Instruction Manual for PHILIPS models including: BN126C LED41S-840 PSU ELB3 L1200, BN126C LED52S-840 PSU ELB3 L1500, BN126C LED80S-840 PSU ELB3 L1500, BN126C CoreLine Batten Emergency Light, BN126C, CoreLine Batten Emergency Light, Batten Emergency Light, Emergency Light, Light

BN126C G4-MI-V3.ai

BN126C G4-MI-V3.ai

Installatie-instructies

BN126C LED41S/840 PSU ELB3 L1200 | 910505103371 | Philips Lighting

PDF preview unavailable. Download the PDF instead.

BN126C G3-MI-EL 2022 09
14/14

4x

4x

1x

1x

2x

CoreLine Batten

BN126C Emergency

indoor Life L80B50 50K hrs

220V 50Hz 240V 60Hz

TYPE
BN126C LED41S/840 PSU ELB3 L1200 BN126C LED52S/840 PSU ELB3 L1500 BN126C LED80S/840 PSU ELB3 L1500

IK04 IP20

P cW

D

36

D

44

D

64

18

Max
35 Mini 0

Ta 25

System light output (Lm)
4100 5200 8000

System light output Emerygency mode (Lm)
480 500
500

1.45 1.70 1.75

Unit: mm

L

65

IP40

65

IP20

Fixed or Suspension Mounting Holes

36 4-5

36

15.2 5.2

A: Mounting distance-L1200aL1500a

15
798 605

302.5

© 08/2022 Signify Holding. All rights reserved

1/14

or
-The luminaire shall be installed by a quali ed electrican and wired in accordance with the latest IEE electrical regulations or the national requirements.
- The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced. - Luminaire must not be used or stored in corrosive environment where hazardous materials such as sulphur,chlorine, phthalates,etc,are present. - Water entering into IP20 luminaire is strictly prohibited. IP20 luminaire is not protected against wet condition, water ingress may cause electrical failure or unsafe conditions. - Luminaire is rated at IP40 from the front (part 1) and IP20 for a complete housing (part 2).

1: Luminaire opening

1

2

Part 1

Part 2

2.1:Surface Mounted

2.2:Suspend Mounted

Plug all BESA holes in the housing

3x

2x

2x

2x

2x

2.3:Mounted on a BESA
BESA 3x L1200/ L1500

2/14

3 : Wiring from end hole (side)
Optional
3.1: Wiring from back entry

H05RN-F
Min. 3 1,0mm Max. 3×2,5mm
7-12mm

4: TW/ Loop in
/ Light-line creation (Optional)

5: Light-line creation (Optional)

1x 2x nx

max. number of connected luminaire(see Inrush current table)

6: TW / Loop in / Light-line creation (Optional)

The power cord is not included in the luminaire

Last one

7
The end face of the rst luminaire and the last luminaire

3/14

8

T20
1 3
x2

2

The batteries have a life time expectancy of 4 years. Do not touch electronic components! Electronic components may be under high
9 voltage.
Light intensity distribution curves Emergency mode

A T T E N T I O N OBSERVE
PRECAUTIONS FOR HANDLING
ELECTROSTATIC SENSITIVE DEVICES
Service data for battery change:

Emergency flux: 484lm

Battery Unit

Manufacturer

Philips

Unit:

TrustSight 6,4V 4cell 3000 mAh battery LFP

Technology

LFP

Capacity

3000 mAh

Power

4,8 W

Duration

3 h

Nominal voltage

6,4 V

4/14

Maintenance instructions
To assure the lighting quality of this unique LED lighting concept there are only a few instructions regarding the maintenance of this LED luminaire:
* Do not stare into LED light beam. * The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements. * Above average concentracion of sulfur effects the useful lifetime of the product.
E.g: Light color changes from w hite to blue. Typically in chicken & pig farms.

 $IWHULQVWDOODWLRQDQGSRZHUXSWKHGULYHUZLOOGHWHFWWKHEDWWHU\DQGVWDUWWKHDXWRPDWLFGHWHFWLRQ SURFHVV -'XULQJDXWRPDWLFGHWHFWLRQWKHLQGLFDWRU/('ZLOOOLJKWXSZLWKVKRUWJUHHQIODVKHV -%HWZHHQPLQLPXPDQGPD[LPXPVHFRQGVWKH7UXVW6LJKWGULYHUZLOOVHWWKHEDWWHU\W\SH QXPHURIFHOOV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  )RUPRUHLQIRUPDWLRQSOHDVHFRQVXOWWKH7UXVW6LJKW*HQ'HVLJQLQJXLGH7KHODWHVWYHUVLRQLVDYDLODEOH RQOLQH
5/14

8
max. number of connected luminaire(see Inrush current table)

Vertical

Inrush current I mains(A)
I max
max/2
Tref

I nom. Time(us)

L1200

L1500

LED41S LED52S LED80S

11.6 10.6 10.6

499

527 527

19

19 11

13

13 13

24

24 13

38

38 22

Optional
Installation Mode 12NC Description Short EOC

Suspension 911401776802 BN126Z SC 36574999

Suspension Wire: 1m See step 2.2 for installation

2x 2x 2x
3x

Signify Holding. All rights reserved. This document contains information relating to the product portfolio of Signify which information may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract.Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or their respective owners.

Signify Holding. The Netherlands

6/14

7/14

8/14

9/14

10/14

11/14

12/14

13/14


Acrobat Distiller 11.0 (Windows)