PRODUCT CONTENTS

This package contains:

  • 1 pureAir 3000 Whole Home Air Purifier
  • 1 Quick Start Card
  • 1 DC POWER ADAPTER
  • 1 POWER CORD
  • 1 Owner's Manual
  • 1 REMOTE with Batteries

RECORDS

Please record the name and phone number of your Dealer.

Name: ________________________________________________________________________

Phone #: ______________________________________________________________________

Please record the serial number of your pureAir 3000.

Serial #: _______________________________________________________________________

ABOUT

pureAir active air purifiers provide a cleaner indoor environment, improving indoor air quality.

pureAir 3000 has a broad range of air purification technologies:

  • Ionization to go out and charge harmful particulates, causing them to clump together and drop out of your breathing space.
  • Activated oxygen (Ozone) attaches itself to contaminants at the molecular level, destroying them. This process eliminates the contaminant while reverting the activated oxygen back to oxygen.
  • Active Radiant Catalysis, or ARC®, a proprietary form of photocatalytic oxidation (PCO) that uses ultraviolet energy to activate a catalyst that converts water vapor into advanced oxidation products (AOPs) to continuously clean your space.

The result of these technologies is a reduction of odors, allergens, and other volatile organic compounds.

Regular cleanings and only once-per-year part replacement makes it simple and affordable to keep your home clean.

GreenTech Environmental wants you to have the best experience with our product. Contact us anytime by visiting www.GreenTechEnv.com/Support.

Don't forget to register your warranty, while you're thinking about it, at www.GreenTechEnv.com/Warranty. We're here for you.

SPECIFICATIONS

Model NumberPUREAIR3000-BK-US
Power Input100-240 VAC 50/60Hz 2.5A
Power Usage22 Watts (Normal) 38 Watts (High)
Product Dimensions12.25" H x 8.88"W x 10.75" D (31.12 cm H x 22.55 cm W x 27.31 cm D)
Product Weight11 lb (5 kg)
WarrantyOne Year Manufacturer's Warranty

IMPORTANT SAFETY INSTRUCTIONS

WARNINGS

  • When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons.
  • NEVER operate the unit near a heat source, open flame, flammable/combustible fluids, or sources of liquids.
  • DO NOT operate the unit unless all parts (including ARC CELL, OZONE PLATE, FILTER ASSEMBLY, and REAR COVER) are properly installed.
  • The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.
  • The unit is not intended for outdoor use.
  • DO NOT use any product with a damaged cord or plug, or if the product malfunctions, is dropped, or is at all damaged. Keep cord away from heated surfaces.
  • DO NOT run power cords under carpets or rugs. Arrange the power cord to avoid being tripped over.

CAUTIONS

  • DO NOT view the ultraviolet light directly when the unit is powered and in operation as it may result in severe eye injury. The lamp is not directly visible when mounted in assembled unit.
  • DO NOT USE AWAY MODE in spaces occupied by human beings or pets. Allow for 2 hours following treatment in AWAY MODE prior to returning. Temporary adverse reactions such as throat irritation, coughing, chest pain, or shortness of breath may be caused by excessive levels of ozone. Check that the unit is turned off and further ventilate space prior to returning. If adverse reactions persist, seek medical attention and discontinue use of device.
  • ARC Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. DO NOT handle if broken or hot.
  • DO NOT use device in HIGH MODE during planned activity of heavy exertion such as exercising.
  • DO NOT adjust the square footage setting to exceed the square footage of the space being treated.
  • DO NOT block the ventilation or filters.
  • DO NOT place unit directly facing sitting or sleeping areas.

DIAGRAMS - UNIT EXTERIOR

Front of Unit

  • 1. IONIZATION NEEDLE
  • 2. FRONT GRILLE SCREWS
  • 3. FRONT GRILLE
  • 4. CONTROL PANEL

Side of Unit

  • 5. REAR COVER
  • 6. UNIT REAR
  • 7. UNIT FRONT

Rear of Unit

  • 8. REAR COVER SCREW
  • 9. DC POWER ADAPTER INLET

DIAGRAMS - UNIT INTERIOR/POWER ADAPTER

Rear with REAR COVER Removed

  • 1. BRASS THUMBSCREWS
  • 2. FILTER ASSEMBLY
  • 3. FILTER ASSEMBLY TABS

Rear with FILTER ASSEMBLY Removed

  • 4. ARC CELL
  • 5. ARC CELL RETAINING NUTS
  • 6. ARC CELL CONNECTOR
  • 7. PURIFICATION PLATE

DC POWER ADAPTER & POWER CORD

  • 8. POWER CORD
  • 9. POWER CORD PLUG
  • 10. DC POWER ADAPTER
  • 11. DC POWER ADAPTER PLUG

DIAGRAMS - CONTROLS

CONTROL PANEL & REMOTE

  • 1. POWER BUTTON
  • 2. SLEEP MODE CONTROL
  • 3. FAN SPEED CONTROL
  • 4. REMINDER RESET BUTTON
  • 5. INFRARED RECEIVER
  • 6. PURIFIER LEVEL CONTROL
  • 7. AWAY MODE TOGGLE
  • 8. NORMAL/HIGH MODE TOGGLE

DIAGRAMS - DISPLAY

DISPLAY

  • 1. FAN SPEED INDICATOR
  • 2. MODE SPECIFIC DISPLAY
  • 3. MODE INDICATOR
  • 4. PURIFICATION LEVEL WARNING
  • 5. MAINTENANCE REMINDERS
  • 6. AWAY MODE WARNING

Here's how the DISPLAY appears when in each of the modes:

ARC (Normal)

FAN ARC

High Mode

FAN 3000 FT² PURIFIER SETTING MUST NOT EXCEED SIZE OF AREA

Away Mode

FAN 2:00 HRS AWAY MODE ENSURE AREA IS UNOCCUPIED WHILE AWAY MODE IS ACTIVE

SETTING UP

This is going to be easy.

  1. Unpack your pureAir 3000 Remove everything from the box. Check and make sure you have everything listed in “PRODUCT CONTENTS” on page 2. Keep your packaging in case you need to return or exchange your unit. When you are satisfied with your unit, please recycle the box and properly dispose of all other packaging materials.
  2. Select a location for your pureAir 3000 There are several things to consider when selecting a location. First, find a common room that contains an HVAC return or adjoining a hallway that has an HVAC return. Ideally, locate the unit within twelve to twenty four inches (12"-24") of the ceiling, on a bookcase, shelf, or mounting bracket. Make sure that there is nothing within three inches (3") of the rear of the unit for proper air flow. Point the unit towards the center of the room. Never place an operating unit on the floor.
  3. Place your pureAir 3000 and plug it in Check to make sure your unit is secure. Falling units can cause serious headaches! Unravel the cord attached to your DC POWER ADAPTER and your POWER CORD. Plug the DC POWER ADAPTER PLUG into the rear of the unit, then plug the POWER CORD into the wall. Make sure the POWER CORD is securely seated in the DC POWER ADAPTER and that the green indicator light on the DC POWER ADAPTER is lit, showing that it properly connected.

MAINTENANCE REMINDERS

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

ARC Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. DO NOT handle if broken or hot.

"REPLACE CELL"

When “REPLACE CELL” appears, the ARC CELL has stopped functioning and must be replaced. Contact your dealer or www.GreenTechEnv.com/Support to order a replacement. Once a replacement has been obtained, follow the instructions in “DISASSEMBLY” and “ASSEMBLY” (pages 12-15) to replace your old ARC CELL.

Note that the ARC CELL relies upon ultraviolet (UV) energy to power the catalytic reaction. Over time, the UV energy output degrades. For this reason, the ARC CELL should be replaced after one (1) year of continuous operation (9000 hours) regardless of the presence of the “REPLACE CELL” maintenance reminder.

"PERFORM CLEANING"

“PERFORM CLEANING” will display once the unit has been run for 30 days total running time and the unit requires a complete cleaning. Follow the instructions in “CLEANING" on page 16.

INITIAL SETTINGS

Before using your pureAir 3000 you will need to find the area (or square footage) of the environment. To do this accurately, take into account all connected rooms with open doorways (the cleaning does not flow through closed doors). The pureAir 3000 can clean up to 3,000 square feet* of space.

*Based on average ceiling height of 8.5' and open floor plan and/or adjoining rooms for single level dwelling.

Once you have determined an ideal location for your unit and calculated the area of the environment:

  1. Connect the POWER CORD to the DC POWER ADAPTER and the DC POWER ADAPTER PLUG into the unit. (Check to be sure your power supply is properly assembled. The POWER CORD should be inserted far enough into the DC POWER ADAPTER so that a space of only about 1/8 in. is left between the widest part of the POWER CORD and the edge of the DC POWER ADAPTER.)
  2. Insert the Power Plug into the wall outlet.
  3. Turn the unit on and set it to NORMAL MODE (ARC) (see CONTROLS).
  4. Leave the unit on NORMAL MODE (ARC) for at least 24 hours to begin with.
  5. After 24 hours, set the unit to HIGH MODE and set the square footage to 250 square feet.
  6. Gradually increase the square footage setting every 12 - 24 hours until you reach the accurate square footage of your area which you calculated in the beginning steps. Note: Using the unit at a setting less than the square footage of the area being treated is acceptable and may be desirable in an environment relatively free of pollutants.
  7. If you reach your recommended square footage and still notice an unpleasant odor from your space, consider using AWAY MODE for an extra cleaning boost. (See page 11 for AWAY MODE instructions.)

CONTROLS

Turning the unit ON/OFF

Press the POWER BUTTON on the CONTROL PANEL or REMOTE to turn the unit on. The unit will initially be set to NORMAL MODE (ARC). Press the POWER BUTTON once more to turn the power off.

Using NORMAL MODE (ARC)

  • Press NORMAL/HIGH MODE TOGGLE until “ARC” is shown in the MODE SPECIFIC DISPLAY.
  • Square footage not available in “NORMAL MODE (ARC)”.
  • To control the fan speed: Use FAN SPEED CONTROL.

Using HIGH MODE

  • Press the NORMAL/HIGH MODE TOGGLE and verify that “HIGH MODE” is shown in the MODE INDICATOR.
  • To set the square footage on the DISPLAY: Use PURIFIER LEVEL CONTROL (See “INITIAL SETTINGS” page 10).
  • To control the fan speed: Use FAN SPEED CONTROL.

Never adjust setting to exceed square footage of ventilated space being treated.

Using AWAY MODE

DO NOT use AWAY MODE in spaces occupied by human beings or pets. Allow for 2 hours following treatment in AWAY MODE prior to re-entering. Temporary adverse reactions such as throat irritation, coughing, chest pain, or shortness of breath may be caused by excessive levels of ozone. If irritation occurs, check that unit is turned off and further ventilate space prior to returning. If adverse reaction persists, seek medical attention and discontinue use of device.

  • Press the AWAY MODE TOGGLE and verify that “AWAY MODE” is shown in the MODE INDICATOR.
  • To set the AWAY MODE TIMER: press the AWAY MODE TOGGLE. Each press of the AWAY MODE TOGGLE adds two hours to the AWAY MODE TIMER.
  • Select 2:00, 4:00, 6:00, or 8:00 hours.
  • Pressing AWAY MODE once when the AWAY MODE TIMER shows 8:00 will revert the unit back to the mode it was in before you pressed the AWAY MODE TOGGLE.
  • Please allow for 2 hours following AWAY MODE treatment ending prior to entering.

Using SLEEP MODE

If the light produced by the DISPLAY and CONTROL PANEL causes a distraction, such as when sleeping or viewing your television, simply press the SLEEP MODE CONTROL on the REMOTE and the lighting will cycle through: low brightness, off, high brightness.

DISASSEMBLY

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

[Notice] Refer to the Diagram Section (Pg. 5-6) for further illustrations of part names and locations.

Tools Required

You will need a #2 Phillips screwdriver.

Workspace Recommendations

A counter top or flat surface is ideal for disassembling/assembling your unit. You will need 2ft x 3ft of clean, accessible workspace. It is recommended to use a small bowl or cup to hold any screws so they are not lost during the process.

Disassembly Instructions

  1. Turn the unit off.
  2. Remove the POWER CORD PLUG from the wall and the DC POWER ADAPTER PLUG from the rear of the unit.
  3. Clean exterior of unit if necessary (see “CLEANING" page 16).

Removing the REAR COVER:

  1. Using your screw driver, remove the REAR COVER SCREW from the REAR COVER (above the DC POWER ADAPTER INLET). Place the REAR COVER SCREW where you will find it easily during reassembly.
  2. Squeeze the sides of the REAR COVER until they release and tilt the REAR COVER slightly upwards and pull directly away from the unit. Clean with compressed air or a damp cloth. Set the REAR COVER aside.

Removing the FILTER ASSEMBLY:

  1. Remove BRASS THUMBSCREWS from the top corners of the FILTER ASSEMBLY.
  2. Place BRASS THUMBSCREWS where you will find them easily during reassembly.
  3. Grasp the top of the FILTER ASSEMBLY and tilt away from the unit. Clean if necessary (see “CLEANING" page 16) and set the FILTER ASSEMBLY aside. Lift FILTER ASSEMBLY TABS on either side of FILTER ASSEMBLY to remove the rim and access the separate honeycomb, foam, and mesh layers.

DISASSEMBLY (Continued)

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

[Notice] Refer to the Diagram Section (Pg. 5-6) for further illustrations of part names and locations.

Removing the PURIFICATION PLATE:

Grasp the PURIFICATION PLATE on the ceramic portion and gently pull it out of the grooves on the sides. Clean (see “CLEANING" page 16) and set the PURIFICATION PLATE aside.

Removing the ARC CELL:

ARC Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. DO NOT handle if broken or hot.

  1. Locate the ARC CELL CONNECTOR on the right of the rear of the unit almost halfway up the unit (beside the PURIFICATION PLATE slot). Squeeze the tabs on the top and bottom of the ARC CELL CONNECTOR and pull gently until free from the ARC CELL CONNECTOR outlet.
  2. Remove the ARC CELL RETAINING NUTS from the Screw Posts on the right and left below the ARC CELL. Place the ARC CELL RETAINING NUTS where you will find them easily during reassembly.
  3. Gently slide the ARC CELL out of the unit. Clean (see “CLEANING" page 16) and set the ARC CELL aside.

Clean the interior of the unit (see “CLEANING” page 16).

Removing the FRONT GRILLE:

  1. Locate the four FRONT GRILLE SCREWS in the two upper corners of the FRONT GRILLE. Using your screw driver, carefully remove the two FRONT GRILLE SCREWS. Place the FRONT GRILLE SCREWS where you will find them easily during reassembly.
  2. Remove the FRONT GRILLE by tilting the top away from the unit until the FRONT GRILLE can be lifted free. Ensure that the IONIZATION NEEDLE (in the top center of the front of the unit) is not damaged. Clean the FRONT GRILLE if necessary (using compressed air, vacuum cleaner, damp cloth or warm soapy water) and set the FRONT GRILLE aside.
  3. Clean the IONIZATION NEEDLE if necessary (see “CLEANING" page 16).

ASSEMBLY

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

[Notice] Refer to the Diagram Section (Pg. 5-6) for further illustrations of part names and locations.

Refer to "TOOLS & WORKSPACE" from “DISASSEMBLY” on Page 12

Installing the FRONT GRILLE:

  1. Gently set the bottom of the FRONT GRILLE in place on the lower front of the unit and swing the top of the FRONT GRILLE into place, being careful not to damage the IONIZATION NEEDLE at the top center of the front of the unit.
  2. Insert the two FRONT GRILLE SCREWS one at a time until they are in place, but not tight. After both FRONT GRILLE SCREWS are in place, tighten them carefully.

Installing the ARC CELL:

ARC Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. DO NOT handle if broken or hot.

  1. Position the ARC CELL inside the unit so that the two tabs are on the bottom of the ARC CELL. Ensure the holes in the two tabs fit over the two screw posts. Screw the ARC CELL RETAINING NUTS onto the screw posts until they are snug.
  2. Align the ARC CELL CONNECTOR to the ARC CELL CONNECTOR outlet and insert gently until the tabs at the top and bottom of the ARC CELL CONNECTOR snap into place, holding it in the ARC CELL CONNECTOR outlet.

Installing the PURIFICATION PLATE:

  1. Holding the PURIFICATION PLATE by the ceramic portion, slowly insert it into the PURIFICATION PLATE slot, ensuring that the PURIFICATION PLATE is sliding into the grooves on either side.
  2. NOTE: About halfway in, the PURIFICATION PLATE connectors are parted. Continue sliding the PURIFICATION PLATE into the PURIFICATION PLATE slot until there is approximately one inch of the PURIFICATION PLATE remaining outside of the PURIFICATION PLATE slot and significant resistance is met. Be careful not to force the PURIFICATION PLATE further into the PURIFICATION PLATE slot as this could seriously damage your unit.

ASSEMBLY (Continued)

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

[Notice] Refer to the Diagram Section (Pg. 5-6) for further illustrations of part names and locations.

Installing the FILTER ASSEMBLY:

  1. Hold the FILTER ASSEMBLY with the larger flat side (where the honeycomb layer of the filter is visible) facing the interior of the unit.
  2. Insert the bottom of the FILTER ASSEMBLY into the tabs on the rear of the unit and then seat the FILTER ASSEMBLY on the rear of the unit. (NOTE: If the user fails to insert the FILTER ASSEMBLY into the tabs appropriately, disassembling the unit in the future could be extremely difficult.)
  3. Screw the two BRASS THUMBSCREWS into their holes at the top corners of the FILTER ASSEMBLY.

Installing the REAR COVER:

  1. Place the tabs at the top of the REAR COVER into the holes above the top of the FILTER ASSEMBLY then swing the REAR COVER flat against the rear of the unit and press until the tabs on the inner sides of the REAR COVER click into place in the unit.
  2. Carefully insert the REAR COVER SCREW into its hole on the REAR COVER (above the POWER CORD Port) and tighten.

Installing the POWER CORD:

  1. Insert the DC POWER ADAPTER PLUG into the rear of the unit.
  2. Ensure the POWER CORD is properly connected to the DC POWER ADAPTER.
  3. Insert the POWER CORD PLUG into a wall outlet.

Turning the unit ON:

  1. Press the POWER BUTTON.
  2. The unit will be set to NORMAL MODE (ARC) once again. Ensure that the unit's settings are adjusted to suit your preferences (see “CONTROLS" on page 11).

CLEANING

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

Review the Disassembly and Assembly Section (Pg. 12-15) before performing and cleaning and maintenance to prevent damage to the unit.

Your unit should be cleaned at least monthly to keep it running at peak performance, but more often if its operating environment is heavily contaminated.

Cleaning the Unit (Exterior):

Wipe down the exterior with a damp cloth or use compressed air or a vacuum to remove dust.

Cleaning the FILTER ASSEMBLY

You may use clean water or compressed air to clean your FILTER ASSEMBLY once it has been disassembled (see “DISASSEMBLY” on page 12). After disassembling your unit, the three filters (mesh, foam, and honeycomb) should be removed and cleaned separately. If using water, you must allow the filters to dry separately before reassembly. When reassembling, the Honeycomb Filter goes in first, then the Foam Filter, and finally the thin Mesh Filter. Lastly, reattach the rim to the FILTER ASSEMBLY.

Cleaning the IONIZATION NEEDLE

Using a cotton swab, apply a small amount of clear alcohol-based cleaner (or rubbing alcohol) to the IONIZATION NEEDLE. You may also use compressed air to blow off any dust that may accumulate near the IONIZATION NEEDLE.

Cleaning the ARC CELL

ARC Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. DO NOT handle if broken or hot.

Using a compressed air or a vacuum cleaner, blow and/or vacuum the dust out of the ARC CELL. Do not use any liquid to clean the ARC CELL. Do not disassemble the ARC CELL.

Cleaning the PURIFICATION PLATE

Using white vinegar or a solution of equal parts warm water and clear ammonia, soak the PURIFICATION PLATE for 8-10 hours but do not exceed 12 hours. Using a soft-bristle brush, scrub the wire mesh to remove debris. Rinse thoroughly. Allow the PURIFICATION PLATE to dry completely before reinstalling. Use a soft cloth and rubbing alcohol to clean the contacts on the interior of the unit that touch the PURIFICATION PLATE.

Cleaning the Unit (Interior)

Using a damp cloth, a clear alcohol-based cleaner, compressed air or a vacuum cleaner, carefully clean the walls and components inside of the unit only after completing the disassembly procedures found in DISASSEMBLY on pages 12 - 13.

Resetting the “PERFORM CLEANING” Maintenance Reminder

To reset the “PERFORM CLEANING” maintenance reminder, press and hold the REMINDER RESET BUTTON until the reminder goes away. It will return after 30 days of use.

TROUBLESHOOTING

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

The unit fails to turn on

  1. Verify that the POWER PLUG is plugged into an operational wall outlet.
  2. Ensure that the POWER CORD is fully inserted (leaving less than an 1/8") into the DC POWER ADAPTER and the green light on the DC POWER ADAPTER is illuminated.
  3. Ensure that the DC POWER ADAPTER PLUG is fully seated in the DC POWER ADAPTER INLET.
  4. Verify the POWER BUTTON has been activated on the CONTROL PANEL.
  5. If the POWER BUTTON on the CONTROL PANEL fails, use the POWER BUTTON on the REMOTE CONTROL. If the CONTROL PANEL fails, contact your dealer or go to www.GreenTechEnv.com/Support.

No noticeable activated oxygen (ozone) is being produced in HIGH MODE or AWAY MODE

  1. Ensure that the PURIFICATION PLATE is clean. (See “CLEANING" on page 16)
  2. The PURIFICATION PLATE may not be working because it needs to be replaced. Try installing a new PURIFICATION PLATE.
  3. Check the electrical contact arms which touch the plate to ensure that they are making proper contact with the metal mesh on the PURIFICATION PLATE.
  4. Ensure the electrical contact arms which touch the plate are clean. Clean them with a soft cloth and rubbing alcohol.
  5. Turn the lights off in the room and look through the FRONT GRILLE at the PURIFICATION PLATE. When it is operating properly, the PURIFICATION PLATE will produce a dim purple glow.

The PURIFICATION PLATE generates an electrical arc, an arcing noise or a burning odor

This means the PURIFICATION PLATE is damaged and must be replaced. To order a replacement, contact your dealer or go to www.GreenTechEnv.com/Support.

The ARC CELL is not lighting up:

ARC Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. DO NOT handle if broken or hot.

  1. Ensure the ARC CELL CONNECTOR is properly seated in the ARC CELL CONNECTOR outlet (see “DISASSEMBLY” on pages 12 - 13).
  2. If the ARC CELL still fails to operate, it needs to be replaced. Contact your dealer or go to www.GreenTechEnv.com/Support.

TROUBLESHOOTING (Continued)

The unit should be powered OFF and the POWER CORD disconnected whenever cleaning or servicing.

The IONIZATION NEEDLE creates an electrical arc:

The IONIZATION NEEDLE needs to be cleaned. Using a cotton swab soaked with rubbing alcohol, gently clean around the IONIZATION NEEDLE.

The fan does not operate properly:

  1. Try adjusting the fan speed using the CONTROL PANEL or REMOTE CONTROL.
  2. Remove the FRONT GRILLE (see “DISASSEMBLY” on page 13) to ensure there are no obstructions to the movement of the fan.
  3. If the Fan continues to operate improperly or not at all, contact your dealer or go to www.GreenTechEnv.com/Support.

The unit makes a rattling noise when taken out of packaging:

ARC Cell contains Hg (Mercury) and should be disposed of according to disposal laws. Find disposal centers at www.earth911.org. DO NOT handle if broken or hot.

Remove the REAR COVER of the unit. Check to ensure the two BRASS THUMBSCREWS holding the FILTER ASSEMBLY are in their proper place. If they are properly installed, remove the THUMB SCREWS and FILTER ASSEMBLY and check the ARC CELL to ensure the two ARC CELL RETAINING NUTS securing the ARC CELL are installed properly. Both the BRASS THUMBSCREWS and ARC CELL RETAINING NUTS can work themselves loose during shipment and storage of the unit.

LIMITED WARRANTY INFORMATION

Your pureAir 3000 Whole Home Air Purifier (Product) is warranted to be free from all defects in material and workmanship in normal household use for a period of 1 Year from date of purchase. The warranty is granted only to the original purchaser. The warranty is subject to the following provisions:

Any damages or malfunctions caused by negligence, abuse, or use not in accordance with the Product Owner's Manual are not covered by this warranty. Likewise, any defects or damages caused by unauthorized service or the use of other than Genuine GreenTech Environmental Parts are not covered.

GreenTech Environmental will, at its option, repair or replace a defective Product or part(s) for the Product that is/are covered by this warranty. As a matter of warranty policy, GreenTech Environmental will not refund the customer's purchase price.

OBTAINING WARRANTY SERVICE

To obtain warranty service you must return the defective product along with proof of purchase to a GreenTech Environmental Authorized Service Center. All shipping costs submitted under this Warranty shall be borne by purchaser. Unless this Warranty is expressly renewed or extended by GreenTech Environmental, any repaired or replaced part of product shall be warranted to the original purchaser only for the length of the unexpired portion of the original warranty. For the location of the nearest GreenTech Environmental Authorized Service Center or for other service information, please visit us online at:

www.GreenTechEnv.com

Before any product is sent for service, the customer should contact the GreenTech Environmental Service Center to obtain a Return Merchandise Authorization (RMA) Number. This RMA Number should be clearly written on the box before shipping. All components/parts including the remote (if applicable), power adapter, and original packaging should be included in the return if available.

FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS

Any warranty that may be implied in connection with your purchase or use of the Product, including any warranty of merchantability or any warranty for Fitness For A Particular Purpose is limited to the duration of this warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.

Your relief for the breach of this warranty is limited to the relief expressly provided above. In no event shall GreenTech Environmental be liable for any consequential or incidental damages you may incur in connection with your purchase or use of the Product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

REGISTRATION

Please register your Product within 10 days of purchase by visiting:

www.GreenTechEnv.com/Warranty

Registering your new pureAir 3000 Whole Home Air Purifier entitles you to the most up-to-date GreenTech Environmental warranty and information.

Models: 3000 Active Air Purifier, Active Air Purifier, Air Purifier

File Info : application/pdf, 20 Pages, 1.76MB

60de9098-eac9-466e-8688-0fb544873cd3

References

Adobe InDesign 16.0 (Macintosh) Adobe PDF Library 15.0

Related Documents

Preview PureAir 50 Air Purifier: Clean Air for Small Spaces
Discover the PureAir 50 by GreenTech Environmental, a compact and powerful air purifier utilizing Ionization and Activated Oxygen technology to eliminate odors, bacteria, viruses, and allergens in small spaces like closets, bathrooms, and offices.
Preview pureAir 50 Plug-In Ion Generator Air Purifier | GreenTech Environmental
Discover the pureAir 50, a compact and powerful plug-in air purifier from GreenTech Environmental. Effectively reduces odors, bacteria, viruses, smoke, and mold with Activated Oxygen and Ionization. Ideal for bedrooms, bathrooms, and travel.
Preview pureAir 50 Air Purifier Owner's Manual
Comprehensive owner's manual for the pureAir 50 small room air purifier by GreenTech Environmental, covering setup, cleaning, maintenance, specifications, and warranty information.
Preview pureAir 50 Air Purifier Owner's Manual | GreenTech Environmental
Get started with your pureAir 50 air purifier. This manual from GreenTech Environmental covers setup, operation, cleaning, specifications, and warranty information for the GTEPA-50 model.
Preview pureAir 50 Air Purifier Owner's Manual | GreenTech Environmental
Official owner's manual for the pureAir 50 small room air purifier by GreenTech Environmental. Learn about setup, cleaning, maintenance, specifications, and warranty.
Preview pureAir 50 Air Purifier Owner's Manual | GreenTech Environmental
Owner's manual for the pureAir 50 small room air purifier by GreenTech Environmental. Includes setup, cleaning, specifications, and warranty information for a cleaner living space.
Preview GreenTech Environmental Product Catalog: Air Purifiers, Heaters, Fans, and Laundry Systems
Official product catalog from Essco featuring GreenTech Environmental's range of advanced air purifiers, including pureAir SOLO, pureAir 3000, and pureAir Active HEPA+ models proven against SARS-CoV-2. Also includes pureWash laundry systems, pureFlow fans, and pureHeat/pureComfort heaters. Find product specifications, Essco part numbers, and model details.