Instruction Manual for neverdark models including: C2-700, C2-950, C2-1200, Chalet-II Automatic Bioethanol Fireplace, Chalet-II, Automatic Bioethanol Fireplace, Bioethanol Fireplace, Fireplace
Chalet-II (C2) Installation instructions neverdark.one NEVERDARK Chalet-II Installation instructions Y General view Automatic bioethanol fireplace "Chalet-II" X length oXf-f1ir5e0area 250 Z Model C2-700 C2-950 C2-1200 X Length 700 950 1200 Y Width 320 Z Height 205 Power Weight, kg consumption, W 21.1 900 26 900 29 1600 · Automatic bioethanol fireplace "Chalet-II" · Manufacturer: NEVERDARK LLC, Ukraine. · This document is a part of the device. · For decorative and domestic use only. · Keep away from children. · Ensure that the wall/table/floor on which you place the appliance can support its weight. · Install only in a place protected from draughts. · Do not cover top and side ventilation grids. · Do not place flammable objects on the appliance. · Keep a carbon dioxide fire extinguisher within sight. neverdark.one 2 NEVERDARK Chalet-II Installation instructions Standard Standard configuration Fireplace 1pc Stones 1set Ceramic firewood 1set Fiber for glow effect 1set Power cable with plug (eur) 1pc Filling hose 1pc Fuel drain hose (service only) 1pc Instructions 1pc Warranty card 1pc Micro USB cable (service only) 1pc Packaging 1set ARS 1pc Fuel hose 1pc USB cable 1pc High Voltage cable 1pc Low Voltage cable (RJ45) 1pc Options (if any) Glass border RAL Options Available options GB(1,2) Glass Border CT(R) Custom top (RAL) RC Remote Control SH Smart Home Connection Module Options X-2 8 100 neverdark.one 3 NEVERDARK Chalet-II Installation instructions Fireplace Stones Burner Fireplace interface Do not fill auto ignition with decorative stones or firewood Spark plug (auto ignition) Air intake vents Air intake vents Power cable 220V ARS communications port ARS (External module for control and refueling) Filler neck ARS fuel communication port Drainer (only for service professionals) Touch screen USB port (only for sevice professionals) Fireplace communications port neverdark.one Power button Cables Fireplace communications port USB port 4 NEVERDARK Chalet-II Installation instructions X-150 length of fire area Dimensions 320 250 201 225 min 20 X 6 clearance min 20 X-10 ±1 cutout X-22 min 220 Required air supply into the fireplace niche at least 10x10 cm 6 clearance min 21 310 ±1 cutout 298 6 clearance min 20 neverdark.one 5 NEVERDARK Chalet-II Installation instructions Installation into the worktop Safe installation of the appliance Screw in handles for mounting (unscrew after installation) min 1000 mm from burner to flammable objects (curtains or upholstered furniture, etc.) ARS communications port Outlet or connection point 3x2.5 cable 220V connection must be carried out by a qualified technician Air supply into the niche of the fireplace Horizontally align Cables ARS 500 fuel communication port It is mandatory to use a separate line with a circuit breaker with a rating of at least 10A WARNING! - Installation of the fireplace not on a horizontal level can lead to malfunction of the fireplace and possible fuel spillage. - Only a qualified specialist should connect the cable to the power network. - The fireplace mounted into in the prepared niche by holding the previously installed handles for installation, then the handles must be removed (unscrewed) and not used during the operation of the fireplace. - If it is necessary to remove the fireplace from the niche, reinstall the installation handles. neverdark.one 6 NEVERDARK Chalet-II Installation instructions Connecting Low voltage line RJ45 cable USB extension cable Power button connection 2x0.75 cable Spanner 24 required Fuel line 220V power cable Spanner 24 required USB extension cable Power button connection 2x0.75 cable Fuel line Low voltage line RJ45 cable neverdark.one 7 500 2 0 210 400 NEVERDARK Chalet-II Installation instructions 9 4 ARS Mounting holes 112 250 It is necessary to provide A passageway for communications opening 40 Fuel line length not more than 2.5m neverdark.one 8 NEVERDARK Chalet-II Installation instructions Recess installation min 400 Min 500 to curtains or easily flammable objects Heat-resistant material Mounting without the use of a thermobox Hot air output min 50 Upper part Heat-resistant material Temperature up to 130 The surface can be heated up to 80 C The canopy can be used to divert hot air from the surface Heat-resistant material op2e5n1in-+01g,5 opening +1 - 0,5 501 min 50 Outlet or connection point in the niche 3x2.5 cable min 50 Required air supply in the fireplace niche at least 10x10 cm Horizontally align For comfortable use of the fireplace it is necessary to ensure the supply of fresh air into the room and a removal of combustion products. It can be a ventilation extractor, recuperator or an opened window. WARNING! The manufacturer does not recommend placing objects above or next to the fireplace that are sensitive to high temperatures, as this can significantly shorten their service life. If the installation instructions were not followed, the manufacturer is not responsible for any damage to objects above or next to the fireplace resulting from exposure to high temperatures. There must be a fire extinguisher in the room within sight. neverdark.one 9SOLIDWORKS PDF Publisher