Hotpoint Ductless Single Zone Split Systems

Specification Guide

Product Models

Cooling Only:

Heat Pump:

1. SPECIFICATIONS

Compressor Type: DC Inverter Driven Rotary

Voltage/Cycle/Phase: 208-230/60/1

Built-in WiFi: Yes

Cooling-Only Models

12K 18K 24K
Outdoor Unit Model 1H12HN2CAA 1H18HN2CAA 1H24HN2CAA
Outdoor Unit UPC 084691949534 084691949558 084691949572
Indoor Unit Model HW12HN2CAA HW18HN2CAA HW24HN2CAA
Indoor Unit UPC 084691949541 084691949565 084691949589
Rated Capacity Btu/hr 12,000 18,000 24,000
Capacity Range Btu/hr 3,300-13,800 4,100-20,000 4,700-25,200
Cooling SEER2 20.0 19.0 18.0
EER2 12.0 10.6 10.6
Moisture Removal Pt./hr 1.2 2.2 2.4
Operating Ranges Cooling °F (°C) 14-115 °F (-10~46 °C)
Maximum Fuse Size A 15 20 25
Minimum Circuit Amp A 12 14 18
Outdoor Noise Level dB 55 59 60
Outdoor Unit Dimensions (in/mm)
Height 21 3/4 (553) 25 1/4 (642) 25 1/4 (642)
Width 31 1/2 (800) 32 1/4 (820) 32 1/4 (820)
Depth 11 (280) 12 (306) 12 (306)
Indoor Unit Dimensions (in/mm)
Height 11 (292) 11 (292) 13 5/8 (345)
Width 31 3/4 (805) 31 3/4 (805) 43 1/2 (1105)
Depth 7 7/8 (200) 7 7/8 (200) 9 1/2 (240)
Connections
Liquid O.D. in 1/4 1/4 1/4
Refrigerant Suction O.D. in 3/8 1/2 1/2
R32 Factory Charge Oz 25.75 38.8 45.86
Maximum Line Length Ft/m 66/20 83/25 83/25
Maximum Height Ft/m 33/10 50/15 50/15

Heat Pump Models

09K 12K 18K 24K
Outdoor Unit Model 1H09HN2DAA 1H12HN2DAA 1H18HN2DAA 1H24HN2DAA
Outdoor Unit UPC 084691944430 084691949473 084691949497 084691949510
Indoor Unit Model HW09HN2DAA HW12HN2DAA HW18HN2DAA HW24HN2DAA
Indoor Unit UPC 084691949466 084691949480 084691949503 084691949527
Rated Capacity Btu/hr 9,000 12,000 18,000 24,000
Capacity Range Btu/hr 3,100-11,000 3,300-13,800 4,100-20,000 4,700-25,200
Cooling SEER2 18.0 18.0 18.0 18.0
EER2 12.0 12.0 12.0 10.6
Moisture Removal Pt./hr 1.0 1.2 2.2 2.4
Heating Capacity Range Btu/hr 2,100-11,000 2,800-13,300 3,800-20,000 4,300-25,600
Rated Heating Capacity 47°F Btu/hr 10,000 13,000 19,000 25,000
COP @ 47°F 3.7 3.5 3.1 3.0
Max. Heating Capacity 5°F Btu/hr 7,000 9,100 13,300 17,500
COP @ 5°F 1.8 1.8 1.8 1.8
HSPF2 (IV)/HSPF2 (V) 9.5/7.1 9.5/7.2 9.5/7.2 9.5/7.1
Operating Ranges Cooling °F (°C) 14~115 °F (-10~46 °C)
Operating Ranges Heating °F (°C) -15~75 °F (-26~24 °C)
Maximum Fuse Size A 15 15 20 25
Minimum Circuit Amp A 12 12 14 18
Outdoor Noise Level dB 55 55 59 60
Outdoor Unit Dimensions (in/mm)
Height 21 3/4 (553) 21 3/4 (553) 25 1/4 (642) 25 1/4 (642)
Width 31 1/2 (800) 31 1/2 (800) 32 1/4 (820) 32 1/4 (820)
Depth 11 (280) 11 (280) 12 (306) 12 (306)
Indoor Unit Dimensions (in/mm)
Height 11 (292) 11 (292) 12 1/8 (307) 13 5/8 (345)
Width 31 3/4 (805) 31 3/4 (805) 34 1/2 (875) 43 1/2 (1105)
Depth 7 7/8 (200) 7 7/8 (200) 8 1/2 (217) 9 1/2 (240)
Connections
Liquid O.D. in 1/4 1/4 1/4 1/4
Refrigerant Suction O.D. in 3/8 3/8 1/2 1/2
R32 Factory Charge Oz 25.75 25.75 38.8 45.86
Maximum Line Length Ft/m 66/20 66/20 83/25 83/25
Maximum Height Ft/m 33/10 33/10 50/15 50/15

Note: Cooling performance rating shall be verified following AHRI 210/240 standards of 80°F (27°C) DB / 67°F (19°C) WB indoor temperature and 95°F (35°C) DB/75°F (24°C) WB outdoor temperature. Heating performance rating shall be verified following AHRI 210/240 standards of 70°F (21°C) DB / 60°F (16°C) WB indoor temperature and 47°F (8°C) DB/43°F (6°C) WB outdoor temperature.

Capacity Correction: Please refer to the submittal documents for specific Capacity Correction tables available at www.GEAppliancesAirAndWater.com

2. SYSTEM

2.1 General

2.1.1 Description: The heat pump and cooling-only air conditioner are variable capacity, mini-split type systems, each comprised of a single outdoor and a single wall-mounted indoor unit.

2.1.2 Toxicity: The heat pump system complies with RoHS standards.

2.2 Installation Requirements

2.2.1 Lineset:

2.3 Electrical Requirements:

2.3.1 Electrical Supply: Models operate on 208/230 volts AC, single-phase, 60 hertz. Voltage must be between 187~253 volts. Installation must comply with local building and electrical codes.

2.3.2 Connecting Wire to Indoor: Use 4 conductor - 14 AWG stranded copper wire. Wire must be continuous unless local code requires a disconnect at the indoor unit.

3. OUTDOOR UNITS

3.1 Dimensions

1H09HN2, 1H12HN2:

[Diagram showing dimensions for 1H09HN2 and 1H12HN2 outdoor units]

1H18HN2, 1H24HN2:

[Diagram showing dimensions for 1H18HN2 and 1H24HN2 outdoor units]

3.2 General

3.2.1 Outdoor Unit Description: Comprised of a condenser coil with all necessary components and controls for rated operation.

3.2.2 Sound Pressure Rating: Measured according to JIS C 961 standard.

MODEL SOUND PRESSURE RATING DB (A)
1H12HN2CAA 55
1H18HN2CAA 59
1H24HN2CAA 60
1H09HN2DAA 55
1H12HN2DAA 55
1H18HN2DAA 59
1H24HN2DAA 60

3.2.3 Warranty: Covered by manufacturer's parts warranty.

3.3 Installation

3.3.1 Condensate: Installer must adhere to local building codes for condensate water management.

3.3.2 Clearances: Installer must follow recommended clearances from the Installation Manual.

3.4 Components

3.4.1 Coil: Blue hydrophilic coating on aluminum fins, internally grooved copper tubing for 25% increased heat exchange surface area. Factory charged with R-410A refrigerant for 25 feet of lineset.

3.4.2 Fan Motor: Brushless, variable speed DCV motor type, molded with heat-hardened resin, permanently lubricated SRC bearings.

3.4.3 Fan Blade: UL flame rated plastic-resin design, factory balanced for quiet performance and enhanced velocity.

3.4.4 Compressor: DC rotary type, A-PAM inverter-driven for stable operation. Variable speed, variable capacity with internal overload protection. Uses PVE (FV50S) refrigerant oil.

3.4.5 4WV: Four-way reversing valve to change system mode from cool to heat.

3.4.6 EEV: Electronic expansion valve regulates refrigerant flow. Outdoor control monitors flow using a pulse-operated coil to maintain 10°F (5.5°C) of superheat.

3.4.7 Base Pan: Commercial grade DC51/DC52 hot-dip galvanized steel with coating. Ships with a 1/2 inch drain port adapter.

3.4.8 Copper Piping: Internally connected copper tubing conforms to ASTM B280 tolerances.

3.4.9 Outdoor Enclosure Materials: Commercial grade DC51/DC52 hot-dip galvanized steel with coating.

3.4.10 Defrost: Heat pump units feature a reverse-cycle (hot gas) defrost system.

3.4.11 Accumulator: Connected to the compressor return line to prevent liquid refrigerant from entering the compressor.

4. INDOOR UNITS

4.1 Dimensions

HW09HN2, HW12HN2:

[Diagram showing dimensions for HW09HN2 and HW12HN2 indoor units]

HW18HN2:

[Diagram showing dimensions for HW18HN2 indoor units]

HW24HN2:

[Diagram showing dimensions for HW24HN2 indoor units]

4.2 General

4.2.1 Indoor Unit Description: Wall-mounted indoor section connects to the outdoor unit with field-supplied piping and wiring.

4.2.2 Sound Pressure Ratings: Measured according to JIS C 9612 standard.

Model Indoor Sound Level dB (Turbo/High/Med/Low/Quiet)
HW12HN2CAA 46/44/39/33/29
HW18HN2CAA 49/46/43/40/31
HW24HN2CAA 52/49/46/43/38
HW09HN2DAA 45/43/38/32/28
HW12HN2DAA 46/44/39/33/29
HW18HN2DAA 49/46/43/40/31
HW24HN2DAA 52/49/46/43/38

4.2.3 Warranty: Covered by manufacturer's parts warranty.

4.3 Installation

4.3.1 Condensate: Shipped with insulated polyethylene condensate tubing (5/8" ID) and a 6.5 ft (2m) corrugated drain tube. Gravity drain.

4.3.2 Clearances: Follow minimum clearances illustrated in the Installation Manual.

4.3.3 Mounting: Ships with a galvanized metal wall bracket with multiple anchor points. Field-supplied mounting hardware must be sufficient.

4.4 Electrical Requirements

4.4.1 Electrical Disconnect: Connecting wire must be continuous unless local code requires a disconnect at the indoor unit. If required, it must be a 3-pole, single-throw type.

MODEL FAN MOTOR RATING (HP)
HW12HN2CAA 0.03
HW18HN2CAA 0.03
HW24HN2CAA 0.07
HW09HN2DAA 0.03
HW12HN2DAA 0.03
HW18HN2DAA 0.03
HW24HN2DAA 0.07

4.5 Temperature And Air Flow Distribution

HWO9HN2:

[Diagram: Cooling Air Velocity Distribution for HWO9HN2]

[Diagram: Cooling Temperature Distribution for HWO9HN2]

[Diagram: Heating Air Velocity Distribution for HWO9HN2]

[Diagram: Heating Temperature Distribution for HWO9HN2]

HW12HN2:

[Diagram: Cooling Air Velocity Distribution for HW12HN2]

[Diagram: Cooling Temperature Distribution for HW12HN2]

[Diagram: Heating Air Velocity Distribution for HW12HN2]

[Diagram: Heating Temperature Distribution for HW12HN2]

HW18HN2:

[Diagram: Cooling Air Velocity Distribution for HW18HN2]

[Diagram: Cooling Temperature Distribution for HW18HN2]

[Diagram: Heating Air Velocity Distribution for HW18HN2]

[Diagram: Heating Temperature Distribution for HW18HN2]

HW24HN2:

[Diagram: Cooling Air Velocity Distribution for HW24HN2]

[Diagram: Cooling Temperature Distribution for HW24HN2]

[Diagram: Heating Air Velocity Distribution for HW24HN2]

[Diagram: Heating Temperature Distribution for HW24HN2]

4.6 Components

4.5.1 Coil: Indoor coil with blue hydrophilic coating on aluminum fins and internally grooved copper tubing for increased heat exchange. Pressure tested at 600~650 PSI. Charged with dry nitrogen at 70~100 PSI for shipping.

4.5.2 Fan Motor: Sealed DC multiple-speed resin-packed motor with permanently lubricated bearings.

4.5.3 Fan Blade: Corrosion-resistant cross-flow blower, designed for quiet and even airflow.

4.5.4 Copper Piping: Connected to insulated annealed copper with male flare connections.

4.5.5 Air Louvers: Horizontal non-motorized and vertical motorized louvers for wide angle airflow distribution (horizontal 120°, vertical 90°).

4.5.6 Display: 4.5 x 1.1-inch backlit display for temperature and mode icons. Can be turned off via remote.

4.5.7 WiFi: Built-in WiFi capabilities.

4.5.8 Filter: Removable, washable, and reusable air filters.

4.5.9 Control: Ships with a standard hand-held remote control. Compatible with simple and programmable wired controllers.

4.5.10 Installation Clip: Built-in clip for easier access during installation and repair.

4.7 Mounting Bracket Dimensions

HW09HN2, HW12HN2:

[Diagram showing mounting bracket dimensions for HW09HN2 and HW12HN2]

HW18HN2:

[Diagram showing mounting bracket dimensions for HW18HN2]

HW24HN2:

[Diagram showing mounting bracket dimensions for HW24HN2]

5. CONTROLS AND ACCESSORIES

5.1 Standard Remote Control

5.1.1 General: Compatible with wall-mounted indoor units. Packaged with indoor units.

5.1.2 Connection: Infrared connection.

5.1.3 Warranty: 1-year warranty on defects in workmanship or material.

5.1.4 Features: Power button, mode buttons (Heat, Cool, Dry), temperature +/- adjustment, fan speed, vertical and horizontal louver adjustments. Precise temperature setting (±1°F / ±0.5°C). Child lock function. Ability to turn indoor unit display on/off. Displays Fahrenheit or Celsius.

5.2 WiFi

5.2.1 General: Units come complete with built-in WiFi.

5.2.2 Connection: WiFi app compatible with iOS and Android. Paired with existing 2.4gHz network. Complies with FCC Part 15 rules.

5.2.3 Warranty: 1-year warranty on defects in workmanship or material.

5.2.3.4 Features: Google Home and Amazon Alexa compatible. Homeowner can configure WiFi.

Models: 1H12HN2DAA, 1H12HN2DAA Ductless Mini Split Outdoor Heat Pump System, Ductless Mini Split Outdoor Heat Pump System, Mini Split Outdoor Heat Pump System, Split Outdoor Heat Pump System, Outdoor Heat Pump System, Heat Pump System, System

File Info : application/pdf, 18 Pages, 2.07MB

PDF preview unavailable. Download the PDF instead.

frsyqgmuqkwb

References

Adobe InDesign 19.3 (Windows) (C) 2018 Retailer Web Services LLC, all rights reserved.

Related Documents

Preview Hotpoint Single Zone Ductless Split Systems Service Manual
This service manual provides detailed information on the installation, operation, and maintenance of Hotpoint Single Zone Ductless Split Systems. It covers cooling-only and heat pump models, including specifications, functions, controls, and troubleshooting.
Preview Hotpoint Single Zone Ductless Split Systems Service Manual
This service manual provides detailed information on the Hotpoint Single Zone Ductless Split Systems, including specifications, operation, functions, controls, and troubleshooting for both cooling-only and heat pump models.
Preview Hotpoint Duct-Free System Owner's Manual
This manual provides safety information, remote control features and settings for cooling and heat pump modes, manual operation and maintenance, Wi-Fi pairing, troubleshooting tips, and limited warranty information for the Hotpoint Duct-Free System.
Preview Hotpoint Ductless Single Zone Highwall Indoor Unit Installation Instructions
Comprehensive installation instructions for the Hotpoint Ductless Single Zone Highwall Indoor Unit, covering safety precautions, required tools, and step-by-step guidance for proper setup and operation.
Preview Hotpoint Single Zone Ductless Split Systems Service Manual
This service manual provides comprehensive technical information for Hotpoint Single Zone Ductless Split Systems, covering both cooling-only and heat pump models. It details system overview, specifications, functions, controls, safety precautions, and troubleshooting.
Preview Hotpoint HTW265ASWWW 4.0 cu. ft. Washer: Features and Specifications
Detailed specifications and features for the Hotpoint HTW265ASWWW, a 4.0 cu. ft. capacity top-load washer with stainless steel basket, Cold Plus, and Water Level Control.
Preview Hotpoint 208-230V 24,000 BTU Ductless Mini-Split Outdoor Heat Pump
Information on the Hotpoint 208-230V 24,000 BTU Ductless Mini-Split Outdoor Heat Pump, including features, specifications, and warranty.
Preview Hotpoint RBS160*M*** Residential Electric Cooking Product Specifications
Detailed specifications for the Hotpoint RBS160*M*** ENERGY STAR Certified Residential Electric Cooking Product, including dimensions, power, energy consumption, and cooking zone details.