Ultrasonic Liquid Level Meter User Manual
This manual provides instructions for the Ultrasonic Liquid Level Meter system, including the TS-FT003 and TS-FT005 transmitters.
Product Overview
The system consists of a receiver and one or more transmitters. The TS-FT003 transmitter includes solar panels for auxiliary power, while the TS-FT005 transmitter does not.
Product Specifications
Item | Receiver | Transmitter |
Indoor Temperature Range | 0~50 °C (32~122 °F) | Temperature Resolution: 0.1 Accuracy: ±1 |
Resolution | 0.1 | |
Water Tank Temperature Measurement Range | -40~60 °C (-40~140 °F) | Water Level Resolution: 0.01m |
Alarm Duration | 120 seconds | Accuracy: ±0.05m |
Water Level Measurement Range: 1~5m | ||
Battery Usage | USB to Type-C Wire / 3*AAA | TS-FT003 Transmitter: 6*AAA 1.2V NiMH 900mAh TS-FT005 Transmitter: 6*AAA |
Communication | Wireless at 433MHz, up to 100m in open area, 30m through walls. |
Packaging Contents
- Receiver * 1
- Transmitter * 1
- Installation Screws * 2
- USB to Type-C Wire * 1
- User Manual * 1
Default Settings on Startup
- Time: 00:00~23:59 (Default: 00:00)
- Temperature Unit: °C / °F (Default: °C)
- 12HR/24HR Format: (Default: 24HR)
- Alarm Time: 00:00~23:59 (Default: 00:00, Off)
- Water Level Unit: TANK LEVEL M (meters) / TANK LEVEL FEET (feet) (Default: TANK LEVEL M)
Main Features
- Display Backlight On/Off Function: Short press any key to activate backlight for 15 seconds when on battery power. Long press '+' for 3 seconds to keep backlight constantly on or off. USB power defaults to constant backlight.
- Time Function: Displays time in 12H/24H format.
- Transmitter Low Battery Reminder: ? icon indicates low battery.
- Buzzer On/Off: ? icon indicates buzzer is on. Long press 'AL' for 3 seconds to toggle.
- Alarm Function: ⏰ icon indicates alarm is active. Maximum/minimum water level alarms can be set.
- Data Signal Indicator: ? icon shows signal status.
- Indoor Temperature Display: Shows indoor temperature with unit (default °C).
- Water Tank Temperature Display: Shows water tank temperature with unit (default °C).
- Low Water Level Icon: ?⬇️ indicates low water level.
- High Water Level Alarm Icon: ?⬆️ indicates high water level alarm.
- Water Tank Level Display: Shown in meters/feet (default meters). A 10-element LCD bar graph visually represents water level depth.
- Alarm Sound Icon: ? indicates alarm sound is on.
Power Supply Methods
Receiver: Can be powered by 3*AAA batteries or via a USB to Type-C power cable. Promptly replace batteries when the backlight dims or flickers.
TS-FT003 Transmitter: Powered by 6*AAA 1.2V NiMH rechargeable batteries. The included solar panel provides auxiliary power and charging. Use NiMH batteries for reduced replacement frequency. Ensure the solar panel faces sunlight.
TS-FT005 Transmitter: Powered by 6*AAA batteries (ships without batteries).
Note: Ensure correct battery polarity during installation to prevent damage. Battery performance affects data communication.
Installation Instructions
Transmission Distance: Up to 100m in open space, up to 30m through buildings.
Installation Steps
- Receiver Power On: After powering on, the receiver displays a full screen for 3 seconds, emits a [BEEP] sound, and shows "1.00" with a flashing empty tank icon.
- Water Tank Depth Setting: Enter the water tank depth setting mode. Use the '+' key to increase and '-' key to decrease the value (range: 0.5m to 5m / 1.64ft to 16.4ft). Long pressing the keys allows for rapid adjustment.
- Air Gap Setting: Press 'SET' again to set the air gap value (default "0.50"). This is the monitoring distance from the transmitter's bottom sensor to the highest water surface (range: 0.5m to 5m / 1.64ft to 16.4ft). A minimum of 0.5m is recommended for optimal monitoring. Use '+' and '-' keys for adjustment.
Note: If no operation occurs for 15 seconds in setting mode, it automatically switches to normal display. If the receiver displays "[ERROR]" (EEr), it indicates a data setting error. Reset by simultaneously pressing and holding 'SET' and 'AL' keys for 3 seconds.
Transmitter Installation
After setting up the receiver, power on the transmitter. The transmitter sends signals every 30 or 180 seconds.
Transmitter Installation Diagram Description: The diagram shows the transmitter mounted inside a water tank. Key components are the antenna, level bubble for horizontal alignment, installation screws, and the sensor. The tank's radius (R) and maximum measurable depth (H1) are factors. A table relates H1 (measurable depth) to H2 (distance from transmitter bottom to highest water surface), with example values: H1=0.15m requires H2=1m; H1=0.3m requires H2=2m; H1=0.5m requires H2=3m; H1=0.65m requires H2=4m; H1=0.8m requires H2=5m. H3 denotes the maximum depth the transmitter can measure. The transmitter must be installed horizontally, with the level bubble centered.
Important Installation Notes:
- The distance H2 (transmitter bottom to highest water surface) must be at least 0.5m (1.64ft).
- The maximum container depth H1 measurable by the device is 5m (16.4ft).
- Ensure the transmitter is installed horizontally using the level bubble.
Examples of Incorrect Installation:
- a. Transmitter is not installed horizontally.
- b. Transmitter is too close to the water tank walls.
- c. Solid objects are present in the water tank.
- d. The bottom of the transmitter is submerged in water or another liquid.
Note: The transmitter is designed to be splash-proof against rainwater from any direction.
Settings and Operations
Backlight Settings
When powered by batteries, a short key press activates the backlight for 15 seconds. Long press the '+' key for 3 seconds to enable/disable constant backlight. When powered by USB Type-C, the backlight is constantly on by default. Constant backlight mode under battery power consumes more battery.
Time Setting
In normal mode, long-press the 'SET' key to enter time setting. The sequence is: 24/12-hour format -> Hours -> Minutes -> Water Tank Liquid Level Unit -> Exit. Use '+' and '-' keys to adjust values; long press for rapid changes.
- 24/12-Hour Format: Select between 24-hour or 12-hour format.
- Hours/Minutes: Adjust hour and minute values.
- Water Tank Liquid Level Unit: Choose between meters (M) or feet (FEET).
Alarm Clock Setting
Press the 'AL' key once in normal mode to switch to the alarm clock display (defaults to "00:00"). Long-press 'SET' to enter alarm clock setting mode. The sequence is: Alarm Clock Hours -> Alarm Clock Minutes -> Alarm Clock On/Off -> HI AL (High Water Level Alarm) -> LO AL (Low Water Level Alarm) -> Exit.
- Alarm Clock Hours/Minutes: Adjust alarm time using '+' and '-' keys.
- Alarm Clock On/Off: Toggle the alarm clock ON or OFF. The ⏰ icon appears when ON.
- Alarm Duration: The alarm rings for 2 minutes. Press any key to stop, or it stops automatically.
- HI AL / LO AL: Set high and low water level alarms as a percentage of liquid depth. HI AL range: 60%~100%. LO AL range: 10%~40%. The corresponding alarm icon (?⬆️ or ?⬇️) will flash when the set level is reached.
- Alarm Sound: The ? icon indicates the alarm sound is on.
Turn On/Off the Buzzer
The buzzer is ON by default (? icon displayed). In normal mode, long-press the 'AL' key for 3 seconds to turn the buzzer ON or OFF. The ? icon is not displayed when OFF. This setting affects button sounds only, not alarm ringing.
Switching Between Water Tank Level and Temperature Display
In normal mode, press the 'TANK' key to switch the display between water tank level and water tank temperature.
Temperature Range Notes:
- Receiver: 0~50 °C (32~122 °F).
- Transmitter: -40~60 °C (-40~140 °F).
- Display shows "LL.L" for temperatures below the minimum and "HH.H" for temperatures above the maximum. High or low temperatures may affect battery performance.
Temperature Unit Switch
In normal mode, press the '-' key to switch between Celsius (°C) and Fahrenheit (°F) temperature units.
How to Reconnect the Signal
If the transmission signal is lost, the ? icon disappears. The displayed water level and temperature will hold their last measured values. If reconnection doesn't occur within 1 hour, the water level value will start flashing. To manually reconnect when near the transmitter, press and hold the 'TANK' key for 3 seconds in normal mode.
Note: The maximum interval between transmitter signal transmissions is 3 minutes. If connection attempts fail, check transmitter functionality, replace the battery, and restart the transmitter. For the fastest connection, power on and set up the receiver first, then power on the transmitter.