User Manual for VISSONIC models including: VIS-CATC-B, VIS-CATC-B Camera Auto Tracking Controller, Camera Auto Tracking Controller, Auto Tracking Controller, Tracking Controller, Controller

VIS-CATC-B Camera Auto tracking controller user manual 2.3

User

Auto tracking controller user manual ...

VIS-CATC-B Camera Auto tracking controller user manual 2.3


File Info : application/pdf, 16 Pages, 1.47MB

PDF preview unavailable. Download the PDF instead.

VIS-CATC-B Camera Auto tracking controller user manual v2.3
VIS-CATC-B Camera Auto tracking controller User Manual
V2.3
VISSONIC ELECTRONICS LIMITE

www.vissonic.com
The meaning of symbols
 Safety instructions For your safe and correct use of equipment, we use a lot of symbols on the equipment and in the manuals, demonstrating the risk of body hurt or possible damage to property for the user or others. Indications and their meanings are as follow. Please make sure to correctly understand these instructions before reading the manual.
This is A level product, which may cause radio interference in the living environment. In this case, users may need to take the feasible measures to get around the interference. Remind users that the dangerous voltage without insulation occurring within the equipment may cause people suffer from shock. CE certification means that the product has reached the directive safety requirements defined by the European Union. Users can be assured about the use of it. SGS certification means that the product has reached the quality inspection standards proposed by the world's largest SGS. This product passed the ISO9001 international quality certification (certification body: TU Rheinland, Germany). Warning: in order to avoid electrical shock, do not open the machine cover, nor is the useless part allowed to be placed in the box. Please contact the qualified service personne
 General information instructions
It lists the factors leading to the unsuccessful operation or set and the relevant information to pay attention.

Important note

www.vissonic.com

Warning In order to ensure the reliable performance of the equipment and the safety of the user, please observe the following matters during the process of installation, use and maintenance:
The matters needing attention of installation  Please do not use this product in the following places: the place of dust, soot and electric
conductivity dust, corrosive gas, combustible gas; the place exposed to high temperature, condensation, wind and rain; the occasion of vibration and impact . Electric shock, fire, wrong operation can lead to damage and deterioration to the product, either;  In processing the screw holes and wiring, make sure that metal scraps and wire head will not fall into the shaft of controller, as it could cause a fire, fault, or incorrect operation;  When the installation work is over, it should be assured there is nothing on the ventilated face, including packaging items like dust paper. Otherwise this may cause a fire, fault, incorrect operation for the cooling is not free;  Should avoid wiring and inserting cable plug in charged state, otherwise it is easy to cause the shock, or electrical damage;  The installation and wiring should be strong and reliable, contact undesirable may lead to false action;  For a serious interference in applications, should choose shield cable as the high frequency signal input or output cable, so as to improve the anti-jamming ability of the system.
Attention in the wiring  Only after cutting down all external power source, can install, wiring operation begin, or it
may cause electric shock or equipment damage;  This product grounds by the grounding wires .To avoid electric shocks, grounding wires and
the earth must be linked together. Before the connection of input or output terminal, please make sure this product is correctly grounded;  Immediately remove all other things after the wiring installation. Please cover the terminals of the products cover before electrification so as to avoid cause electric shock.
Matters needing attention during operation and maintenance  Please do not touch terminals in a current state, or it may cause a shock, incorrect operation;  Please do cleaning and terminal tighten work after turning off the power supply. These
operations can lead to electric shock in a current state;  Please do the connection or dismantle work of the communication signal cable , the
expansion module cable or control unit cable after turning off the power supply, or it may cause damage to the equipment, incorrect operation;  Please do not dismantle the equipment, avoid damaging the internal electrical component;  Should be sure to read the manual, fully confirm the safety, only after that can do program changes, commissioning, start and stop operation.
Matters needing attention in discarding product  Electrolytic explosion: the burning of electrolytic capacitor on circuit boards may lead to
explosion;  Please collect and process according to the classification, do not put into life garbage;  Please process it as industrial waste, or according to the local environmental protection
regulations.

www.vissonic.com

Preface
This manual mainly describes the use, performance parameters and troubleshooting of VISSONIC Full Digital Network DSP Conference System - including desktop, embedded, array unit and 5G WiFi wireless conference system.

If the technical parameters and system usage in this manual are changed, the manufacturer will update the version of the manual. Please use the latest user manual.

The copyright of the manual belongs to VISSONIC ELECTRONICS LIMITED. This manual is protected by the Copyright Law of the People's Republic of China and other intellectual property laws and regulations. Without permission, it is not allowed to copy part or all of the manual or modify this manual.

Version Update

Date

1.0

Publish

2018.12.28

2.0

Update interfaces and functions

2021.12.07

2.1

Update screen split function

2022.05.07

2.2

Update screen split function and camera tracking

2022.08.01

2.3

Update network control protocol

2023.11.23

www.vissonic.com
Content
1. Overview........................................................................................................................................6 1.1.Function .............................................................................................................................. 6 1.2.Main Specifications.............................................................................................................6 1.3.VIS-CATC-B camera tracking seamless switching controller front and rear panel function
description ......................................................................................................................................... 6 1.4.Installation ........................................................................................................................... 7 1.4.1.19-inch installation cabinet ...................................................................................... 7 1.5.Connection .......................................................................................................................... 8 1.5.1.Power supply............................................................................................................8 1.5.2.RS-232 control interface .......................................................................................... 8 1.6.Network control protocol .................................................................................................. 11 1.7.Web Control ...................................................................................................................... 11
2.System connection diagram ......................................................................................................... 14 2.1.Camera RS232 cascade control line connection method .................................................. 14 2.2.Full Digital Network DSP Conference Controller CAMERA Menu--Camera Tracking
Settings............................................................................................................................................ 14
5

1. Overview

www.vissonic.com

1.1. Function

This device mainly has 4-channel high-definition SDI input, 2-channel high-definition HDMI input, 1-channel RCA audio input, 2-channel high-definition HDMI output, 1-channel USB output, which can realize seamless switching, screen splitting and audio switching, convenient operation, and support buttons, RS232 control and Ethernet control.
1.2. Main Specifications

The main technical indicators of the camera tracking controller are as follows:
Video input port: 4-channel SDI HD interface; (SDI supports 3G-SDI and HD-SDI; supports digital audio input) Video input port: 2-channel HDMI HD interface; (HDMI supports 1080P60Hz downward compatibility; supports digital audio input) Video input port: 1-channel RCA audio interface;(analog audio)
Video output port: 2-channel HDMI HD interface; (HDMI supports 1080P60Hz downward compatibility; supports up to four screen splits output; supports audio output) Video output port: 1-channel USB interface; (The USB port supports 1080P30Hz, and the USB can be output to the computer, which is equivalent to the function of the capture card. It mainly captures the signal synthesized by the RCA input and the SDI or HDMI video signal; supports up to four-screen split output) Input impedance: 75;
a) Remote control interface: 2-way RS232 serial port; 1-way RJ45 Ethernet interface;(Support web control)
b) Local control interface: support local button control (buttons are deployed on the front panel); c) Power interface: 1 AC power interface; d) Power supply: rated AC100 ~ 240V; e) Dimensions: 19-inch rack cabinet, height 1U, depth 260mm (without panel); f) Color spray: black; g) Weight:  3.5kg; h) Power consumption: 8W.
1.3. VIS-CATC-B camera tracking seamless switching
controller front and rear panel function description

6

www.vissonic.com
Figure 1.3 VIS-CATC-B the front and rear panels The front panel of camera tracking includes:  Power switch - turn the power of the camera tracking controller on or off  Control button - 1 - 6 button corresponds to 1 - 6 HDMI and SDI input channels, can switch
any 1 HDMI or SDI input signal to HDMI output  Input signal indicator - 1 - 6 indicator corresponds to 1 - 6 HDMI and SDI input channels  Audio input port - support 1 RCA interface balance audio input  Input port - support 2 channels of high-definition HDMI and 4 channels of high-definition
SDI signal input  Output port - support 2 channels of high-definition HDMI signal synchronization output and
1 channel USB signal output  Control port - RS-232 female, RS-232 male and RJ45 Ethernet is used to connect the full
digital network DSP conference controller for video switching control of camera tracking or connect the computer for control  Power input port - connect the camera tracking controller to the power sequencer or plug-in with the power cable to supply power to the camera tracking controller *(HDMI and SDI input interface supports digital audio input, HDMI and USB output interface supports analog and digital audio simultaneous output)
1.4. Installation
1.4.1. 19-inch installation cabinet
The main unit can be installed in a 19-inch standard cabinet with standard mounting screw holes.
7

www.vissonic.com

1.5. Connection

Figure 1.4.1

1.5.1. Power supply
Connect the main unit to an external power outlet using the supplied power cord.

Figure 1.5.1
1.5.2. RS-232 control interface
8

www.vissonic.com

Figure 1.5.2 RS232 female
It is used to connect the digital network DSP conference main unit for video switching control of camera tracking or connect the computer for control.

Pin

Signal

Description

Pin

Signal

Description

1

-

Null

6

-

Null

2

TXD

Send data

7

-

Null

3

RXD

Receive data

8

-

Null

4

-

Null

9

-

Null

5

GND

Signal ground

The COM port pins are defined as follows:

Figure 1.5.3 RS232 male The COM port pins are defined as follows:

Pin

Signal

Description

Pin

1

-

Null

6

2

RXD

Receive data

7

3

TXD

Send data

8

4

-

Null

9

5

GND

Signal ground

Signal -

Description Null Null Null Null

Serial port default settings: Baud rate: 9600bps, Parity: 8, Stop: 1 Serial control command table:

Instruction

Function

Return Information

Remark

[x]V[y].

[x] input to [y] output, video switching
9

V:[x] -> [y]

www.vissonic.com

<#Splice_mode[x]> Multiple image mode selection

<Splice_mode[x]>

[x]:0--11

<#Audio_chn[x]> Audio channel selection

<Audio_chn[x]>

FREEZE[x].

Set the screen freeze time to x seconds

FREEZE[x].

[x]:Unit: second

SetFreeze.

Perform screen freeze

<^NET>

Query network parameters

<SPORT80> <SIPR[X1].[X2].[X3].[X

4]>
<GAR[X1].[X2].[X3].[X 4]> <SUBR[X1].[X2].[X3].[ X4 ]> <SHAR[x1]:[x2]:[x3]:[x

4]:[x5]:[x6]>

<#SIPR[x1].[x2].[x Set IP address

<SIPR:[x1].[x2].[x3].[x4

3].[x4]>

]>

<#GAR[x1].[x2].[x Set gateway

<GAR:[x1].[x2].[x3].[x4

3].[x4]>

]>

<#SUBR[x1].[x2].[ Set subnet mask

<SUBR:[x1].[x2].[x3].[x

x3].[x4]>

4]>

<#SHAR[x1]:[x2]:[ Set hardware address(hex)

<SHAR:[x1]:[x2]:[x3]:[x

x3]:[x4]:[x5]:[x6]>

4]:[x5]:[x6]>

<#NETDEFAULT> Network restore factory settings

10

1.6. Network control protocol

www.vissonic.com

Default IP: 192.168.10.189 Port: 80 Using TCP Connection Pin Menu item Send parameter Return parameter

Description

1

Version {param=version}- {"version"" X" }

X:vierson number

{"out1":X1, "out2":X2,

2

Toggle Status

{param=status}

"out3":X3, "out4":X4, "audio":X1,"mode":X1

}

{"HDMI-1":true/false,

"HDMI-2":true/false,

3

Input Signal Status

{param=inputinfo}

"SDI-1":true/false, "SDI-2": true/false,
"SDI-3":

true/false,"SDI-4":

true/false }

Settings ->

{"ip":"X","gateway":"Y

4 Query Network {param=netInfo} ","subnet":"A","mac":"

Parameters

B" }

{param=&ip,ip=%

5

Settings -> Set Network Parameters

d.%d.%d.%d,gatew ay=%d.%d.%d.%d, subnet=%d.%d.%d. %d,mac=%x:%x:%

Null

x:%x:%x:%x}

6

Settings -> Mode Selection

{param=modeX}

Null

X: 0-11 (Corresponding to Modes 0 to 11)

7

Video Source {param=XVY} Switching

Null

X: Input, Y: Output

8

Audio Switching

{param=audioX}

Null

X: Input Audio (0-6)

1.7. Web Control

Network port default settings: IP: 192.168.10.189 Connect your PC to the Ethernet port of the camera tracking controller via a CAT5 cable. Please set your computer to the following IP range

11

www.vissonic.com
Figure 1.7.1 PC network segment Log in to the web page, enter the IP address 192.168.10.189, and if you can log in to the interface as shown in Figure 6.2, it means that the connection is successful. Click Video and Audio to control the screen segmentation and audio switching of the camera tracking controller. Screen split: as shown below:
Figure 1.7.2 Screen split  Signal list - the video input signal of the camera controller  Multi-image mode - supports up to 12 screen split modes  Display window - After selecting the desired multi-image mode, you can drag and drop various video signals directly on the display window Audio switching: as shown below:
12

www.vissonic.com
Figure 1.7.3 Audio switch  Audio switching - 1-channel analog audio and 6-channel digital audio input can be switched to output arbitrarily Network settings: as shown below:
Figure 1.7.4 Network settings  IP Settings- Modify IP, gateway, subnet mask and MAC View version: as shown below:
Figure 1.7.5 Version  Version- Click About to enter the following interface to view version information
13

2. System connection diagram

www.vissonic.com

2.1. Camera RS232 cascade control line connection method
PIN1......DTR;PIN2......DSR;PIN3......TXD;PIN4......GND;PIN5......RXD;PIN6......GND ;P IN7......IROUT; PIN8......NC
2.2. Full Digital Network DSP Conference Controller CAMERA Menu--Camera Tracking Settings
Enter the menu 'CAMERA' to set the parameters of the camera tracking.
14

www.vissonic.com

Menu Item

Parameter

Parameter value Description

Protocol

-

SAMSUNG, PELCO-D, VISCA, CUSTOM, VCA-UDP

Camera

map

(Note: If you use

the cameras using

SAMSUNG or

PELCO-D

protocol need to

set this menu. Use

VISCA protocol,

no need to set this

menu)

Camera select Camera addr. Video channel UDP addr

001 to 016 Off,001to 255 Off,001 to 255 Off,001 to 255

Freeze Time

-

Video Mode

-

01 to 30 Normal/Recorder

Select the protocol according to the camera model, When the camera tracking controller VIS-CATC-B is used and the protocol needs to be set to 'custom', the camera tracking is processed by VIS-CATC-B without setting the submenus' camera map 'and' start set '
Camera select--select the camera to setup, there totally support 16 cameras.
Camera addr.--set the camera address for the camera selected on submenu 'Camera select'. SAMSUNG and PELCO-D protocols need to set the address, and VISCA protocol is set to off.
Video channel--Bind the camera (which set on submenu 'camera select') to the video channel number of video switcher. (There is no video switcher connected to the main unit for camera tracking by RS232, just set as Off.)
Note: To set next camera, we just repeat the same steps:
'Camera Select->'Camera addr' ->'Video channel'
The main unit will record every time of setup for each camera.
UDP addr--Bind the IP of the network camera, if you choose VCA-UDP protocol control, you need to set the camera IP. The camera tracking host switching screen delay time can be set to 00 seconds to 30 seconds. When using the camera tracking controller or video matrix as the video switching device, select "Normal", and when the recorder is the video switching device, select "Recorder".

Example: Here we have to set up two cameras, using the VISCA, SAMSUNG/PELCO-D or CUSTOM protocol, and using a video switcher or camera tracking controller. Step 1: The lower control port of the CONTROL connected to the conference processor is connected to the camera.

Camera using the VISCA protocol.
15

www.vissonic.com
Camera using SAMSUNG/ PELCO-D Step 2: The upper control port of the conference processor CONTROL is connected with the RS232 port of the camera tracking controller VIS-CATC-B. Step 3: Use the front panel of the conference processor and the camera remote control, keyboard or CLEACON software to set the camera tracking preset position and input the camera information according to the following steps.
16



References

Microsoft Word 2013