DDSU666-H Smart Power Sensor Quick Guide

Issue: 01

Date: 2018-05-18

1 Overview

Model Naming Conventions

DDSU666-H

Dimensions:

Port Definition:

Terminal Connections:

Diagrams:

The device is a rectangular unit with terminals on the top and bottom. The front panel displays the model name, CE marking, and input/output specifications. It features a mounting ear on the side.

The terminal block shows connections for AC power (L, N), CT current (I*, I), and RS485 communication (RS485A, RS485B).

2 Installing the DDSU666-H

  1. Install the instrument on the standard DIN rail of DIN35mm.
  2. Install the instrument to the standard DIN rail from the top to the bottom, and then push the instrument to the DIN rail from the bottom to the front part.

3 Installing the DDSU666-H Cable

Prepare cables

Cable DDSU666-H Type Conductor Cross-sectional Area Range Outer Diameter Source
AC power cable L-3, N-4 Two-core (L and N) outdoor copper cable 4-6 mm² 10-21 mm Prepared by the customer
CT cable I*-5, I-6 N/A N/A N/A Manufacturer
Comm. cable RS485A-24, RS485B-25 Two-core outdoor shielded twisted pair 0.25-1 mm² 4-11 mm Manufacturer

Connecting Diagram

  1. Connect the L,N voltage lines to the 3, 4 terminals of the collector.
  2. Connect current transformer outlets I*, I to terminals 5, 6 of the collector.
  3. Connect RS485A and RS485B to the communication host.

Diagram Description:

The diagram shows the LOAD connected to the CT. The CT is then connected to terminals 5 and 6 of the DDSU666-H. The voltage lines (L, N) are connected to terminals 3 and 4. RS485A and RS485B are connected to the communication host.

4 User Interface

Display (Auto loop)

Auto loop Switch time = 5s.

No. Display interface Description No. Display interface Description
1 Imp. kWh 0001.20 Imp. active energy=1.2kWh 2 Exp. kWh 0001.00 Exp. active energy=1.0kWh
3 kW P 1.100 active power=1.1kW 4 V U 220.0 Voltage =220.0V
5 A I 5.000 Current =5.000A 6 F 50.00 Hz Freq.=50.00 Hz

Display (Change By Key ◀ ▶)

No. Display interface Description No. Display interface Description
1 kWh 0000.20 Comb. active energy=0.20kWh 2 Imp. kWh 0001.20 Imp. active energy=1.2kWh
3 Exp. kWh 000 1.00 Exp. active energy=1.00kWh 4 71.9600 None parity, 1 stop bit, baud=9600bps
5 NO. 011 Comm.Add = 11 6 V U 220.0 Voltage=220.0V
7 A I 5.000 Current =5.000A 8 kW P 1.100 active power=1.1kW
9 FE 1.000 Power Factor =1.000 10 F 50.00 Hz Freq.=50.00 Hz

Comb. active energy = Imp. active energy - Exp. active energy

Setup

The Power Sensor can set up the communication address and the baud rate through the key. Long press the button 3s, the Power Sensor automatically enters into the setting interface of communication address, while the setting & display interface of baud rate and communication address circularly displays. Please press the button once for required settings for baud rate or communication address, and it will exit the communication address and baud rate without button operation for twenty seconds.

Comm.Add Interface:

Power on -> Long press 3s -> Press once -> Alternate appearance (011) -> Press once -> Alternate appearance (012) -> exit after 20s

Baud Interface:

Alternate appearance (71.9600) -> Alternate appearance (71.4800)

5 Troubleshooting

Fault phenomenon Factor analysis Elimination method
No display after the instrument being powered on 1. Incorrect wiring mode;
2. Abnormal voltage supplied for the instrument;
1. If the wiring mode is incorrect, please connect based on the correct wiring mode (see the wiring diagram).
2. If the supplied voltage is abnormal, please supply the voltage on the instrument specification.
Abnormal RS485 communication 1. The RS485 communication cable is disconnected, short circuit or reversely connected.
2. The address, baud rate, data bit and parity bit of the instrument is not in accordance with the host computer;
1. If any problems for the communication cable, please change the cable.
2. Set the address, baud rate, data bit and parity bit of the instrument to be the same as the host computer through buttons and so as the "parameter setting".
Power metering inaccuracy 1. Wrong wiring, please check whether the corresponding phase sequence of voltage and current is correct.
2. Check whether the high & low end of current transformer inlet is reversely connected. Please observe the power, to be abnormal if any negative values.
For wrong wiring, please connect based on the correct wiring mode (see Connecting Diagram).

6 Verifying the Installation

  1. Check that all mounting brackets are securely installed and all screws are tightened.
  2. Check that all cables are reliably connected with correct polarity and no short circuit.

7 Powering On the System

For details, see the other description.

Models: DDSU666-H Smart Power Sensor, DDSU666-H, Smart Power Sensor, Power Sensor, Sensor

File Info : application/pdf, 7 Pages, 1.04MB

PDF preview unavailable. Download the PDF instead.

HUAWEI DDSU666-H (01)

References

Related Documents

Preview DDSU666-H Smart Power Sensor Quick Guide
A quick guide for the Huawei DDSU666-H Smart Power Sensor, covering installation, cable preparation, connecting diagram, user interface, and troubleshooting.
Preview DDSU666-H Smart Power Sensor User Manual
User manual for the Huawei DDSU666-H Smart Power Sensor, detailing its functions, electrical properties, structure, safety precautions, and technical specifications.
Preview Huawei DDSU666-H Smart Power Sensor User Manual
This user manual provides comprehensive information on the Huawei DDSU666-H Smart Power Sensor, covering its purpose, intended audience, safety precautions, overview, technical specifications, and troubleshooting.
Preview Huawei DTSU666-H and DTSU666-H 250 A/50mA Smart Power Sensor Quick Guide
A quick guide for the Huawei DTSU666-H and DTSU666-H 250 A/50mA Smart Power Sensors, covering models, appearance, specifications, installation, wiring diagrams, user interface, troubleshooting, and customer service contact information.
Preview Huawei DTSU666-HW Smart Power Sensor Quick Guide
This document provides a quick guide for installing and operating the Huawei DTSU666-HW Smart Power Sensor, covering dimensions, appearance, key specifications, port definitions, installation procedures, wiring scenarios, and troubleshooting.
Preview DTSU666-HW Smart Power Sensor Quick Guide
A quick guide to the DTSU666-HW Smart Power Sensor, covering its dimensions, appearance, key specifications, port definitions, installation, wiring scenarios, display, parameter settings, and troubleshooting.
Preview Huawei DTSU666-H Smart Power Sensor User Manual
User manual for the Huawei DTSU666-H 100 A and 250 A Smart Power Sensor, covering its purpose, intended audience, safety precautions, overview, technical specifications, system maintenance, and current transformer details.
Preview Huawei SUN2000 Inverter and Networking Devices Installation and Troubleshooting Guide
Comprehensive guide to installing and troubleshooting Huawei SUN2000 series solar inverters, Smart Dongles, SmartLoggers, and DTSU666-H smart power sensors. Includes video links, document references, and technical specifications.