User Manual for EXCELSOIR POWER models including: PS300, PS1000, PS2000, PS3000, PSX2000, PSX3000, PS5000, PS Series Power Inverters, PS Series, Power Inverters, Inverters

PS Instruction Manual - Microsoft Publisher

James MacGregor

DOWNLOAD MANUAL PDF

PS2000/24 | Inverter.com.au | value inverters – Inverter Australia

PX3000/12 | Inverter.com.au | value inverters – Inverter Australia

PSX3000/24 | Inverter.com.au | value inverters – Inverter Australia


File Info : application/pdf, 8 Pages, 994.64KB

PDF preview unavailable. Download the PDF instead.

PS Instruction Manual ?v=1743373631
PS Series Owners Manual
PS300 PS1000 PS2000 PS3000 PSX2000 PSX3000 PS5000

The Excelsior Power PS series of inverters have been carefully designed and manufactured to provide you years of reliable operation. Please read this manual thoroughly before connecting and operating your inverter. Please keep the manual for future reference, as it contains information that you may require in the correct connection, operation and troubleshooting of this inverter.
Excelsior Power Inverters
Excelsior Power have been involved in the design, manufacture and importation of power conversion technology for over 25 years. The PS series of power inverters are highly advanced, microprocessor controlled units that provide the highest surge capabilities, so they can start difficult loads, such as TV's, Microwaves, Refrigeration units and even Air Conditioners.
Unlike many inverters, which can damage 240 Vac motors, such as those found in refrigerators, the PS series provide a Pure Sine Wave output, which is very clean and perfect for Mains operated equipment, so that motors and fridges don't overheat and fail prematurely. The PSX series also have a display on front to show battery voltage and load, which takes the guess work out of battery time and consumption.
They also achieve the highest efficiency (90%) plus) which means cooler running, higher reliability and longer running time!
Excelsior Power Inverters convert 12 or 24 volt Direct Current to 240 Volt, alternating current at 50 Hz. Installation
When connecting the inverter to the battery, use the thickest wires available, keep the length as short as possible, 2 meters maximum length. To find the recommended minimal cable size for your inverter, please refer to the Specifications section at the back of this manual. To calculate the minimum battery battery size recommended for your inverter in Amp/Hours, please see the Specifications section at the back of this manual.
Mount the inverter in a clean environment, that is free of dust, insects and moisture, Ensure that the inverter has enough space around it for ventilation, especially at the front and rear for the cooling fan. Connecting your inverter 1. Make sure the switch on the front of the unit is in the off position (0)
2. Connect the wires to the inverter input terminals at the rear of the unit.
Make sure to match the negative ( Black ) terminal to the inverter with the wire that connects to the negative terminal on the battery.
3. Connect the positive ( red ) terminal on inverter connecting a wire to the
positive terminal of the battery.
4. Make sure the connections are good and secure.
WARNING: Do not reverse connect polarity to battery, as this will damage inverter, and is not covered under warranty!

Getting Started When you turn on an appliance that operates using a motor, fluo-
rescent lights, air conditioning, fridge and some electronic loads, it requires an initial surge of power to start. This surge of power can be many times the running, or continuous power rating of the appliance.
Fridges and Air conditioners can take many thousands of watts for the first second to start up.
A microwave can use up to double the rated cooking power, so an 800 Watt microwave can use up to 1600 Watts of electrical power.
To work out the current from your battery, divide the wattage of the appliance by the battery voltage; IE 100 watts / 12 volts = 8 Amps.
Although all Excelsior Inverters are electrically isolated and filtered to minimise signal interference, some interference with your TV may be unavoidable, especially with weak signals. However, here are some suggestions that may improve reception. 1. First, make sure the TV antenna produces a clear signal under
normal operating conditions ( normal grid power ) Also make sure the antenna cables properly shielded and of good quality. 2. Try changing the position of the inverter, antenna cable and TV power cord. 3. Isolate the TV, it's power cord and antenna cable from the battery power by running an extension cord from the inverter to the TV. 4. Coil the TV power cord. 5. Coil the DC battery cables from the battery to the inverter. 6. Attach a ` Ferrite Data Line Filter' to the power cord. Note: Some inexpensive audio systems may produce a slight `buzzing' sound when used from the inverter. This is caused by deficient filters in the audio system, The only solution to solve this problem is to use a sound system of a higher quality power supply.
Use of RCD's RCD's may be used with the inverter, please ensure the earth
connection of the front of the inverter is connected to the chassis of the vehicle or an earth stake.

TROUBLESHOOTING

PROBLEM: Low or no Output Voltage....................................

REASON

SOLUTION

Poor contact with the

*Clean terminals thoroughly

Battery Terminals

Use of incorrect type of Voltmeter to test inverter

*Use True RMS meter

PROBLEM: Overload LED stays on..........................................

REASON

SOLUTION

Battery voltage bellow

Recharge or replace battery

11 / 22 volts

Equipment being operated Draws too much power

*Use a higher capacity inverter or do not use This equipment.

Inverter is too hot (Thermal shutdown mode)

*Allow inverter to cool *Check for adequate
Ventilation *Reduce the load on the
Inverter to rated Continuous power

PROBLEM: Works fine but wont start fridge..........................

REASON Battery low shutdown When fridge starts

SOLUTION *Try restarting after
10 mins *Use thicker battery Cable *Check battery

TROUBLESHOOTING

PROBLEM: TV Interference....................................................

SYMPTON

SOLUTION

Electrical Interference

*Add a ferrite data line

From inverter

filter onto the TV power

Cord

*Twist input cables together

3 times every meter

*Keep the inverter as far as

Possible from TV

*Use better antenna

PROBLEM: Low Battery Alarm on All The Time..................

REASON

SOLUTION

Battery voltage bellow

*Keep input voltage above

11 / 22 volts

11 / 22 volts

Poor or weak battery condition

*Recharge or replace battery

Inadequate power being Delivered to the inverter Or excessive voltage drop

*Use thicker cable *Keep cable length as short
as possible

PROBLEM: Appliance does not start.......................................

SYMPTOM

SOLUTION

Appliance does not turn on *Try turning inverter on

Then off, then on again

*Appliance has higher start

Up surge than inverter

SPECIFICATIONS........................................................................................................

MODEL NO.

MAXIMUM SURGE NO LOAD CONTINUOUS POWER CURRENT POWER

MINIMUM INPUT DIMENSIONS MASS CABLE BATTERY VOLTS H / W / Dmm Kg SIZE AMP/HOUR

PS300/12 300 WATT

600 WATT 0.3A 30

10-15 62*105*185 1.0 6MM SQ

PS300/24 300 WATT

600 WATT 0.3A 30

20-30 62*105*185 1.0 4MM SQ

PS1000/12 1000 WATT 2000 WATT 0.8A 50

10-15 78*180*296 2.8 16MM SQ

PS1000/24 1000 WATT 2000 WATT 0.5A 30

20-30 78*180*296 2.8 8MM SQ

PS2000/12 2000 WATT 4000 WATT 0.8A 100

10-15 78*180*396 4.0 25MM SQ

PS2000/24 2000 WATT 4000 WATT 0.5A 50

20-30 78*180*396 4.0 16MM SQ

PSX2000/12 2000 WATT 4000 WATT 0.8A 100

10-15 78*180*396 4.0 25MM SQ

PSX2000/24 2000 WATT 4000 WATT 0.5A 50

20-30 78*180*396 4.0 16MM SQ

PS3000/12 3000 WATT 6000 WATT 0.8A 200

10-15 78*180*396 4.0 40MM SQ

PS3000/24 3000 WATT 6000 WATT 1.3A 100

20-30 128*180*396 5.6 20MM SQ

PSX3000/12 3000 WATT 6000 WATT 0.8A 200

10-15 128*180*396 5.6 40MM SQ

PSX3000/24 3000 WATT 6000 WATT 1.3A 200

20-30 128*180*396 5.6 20MM SQ

PS5000/12 5000 WATT 10000 WATT 1.6A 400

10-15 160*210*500 12 60MM SQ

PS5000/24 5000 WATT 10000 WATT 1.0A 200

20-30 160*210*500 12 30MM SQ

Phone:03 9775 1590 Email: Enquiries@inverter.com.au Website: www.excelsiorpower.com.au Address: Factory 1 16 Titan Drive Carrum Downs Vic, 3201



References

Microsoft: Print To PDF