User Guide for UE Systems models including: UltraView Ultrasonic Air and Gas Leak Detection Camera, UltraView, Ultrasonic Air and Gas Leak Detection Camera, Leak Detection Camera
UltraView Quick Visual Guide – UE Systems
File Info : application/pdf, 21 Pages, 1.97MB
DocumentDocumentUltraView Quick Visual Guide · Instrument Identification · Leak Detection Mode · Power Mode (Partial Discharge Detection)* *only available in the UltraView Plus model Instrument Identification ULTRAVIEW Quick Visual Guide UltraView Cloud Registration To login go to: ultraview.uesystems.com Create a new account After login, pair your device To retrieve the secret code, select settings, network settings, device registration Need more help? · Contact UE Systems: info@uesystems.eu +31-546725125 www.uesystems.eu · Download the complete manual SAFETY: WRIST STRAP WORN ALL TIMES Items included with the UltraView UltraView IDENTIFICATION 1. 2 Rechargeable batteries 2. Battery charger pod 1 2 3. Power adapter 4. UltraView 3 4 SAFETY: WRIST STRAP WORN ALL TIMES UltraView Identification UltraView IDENTIFICATION 1 2 1. Touchscreen 2. On/Off Button SAFETY: WRIST STRAP WORN ALL TIMES UltraView Identification 1. 124 Low Noise MEMS 2. Camera 3. Wireless Data Transfer 4. Wrist Strap 5. Battery Pack UltraView IDENTIFICATION 3 1 2 4 5 SAFETY: WRIST STRAP WORN ALL TIMES UltraView IDENTIFICATION Press and Hold the Power Button for approx. 2 seconds. The button is "in" when it's on. Wrist strap should be worn at all times for safety. Press On/off button to power on. Press dB Display icon for main display. Touchscreen allows for quick and easy adjustments. SAFETY: WRIST STRAP WORN ALL TIMES UltraView Main Screen Zoom (2x) UltraView IDENTIFICATION Quick Settings Screen Brightness Single or multipoint Settings Snapshot Browser Snapshot Record a video max. 5 minutes SAFETY: WRIST STRAP WORN ALL TIMES Inspection Filters Change Inspection Distance Leak Detection Mode ULTRAVIEW Quick Visual Guide UltraView Leak detection mode Press and Hold the Power Button for approx. 2 seconds. The button is "in" when it's on Select settings to change the inspection mode Select Change Mode* *you can only change mode if you have the UltraView Plus camera Change mode : Air or Power* *Air: Leak Detection, Power: Partial Discharge Detection SAFETY: WRIST STRAP WORN ALL TIMES UltraView Leak detection mode In settings select More to change the air mode settings Select air mode settings to change the leak parameters Here you can change leak settings Here you can change leak settings SAFETY: WRIST STRAP WORN ALL TIMES UltraView Leak detection mode You can change the filters to block out competing ultrasounds In the main screen, press snapshot to store a leak If the camera is connected to WiFi, snapshots are automatically uploaded to the cloud From the cloud you can create your leak report SAFETY: WRIST STRAP WORN ALL TIMES UltraView Leak Reporting Example Leak report example Leak report example Leak report example Leak report example SAFETY: WRIST STRAP WORN ALL TIMES UltraView Leak detection mode UltraView Leak Detection Screen. Leak rate and dB level Estimated losses / year Inspection Filters Single or multipoint Change Inspection Distance WiFi Connection Snapshot Browser Store the leak Record a video max. 5 minutes SAFETY: WRIST STRAP WORN ALL TIMES Power Mode (Partial Discharge Detection)* ULTRAVIEW Quick Visual Guide *only available in the UltraView Plus model Press and Hold the Power Button for approx. 2 seconds. The button is "in" when it's on UltraView Power Mode Select settings to change the inspection mode Select Change Mode* *you can only change mode if you have the UltraView Plus camera Change mode : Air or Power* *Air: Leak Detection, Power: Partial Discharge Detection SAFETY: WRIST STRAP WORN ALL TIMES Before scanning be sure you are in the Power mode UltraView Power Mode Before inspecting, always wear your wrist strap Safely scan the electrical equipment (distance) When you see a spectrum, this means the sound from the source is electrical related. SAFETY: WRIST STRAP WORN ALL TIMES In the main screen, press snapshot to store a partial discharge UltraView Power Mode If the camera has the WiFi connected snapshots are automatically uploaded to the cloud In the cloud you can download the audio files related to the partial discharge. Example of Partial Discharge report SAFETY: WRIST STRAP WORN ALL TIMES UltraView Partial Discharge Reporting Auto diagnosis on severity Partial Discharge report example Full Partial Discharge Report From the cloud you can create the partial discharge report SAFETY: WRIST STRAP WORN ALL TIMES UltraView Power Mode UltraView Partial Discharge Screen (Power Mode) Zoom 2x PRPD Spectrum for automatic electrical emissions recognition Inspection Filters Change Inspection Distance WiFi Connection Snapshot Browser Store snapshot Record a video max. 5 minutes SAFETY: WRIST STRAP WORN ALL TIMES Need further support? Want information regarding products or training? CONTACT: UE Systems Europe - Windmolen 20, 7609 NN Almelo, The Netherlands T: +31 546 725 125 | E: info@uesystems.eu| W: www.uesystems.eu