Instruction Manual for MEAN WELL models including: XLC-40-MA, XLC-40-MAS, XLC-40-MA Multiple Stage Constant Power LED Driver, XLC-40-MA, Multiple Stage Constant Power LED Driver, Stage Constant Power LED Driver, Constant Power LED Driver, Power LED Driver, LED Driver
File Info : application/pdf, 8 Pages, 185.84KB
DocumentDocument40W Multiple-Stage Constant Power LED Driver XLC-40-MA series User's Manual XLC-40-MAS Series (Independent type) XLC-40-MA Series (Built-in type) 110 for XLC-40 MAS series M M EL DC Input: 176-280 VDC SELV Features Constant power mode output with multiple stage selectable by DIP switch Plastic housing with class II and PFC design Flicker free, complying with CE ErP directive Standby power consumption <0.5W Meet emergency lighting (EL) function application Minimum dimming level 0.5% Matter over thread, Matter 1.3 specification 5 years warranty Note.10 Applications Recessed Light Down Light Panel Light Commercial Lighting Decorative Lighting Matter wireless Lighting GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx Description XLC-40-MA series is a 40W with constant power output LED driver . It can operate from 100~305VAC and output current ranging between 600 mA to 1400 mA selectable by DIP switch . Thanks to high efficiency up to 88%, it is able to operate for -25~90 case temperature under free air convection. XLC40-MA series is designed based on latest safety regulations with Matter wireless dimming.It provides more flexibility for LED Lighting application. Model Encoding XLC - 40 - H - MA Type MA MAS Blank: without strain-relief (Built-in type) Casing type: S: with strain-relief (Independent type) Function options :Matter wireless dimming Rated output voltage (H-type) Rated wattage Series name Function Output current selectable by DIP switch, without strain-relief (Built-in type) Output current selectable by DIP switch, with strain-relief (Independent type) Note In stock In stock File Name:XLC-40-MA-SPEC 2025-02-24 40W Multiple-Stage Constant Power LED Driver XLC-40-MA series SPECIFICATION MODEL XLC-40-H-MA OPEN CIRCUIT VOLTAGE Note.2 60V DEFAULT CURRENT CURRENT ADJ.RANGE (BY DIP SWITCH) 1050mA 0.6~1.4A OUTPUT CONSTANT CURRENT REGION RATED POWER Note.3 9~54V Note.4 40W CURRENT RIPPLE <4%(@full load) CURRENT TOLERANCE ±5% DIMMING RANGE 0~100% SETUP, RISE TIME Note.5 2500ms, 100ms/230VAC, 2500ms, 100ms/115VAC VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR 100 ~ 305VAC 141 ~ 400VDC 47 ~ 63Hz PF0.97/115VAC, PF0.95/230VAC, PF0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) TOTAL HARMONIC DISTORTION THD<10%(@load50%/230VAC; @load75%/277VAC), THD<15%(@load50%/115VAC) (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section) EFFICIENCY (Typ.) INPUT AC CURRENT Note.6 88% 0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC INRUSH CURRENT(Typ.) COLD START 10A(twidth=100s measured at 50% Ipeak) at 230VAC; Per NEMA 410 MAX. No. of PSUs on 16A CIRCUIT BREAKER 51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT <0.75mA / 277VAC STANDBY POWER CONSUMPTION Note.7 Standby power consumption<0.5W(Dimming off) PROTECTION SHORT CIRCUIT OVER TEMPERATURE Hiccup mode, recovers automatically after fault condition is removed Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed. WORKING TEMP. Tcase=-25 ~ 90 (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) MAX. CASE TEMP. Tcase=90 ENVIRONMENT WORKING HUMIDITY STORAGE TEMP., HUMIDITY 20 ~ 90% RH non-condensing -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT ±0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384, GB/T 19510.1, GB/T 19510.213, EAC TP TC 004; CSA C22.2 No. 250.13-12 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13; WITHSTAND VOLTAGE I/P-O/P: 3.75KVAC ISOLATION RESISTANCE I/P-O/P: >100M Ohms / 500VDC / 25/ 70% RH EMC EMISSION Parameter Conducted Radiated Harmonic Current Standard BS EN/EN55015(CISPR15) ,GB/T 17743 BS EN/EN55015(CISPR15) ,GB/T 17743 BS EN/EN61000-3-2 , GB17625.1 Test Level/Note --------Class C @load50% SAFETY & EMC Voltage Flicker BS EN/EN61547 Parameter BS EN/EN61000-3-3 Standard ----Test Level/Note ESD BS EN/EN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EMC IMMUNITY EFT/Burst BS EN/EN61000-4-4 Level 2 Surge BS EN/EN61000-4-5 Level3, 1KV/Line-Line Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 2 Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10 period, 0% residual voltage for 0.5 periods OTHERS MATTER STANDARD FLICKER MTBF DIMENSION Matter 1.3 Specification Note.8 PstLM 1, SVM 0.4 3935.2 K hrs min. Telcordia SR-332 (Bellcore); 147*40*32mm,107*40*32mm (L*W*H) 342.9 Khrs min. MIL-HDBK-217F (25) PACKING 193g; 60pcs/12.58Kg/0.58CUFT(for blank type); 210g; 50pcs/11.5Kg/0.57CUFT(for S-type) NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature. 2. Output hiccups under no-load condition. 3. Please refer to DRIVER METHODS OF LED MODULE. 4. De-rating may be need under low input voltages. Please refer to STATIC CHARACTERISTIC sections for details. 5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time. 6. Efficiency is measured at 800mA/50V output set by dip-switch. 7. Standby power consumption is measured at 230VAC. 8. Flicker is measured at full load with LED modules. 9. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf) 10. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1 11. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less. 12. The ambient temperature de-rating of 3.5/1000m with fanless models and 5/1000m with fan models for operating altitude higher than 2000m(6500ft). 13. For more information, please contact with MEAN WELL sales. Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:XLC-40-MA-SPEC 2025-02-24 40W Multiple-Stage Constant Power LED Driver XLC-40-MA series BLOCK DIAGRAM EMI FILTER I/P & RECTIFIERS POWER SWITCHING O.L.P. PWM&PFC CONTROL RECTIFIERS & FILTER O.T.P. DC to DC CURRENT & VOLTAGE LIMIT DETECTION CIRCUIT Fosc : 90KHz +V -V MATTER MODULE DRIVING METHODS OF LED MODULE I-V Operating Area XLC-40-H-MA For 40W application 60V 55V 600mA, 54V 700mA, 54V 50V 45V 40V 1050mA, 38V 35V 1400mA, 28.6V 30V 25V 20V 15V 10V 600mA, 9V 5V 1400mA, 9V 0V 400mA 500mA 600mA 700mA 800mA 900mA 1000mA 1100mA 1200mA 1300mA 1400mA 1500mA CONSTANT POWER TABLE XLC-40-H-MA is a multiple-stage constant power driver, selection of output current through DIP switch is exhibited below. Vo Io DIP S.W 1 2 3 9~54V 600mA ---- ---- ---- 9~54V 700mA ---- ---- ON 9~50V 800mA ---- ON ---- 9~45V 900mA ---- ON ON 9~38V 1050mA(default) ON ---- ---- 9~33V 1200mA ON ---- ON 9~31V 1300mA ON ON ---- 9~29V 1400mA ON ON ON Note: The operating voltage range which show on this table is recommend to use. File Name:XLC-40-MA-SPEC 2025-02-24 40W Multiple-Stage Constant Power LED Driver XLC-40-MA series OUTPUT LOAD vs TEMPERATURE LOAD (%) 100 80 230 VAC 60 110VAC 40 20 -25 -15 0 15 30 40 50 60 70 (HORIZONTAL) AMBIENT TEMPERATURE,Ta () LOAD (%) 100 80 60 40 20 -25 0 20 45 55 65 75 85 90 (HORIZONTAL) Tcase () LOAD (%) STATIC CHARACTERISTIC 100 90 80 70 60 50 40 100 110 130 150 170 190 210 230 250 270 290 305 INPUT VOLTAGE (V) 60Hz De-rating is needed under low input voltage. LIFETIME(Kh) LIFE TIME 120 100 80 60 40 20 0 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Tcase () File Name:XLC-40-MA-SPEC 2025-02-24 THD(%) 40W Multiple-Stage Constant Power LED Driver XLC-40-MA series TOTAL HARMONIC DISTORTION (THD) XLC-40-H-MA Model,Tcase at 75 12 10 8 6 4 2 TBD 115VAC 230VAC 277VAC 0 50% 60% 70% 80% 90% 100% LOAD (1050mA) THD(%) 12 10 8 6 4 TBD 2 115VAC 230VAC 277VAC 0 50% 60% 70% 80% 90% 100% LOAD (1400mA) POWER FACTOR (PF) CHARACTERISTIC XLC-40-H-MA Model,Tcase at 75 1 0.98 0.96 0.94 0.92 0.9 0.88 0.86 TBD 115VAC 230VAC 277VAC 0.84 0.82 0.8 50% 60% 70% 80% 90% 100% LOAD (1050mA) PF 1 0.98 0.96 0.94 0.92 0.9 0.88 0.86 TBD 115VAC 230VAC 277VAC 0.84 0.82 0.8 50% 60% 70% 80% 90% 100% LOAD (1400mA) EFFICIENCY vs LOAD XLC-40-MA series possess superior working efficiency that up to 88% can be reached in field applications. XLC-40-H-MA Model,Tcase at 75 90 85 80 TBD 75 115VAC 70 230VAC 65 277VAC 60 55 50 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% EFFICIENCY (%) 90 85 80 75 TBD 115VAC 70 230VAC 65 277VAC 60 55 50 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD (1050mA) LOAD (1400mA) PF EFFICIENCY (%) File Name:XLC-40-MA-SPEC 2025-02-24 40W Multiple-Stage Constant Power LED Driver XLC-40-MA series MECHANICAL SPECIFICATION XLC-40-MA series Built-in Type 1 2 TB1 107 mm 99 mm tc 1 TB2 2 LED INDICATOR 50.5 mm RESET BUTTON DIP-SWITCH 14.6 mm 1 23 32mm 40mm Case No.XLC-25 Unit:mm Tolerance:±1 TB1 wiring: 8-9mm 0.5-1.50mm2 Terminal Pin No. Assignment( TB1) Pin No. 1 2 Assignment AC/N AC/L Terminal Pin No. Assignment(TB2) Pin No. Assignment 1 +V 2 -V TB2 wiring: 8-9mm 32 mm 0.5-1.50mm2 XLC-40-MAS series Independent Type 1 2 TB1 147 mm 99 mm tc TB2 1 2 LED INDICATOR 50.5 mm RESET BUTTON DIP-SWITCH 14.6 mm 1 23 32mm 40mm Case No: XLC-25-S Unit: mm Tolerance:±1 TB1 wiring: 8-9mm 0.75-1.5mm2 LED indicator Terminal Pin No. Assignment( TB1) Pin No. 1 2 Assignment AC/N AC/L Terminal Pin No. Assignment(TB2) Pin No. 1 2 Assignment +V -V TB2 wiring: 8-9mm 32 mm 0.5-1.5mm2 Flash slowly Flash quickly Constantly ON Constantly OFF Bluetooth Broadcast running Factory Reset running. Matter wireless connected Matter wireless disconnected and Bluetooth Broadcast OFF File Name:XLC-40-MA-SPEC 2025-02-24 40W Multiple-Stage Constant Power LED Driver XLC-40-MA series FACTORY RESET By RESET BUTTON Press and hold the reset button for 10 seconds. When the LED indicator flashes quickly, release the button. The factory reset will then be completed. 1 2 TB1 1 TB2 2 LED INDICATOR RESET BUTTON DIP-SWITCH 1 23 By AC ON/OFF To perform factory reset through AC ON/OFF, the following process must be strictly followed. If the AC ON/OFF process is correct, the output light will flash for 15 seconds. When the flashing stop, it means the factory reset is completed. This operation is consistent with the factory reset effect performed by long-pressing the reset button. AC ON/OFF process to executes factory reset: 1 2 3 4 5 6 7 8 9 10 11 >25s 10-15s >30s 2-5s >30s 10-15s >30s 2-5s >30s 2-5s >30s Phase 1 2 3 4 5 6 7 8 9 10 11 Duration 10-15s >30s 2-5s >30s 10-15s >30s 2-5s >30s 2-5s >30s >25s AC status ON OFF ON OFF ON OFF ON OFF ON OFF ON(should wait until output light stop flashing) If there is a malfunction in the 'AC ON/OFF process', the process can be reset by the following method, starting from stage 1 again. Method 1: AC ON time exceeds 25 seconds Method 2: AC ON times for 2-5s and twice >25s >30s 2-5s 2-5s >30s >30s >30s File Name:XLC-40-MA-SPEC 2025-02-24 40W Multiple-Stage Constant Power LED Driver XLC-40-MA series PLACEMENT Matter device has an integrated antenna for easy integration. In order to maximize the range in every direction, some design guidelines should be taken into consideration when mounting the device. The antenna positions of the device are shown in the figure below: AC Input Antenna location DC Output AC Input Antenna location DC Output Keep the device as far away as possible from vertical metal structures. When the device is mounted on a metal plate, the antenna should not be obscured, and there needs to be a cutout under the antenna to ensure that the RF signal can be transmitted. The device's communication range may be influenced by environmental factors and installation positioning, necessitating on-site adjustments and testing. Installation Manual Please refer to : http://www.meanwell.com/manual.html File Name:XLC-40-MA-SPEC 2025-02-24