Installation Guide for SALUS models including: KL08RF24, UPC Wireless Control Box, KL08RF24 UPC Wireless Control Box, Wireless Control Box
manual. 6. Press the coordinator button for five seconds until the LED shines steady red. Note: To restore the KL08RF 24V back to factory default settings at any time, using a suitable tool, press the Reset button to the right of the Pair button. Checking the System Configuration and Communication
Installation and Wiring Guide KL08RF24 www.salus-controls.com Technical Helpline 44 (0) 1226 323 961 Installing and Connecting the KL08RF24 Use the KL08RF 24V wireless wiring centre to simply and safely connect thermostats and
BATTERY POWERED PROGRAMMABLE ROOM THERMOSTAT (MODEL VS20WRF) GROUP 1 GROUP CONTROL THERMOSTAT MAINS POWERED (MODEL VS10WRF) GROUP 1 THERMOSTAT (VS20WRF) GROUP 1 THERMOSTAT (VS10WRF) GROUP 1 THERMOSTAT (VS20WRF) GROUP 2 GROUP 2 THERMOSTAT (VS10WRF) GROUP 2 CONTROL THERMOSTAT (VS20WRF) STANDALONE PROGRAMMABLE ROOM THERMOSTAT KL08RF24 Installation and Wiring Guide 24V Optional wireless receiver RX10RF SUPPLIED CABLES UNDERFLOOR HEATING MANIFOLD These actuators are supplied by 24V from the KL08RF 24V. 230V TO UFH PUMP 1.5MM CABLE (INSTALLER SUPPLIED) NL External power supply Heat / cool changeover (open = heat, closed = cool) Dew point sensor Meets the following EC Directives · Electro-Magntic Compatibility directive 2004 / 108 / EC · Low-voltage Directive 2006/95/EC These instructions apply to the SALUS model stated above. Optional boiler connection Warning This product must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the country or state where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution. For PDF Installation guide go to www.salus-controls.com www.salus-controls.com Technical Helpline +44 (0) 1226 323 961 MaintainingapolicyofcontinuedproductdevelopmentSALUSControlsplcreservestherighttochange specification, design and materials of products listed on this installation guide without prior notice. Issue Date: October 2014 Document Number 00106 Installation and Wiring Guide KL08RF24 Installing and Connecting the KL08RF24 Use the KL08RF 24V wireless wiring centre to simply and safely connect thermostats and corresponding thermal actuators. The KL08RF connects to the wireless network through the CO10RF coordinator. One coordinator can support up to nine wiring centres, which means that if you buy more than one wiring centre, you will only need one of the included coordinators. Keep the other coordinators in a safe place as spares. Install the KL08RF 24V only in dry and closed interior rooms. Relative air humidity in the room may not exceed 95%. Clean the KL08RF 24V only with a dry and soft cloth. Do not use solvents or aggressive cleaning agents. 9 Push in the Dew Point wires at the bottom right of the KL08RF 24V for voltfree humidity sensing. 1 Remove the plastic 5 Push the thermal actuator wires into the 10 Attach the red strain-relieving strip cover. Open (and round holes at the bottom of the KL08RF using the three screws to secure the close) the four white 24V. You can connect up to three pump, boiler, CO, and dew point wires screws with a quarter actuators in each zone. to the bottom side of the KL08RF 24V. turn only. Note that screws on opposite sides turn in the opposite direction. 12 Make sure there is a fuse in the fuse holder. 13 Plug in the CO10RF coordinator. LED indications Name Power G1 G2 Network Status Zone 1 actuators Zone 2 actuators Zone 3 actuators Zone 4 actuators Zone 5 actuators Zone 6 actuators Zone 7 actuators Zone 8 actuators Pump Boiler CO Co·················lour Meaning KL08RF is supplied with 230V power Wireless network activity on group 1 thermostats Wireless network activity on group 2 thermostats KL08RF is waiting to pair KL08RF is connected to the wireless network Demand from group 1, zone 1 thermostat: actuator open Demand from group 1, zone 2 thermostat: actuator open Demand from group 1, zone 3 thermostat: actuator open Demand from group 1, zone 4 thermostat: actuator open Demand from group 2, zone 1 thermostat: actuator open Demand from group 2, zone 2 thermostat: actuator open Demand from group 2, zone 3 thermostat: actuator open Demand from group 2, zone 4 thermostat: actuator open Pump on Boiler on Heating mode Cooling mode 2 Remove the white terminal connection board. 3 Attach the back of the KL08RF 24V to the wall. No need to remove the white body to mount to a DIN rail. 4 Replace the white terminal connection board 6 Push in the Pump wires at the bottom right of the KL08RF 24V for volt-free pump switching. 7 Push in the Boiler wires at the bottom right of the KL08RF 24V for volt-free boiler switching. When a zone calls for heat, the boiler switch closes causing the boiler to run. 8 Push in the CO wires at the bottom right of the KL08RF 24V for volt-free heating/cooling changeover switching. An open switch is for heating (red LED). A closed switch is for cooling (blue LED). ·· Heating mode Cooling mode 11 Set the boiler delay, wireless, and thermal actuator jumpers at the top right of the KL08RF. Jumper Settings/Positions for Pump/Boiler On/Off Delay The pump/boiler on delay and the pump off delay are fixed at three minutes. The default setting for the boiler off delay is also zero minutes, but can be changed to 15 minutes. To do this, carefully remove the jumper and re-insert it in the other position as shown below: 14 Replace the plastic cover. 15 Switch on mains power supply to the unit. The red LED comes on. Wireless The default setting for the wireless connection is internal (INT). To change this setting to external (EXT), carefully remove the jumper and re-insert it in the other position as shown below: Type of Actuator The default setting for the type of actuator is normally closed (NC). To change this setting to normally open (NO), carefully remove the jumper and re-insert it in the other position as shown below. Note that the actuator setting and thermostat setting must be the same. 16 If you need to install the optional external antenna and have set the Wireless jumpers to EXT: a. Disconnect power. b. Remove the protective cap from the antenna connection on the underside of the KL08RF 24V. c. Screw the antenna into the KL08RF 24V. d. Reconnect power. The KL08RF 24V will now use the external antenna and not the internal antenna. Connecting the KL08RF 24V (s) to the ZigBee Wireless Network 1. On powering up the KL08RF 24V, all actuator LEDs light up green then go off, then the Network Status LED flashes green. 2. Press and hold the button on the coordinator for five seconds. The button flashes red to indicate the coordinator is ready to pair. The Network Status LED on the KL08RF 24V goes steady green when connected. 3. Repeat the process for every KL08RF 24V in the system. Note that one coordinator can support up to nine KL08RFs. 4. To identify your KL08RF 24V (WC) number press Pair for one second. The LED on the zone number lights green: Zone 1 = WC -1, Zone 2 = WC-2, and so on. The Network Status LED is used to identify WC-9. 5. To pair your VS10RF or VS20RF thermostats, see your thermostat manual. 6. Press the coordinator button for five seconds until the LED shines steady red. Note: To restore the KL08RF 24V back to factory default settings at any time, using a suitable tool, press the Reset button to the right of the Pair button. Checking the System Configuration and Communication · Press and hold the coordinator button for one second. All devices connected to the system flash. To stop checking, press and hold the coordinator button again for one second. · Press and hold the Pair button on the WC for five seconds. All devices connected to the KL08RF 24V flash. To stop checking, press and hold the Pair button again for five seconds. Deleting all Devices from the Wireless Network · To delete all devices connected to the network, press and hold the coordinator button for 15 seconds. The colour of the button changes from red to amber. · To delete all devices connected to the KL08RF 24V, press and hold the Network Status button on the KL08RF 24V for 15 seconds. The G1 and G2 LEDs turn from flashing red to solid red then go off. Note: After all devices have been deleted from the wireless network, they will need to be reinstalled. Refer to the instruction manuals. www.salus-controls.com Technical Helpline +44 (0) 1226 323 961Acrobat Distiller 15.0 (Macintosh) sejda.com (4.0.20)