BROMIC REFRIGERATION

Confidence and control.

INSTRUCTION MANUAL

SINGLE DOOR UNDER BENCH FRIDGES & FREEZERS

Model Numbers: 3736254, 3736255, 3736256

Revision: 1 | Date: 7/08/2023

1. PREFIX

This manual contains important information about the installation, operation, and maintenance of Bromic under bench cabinets. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols:

[DANGER], [WARNING], [IMPORTANT]

2. IMPORTANT NOTES AND WARNINGS

3. PRODUCT OVERVIEW

Part Number UBC0140SD-NR UBC0140GD-NR UBF0140SD-NR
3736254 3736255 3736256
Height, mm 885 885 885
Width, mm 650 650 650
Depth, mm 650 650 650
Capacity, Litres 145 145 145
Air Circulation Type Fan Forced Fan Forced Fan Forced
Climate Class Rating 3 3 3
Maximum Ambient Temperature, Degrees Celsius 32°C 32°C 32°C
Temperature Range 1°C to 5°C 1°C to 5°C 1°C to 5°C
Temperature Type Digital Digital Analogue
Door Material Solid Glass Solid
Door Type Hinged Hinged Hinged
Door Lock Yes Yes Yes
Voltage, V 240 240 240
Frequency, Hz 50 50 50
Current, A 1.2 1.2 1.2
Power, W 280 280 280
Power Consumption kWh/24h 1.26 1.1 1.65
Refrigerant R600a R600a R600a
Charge, g 32 32 38
Internal Light Type LED LED LED
Internal Light Qty 2 2 2
Plug Rating 10A 10A 10A
Wheels Type Castors Castors Castors
Wheels Quantity 4 4 4

4. INSTALLATION

Locating the Cabinet

Ensure the following instructions are observed as this is vital for proper and trouble-free operation.

Diagram illustrating proper ventilation clearances around the appliance, showing airflow arrows and recommended distances from walls.

Ventilation

NOTE: The maximum ambient temperature for the refrigerator is 30°C. Conditions outside this temperature will result in cabinet temperatures outside the required 2 to 8°C range. Bromic recommends that the refrigerator is installed at an ambient temperature of 20 to 25°C.

Power Supply

Diagram illustrating correct power connection: a 3-pin plug connected to an earthed socket, with a crossed-out image of a multi-outlet power board.

Before Operating

5. OPERATION

Start-up

NOTE: The Cooling Light is illuminated when the appliance is chilling the interior of the cabinet.

Manual Defrost

This cabinet features automatic defrost. However, should the appliance require an additional defrost, press SET and hold the DEFROST button for 6 seconds. Automatic defrost cycles occur every 8 hours and last 20 minutes (factory default). To stop the Defrost, press SET and hold the DEFROST button for 6 seconds.

Setting the temperature

  1. Press the [SET button].
  2. The value of the set point will be displayed and the display will flash.
  3. Press the [UP/DOWN arrow button] within 6 seconds to adjust the set point.
  4. Press the [SET button] again or wait 6 seconds.

Image of a digital temperature controller with display and buttons labeled SET, UP, and DOWN.

6. PRODUCT LOADING AND STORAGE

IMPORTANT: Run the refrigerator for at least 2 hours before loading.

WARNING: Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance.

Start-up Loading

NOTE: Bromic cannot be responsible for loss of stock or damage to stock.

7. MAINTENANCE

WARNING: Disconnect the appliance from the power supply before performing any maintenance. Never unplug the appliance by pulling on the cord. Always grasp the plug firmly and pull straight out of the outlet.

WARNING: Exposure to significant water ingress will void warranty and cause potential safety issues. If the unit should be exposed to water, please contact the manufacturer immediately.

IMPORTANT: Warranty may be void if there is no evidence of preventative maintenance is performed on the appliance.

Cleaning the Cabinet

Condenser Coil/Filter

IMPORTANT: The filter and the condenser coil must be cleaned once a month. The filter can be removed for cleaning with water, make sure it is dried before reattaching. The condenser coil must be cleaned with vacuum/brush monthly to maintain the performance and minimise power consumption. A poorly maintained condenser coil can lead to failure of the unit and higher cabinet temperatures.

8. TROUBLESHOOTING

IMPORTANT: Repairs on the unit must be carried out by an authorised and licensed person only. Contact the manufacturer or an approved service agent for any repairs needed.

Symptom Possible Cause(s) Possible Solution(s)
Fridge does not turn on A. No power supply A. i. Check that switch is on
ii. Try plugging cabinet into different power sockets
iii. Check power plug and cord for damage
Fridge temperature too high A. Incorrect controller set point
B. Ambient temperature too high
C. Inadequate ventilation
D. Dirty condenser unit
E. Ice build-up on evaporator coil
A. Change controller set point
B. Ensure unit is in an air-conditioned environment of 25C
C. Keep ventilation slots clear
Fridge temperature too low A. Incorrect controller set point
B. Ambient temperature too low
C. Faulty evaporator probe
A. Change controller set point
B. Ensure unit is in a temperature-controlled environment of 25C
C. Contact Bromic service
Fridge temperature greatly fluctuating A. Cabinet is in direct sunlight or outdoors A. Reposition cabinet such that it is not in direct sunlight or outdoors
Fridge leaving water puddles on the ground A. Cabinet glass is condensing and dripping
B. Cabinet drip tray is overflowing
A. Ensure the cabinet is in an air-conditioned environment of 25C and 60% RH
B. Contact Bromic service for diagnosis
No display on controller A. No power supply A. Check power supply
B. Contact Bromic customer service
Odour inside Fridge A. Rotting odour inside cabinet
B. Oil or smokey odour
A. Clean the cabinet
B. Turn off the cabinet and contact Bromic service immediately

10. ENVIRONMENTAL AND DISPOSAL NOTES

These refrigerated cabinets are designed to high standards of environmental protection and recycling convenience. Cyclopentane, an environmentally friendly foaming agent, has been used. Cyclopentane is distinguished by zero ozone depletion potential (ODP) and zero global warming potential (GWP). The refrigerant used and contained within a hermetically tight circuit is environmentally friendly and does not contain chlorine and zero ODP.

The device must be disposed of in accordance with applicable regulations. The WEEE regulations must be observed.

In the interest of preventing environmental nuisance and promoting re-use of the high quality materials employed, used commercial refrigeration equipment must be collected for expert disposal and recycling. Therefore, observe the following disposal regulations:

11. WARRANTY

All Bromic products are manufactured to the highest quality standard and are supported by our Extra Care Service Warranty, including guarantees against any material or workmanship defects; guarantees that cannot be excluded under Australian Consumer Law.

Warranty Terms vary across the range. Please ensure you are familiar with the Terms and Conditions that apply to the purchase of your Bromic product by referring to the Warranty Policy included with your purchased product.

Alternatively, you can also download the Warranty Policy at https://bromicrefrigeration.com.au/extra-care-warranty.

HOW TO PLACE A SERVICE REQUEST

Diagram of a compliance plate showing model details, serial number, electrical specifications, and certifications (e.g., [CE Mark], [ACE Mark]).

Service Request Priority

[Priority A]: When the unit is NOT performing its primary function such as cooling or heating, or presents an OH&S or food safety risk.

[Priority B]: When the unit is performing its primary function, and presents no OH&S or food safety risk. i.e. lights, gaskets, locks, door adjustment.

Service Call Timing

SERVICE CALL PLACED BEFORE MIDDAY

Priority A - Technician to attend site within 4 hours

Priority B - Technician to attend site within 8 business hours

SERVICE CALL PLACED AFTER MIDDAY

Priority A - Technician attends site before midday on the following business day

Priority B - Technician attends site before 4pm on the following business day

Models: UBC0140SD-NR Single Door Under Bench Fridges And Freezers, UBC0140SD-NR, Single Door Under Bench Fridges And Freezers, Door Under Bench Fridges And Freezers, Under Bench Fridges And Freezers, Bench Fridges And Freezers, Fridges And Freezers, And Freezers

File Info : application/pdf, 16 Pages, 1.26MB

PDF preview unavailable. Download the PDF instead.

User-Manual Under-Bench 0823 Finals web

References

Adobe PDF Library 17.0 Adobe InDesign 18.2 (Windows)

Related Documents

Preview Bromic Chest Freezer Instruction Manual: Installation, Operation, and Maintenance
Comprehensive instruction manual for Bromic chest freezers, covering installation, operation, maintenance, troubleshooting, and warranty information. Includes product specifications for various models.
Preview Bromic UBC2230SD-NR Under Bench Fridge - 553L Stainless Steel
Detailed specifications and features of the Bromic UBC2230SD-NR, a 553L, 4-door stainless steel under-bench fridge and freezer, designed for commercial use with energy efficiency and robust performance.
Preview Bromic Vertical Display Fridges Instruction Manual
This instruction manual provides detailed information on the installation, operation, maintenance, and troubleshooting of Bromic Vertical Display Fridges, including models 3736219, 3736222, and 3735048-NR. It covers safety precautions, product specifications, and warranty information.
Preview Bromic SVM1875HD-NR Semi Vertical Display Fridge - 1875mm, 4 Doors
Discover the Bromic SVM1875HD-NR, a 1875mm semi-vertical display fridge with 4 hinged doors. Featuring high-impact LED lighting, R290 refrigerant, and a 9-star GEMS rating for energy efficiency. Ideal for commercial display of perishable goods.
Preview Bromic Back Bar Display Fridges Instruction Manual - Installation, Operation & Maintenance
Official instruction manual for Bromic Back Bar Display Fridges (models 3736070-1 to 3736074-1). Provides detailed guidance on installation, operation, product loading, maintenance, troubleshooting, environmental notes, and warranty information.
Preview Bromic BB0200GD-NR-1 Back Bar Fridge - 190L, 2 Doors
Detailed specifications and features of the Bromic BB0200GD-NR-1 Back Bar Fridge, a 190L, 2-door hinged unit designed for commercial use. Highlights include LED lighting, digital temperature control, and a durable design.
Preview Bromic MED0140GD-NR Medical and Vaccine Fridge Instruction Manual
Comprehensive instruction manual for the Bromic MED0140GD-NR Medical and Vaccine Fridge, covering installation, operation, maintenance, troubleshooting, and safety guidelines.
Preview Bromic IM0065SSC Self-Contained Solid Cube Ice Machine - 59kg/24h Production
Explore the Bromic IM0065SSC, a robust self-contained solid cube ice machine designed for commercial use. It offers 59kg of ice production per 24 hours and a 30kg storage capacity. Key features include durable stainless steel construction, efficient cooling, Agion® antimicrobial protection, and compliance with Australian safety standards. View detailed specifications, dimensions, and warranty information.