PROSiXSHOCK Wireless Shock/Door/Window Sensor

Installation and Setup Guide

The PROSiXSHOCK is a 3-zone wireless shock/door/window sensor designed for use with Honeywell Home controls that support PROSiX™ series devices. It provides:

Typical Shock Protection Area

The typical shock protection area is a 10-12 ft. diameter / 5-6 ft. radius (3.05m – 3.66m diameter / 1.52m – 1.83m radius). The coverage area can vary depending on the mounting surface.

Installation Options

The PROSiXSHOCK can be installed with several options:

Magnet Gap Specifications

Mount the PROSiXSHOCK

  1. To open the device, firmly slide the front and back housings in opposite directions and pull them apart.
  2. The PROSiXSHOCK sensor MUST be mounted as follows:
    • On swinging doors: mount on the upper corner of the door (not the door frame); opposite hinge is ideal.
    • On sliding windows and doors: mount on the frame (on the moving section when the magnet is used).
  3. Mount the sensor as shown, using the double-sided tape and screws provided.
  4. Secure the front cover with the #2 x 1/4" screw.

After enrolling and before mounting, verify adequate signal strength by conducting a sensor test (refer to the controller's instructions) with the device in its intended mounting location. Adjust the device location and orientation as necessary.

Diagram Description: Shows the sensor components, mounting screws, and terminal block connections.

Enroll and Set Up

You must enroll the device in the control. Refer to the control's programming instructions for detailed procedures. Set the controller in Programming Mode and when prompted:

  1. Pull the battery tab to activate the PROSiXSHOCK. (Use the magnet if the battery tab is removed.)
  2. The LED flashes (up to about 20 seconds*) during enrollment.
    • All services (Reed, Terminal Block, and Shock) are enrolled in sequential (or next available) zone numbers.
    • The device sends its unique MAC ID (Serial Number); the controller registers the device and displays the transmitter data on screen.

    *Note: Enrollment time varies depending on the signal strength between the device and the controller.

  3. When done, the LED is ON for 3 seconds to confirm enrollment.

Note: If the device is not successfully enrolled during the enrollment period, the LED turns off and the device powers down. Activate a tamper, wired service (loop), or the reed switch to restart the enrollment process.

  1. Program each zone being used:
    • Reed Switch Zone (loop 1)
    • Terminal Block Zone (loop 2)
    • Shock Zone (loop 3)

After enrolling, verify adequate signal strength by conducting a sensor test (see controller's instructions) with the device in its intended mounting location. Adjust the device location and orientation as necessary.

Diagram Description: Illustrates the enrollment process: 1. Pull battery tab. 2. LED flashes for up to 20 seconds. 3. LED is ON for 3 seconds to confirm enrollment.

Demo Mode (No Enrollment Needed)

  1. Remove the battery pull tab from the device.
  2. Install the mounting plate onto the back cover to ensure both tampers are closed.
  3. The device will attempt to pair with a control (Flashing green LED for ~20 seconds, visible through the top cover).
  4. The Green LED will turn off and within a minute the device is defaulted to maximum shock sensitivity for 10 minutes.
  5. Strike the device in the palm of your hand; the red LED will flash through the front cover indicating a shock event.
  6. When ready to learn the device into a control, open/close the cover again or trip the reed switch using a magnet. The pairing time window will start again.

IMPORTANT: Once enrolled in a system, the PROSiXSHOCK cannot be used with another controller until it is removed from the current controller. See the Controller's instructions for details.

Sensitivity Adjustment

NOTE: The PROSiXSHOCK sensitivity must be set after mounting and enrollment. See the Controller's instructions for details.

The PROSiXSHOCK has the following sensitivity settings: Maximum – Medium – Low – Lowest

  1. Verify the sensitivity setting is adequate by striking the protected surface with the soft part of your fist at the point farthest from the device.
  2. If sensitivity is adequate, the red LED flashes briefly (remove cover for easier viewing of LED). If the LED does not flash, select the next higher sensitivity setting and repeat from step 1.

Diagram Description: Shows sensitivity testing steps: 1. Select sensitivity at the controller. 2. Strike the surface. 3. Observe LED response.

24-Hour Enrollment Deletion and Default

If the device is enrolled in a panel different than the intended panel, and you are unable to delete it from the unintended panel, reset the device to factory default setting:

  1. Open the cover and remove the battery.
  2. Hold down the tamper switch while reinserting the battery. Rapid LED flashing indicates successful deletion (LED flashes as if in enrollment mode). If the LED does not flash, deletion was not successful.
  3. Reattach the cover.

This procedure is available for 24 hours after enrollment with a panel and the device remains powered (battery installed).

Diagram Description: Illustrates the enrollment deletion and default process: 1. Open cover, remove battery. 2. Hold tamper switch, reinsert battery. 3. Reattach cover.

LED Indications

LEDStatus
Rapid Flashes for about 20 seconds, then ON for 3 secondsPower Up – Enrollment
Slow FlashesPower Up – Device enrolled; Wall or Cover Tamper activated. To stop flashes, clear the tamper condition by reconnecting to the mounting plate and reattaching the cover. It also times out after 10 minutes.
ON (while in Programming Mode)Sensor LED toggles on and off when the sensor is selected. See Sensor Location Feature.

Battery Replacement

  1. Push the bottom latch of the mounting bracket back to disengage it. Then slide the back housing up and out to remove it from the mounting bracket.
  2. Slide the front and back housings in opposite directions and pull the housings apart.
  3. Remove the battery, wait 10 seconds, then insert a new battery.
  4. Place the front and back housings together and slide them together.

Recommended batteries: Duracell DL123A, Huiderui CR123A, Panasonic CR123A, Resideo 466.

BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212°F (100°C) or incinerate. Dispose of used batteries properly. Keep away from children.

Note: Constant exposure to high or low temperature or high humidity may reduce battery life.

Diagram Description: Shows battery replacement steps: 1. Disengage mounting bracket. 2. Slide back housing up. 3. Slide housings apart. 4. Remove battery, wait 10 seconds, insert new battery. 5. Slide housings together.

Specifications

Approval Listings

Product must be tested at least once each year.

Federal Communications Commission (FCC) & Industry Canada (IC) Statements

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.

Class B Digital Device Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, as defined by FCC Rules Part 15.105. The Class B Digital Device statement can be viewed at: https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx

FCC/IC Statement

This device complies with Part 15 of the FCC Rules, and Industry Canada's license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d'Industrie Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d'interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable.

RF Exposure

Warning - The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC and ISED multi-transmitter product procedures.

Mise en Garde

Exposition aux Fréquences Radio: La/les antenne(s) utilisée(s) pour cet émetteur doit/doivent être installée(s) à une distance de séparation d'au moins 20 cm (7,8 pouces) de toute personne et ne pas être située(s) ni fonctionner parallèlement à tout autre transmetteur ou antenne, excepté en conformité avec les procédures de produit multi transmetteur FCC et ISED.

Support & Warranty Information

For the latest documentation and support, please go to: www.resideo.com

For the latest warranty information, please go to: www.security.honeywellhome.com/warranty

The Honeywell Home Trademark is used under license from Honeywell International Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.

Resideo
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 2020 Resideo Technologies, Inc.
www.resideo.com

Models: PROSiXSHOCK, Wireless Shock, Wireless Door, Wireless Window Sensor

File Info : application/pdf, 4 Pages, 469.26KB

PDF preview unavailable. Download the PDF instead.

prosixshock-resideo-honeywell-home-proseries-wireless-shock-door-window-sensor-installation-and-setup-guide E727032 Adobe PDF Library 20.6.66

Related Documents

Preview Honeywell Home PROSIXMINI Wireless Door/Window Sensor Installation and Setup Guide
Detailed installation, setup, enrollment, and battery replacement guide for the Honeywell Home PROSIXMINI wireless door/window sensor. Includes specifications and regulatory information.
Preview Honeywell 5819S & 5819SBR Wireless Shock Sensor and Transmitter Installation Guide
Installation and setup guide for the Honeywell Home 5819S & 5819SBR Wireless Shock Sensor and Transmitter. Learn about its features, installation, enrollment, programming, and DIP switch settings.
Preview Honeywell Home PROSiXCT Wireless Door/Window Sensor Installation and Setup Guide
Comprehensive installation and setup guide for the Honeywell Home PROSiXCT wireless door/window sensor, detailing mounting, enrollment, battery replacement, specifications, and compliance information.
Preview Honeywell Home HS3PIR2X PIR Sensor Installation and Setup Guide
Get detailed instructions for installing and setting up your Honeywell Home HS3PIR2X wireless PIR motion sensor. This guide covers planning, mounting, linking to your system, and troubleshooting tips.
Preview Honeywell Home RCHS5200WF Security System Quick Start Guide
Get started with your Honeywell Home RCHS5200WF security system. This guide provides essential setup instructions, system overview, and accessory information from Resideo.
Preview Honeywell Home C7835A1009 Discharge Air Temperature Sensor Installation and Operation
Installation and operation guide for the Honeywell Home C7835A1009 Discharge Air Temperature Sensor (DATS), a duct-mounted probe for HVAC capacity control. Includes wiring, troubleshooting, and resistance cross-reference.
Preview Honeywell Home THX9321/THX9421 Prestige System Installation Guide
This document provides a comprehensive installation guide for the Honeywell Home THX9321 Prestige 2.0 and THX9421 Prestige IAQ 2.0 thermostats, including the Equipment Interface Module (EIM) and various RedLINK wireless accessories. It details system setup, wiring diagrams, features, installer options, specifications, and regulatory information.
Preview Honeywell Home CAMIR-8EZS Wireless Motion Sensor with Camera - Installation Guide
Comprehensive installation and setup guide for the Honeywell Home CAMIR-8EZS wireless motion sensor with camera, covering placement, mounting, battery replacement, and web portal connection.