User Manual for Foamit models including: MU50-PSGN130, MU100-PSGN130, MU50-PSGN130 1.3 Gallon Air Powered Mist Unit, MU50-PSGN130, 1.3 Gallon Air Powered Mist Unit, Air Powered Mist Unit, Powered Mist Unit, Mist Unit

Mist Unit

PDF preview unavailable. Download the PDF instead.

MU50-PSGN130 and MU100-PSGN130 UserManual
Mist Unit
User Manual
MU50-PSGN130 MU100-PSGN130

MU50-PSGN130

MU100-PSGN130

READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
English (Original Instructions)

Scan this code for user manual

Safety

! WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death. Always depressurize and clean the unit after each use. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion, serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to an alkaline.

NOTICE
Servicing, or modification, of this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit. Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an air lubricator before the unit. Moisture in the air lines may damage the pump and diminish the units life. The air must be filtered, clean, dry and free of moisture. If needed, install an air dryer before the unit.
Only lift and carry unit by the carrying handle. Do not lift or carry the unit by the pump handle, hose, wand, or other components.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.

Model: MU50-PSGN130 | MU100-PSGN130

V20240424 · Page 2 of 7

Product Overview

Requirements
Compressed air requirements Liquid temperature range
Chemical compatibility

40 psi (2.8 bar) with 2-5 cfm (56.6-141.6 l/min)
40-100°F (4.4-37.8°C)
Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact our customer service department.

Specifications

MU50-PSGN130

Power type

Compressed air

Chemical pickup type

Draws from pre-mixed solution

Number of products unit can draw from One product

Capacity

1.3 gallons (5 liters)

MU100-PSGN130 2.6 gallons (10 liters)

Discharge line length/diameter

12 ft. (3.6 m) coiled twin-line tubing ¼ in. (6.4 mm outside diameter), red and blue, with 0.16 in. (4.06 mm) inside diameter

Discharge wand/tip type

Polypropylene trigger handle for liquid output and polypropylene fog/mist nozzle with Kynar tip

Output distance Output volume Flow rate* Pump seals Run time from full tank** Nozzle type

3-4.5 ft. (0.9-1.4 m) 8.8 oz./min. at 40 psi 8.8 oz./min. at 40 psi Viton Approximately 19 minutes Pneumatic fog nozzle

Approximately 38 minutes

Number of nozzles

One

* Dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings. ** Area covered and run time may vary based on humidity, air flow, and product used.

Model: MU50-PSGN130 | MU100-PSGN130

V20240424 · Page 3 of 7

Product Components
Get to know the components that you will need to use, adjust or assemble.

1

45 6

7

2 3

8

9

10

11

12

MU50-PSGN130

1. PSGA-PNZ wand 2. Air discharge shut-off valve 3. Pressure relief valve 4. Discharge hose 5. Air supply hose 6. Pump handle

7. Air gauge 8. Pressure reducing valve 9. 5 liter tank 10. 10 liter tank 11. Air inlet shut-off valve 12. Air fitting

Model: MU50-PSGN130 | MU100-PSGN130

MU100-PSGN130
V20240424 · Page 4 of 7

Using your unit
Operating Instructions
1. Ensure all air pressure is released from unit by pulling the pressure relief valve stem out.
2. Securely hold the unit and unscrew the pump assembly from the tank in a counterclockwise direction.
3. Follow all instructions from chemical manufacturer. Fill tank 3/4 of the way with pre-mixed solution.
Note: Do not overfill tank with solution.
4. Securely hold the tank and screw the pump assembly back on in a clockwise direction.
5. With the air discharge shut-off valve (a) and air inlet shut-off valve (b) in the closed position, plug an air supply line into the air fitting. The pressure is regulated to 40 psi (2.8 bar) with the pressure reducing valve.
Note: The pressure relief valve will leak if the air pressure is too high. Do not overfill tank with air.
6. Point the discharge wand in a safe direction and open the air discharge shut-off valve (a) and air inlet shut-off valve (b). Then squeeze the trigger handle to begin misting.
Note: Both air valves should be completely open while misting.
7. To stop misting, release the trigger handle and close the air discharge shut-off valve (a).
After Use Instructions
8. Disconnect the airline from the air fitting. Release air pressure from unit after each use by activating the pressure relief valve.
9. Flush the unit with fresh water. It is recommended to always empty out remaining solution and run fresh water through the unit to rinse all parts thoroughly after each use and before storage.

6
7 4
2 1
a b5 3 5

Model: MU50-PSGN130 | MU100-PSGN130

MU100-PSGN130
V20240424 · Page 5 of 7

Parts

CTB14-12

PSGA-PNZ

QF1214 LC-PA QFEL14P LC-PRV

PSG12
LC-HNDL-CLP CV14QF-S

PR40 PR40-BRKT TANK10L QFSOV14 TB14BL-PU
QFF14 AP

GRDA-PNZ PNZ-N130

TANK5.0L

Model: MU50-PSGN130 | MU100-PSGN130

V20240424 · Page 6 of 7

Item number AP14 CTB14-12 CV14QF-S GRDA-PNZ LC-HNDL-CLP LC-PA PNZ-N130 PR40 PR40-BRKT
PSG12
PSGA-PNZ QF1214 QFEL14P QFF14 QFSOV14 TANK5.0L TANK10L TB14BL-PU

Description Air fitting - 1/4 in. MPT quick disconnect hose coupling plug - nickel-plated brass 1/4 in. od coiled twin line bonded blue and red tube - polyurethane - 12 ft. reach 1/4 tube x 1/4 tube chk quick fit - small Guard assembly - for pneumatic nozzle - includes 2 guard halves and hardware Tank handle for 5L/10L - with clips Manual pump assembly for 5L/10L - Viton Pneumatic mixing nozzle - polypropylene body - blue kynar tip - 3.7 gal/hr Pressure reducing valve - 40 psi Bracket for PR40 Poly spray gun with 2x 1/2 in. straight thread - gray handle with red clip - 316SS internal spring includes 2x o-ring Poly spray gun assembly - with 1x PZN-N130 pneumatic nozzle - includes nozzle guard Quick fit - 1/2 MPT x 1/4 od tube - polypropylene Fixed elbow 1/4 in. tube x 1/4 in. MPT - polypropylene Female adapter 1/4 in. tube x 1/4 in NPTF polypropylene Shut off valve 1/4 in. tube - polypropylene 5 liter tank 10 liter tank 1/4 in. od blue tube - polyurethane - available per ft.

Model: MU50-PSGN130 | MU100-PSGN130

V20240424 · Page 7 of 7


Adobe PDF Library 17.0 Adobe InDesign 20.2 (Windows)