User Manual for HDWR Global models including: AC600 RFID Access Control Reader, AC600, RFID Access Control Reader, Access Control Reader, Control Reader

Serwis

[PDF] User Manual 125kHz RFID Access Control Reader SecureEntry ...

Jun 5, 2024 · SecureEntry-AC600. Page 2. 2. Table of contents. Specifications: ......................................................................

User manual in English SecureEntry-AC600

Access control reader RFID card PIN imprint SecureEntry-AC600


File Info : application/pdf, 20 Pages, 403.48KB

PDF preview unavailable. Download the PDF instead.

SecureEntry-AC600 MANUAL EN 20240605
User Manual
125kHz RFID Access Control Reader
SecureEntry-AC600

Table of contents
Specifications: ............................................................................................................................................................... 3 Set contents: ................................................................................................................................................................... 4 Features: ............................................................................................................................................................................ 4 Introduction..................................................................................................................................................................... 5 Installation........................................................................................................................................................................ 5 Wiring Diagram ............................................................................................................................................................ 6 Drawing Connection Diagram ...........................................................................................................................7 Sound and light signalling...................................................................................................................................10 Admin Menu - Standalone Mode Settings ............................................................................................... 11
Device Management ................................................................................................................. 11 Add and remove users .......................................................................................................................................... 12
Ways to access............................................................................................................................ 13 Advanced settings....................................................................................................................................................14 Reader mode settings............................................................................................................................................16 Admin card support.................................................................................................................................................18 Delete a card.................................................................................................................................................................18 User support...................................................................................................................................................................19 Other operations ........................................................................................................................................................19
2

Specifications:
· Warranty: 1 year · Product type: RFID card, password and fingerprint access
control reader · Material: metal · Processor: 32-bit microprocessor with ARM core · Operating frequency: 125 kHz · Max number of employees in the database: 10,000 · Max. number of fingerprints in the database: 600 · Supported RFID cards: EM · Verification Type: RFID Card, Password, Fingerprint · Access control: yes · Interface: Wiegand 26/34 · Working Voltage: DC 12-24V · Operating Current: 100mA · Standby Current: 35mA · Ingress Protection: IP68 · Keyboard and keys: touch keyboard · Operating Temperature: 0%~95% · Operating Humidity: 5 to 95% · Product dimensions: 13.9 x 5.6 x 2 cm · Package dimensions: 19.3 x 12.6 x 6 cm · Product weight: 500 g · Product weight with packaging: 900 g
3

Set contents:
· RFID Access Control System · Screws and mounting pins · Allen key · Manual
Features:
· The access control reader offers user verification through an RFID card, individual password and fingerprint
· Ability to set a single verification method or a combination of several methods
· IP68 rating ensures water resistance, so the device can be installed outdoors
· The maximum capacity of users in the database is as much as 10,000, which makes the reader ideal equipment for large companies
· 126 kHz operating frequency and Wiegand 26 and Wiegand 34 interface
· Possibility to connect the reader with a time and attendance recorder, electronic and electromagnetic door lock, intercom, videophone and other external devices with DC 12-24V voltage
4

Introduction
The product in this series is a new generation of multifunctional autonomous access control. It uses a 32-bit microprocessor with an ARM core, which is efficient, stable and reliable. It includes reader mode and stand-alone access control mode, etc. Widely used in various situations, such as offices, residential communities, villas, banks, etc.
Installation
· Remove the back cover of the device using the special screwdriver provided.
· Drill 2 holes in the wall for self-tapping screws and 1 hole for wire.
· Insert the provided rubber plugs into the two holes. · Secure the back cover to the wall using 2 self-tapping
screws. · Pull the cable through the cord hole. · Attach the keyboard to the back cover. (See figure below.)
5

Wiring Diagram
6

Drawing Connection Diagram
1. Shared power supply
Remark. Door contact and alarm function are optional.
7

2. Special power supply Remark. Door contact and alarm function are optional.
8

3. Reader Mode
9

Sound and light signalling

Operation status
Ready for action Operation successful
Operation failed

Light signal
Red
Green

Beep
One longer beep Three short signals

Starting the programming mode via the administrator
tab Disabling Programming Mode via Admin Tab Pressing the number
button Press the * button Enter your access code Card reading in card plus code mode
Multi-user card reading
Entering Programming Mode
Enable Settings Status Unlock
Audible alarm

Red LED flashes slowly Red LED flashes slowly
Red LED flashes slowly
Red LED flashes slowly
Orange Green The red LED flashes quickly

Two short signals One longer beep
One short beep One long beep
Alarm

10

Admin Menu - Standalone Mode Settings
Device Management

Entering Programming
Mode
Press * Admin Code# (By default, the admin code is "999999")

Menu Stages of action Description Default

00 New admin code # new admin code #

Change the admin code

999999

01 Card

Add an

reading/fingerprint admin card

input

or fingerprint

twice*

02 Card

Remove an

reading/fingerprint admin card

input

or fingerprint

twice*

0#

Reader Mode

Self-

1

1# 03

contained access control mode

Switching 2#
relay mode

08

WIFI Matching Optional

09 Unlock code # (4Access code
6 digits)

11

Add and remove users

Entering Programming
Mode
Press * Admin Code# (By default, the admin code is ,,999999")

Menu Stages of action Description Default

Card reading /

Continuous

double fingerprint addition of

entry...*

card users

or

fingerprints

Entering the 8 or 10 Add card

digit card number users by

# ...*

card

number

Entering the ID

Add card or

number, reading fingerprint

the card, entering users by a

11

the fingerprint

specific ID

times ...*

Enter ID number # enter 8 or 10 digit card number # ...*
Enter ID number # enter code # ...*

Add cardholders by specific ID and card number Add independent

,,..." Means repetition Previous Operation
Press* to exit.

user code

by a specific

ID number

Read user card,

Matching

enter the first

Fingerprints

fingerprint twice, to Card 12
enter the second (Maximum

fingerprint twice of 2

Fingerprints)

Enter ID number # Adding a

Enter 8 or 10 digit master card

13

card number #

with a

Enter number of number

cards #

12

Delete users Card reading/fingerprint input ...*
21 Please enter your 8 or 10 digit card number...*
Enter ID number #
000# 20

Remove card users by read card / Delete fingerprints by entering a fingerprint Delete card users by card number Delete users by ID Delete all users

,,..." Means repetition Previous Operation
Press* to exit.

Ways to access

Entering Programming Mode
Press *Admin Code# (By default, the admin code is ,,999999")

Menu 31

Stages of action

Description Default

0 #

Door locked

1 #

Code only entry

2 #

Card-only entry

Entry via card +

3 #

password or

fingerprint + code

Entry by card,

4 #

fingerprint or

4

code

Fingerprint-only 5 #
entry

Fingerprint + card 6 #
entry

Multi-

7 #

fingerprint/multi-

card entry

13

Door opening

1#

setting via 1 user

card/

fingerprint

32

Door opening

1

setting by 2-10

2-10 # user

cards/fingerprints

Fingerprints

Advanced settings

Entering Programming
Mode

Menu

41

42
Press *Admin Code# (By default, the admin code is ,,999999")
61

Stages of action
(0-300) #
0 # (1-99) #
0#
1#

Description Default

Door open

time range:

0-300s,

5

0 equals

50ms

Alarm time

setting, 0s

means no

alarm

0

Alarm Time

Range: 1-

99min

Normal

Operating

Mode

External

alarm and

built-in

buzzer

0

will work if

incorrect

operations

are repeated

5

times.

14

The device

will be

locked for 10

minutes

2#

if incorrect

operations

are

performed 5

times

0#

LED Off

62

LED

1

1#

Switching On

Turning off

0#

keyboard

backlighting

Turning on

1#

the keyboard

63

1

backlight

Keyboard

(2-99) #

backlight time: 2-99

sec.

0#

Sound off

64

1

1#

Sound on

15

Reader mode settings

Entering Programming Mode

Menu 00

01

02

03
Press *Admin Code # (By default, the admin code is "999999")
11

21 20

Stages of action

Description Default

New Admin Code # Card reading / double input Fingerprint* Card reading / double input Fingerprint*
0#
1#
2#
Enter your fingerprint twice...* Enter the ID number # Enter your fingerprint twice...* Enter your fingerprint once...* Enter the second fingerprint...* Tap ID number # ... *
0000#

Change the admin code Add an administrator card or fingerprint Remove an administrator card or fingerprint Reader Mode Stand-alone access control mode Switching relay mode Adding user fingerprints continuously Add user fingerprints by specific ID number
Removing user fingerprints continuously

999999
1
"..."means to repeat the previous operation, Press * to exit. to exit.

Delete users by a specific ID number Delete all users

16

Alarm time

0#

setting, 0s

means no

42

alarm

0

Alarm Time

(1-99) # Range: 1-

99min

Set the

51

(0-255) # device

0

number

Wiegand

52

(26-58) # Output:26-58

26

bits

Keyboard

0#

transmission

format 4 bits

8-bit

keyboard

53

1#

0

transmission

format

Virtual card

2#

output

number

17

Admin card support
Read added admin card -> Read first user card -> Read second user card -> ... -> Read admin card again Note: The add tab is used to add tab users continuously and quickly. When reading the card for the first time, you will hear a short beep twice and the LED will illuminate orange. This means that user addition programming has been introduced. When you read the administrator card again, you will hear a long, single beep and the LED will turn red. This means you exit the user addition program. Delete a card
Read Delete Admin Card -> Read First User Tab -> Read Second User Tab -> ... -> Read Admin Tab Again Note: The Delete Card feature is used to continuously and quickly delete user cards. When reading the administrator card, you will hear a short beep twice and the LED will light up amber, indicating that the user has been removed. When you read the administrator card again, you will hear a long, single beep and the LED will turn red, indicating that you are out of the user delete settings program.
18

User support
1. Change your user code with a card
Press * -> read card -> enter old code # -> enter new code # -> re-enter new code # Remark. The default code "1234" of the matching card cannot open the door unless you change the other codes.
2. Changing the user passcode with your fingerprint Press * -> Enter fingerprint -> Enter old code # -> Enter new code # -> re-enter new code # Remark. The default "1234" code of the matching fingerprint cannot open the door without changing other codes.
3. Changing the user code with the ID number Press * -> enter ID number # -> enter old code # -> enter new code # -> re-enter new code # Remark. The ID number must be known to the administrator before changing the code, the user code cannot be the default code "1234".
Other operations
1. Alarm Off Read admin card or read valid user card or enter fingerprint or type admin code #
19

Remark. When the alarm is activated, the user can turn off the alarm by reading the registered card or entering the registered fingerprint or administrator code.
2. Factory reset Users can restore the factory default settings if they forget the admin code or modify the default settings. To restore the device to factory settings, turn off the power, press and hold the # button or the exit button continuously, turn on the power, release the # button or the exit button until you hear a double beep. The admin code will be reset to the default code, which is 999999. Remark. Registered user data will not be deleted after a factory reset.
20


Microsoft Word 2019