Instruction Manual for neverdark models including: C2-700, C2-950, C2-1200, Chalet-II Automatic Bioethanol Fireplace, Chalet-II, Automatic Bioethanol Fireplace, Bioethanol Fireplace, Fireplace

NEVERDARK Chalet-II Installation instructions - Recess inst

VVS-PC\shara (VVS-PC)

PDF preview unavailable. Download the PDF instead.

neverdark-chalet-ii-installation-instructions
Chalet-II (C2)
Installation instructions
neverdark.one

NEVERDARK Chalet-II Installation instructions
Y

General view
Automatic bioethanol fireplace "Chalet-II"
X length oXf-f1ir5e0area
250

Z

Model
C2-700 C2-950 C2-1200

X
Length
700 950 1200

Y Width
320

Z Height
205

Power Weight, kg consumption,
W

21.1

900

26

900

29

1600

· Automatic bioethanol fireplace "Chalet-II" · Manufacturer: NEVERDARK LLC, Ukraine. · This document is a part of the device. · For decorative and domestic use only. · Keep away from children. · Ensure that the wall/table/floor on which you place the appliance can support its weight. · Install only in a place protected from draughts. · Do not cover top and side ventilation grids. · Do not place flammable objects on the appliance. · Keep a carbon dioxide fire extinguisher within sight.

neverdark.one

2

NEVERDARK Chalet-II Installation instructions
Standard

Standard configuration

Fireplace

1pc

Stones

1set

Ceramic firewood

1set

Fiber for glow effect

1set

Power cable with plug (eur)

1pc

Filling hose

1pc

Fuel drain hose (service only)

1pc

Instructions

1pc

Warranty card

1pc

Micro USB cable (service only)

1pc

Packaging

1set

ARS

1pc

Fuel hose

1pc

USB cable

1pc

High Voltage cable

1pc

Low Voltage cable (RJ45)

1pc

Options (if any)

Glass border

RAL Options

Available options

GB(1,2) Glass Border CT(R) Custom top (RAL)

RC Remote Control

SH

Smart Home Connection Module

Options
X-2 8

100

neverdark.one

3

NEVERDARK Chalet-II Installation instructions
Fireplace

Stones Burner

Fireplace interface

Do not fill auto ignition with decorative stones or firewood

Spark plug (auto ignition)

Air intake vents

Air intake vents

Power cable 220V

ARS communications port

ARS (External module for control and refueling)
Filler neck

ARS fuel communication port
Drainer (only for service professionals)

Touch screen
USB port (only for sevice professionals)
Fireplace communications port
neverdark.one

Power button

Cables

Fireplace communications port

USB port 4

NEVERDARK Chalet-II Installation instructions
X-150 length of fire area

Dimensions

320 250

201 225 min 20

X

6 clearance
min 20

X-10 ±1 cutout
X-22

min 220

Required air supply into the fireplace niche at least 10x10 cm

6 clearance

min 21

310 ±1 cutout
298

6 clearance

min 20

neverdark.one

5

NEVERDARK Chalet-II Installation instructions

Installation into the worktop Safe installation of the appliance

Screw in handles for mounting (unscrew after installation)

min 1000 mm from burner to flammable objects (curtains or upholstered furniture, etc.)

ARS communications port

Outlet or connection point 3x2.5 cable

220V connection must be carried out by a qualified technician

Air supply into the niche of the fireplace

Horizontally align

Cables
ARS 500 fuel communication port

It is mandatory to use a separate line with a circuit breaker with a rating of at least 10A

WARNING! - Installation of the fireplace not on a horizontal level can lead to malfunction of the fireplace and possible fuel spillage. - Only a qualified specialist should connect the cable to the power network. - The fireplace mounted into in the prepared niche by holding the previously installed handles for installation, then the handles must be removed (unscrewed) and not used during the operation of the fireplace. - If it is necessary to remove the fireplace from the niche, reinstall the installation handles.

neverdark.one

6

NEVERDARK Chalet-II Installation instructions

Connecting
Low voltage line RJ45 cable

USB extension cable
Power button connection 2x0.75 cable

Spanner 24 required Fuel line

220V power cable Spanner 24 required

USB extension cable
Power button connection 2x0.75 cable

Fuel line
Low voltage line RJ45 cable

neverdark.one

7

500 2 0
210 400

NEVERDARK Chalet-II Installation instructions

9 4

ARS Mounting holes

112 250

It is necessary to provide A passageway for communications opening 40
Fuel line length not more than 2.5m

neverdark.one

8

NEVERDARK Chalet-II Installation instructions

Recess installation

min 400

Min 500 to curtains or easily flammable objects
Heat-resistant material

Mounting without the use of a thermobox

Hot air output min 50

Upper part Heat-resistant material Temperature up to 130  The surface can be heated up to 80 C The canopy can be used to divert hot air from the surface
Heat-resistant material
op2e5n1in-+01g,5

opening

+1 - 0,5

501

min 50
Outlet or connection point in the niche 3x2.5 cable

min 50
Required air supply in the fireplace niche at least 10x10 cm

Horizontally align

For comfortable use of the fireplace it is necessary to ensure the supply of fresh air into the room and a removal of combustion products. It can be a ventilation extractor, recuperator or an opened window.

WARNING! The manufacturer does not recommend placing objects above or next to the fireplace that are sensitive to high temperatures, as this can significantly shorten their service life. If the installation instructions were not followed, the manufacturer is not responsible for any damage to objects above or next to the fireplace resulting from exposure to high temperatures.
There must be a fire extinguisher in the room within sight.

neverdark.one

9


SOLIDWORKS PDF Publisher