User Guide for UE Systems models including: UltraView Ultrasonic Air and Gas Leak Detection Camera, UltraView, Ultrasonic Air and Gas Leak Detection Camera, Leak Detection Camera

PowerPoint Presentation

Marina Vilder

DOWNLOAD

UltraView Quick Visual Guide – UE Systems


File Info : application/pdf, 21 Pages, 1.97MB

PDF preview unavailable. Download the PDF instead.

00-Ultraview Visual Guide EN EU
UltraView Quick Visual Guide
· Instrument Identification · Leak Detection Mode · Power Mode (Partial Discharge Detection)*
*only available in the UltraView Plus model

Instrument Identification ULTRAVIEW Quick Visual Guide

UltraView Cloud Registration

To login go to: ultraview.uesystems.com Create a new account

After login, pair your device

To retrieve the secret code, select settings, network settings, device registration

Need more help?

· Contact UE Systems:
info@uesystems.eu +31-546725125 www.uesystems.eu
· Download the complete manual
SAFETY: WRIST STRAP WORN ALL TIMES

Items included with the UltraView

UltraView IDENTIFICATION

1. 2 Rechargeable batteries

2. Battery charger pod

1

2

3. Power adapter

4. UltraView

3

4

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Identification

UltraView IDENTIFICATION
1

2

1. Touchscreen

2. On/Off Button

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Identification
1. 124 Low Noise MEMS 2. Camera 3. Wireless Data Transfer 4. Wrist Strap 5. Battery Pack

UltraView IDENTIFICATION

3

1

2

4 5
SAFETY: WRIST STRAP WORN ALL TIMES

UltraView IDENTIFICATION

Press and Hold the Power Button for approx. 2 seconds. The button is "in" when it's on.

Wrist strap should be worn at all times for safety.

Press On/off button to power on. Press dB Display icon for main display.

Touchscreen allows for quick and easy adjustments.

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Main Screen Zoom (2x)

UltraView IDENTIFICATION

Quick Settings Screen Brightness Single or multipoint
Settings

Snapshot Browser Snapshot

Record a video max. 5 minutes

SAFETY: WRIST STRAP WORN ALL TIMES

Inspection Filters
Change Inspection Distance

Leak Detection Mode ULTRAVIEW Quick Visual Guide

UltraView Leak detection mode

Press and Hold the Power Button for approx. 2 seconds. The button is "in" when it's on

Select settings to change the inspection mode

Select Change Mode*
*you can only change mode if you have the UltraView Plus camera

Change mode : Air or Power*
*Air: Leak Detection, Power: Partial Discharge Detection

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Leak detection mode

In settings select More to change the air mode settings

Select air mode settings to change the leak parameters

Here you can change leak settings

Here you can change leak settings

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Leak detection mode

You can change the filters to block out competing ultrasounds

In the main screen, press snapshot to store a leak

If the camera is connected to WiFi, snapshots are automatically uploaded to the cloud

From the cloud you can create your leak report

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Leak Reporting Example

Leak report example

Leak report example

Leak report example

Leak report example

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Leak detection mode

UltraView Leak Detection Screen.
Leak rate and dB level

Estimated losses / year

Inspection Filters

Single or multipoint

Change Inspection Distance

WiFi Connection

Snapshot Browser
Store the leak

Record a video max. 5 minutes

SAFETY: WRIST STRAP WORN ALL TIMES

Power Mode (Partial Discharge Detection)*
ULTRAVIEW Quick Visual Guide
*only available in the UltraView Plus model

Press and Hold the Power Button for approx. 2 seconds. The button is "in" when it's on

UltraView Power Mode
Select settings to change the inspection mode

Select Change Mode*
*you can only change mode if you have the UltraView Plus camera

Change mode : Air or Power*
*Air: Leak Detection, Power: Partial Discharge Detection

SAFETY: WRIST STRAP WORN ALL TIMES

Before scanning be sure you are in the Power mode

UltraView Power Mode
Before inspecting, always wear your wrist strap

Safely scan the electrical equipment (distance)

When you see a spectrum, this means the sound from the source is electrical related.

SAFETY: WRIST STRAP WORN ALL TIMES

In the main screen, press snapshot to store a partial discharge

UltraView Power Mode
If the camera has the WiFi connected snapshots are automatically uploaded to the cloud

In the cloud you can download the audio files related to the partial discharge.

Example of Partial Discharge report

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Partial Discharge Reporting

Auto diagnosis on severity

Partial Discharge report example

Full Partial Discharge Report

From the cloud you can create the partial discharge report

SAFETY: WRIST STRAP WORN ALL TIMES

UltraView Power Mode

UltraView Partial Discharge Screen (Power Mode) Zoom 2x

PRPD Spectrum for automatic electrical emissions recognition

Inspection Filters

Change Inspection Distance

WiFi Connection

Snapshot Browser

Store snapshot

Record a video max. 5 minutes

SAFETY: WRIST STRAP WORN ALL TIMES

Need further support? Want information regarding products or training?
CONTACT:
UE Systems Europe - Windmolen 20, 7609 NN Almelo, The Netherlands T: +31 546 725 125 | E: info@uesystems.eu| W: www.uesystems.eu



References