quantity / Carton Part Number
11.25 x 13.50 x 0.88 12 / carton 901987A
11.25 x 13.50 x 2.00 12 / carton 901988A
11.25 x 13.50 x 4.25 6 / carton 901989A
11.25 x 13.50 x 6.25 6 / carton 901990A
11.25 x 13.50 x 8.25 4 / carton 901991A
11.25 x 13.50 x 10.25 3 / carton 901992A
11.25 x 13.50 x 12.25 3 / carton 901993A
11.25 x 13.50 x 6.25 24 / carton 902681A

Airflow Data

Airflow (CFM) vs. External Static Pressure (In. W.C.)

MODEL NUMBER MOTOR SWITCH SETTINGS (0=OFF, 1=ON) EXTERNAL STATIC PRESSURE (IN. W.C.)
1/5 2/6 3/7 4/8 0.1 0.2 0.3 0.4 0.5 0.6
CFM CFM CFM CFM CFM CFM CFM CFM CFM CFM
0 0 0 0 685 640 606 560 513 460
1 0 0 0 770 727 692 648 599 552
0 1 0 0 854 815 779 737 685 645
1 1 0 0 939 902 865 825 771 737
0 0 1 0 1,012 974 938 899 850 813
1 0 1 0 1,084 1,047 1,011 973 930 888
0 1 1 0 1,157 1,119 1,084 1,047 1,009 964
1 1 1 0 1,197 1,166 1,130 1,093 1,056 1,017
E7E*-0**H1 0 0 0 1 1,245 1,215 1,178 1,143 1,105 1,066
1 0 0 1 1,293 1,263 1,225 1,192 1,154 1,114
0 1 0 1 1,344 1,312 1,278 1,242 1,206 1,169
1 1 0 1 1,394 1,361 1,330 1,291 1,257 1,223
0 0 1 1 1,434 1,401 1,369 1,332 1,299 1,267
1 0 1 1 1,473 1,441 1,408 1,373 1,340 1,311
0 1 1 1 1,514 1,483 1,451 1,417 1,386 1,355
1 1 1 1 1,555 1,525 1,494 1,460 1,431 1,398

NOTES:

1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, and 4. For cooling speeds use COOL switches 5, 6, 7, and 8.

2. Data is shown with filter.

Maximum Heating Airflow Setting

E7E*-0**H1 E7EM E7ED E7EU
DOWNFLOW UPFLOW DOWNFLOW UPFLOW DOWNFLOW UPFLOW
MH RES MH RES MH RES MH RES MH RES MH RES
10 0101 0001
12 0011
15 0101 0101 0101 0001 0101 0101 0101
17 0101
20 0011 0001 0011 0001 0011
23

NOTES:

1. MH and Res represent Manufactured Housing and Residential (modular home) applications, respectively.

2. To comply with government mandated efficiency standards, speed settings with higher CFM values than listed in this table are not allowed in HEAT mode.

General Terms of Limited Warranty

For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (07/2019)

Models: E7 Series Electric Furnace, E7 Series, Electric Furnace, Furnace

File Info : application/pdf, 12 Pages, 639.31KB

PDF preview unavailable. Download the PDF instead.

492f

References

TCPDF 6.0.003 (http://www.tcpdf.org)

Related Documents

Preview E7 Series Electric Furnaces: Technical Specifications, Features, and Accessories
Comprehensive technical specifications, features, benefits, model identification, electrical data, physical dimensions, airflow data, and accessories for the E7 Series Electric Furnaces manufactured by Nortek Global HVAC.
Preview E3EB-xxx-H Series Electric Furnaces: Technical Specifications and Features
Detailed technical specifications, model identification, features, benefits, accessories, and airflow data for the E3EB-xxx-H Series Downflow, Upflow Electric Furnaces by Nortek Global HVAC.
Preview E7 Series Electric Furnace Installation Instructions
Comprehensive installation instructions for the E7 Series Electric Furnace, covering downflow and upflow models. Includes safety information, requirements, electrical wiring, start-up procedures, and model identification.
Preview High Airflow Blower Kit Installation Instructions for E7 Furnaces
Installation instructions for the Nortek Global HVAC High Airflow Blower Kit designed to increase airflow for cooling in E7 series electric furnaces. Includes safety warnings, step-by-step installation guide, and technical data tables.
Preview Nortek Global HVAC E7 Series Electric Furnace Replacement Parts List
Comprehensive replacement parts list for Nortek Global HVAC E7 Series electric furnaces, covering models -010, -012, -015, -017, -020, and -023. Includes part numbers for blower motors, control boards, elements, filters, doors, and more.
Preview Nortek Global HVAC M5S Series Installation Instructions
Installation guide for Nortek Global HVAC M5S Series forced air oil furnaces, suitable for manufactured homes and recreational vehicles. Covers safety, requirements, installation, electrical, fuel, startup, and maintenance.
Preview Nortek Global HVAC G8SA Series Gas Furnace Technical Specifications
Detailed technical specifications and features for the Nortek Global HVAC G8SA Series single-stage upflow/horizontal gas furnaces, including ultra-low NOx emissions, AFUE ratings, dimensions, and airflow data.
Preview MG2S Series Downflow Condensing Gas Furnace User Manual
User manual for the MG2S Series Downflow Condensing Gas Furnace, covering safe operation, installation, maintenance, and troubleshooting for high-efficiency heating in manufactured homes and RVs.