Instruction Manual for dandb audiotechnik models including: xD40D, xD40D Amplifier, Amplifier
Version 1.8: Milan™ version. General information. 40D Start-up manual. Version: 1.8 en, 05/2025, D2036.
2 giorni fa — device, this manual covers the basic safety instructions as well as the vital technical specifications and instructions for startup. A full version of this ...
File Info : application/pdf, 26 Pages, 2.75MB
DocumentDocumentxD40D Start-up manual 1.8 en Notes on document version All previous versions of this document are hereby no longer valid. Version 1.8: MilanTM version. General information 40D Start-up manual Version: 1.8 en, 05/2025, D2036.EN .01 Copyright © 2025 by d&b audiotechnik GmbH & Co. KG; all rights reserved. Keep this document with the product or in a safe place so that it is available for future reference. We recommend you to regularly check the d&b website for the latest version of this document. When reselling this product, hand over this document to the new owner. If you supply d&b products, please draw the attention of your customers to this document. Enclose the relevant documents with the systems. If you require additional documents for this purpose, you can order them from d&b. d&b audiotechnik GmbH & Co. KG Eugen-Adolff-Str. 134, D-71522 Backnang, Germany T +49-7191-9669-0, F +49-7191-95 00 00 docadmin@dbaudio.com, www.dbaudio.com IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Explanation of graphical symbols The lightning symbol within a triangle is intended to alert the user to the presence of uninsulated "dangerous voltages" within the unit's chassis that may be of sufficient magnitude to constitute a risk of electric shock to humans. Before using this product, carefully read the applicable items of the following safety instructions. 1. Keep these instructions for future reference. 2. Read these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. WARNING! To reduce the risk of fire or electric shock: Do not expose this unit to rain or moisture. Keep water or other liquids away from the unit. Do not place liquid filled containers, for example beverages, on top of the unit. Do not operate the unit while it is wet or standing in liquid. 6. Always operate the unit with the chassis ground wire connected to the electrical safety earth. Do not defeat the safety purpose of a grounding-type plug. A grounding-type plug has two blades and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 7. Do not use this unit if the power cord is damaged or frayed. Protect the power cord from being walked upon or pinched, particularly at the plugs and the point where it exits from the apparatus. 8. The unit is intended for use in a 19" rack. Follow the mounting instructions. When a rack on wheels is used, exercise caution when moving the loaded rack to avoid injury from tipping over. 9. Unplug this apparatus during lightning storms or when unused for long periods of time. The exclamation point within a triangle is intended to alert the user to the presence of important operating and service instructions in the literature accompanying the product. 10. Never connect an output pin to any other amplifier input or output pin or to the earth (ground). This may damage the unit or lead to electric shock. 11. Lay all cables connected to the unit carefully so that they cannot be crushed by vehicles or other equipment and that no one can either step on them or trip over them. 12. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way such as: Power-supply cord or plug is damaged. Liquid has been spilled into the unit. An object has fallen into the unit. The unit has been exposed to rain or moisture. The unit does not operate normally. The unit was dropped or the chassis is damaged. Do not remove top or bottom covers. Removal of the covers will expose hazardous voltages. There are no user serviceable parts inside and removal may void the warranty. 13. Use the mains plug as the disconnecting device and keep it readily accessible. If the mains plug is not readily accessible due to mounting in a 19" equipment cabinet, then the mains plug for the entire rack must be readily accessible. 14. An experienced user must always supervise the equipment, especially if inexperienced adults or minors are using the equipment. d&b 40D Start-up manual 1.8 en 3 WARNINGS! To prevent electric shock do not remove top or bottom covers. No user serviceable parts inside, refer servicing to qualified service personnel. Français : À prévenir le choc électrique n'enlevez pas les couvercles. Il n'y a pas des parties serviceable à l'intérieur, tous reparations doit etre faire par personnel qualifié seulment. To completely disconnect this equipment from the AC mains, disconnect the power supply cord plug from the AC receptacle. The mains plug of the power supply cord shall remain readily operable. Français : Pour démonter complètement l'équipement de l'alimentation générale, démonter le câble d'alimentation de son réceptacle. La prise d'alimentation restera aisément fonctionnelle. To reduce risk of fire or electric shock, do not expose this apparatus to rain or moisture. Français : Pour réduire les risques d'incendie ou de choc électrique, n'exposez pas l'appareil à la pluie ou à l'humidité. Do not expose this system/apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the apparatus. Français : N'exposez pas ce système/appareil au ruissellement ni aux éclaboussures et assurez-vous qu'aucun objet contenant du liquide tel qu'un vase n'est placé sur l'appareil. This apparatus must be connected to a mains socket outlet with a protective earthing connection. Français : Cet appareil doit être raccordé à une prise secteur avec terre de protection. The mains plug is used as a disconnect device and shall remain readily operable. Français : Lorsque la prise du réseau d'alimentation est utilisés comme dispositif de déconnexion, ce dispositif doit demeuré aisément accessible. IMPORTANT SAFETY INSTRUCTIONS CAUTION! To reduce the risk of fire or electric shock, do not remove screws. No user-serviceable parts inside. Refer servicing to qualified service personnel. Français : Pour réduire le risque d'incendie ou de choc électrique, ne pas retirer les vis. Aucune pièce réparable par l'utilisateur. Confier l'entretien àpersonnel qualifié. 4 d&b 40D Start-up manual 1.8 en Contents 1 Intended use.......................................................................... 6 1.1 About this manual....................................................................... 6 1.2 Loudspeaker types...................................................................... 6 2 Scope of supply.................................................................... 7 3 Technical specifications...................................................... 8 3.1 Current/power draw and thermal dissipation........................ 11 4 Overview.............................................................................. 13 4.1 Connections.............................................................................. 13 4.2 Controls and indicators - User interface.................................. 13 5 Startup................................................................................... 14 5.1 Rack mounting and cooling..................................................... 14 5.2 Connections.............................................................................. 15 5.2.1 Mains connection................................................................. 15 5.2.2 Audio INPUT and LINK/OUT connectors........................... 16 5.2.3 SPEAKER OUTPUTS.............................................................. 17 5.2.4 ETHERNET (Dual Ethernet port)........................................... 18 5.2.5 GPI/GPO (Hardware description)...................................... 19 5.2.6 FAULT..................................................................................... 19 5.3 Controls and indicators............................................................ 20 5.3.1 RESET (System reset)............................................................ 20 5.3.1.1 Network reset option (IP settings).................................... 20 5.3.2 TFT color touchscreen - User interface................................. 21 6 Device configuration........................................................ 22 6.1 Initial device setup.................................................................... 22 7 Service/Maintenance and care................................... 23 7.1 Service...................................................................................... 23 7.2 Maintenance and care............................................................ 23 7.2.1 Touchscreen cleaning........................................................... 23 8 Manufacturer's declarations......................................... 24 8.1 Declaration of Conformity....................................................... 24 8.2 WEEE Declaration (Disposal).................................................. 24 8.3 Licenses and Copyright............................................................ 24 Contents d&b 40D Start-up manual 1.8 en 5 1 Intended use 6 Intended use The d&b 40D amplifier is designed for installation purposes and is intended to be used with applicable d&b loudspeakers. A "LINEAR" setup is available allowing the amplifier to be used as a linear power amplifier. Note: d&b audiotechnik will accept no liability for any damages to third-party loudspeakers when operated with d&b amplifiers in "LINEAR" mode. NOTICE! The device complies with the electromagnetic compatibility requirements of EN 55032:2019 (product family standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use) for the environment Class B (residential). Acoustic interferences and malfunctions may occur if the unit is operated in the immediate vicinity of high-frequency transmitters (e.g. wireless microphones, mobile phones, etc.). Damage to the device is unlikely, but cannot be excluded. 1.1 About this manual With respect to the vast functionality and high complexity of the device, this manual covers the basic safety instructions as well as the vital technical specifications and instructions for startup. A full version of this manual in English language ( Reference manual) with comprehensive information is available for download on the related product page of the d&b website at www.dbaudio.com. 1.2 Loudspeaker types The maximum number of cabinets driven by each channel varies depending on their nominal impedance. It can be found in the respective loudspeaker manual and also in the data section of each loudspeaker product page on the d&b website at www.dbaudio.com. The minimum recommended impedance per channel is 4 ohms. Nom. impedance 4 8 12 16 20 Cabinets per channel 1 2 3 4 5 A list of d&b loudspeakers supported by the amplifier is included in the Release notes of the amplifier firmware. The latest version can be found on the related product page of the d&b website at www.dbaudio.com. d&b 40D Start-up manual 1.8 en 2 Scope of supply Scope of supply Before starting up the device, please verify the shipment for completeness and proper condition of the items. If there is any sign of obvious damage to the unit and/or the power cord, do not operate the unit and contact your local dealer from whom you received it. Pos. Qty. [1] 1 Including: [1.1*] 1 [2] 9 d&b Code Z2830 Z2612.xxx [3] 2 [4] 1 [5] 1 [6] 1 D2036.EN .01 Description d&b 40D Amplifier Power cord (specific to country*) 3-pin Phoenix Euroblock female: Intended for the INPUT/LINK/FAULT connector sockets. Connector type: MSTB 2.5 / 3-STZ - Phoenix order code: 1776168 4-pin Phoenix Euroblock male: Intended for the SPEAKER OUTPUTS connector sockets. Connector type: IPC 5/4-STF-7.62 - Phoenix order code: 1709173 9-pin Phoenix Euroblock female: Intended for the GPI connector socket. Connector type: MSTB 2.59-STZ-5.08 - Phoenix order code: 1764316 5-pin Phoenix Euroblock female: Intended for the GPO connector socket. Connector type: MSTB 2.55-STZ-5.08 - Phoenix order code: 1776142 d&b 40D Start-up manual. Z2612.000 3-pin Schuko CEE 7/7 Z2612.010 3-pin UK BS 1363A Z2612.024* 3-pin U.S. NEMA 5-20P *within delivery Z2612.025* 3-pin U.S. NEMA L6-20P *optional Z2612.040 3-pin South Korea KS C8305 Z2612.050 3-pin Australia AS 3112 Z2612.060 3-pin China GB 2099 Z2612.070 3-pin Switzerland SEV 1011 Z2612.090 3-pin Denmark Afsnit 107-2-D1 Z2612.100 3-pin South Africa SANS 164-1 *Mains plug types and associated standards (Similar illustrations, not in scale) Z2612.110 3-pin Argentina IRAM 2073 Z2612.120 3-pin Brazil NBR 14136 Z2612.130 3-pin India IS 1293 d&b 40D Start-up manual 1.8 en 7 3 Technical specifications Technical specifications Operating conditions Operating temperature (*continuous/**short-term) 10 °C ... +40*/+50** °C (+14 °F ... +104*/+122** °F) Storage temperature 20 °C ... +70 °C (4 °F ... +158 °F) Humidity (rel.), non-condensating < 70 % Power supply Switched mode power supply with automatic mains range selection and active Power Factor Correction (PFC). Mains connector powerCON® TRUE 1 TOP Mains fuse internal Rated mains voltage (High range) 208 - 240 V, 50 - 60 Hz Rated mains current (High range) 13 A Rated mains voltage (Low range) 100 - 127 V, 50 - 60 Hz Rated mains current (Low range) 20 A Protection circuits Mains and power supply: Overvoltage and undervoltage, inrush current limiter, internal fuse. Output: Overcurrent, DC offset, HF voltage limiter, pop-noise suppression. Cooling: Temperature-dependent RPM of fan, self-resetting overtemperature protection. Power consumption (typical values) Standby Idling Peak output 21 W 130 W 2900 W Audio power outputs* SPEAKER OUTPUTS A/B/C/D 2 x 4-pin Phoenix Euroblock female Maximum output voltage/current 180 Vpeak/35 Apeak Output power rating EIA-426B noise CF 12 dB 4 x 2000 W/8 4 x 2400 W/4 Sine wave 1 kHz, long term, +40 °C (+104 °F) 4 x 250 W/4 Frequency response (1 dB, Linear mode) 35 Hz 25 kHz Gain (Linear mode @ 0 dB) 31 dB Output noise/Dynamic range Output noise (BW 20 kHz)/dynamic range (BW 20 kHz, reference 180 Vpk) Analog input 350 µVRMS/111 dB Analog input, A-weighting 250 µVRMS/114 dB Digital/Milan input 200 µVRMS/116 dB Digital/Milan input, A-weighting 150 µVRMS/119 dB THD+N/Crosstalk THD+N (unweighted, 20 20 kHz) 4 x 250 W/8 ohms 4 x 250 W/4 ohms Crosstalk (20 20 kHz) < 86 dB/0.005 % < 83 dB/0.007 % < 70 dBr 4 x 250 W into 8/4 Analog inputs and outputs INPUT A1 - A4 3-pin Phoenix Euroblock male Pin assignment ( ) GND, neg., pos. Input impedance 32 k, electronically balanced CMRR @ 100 Hz/1 kHz / 10 kHz >80/>80/>70 dB Maximum input level (balanced/unbalanced) +25/+18 dBu +27.3 dBu @ 0 dBFS Digital inputs and outputs INPUT - D1/2, D3/4) 3-pin Phoenix Euroblock male, AES3 Pin assignment ( ) GND, AES Signal, AES Signal Input impedance 110 , transformer balanced Sampling frequency 44.1 | 48 | 96 | 192 kHz Word length 16 - 24 bit LINK - D1/2, D3/4 3-pin Phoenix Euroblock male Pin assignment ( ) GND, AES Signal, AES Signal electronically balanced Output modes Mains on: analog signal buffering (refresh) Mains off/power fail: bypass relay MilanTM inputs Device type Input channel streams Redundancy Routable MilanTM inputs Endstation 1 stream with up to 8 channels @ 48/96 kHz Yes (always) M1-8 Digital Signal Processing System start-up time < 45 sec. Time to tone (Standby/ReadyStandby) < 4/< 1 sec. Time to tone (Off/Wake on Audio) < 45 /< 4 sec. Conversion 96 kHz Latency analog/digital (AES) input 0.3/0.3 msec. Latency Milan (AES input DS20 to amplifier loudspeaker output, @96 kHz, 2 ms PTO) 9.7 ms A/D conversion 27 Bit (dual-stacked A/D converters) Internal processing Combination of high-resolution fixed point and floating point processing Equalizer two user definable 16-band equalizers Filter types: PEQ/Notch/HiShlv/LoShlv/Asym Delay 0.3 msec. - 10 sec. Frequency generator Pink noise or Sine wave 10 Hz 20 kHz Network connections Connector type 2 x RJ 45 Switch integrated 2-port, 1 Gbit/100 Mbit IP address/Subnet mask 192.168.1.40/255.255.255.0 ETHERNET 1/PRI MilanTM, Remote control via R1 star topology ETHERNET 2/SEC MilanTM redundancy only, no remote control star topology IP settings (factory default) IP address/Subnet mask 192.168.1.40/255.255.255.0 8 d&b 40D Start-up manual 1.8 en Technical specifications GPI/GPO/FAULT External power supply 24 VDC ±25% (18 30 VDC)/150 W GPI 8 x Opto-coupled (galvanic isolation) High-level 18 ... 30 VDC Low-level 0 ... 9 VDC Serial resistance 5.4 kOhms Forward voltage drop (Uf (max.)) 3.7 V Input current draw per pin @ 9/18/24/30 VDC 1.5/2.6/3.7/4.8 mA Connector type 1 x 9-pin Phoenix Euroblock male Pin assignment ( ) GND, GPIs 1 8 GPO High-state Low-state Max. current draw Connector type Pin assignment 4 x Low-Side-Switch-Relay Closed (connected to common GPO GND) Open (high resistive) 1 A/Total: 4 A 1 x 5-pin Phoenix Euroblock male ( ) GND, GPOs 1 4 FAULT NO - Normally Open | NC - Normally Closed 1 x 3-pin Phoenix Euroblock male Controls and indicators RESET TFT color touchscreen Recessed push-button (rear panel) 4.3"/480 x 272 pixels Fan noise emission Rack mounted, measured on axis, 1 m (3.3 ft) to front panel, A-weighting. Min./Max. RPM 30/50 dB(A) Ambient temperature 23 °C/73.4 °F Dimensions and weight Height x width x depth Weight 2 RU x 19" x 465 mm (18.3") 13.3 kg/29.3 lb 40D enclosure dimensions in mm [inch] d&b 40D Start-up manual 1.8 en 9 Technical specifications *Audio power output Measurement references: All data is valid for 23 °C (73.4 °F) ambient temperature and 230 VAC/50 Hz mains supply. The power rating of noise signals is defined as the maximum of the instantaneous output power divided by a factor of two. The power of burst signals refers to the power during the "on" period. The duration of the peak output of a sine wave signal is defined at a drop of 0.5 dB/10% relative to the maximum output power. EIA-426B noise Crest factor 12 dB 9 dB 6 dB 1 kHz burst On/off time 20 ms/0 dB 480 ms/20 dB 200 ms/0 dB 600 ms/20 dB 1 kHz sine wave Channels used 1 4 Load [ohms] 8 4 8 4 8 4 Load [ohms] 8 4 8 4 Load [ohms] 8 4 8 4 Power rating [W] 4 x 2000 4 x 2400 4 x 2000 4 x 1300 4 x 1150 4 x 700 Power average [W] 4 x 250 4 x 300 4 x 500 4 x 325 4 x 575 4 x 375 Power [W] 4 x 1150 4 x 1200 4 x 750 4 x 700 Max. output power [W] 1 x 2000 1 x 2400 4 x 2000 4 x 2400 Duration of max. output 2000 ms 110 ms 4 ms 5 ms 10 d&b 40D Start-up manual 1.8 en Technical specifications Measurement references For all noise signals, the values are measured at the maximum level just before any amplifier limiter activity (no Gain Reduction). Noise CF 12 dB: Noise signal according to EIA-426-B with a crest factor of 12 dB. This represents the use case of live music or less compressed recorded music. Noise CF 9 dB: Noise signal according to EIA-426-B with a crest factor of 9 dB. This represents the use case of music with medium compression. 3.1 Current/power draw and thermal dissipation Noise CF 6 dB: Noise signal according to EIA-426-B with a crest factor of 6 dB. This represents the use case of heavily compressed music. Sine wave (100 ms): 1 kHz sine wave signal, 0 dBFS input level and a duration of 1 s. The RMS current value is calculated over a 100 ms time window. This window is stepped in increments of 10 ms over the recording. The resulting value is the highest current within a window of 100 ms. 230 VAC / 50 Hz / 0.5 Source impedance - all channels driven State Load Mains [ohms] current [A RMS] Power factor Input power [W] Standby - 0.29 0.31 20.8 ReadyStandby - 0.43 0.54 52.6 Eco - 0.83 0.54 103 Idling - 0.75 0.74 127 Noise CF 12 dB 8 6.1 4 7.8 0.95 1300 0.96 1700 Noise CF 9 dB 8 11.6 0.98 2550 4 8.2 0.97 1800 Noise CF 6 dB 8 13 4 8.8 0.99 2900 0.98 1950 Sine wave max. 1 s 8 16.6 - - 4 16.5 - - Output power [W] - - - - 1000 1200 2000 1300 2300 1400 - Power loss [W] 20.8 52.6 103 127 300 500 550 500 600 550 - BTU/hr 71 179 351 433 1024 1706 1876 1706 2047 1876 - kCal/hr 18 45 89 109 258 430 473 430 516 473 - 208 VAC / 60 Hz / 0.5 Source impedance - all channels driven State Load Mains [ohms] current [A RMS] Power factor Input power [W] Standby - 0.32 0.32 20.8 ReadyStandby - 0.46 0.53 50.2 Eco - 0.86 0.54 97 Idling - 0.82 0.74 126 Noise CF 12 dB 8 6.8 4 8.8 0.96 1350 0.96 1750 Noise CF 9 dB 8 13.1 0.98 2600 4 9.2 0.98 1850 Noise CF 6 dB 8 13.7 0.99 2750 4 9.9 0.98 2000 Sine wave max. 1 s 8 18.4 - - 4 18.4 - - Output power [W] - - - - 1000 1200 2000 1300 2100 1400 - Power loss [W] 20.8 50.2 97 126 350 550 600 550 650 600 - BTU/hr 71 171 331 430 1194 1876 2047 1876 2218 2047 - kCal/hr 18 43 83 108 301 473 516 473 559 516 - d&b 40D Start-up manual 1.8 en 11 Technical specifications 120 VAC / 60 Hz / 0.2 Source impedance - all channels driven State Load Mains [ohms] current [A RMS] Power factor Input power [W] Standby - 0.32 0.50 18.8 ReadyStandby - 0.60 0.72 52.0 Eco - 1.44 0.60 104 Idling - 1.26 0.86 130 Noise CF 12 dB 8 12.1 0.96 1350 4 15.9 0.96 1800 Noise CF 9 dB 8 18.8 0.98 2100 4 16.6 0.98 1900 Noise CF 6 dB 8 19.7 0.99 2250 4 17.7 0.98 2000 Sine wave max. 1 s 8 25.2 - - 4 27.7 - - Output power [W] - - - - 1000 1200 1600 1300 1650 1400 - Power loss [W] 18.8 52.0 104 130 350 600 500 600 600 600 - BTU/hr kCal/hr 64 16 177 45 355 89 444 112 1194 301 2047 516 1706 430 2047 516 2047 516 2047 516 - - - - 100 VAC / 60 Hz / 0.2 Source impedance - all channels driven State Load Mains [ohms] current [A RMS] Power factor Input power [W] Standby - 0.34 0.55 18.7 ReadyStandby - 0.65 0.75 48.2 Eco - 1.54 0.61 94.8 Idling - 1.45 0.88 128 Noise CF 12 dB 8 14.9 0.97 1400 4 19.9 0.96 1850 Noise CF 9 dB 8 21.2 0.98 2000 4 20.8 0.98 1950 Noise CF 6 dB 8 21.0 0.99 2000 4 21.1 0.99 2000 Sine wave max. 1 s 8 30.3 - - 4 32.7 - - Output power [W] - - - - 1000 1200 1450 1300 1450 1350 - Power loss [W] 18.7 48.2 94.8 128 400 650 550 650 550 650 - BTU/hr kCal/hr 64 16 164 41 323 82 437 110 1365 344 2218 559 1876 473 2218 559 1876 473 2218 559 - - - - 12 d&b 40D Start-up manual 1.8 en 4 Overview 4.1 Connections Overview [1] Mains connector socket. Refer to Chapter 5.2.1 "Mains connection" on page 15. [3] Output connectors. [2] Audio INPUT (analog/digital) and Refer to Chapter 5.2.3 "SPEAKER LINK connectors. OUTPUTS" on page 17. Refer to Chapter 5.2.2 "Audio INPUT and LINK/OUT connectors" on page 16. [4] ETHERNET. Refer to Chapter 5.2.4 "ETHERNET (Dual Ethernet port)" on page 18. [5] GPI /GPO connector. [6] Refer to Chapter 5.2.5 "GPI/GPO (Hardware description)" on page 19. [7] FAULT connector. Refer to Chapter 5.2.6 "FAULT" on page 19. 4.2 Controls and indicators - User interface [9] User interface / Status indicators Refer to [8] RESET Refer to Chapter 5.3.1 "RESET (System reset)" on page 20 d&b 40D Start-up manual 1.8 en 13 5 Startup Startup 5.1 Rack mounting and cooling Rack mounting The enclosure is designed to fit standard 19" equipment racks or cabinets. NOTICE! When mounting the device into 19" equipment racks or cabinets, it is strongly recommended that you: Always fix the device at its front AND rear rack ears using appropriate rack mounting screws and U-washers, as shown in the graphic opposite. Alternatively use shelves fixed to the inner sides of the equipment rack or cabinet. Cooling Thermal conditions are a vital factor to ensure operational safety of the power amplifiers. The amplifiers are equipped with two internal fans that draw cool air from the front into the housing and channel the warm air towards the back of the device. Please ensure that adequate cool airflow is provided. Do not block or cover the front panel air intake or the vents on the rear panel. If the amplifiers are installed in sealed cabinets (e.g. in fixed installations), use additional fan modules with filters that can be easily replaced without opening the sealed cabinets. Do not combine the amplifiers with D6 or D12 amplifiers in one rack. Do not rack up the amplifiers together with other devices producing additional heat with opposing airflow. 14 d&b 40D Start-up manual 1.8 en d&b 40D Start-up manual 1.8 en 5.2 Connections Startup 5.2.1 Mains connection WARNING! Potential risk of electric shock or fire. The device is a protective class 1 unit. A missing earth (ground) contact may cause dangerous voltages in the housing and controls and may lead to electric shock. Connect the device to mains power supplies with protective earth only. If there is any sign of obvious damage to the power cord and/or mains plug, do not use the power cord and replace it before further use. Please ensure the mains connector is accessible at any time to disconnect the device in case of malfunction or danger. If the mains plug is not readily accessible due to mounting in a 19" rack or equipment cabinet, then the mains plug for the entire rack or cabinet must be readily accessible. Do not connect or disconnect the mains plug under load. Before connecting the device to mains voltage, check that the mains voltage and frequency correspond to the specifications on the rating label next to the mains connector socket on the rear panel of the unit. Mains voltage range 100 to 240 VAC, 50/60 Hz, 1800 W. A powerCON® TRUE 1 TOP mains connector socket [1] is fitted on the rear panel and an appropriate power cord [1.1] is supplied. Required mains configuration An appropriate circuit breaker from the on-site power distribution system is required: 100 - 127 VAC 50/60 Hz - 20 Amax. B- or C-frame type. 208 - 240 VAC 50/60 Hz - 16 Amax. B- or C-frame type. 15 Startup 5.2.2 Audio INPUT and LINK/OUT connectors The rear panel features eight installation specific Phoenix Euroblock connectors with the following assignments: Four analog inputs (A1 - A4) with corresponding link outputs. Two digital AES3 inputs (D1/2 and D3/4 - four channels) with corresponding outputs. The digital inputs are fitted with permanent, high-speed, highquality SRCs, thus AES3 signals from different sources and with differing sample rates can be processed without requiring any further user configuration. Each input channel can be routed to any of the output channels A to D. Analog INPUT (A1 - A4) A 3-pin Phoenix Euroblock connector (male) is provided for each analog input to accept the supplied 3-pin Phoenix Euroblock connector (female). To feed (link) the input signal on to the next device in the signal chain, the connector can also be used as a cable tap. Specifications Pin assignment ( ) GND, neg., pos. Input impedance 32 kOhms, electronically balanced CMRR @ 100 Hz/1 kHz/10 kHz >80/>80/>70 dB Maximum input level (balanced/unbalanced) +25/+18 dBu +27.3 dBu @ 0 dBFS Digital INPUT and LINK (D1/2 - D3/4) A 3-pin Phoenix Euroblock connector (male) is provided for each pair of digital inputs to accept the supplied 3-pin Phoenix Euroblock connector (female). The corresponding digital LINK output (1/2, 3/4) can be used to feed a refreshed input signal to the next device in the signal chain. The signal shape (the rising and falling edges of the signal) and level are refreshed with an analog buffer amplifier. A power fail relay is incorporated to prevent interruption of the signal chain should there be a power failure. In this situation, the digital input signal bypasses the analog buffer amplifier and is routed directly to the LINK output. Specifications Pin assignment ( ) GND, AES Signal, AES Signal Input impedance 110 ohms, transformer balanced Sampling frequency 44.1 | 48 | 96 | 192 kHz Word length 16 - 24 bit Digital LINK (D1/2, D3/4) 3-pin Phoenix Euroblock male electronically balanced analog signal buffering (refresh), power fail relay (Bypass) 16 d&b 40D Start-up manual 1.8 en Startup 5.2.3 SPEAKER OUTPUTS WARNING! Potential risk of electric shock or fire. Risk of electric shock The amplifier output pins can carry dangerous voltages. Only use isolated loudspeaker cables with correctly fitted connectors. Never connect an amplifier output pin to any other input or output connector pin or protective earth (ground). Bridge mode is not applicable. Risk of fire To avoid any heating of the output connector terminal (glowing contact), the wires need to be properly fitted to the output connector terminal. Only use the enclosed Euroblock connector terminals. Observe the maximum cross-section of 6 mm2 (AWG 10). Ensure all contact screws are properly tightened. Ensure the fixing screws of the connector terminal are properly fitted to the output connector socket of the device. The amplifier is equipped with two Phoenix Euroblock connector sockets (female), one for each pair of amplifier output channels (A/B, C/D). All pins of both output connectors are hardwired and permanently driven using the following pin assignment. SPEAKER OUTPUTS A (B, C, D) + = Amp A (B, C, D) pos. -- = Amp A (B, C, D) neg. Note: For further information regarding the applicable output modes for each loudspeaker system, please refer to the relevant loudspeaker manual. d&b 40D Start-up manual 1.8 en 17 Startup 5.2.4 ETHERNET (Dual Ethernet port) NOTICE! Only shielded network cables (STP) must be used! The device allows remote control as well as redundant digital audio networking (MilanTM) via Ethernet. For this purpose, a Dual Ethernet port (1 Gbit/s/100 Mbit/s peer-to-peer) is provided requiring star topology network wiring. Daisy-chaining is not supported. For standard remote control via the d&b Remote network using the d&b R1 Remote control software or the integrated Web remote interface, the upper RJ45 (ETHERNET 1/PRI) connector socket is used. This connector socket is also used for the primary (PRI) MilanTM signal while the bottom RJ45 connector socket (ETHERNET 2/ SEC) is used for the redundant MilanTM signal only. LED indicators The two LED indicators above the respective connector in use indicate the following states: Green Yellow Illuminates permanently when the device is connected to an active network and flashes as long as a data stream is transmitted. Is off when the speed is 100 Mbit/s. Illuminates permanently when the speed is 1 Gbit/s. 18 d&b 40D Start-up manual 1.8 en GPI | GPO Schematic circuit diagrams and logic level chart (GPI) FAULT Schematic circuit diagram and switching status: a) Device is On and operating b) Device is Off or general device error d&b 40D Start-up manual 1.8 en Startup 5.2.5 GPI/GPO (Hardware description) Up to eight opto-coupled GPI pins [5] (General Purpose Input) and up to four GPO pins [6] (General Purpose Output) are available as additional digital control lines. This enables external control and detection functions. Note: A detailed description of how to configure the GPIOs and assign the available software objects (functions) correspondingly is given in the 40D Reference manual, which can be downloaded from the related product page at www.dbaudio.com. Each GPI provides either level (Hi/Lo active - non-latching) or edge (rising/falling - latching) triggering. Note: When using a GPI or GPO contact, observe the following: An external DC power supply is required. GPI: The corresponding pin is connected via an opto- coupler with a serial resistance of 5.4 k. GPO: The corresponding pin is connected to ground (GND/ ) via a relay (Low-Side-Switch). Make sure the current per GPO pin does not exceed 1 A. Technical specifications External power supply 24 VDC ±25% (18 30 VDC)/150 W GPI 8 x Opto-coupled (galvanic isolation) High-level 18 ... 30 VDC Low-level 0 ... 9 VDC Serial resistance 5.4 kOhms Forward voltage drop (Uf (max.)) 3.7 V Input current draw per pin @ 9/18/24/30 VDC 1.5/2.6/3.7/4.8 mA Connector type 1 x 9-pin Phoenix Euroblock male Pin assignment ( ) GND, GPIs 1 8 GPO High-state Low-state Max. current draw Connector type Pin assignment 4 x Low-Side-Switch-Relay Closed (connected to common GPO GND) Open (high resistive) 1 A/Total: 4 A 1 x 5-pin Phoenix Euroblock male ( ) GND, GPOs 1 4 5.2.6 FAULT An additional 3-pin Phoenix Euroblock fault contact [7] is provided allowing a general device error to be remotely indicated. Note: The assignment of the corresponding software object is fixed and cannot be changed by the user. During a firmware update, the fault contact switches to status b), as shown in the graphic opposite. NO Normally Open C Common NC Normally Closed 19 5.3 Controls and indicators Startup 5.3.1 RESET (System reset) A reset button (RESET [8]) is located on the rear panel next to the digital LINK D3/D4 connector terminal. To prevent accidental system reset, the button is slightly recessed. To perform a system reset, proceed as follows: Note: All device preferences will be set to factory defaults except for the network and fixed device settings. 1. Isolate the device from mains power by releasing the powerCON connector and turn it counterclockwise. 2. Press and hold the «RESET» button using an appropriate pen. 3. While holding the «RESET» button pressed, repower the device by turning the powerCON connector clockwise. Long confirmation beep. 4. Release the «RESET» button and briefly press the button again within 2 sec. Short confirmation beep the device will reboot. 5.3.1.1 Network reset option (IP settings) Executing the following reset procedure allows you to locally change/edit the network (IP) settings, if required. Once the settings have been changed and the device has been shut down, the access to the network settings will be disabled again after repowering the device. 1. During normal operation, press and hold the «RESET» button for 5 sec. Long confirmation beep. 2. Release the «RESET» button and briefly press the button again within 2 sec. Short confirmation beep. The network settings will become accessible for editing by tapping the «Network» navigation button as shown in the graphic opposite. 20 d&b 40D Start-up manual 1.8 en Screen access and structure chart Startup 5.3.2 TFT color touchscreen - User interface NOTICE! The touch panel utilizes a thin flexible sheet that may be damaged by sharp objects or heavy treatment. The user interface consists of a 4.3" TFT color touchscreen [9] with a resolution of 480 x 272 pixels. The resistive touchscreen responds to pressure and therefore can be operated by a fingertip, even when wearing gloves or by an appropriate stylus tip (pen). Screen contents The display provides comprehensive information regarding the channel settings/statuses as well as the device settings/statuses. The structure of the screen content(s) is divided into two main axes, the «Home» view, including the «Channel» settings/statuses, and the «Device» settings/statuses views. Note: A detailed description on the screen contents is given in the 40D Reference manual which can be downloaded from the related product page at www.dbaudio.com. Accessing the screen contents To access a particular subscreen, simply tap ( ) the corresponding screen item, shown as an example in the graphic below. d&b 40D Start-up manual 1.8 en 21 6 Device configuration Device configuration 6.1 Initial device setup The device is mainly intended to be set up and operated via the d&b Remote network using the d&b R1 Remote control software. Provided R1 is already installed and the device has been connected either directly or through the network, proceed as follows: From the startup menu, choose the «R1 V3 Initial device setup» entry. R1 is launched and automatically switches to «Online» mode and the «Service» view is displayed. In the left pane of the view, the connected device is listed. In the right pane, the corresponding «Filter» «Initial device setup» is set by default and provides you with basic parameters (in alphabetical order) to set up the device. 22 d&b 40D Start-up manual 1.8 en 7 Service/Maintenance and care Service/Maintenance and care 7.1 Service CAUTION! Potential risk of explosion. The device incorporates a lithium battery which may cause danger of explosion if not replaced correctly. Refer replacement only to qualified service personnel authorized by d&b audiotechnik. Do not open the device. No user serviceable parts inside. In case of any damage do not operate the device under any circumstances. Refer servicing only to qualified service personnel authorized by d&b audiotechnik. In particular if: objects or liquids have entered the device. the device does not operate normally. the device was dropped or the housing is damaged. 7.2 Maintenance and care During normal operation, the amplifier provides maintenance-free service. Due to the cooling concept, no dust filters are required. As a result, filter exchange or cleaning the filters is not necessary. However, the air-intake is covered by a grill which should be regularly cleaned (vacuumed) using an appropriate vacuum cleaner. 7.2.1 Touchscreen cleaning After a certain period of time, the touchscreen may require cleaning. For this purpose, proceed as follows: Use a soft cloth only. Do not use any solvent cleaners. To remove very heavy dirt from the panel, it may be helpful to use a special cleaning spray for TFT screens. In this case, proceed as follows: 1. Spray on the soft cloth before wiping the screen. Never apply/spray directly on the screen as the liquid could penetrate the device. 2. Wipe the screen with moderate pressure. d&b 40D Start-up manual 1.8 en 23 8 Manufacturer's declarations Manufacturer's declarations 8.1 Declaration of Conformity This declaration applies to: d&b Z2830 40D Amplifier by d&b audiotechnik GmbH & Co. KG. All product variants are included, provided they correspond to the original technical version and have not been subject to any later design or electromechanical modifications. We herewith declare that said products are in conformity with the provisions of the respective directives including all applicable amendments. Detailed and applicable declarations are available on request and can be ordered from d&b or downloaded from the d&b website at www.dbaudio.com. 8.2 WEEE Declaration (Disposal) Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime. Please dispose of this product according to the respective national regulations or contractual agreements. If there are any further questions concerning the disposal of this product, please contact d&b audiotechnik. WEEE-Reg.-Nr. DE: 13421928 8.3 Licenses and Copyright A list of the components and a full-text version of all licenses and copyrights can be accessed using the amplifier's Web Remote interface. Selecting the d&b logo at the top left of the «Web Remote» interface page allows access to the «Licenses and Copyright» information page. This page provides an overview of the open source software used in this product. As required by the GPL and LGPL licenses, we will send you a copy of the used source code on request. If you would like to obtain a copy, please contact us by mail to: software.support@dbaudio.com 24 d&b 40D Start-up manual 1.8 en www.dbaudio.com D2036.EN .01, 05/2025 © d&b audiotechnik GmbH & Co. KG