User Manual for AVTECHSMART models including: PANEL150TW, PANEL150TW Studio LED Panel, Studio LED Panel, LED Panel, Panel
PANEL150TW - Sistemamt
Studio Panel Power connection Power Requirements The PANEL150TW luminaire operates on 100 to 240 volts AC ( /- 10%, auto-ranging). The luminaire
AVTech
File Info : application/pdf, 12 Pages, 1.04MB
DocumentDocumentPA NEL150 TW Studio LED Panel V1.1 SW2.4 Table of contents Caution! 3 Introduction 3 Safety instructions 3 Installation 4 Read `Safety information' before installing the fixture.................................................................................4 Fastening the fixture to a flat surface...........................................................................................................4 Mounting the fixture on a truss .....................................................................................................................4 Securing with a safety cable .........................................................................................................................5 DMX-512 connection/connection between fixtures ....................................................................................5 Power connection ..........................................................................................................................................6 Operation 6 Control Menu Map .........................................................................................................................................6 Control menu..................................................................................................................................................7 Main Menu......................................................................................................................................................8 Addressing......................................................................................................................................................8 Universal DMX Control...................................................................................................................................9 RDM control....................................................................................................................................................9 Rotary Knob function .....................................................................................................................................9 Set dimmer curves .......................................................................................................................................10 DMX Protocol 11 Fixture Cleaning 11 Troubleshooting 12 The fixture does not work, no light..............................................................................................................12 Technical specifications 12 Studio Panel Caution! Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires! Avoid looking directly into the light source! Wear protective glasses and other PPE (personal protective equipment) when working on or near the fixture. Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product's specification label.Make sure it is grounded when using it! Unplug mains lead before opening the housing! Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the powercord from time to time. Make sure to replace the fuse with another of the same type and rating. For your own safety, please read this user manual carefully before you initial start-up. Follow operating safety precautions and pay attention to warning signs methods and equipment on the user manual. Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot during operation. After use, wait for a cool-down period of at least 10 minutes before handling or transporting the device. Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 20 rating. The ambient temperature must always be between -5° C and +45° C. Every person involved with the installation, operation and maintenance of this device has to - be qualified - follow the instructions of this manual - consider this manual to be part of the total product - keep this manual for the entire service life of the product - pass this manual on to every further owner or user of the product - download the latest version of the user manual from the Internet Introduction Thank you for having chosen PANEL150TW. You will see you acquired a powerful and versatile device. Unpack your item. Before you initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device. Safety instructions This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Always disconnect from the mains, when the device is not in avtechsmart.com 3 V1.1 SW2.4 Studio Panel use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by authorized dealers. Installation Read `Safety information' before installing the fixture. The fixture is designed for indoor use only and must be used in a dry location with adequate ventilation. Ensure that none of the fixture's ventilation slots are blocked. Fasten the fixture to a secure structure or surface. Do not stand it on a surface or leave it where it can be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed in this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails. Fastening the fixture to a flat surface The fixture can be fastened to a hard, fixed, flat surface that is oriented at any angle. Ensure that the surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be installed on it. Fasten the fixture securely. Do not stand it on a surface or leave it where it can be moved or fall over. If you install the fixture in a location where it may cause injury or damage if it falls, secure it as directed below with a securely anchored safety cable that will hold the fixture if the primary fastening method fails. Mounting the fixture on a truss The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in any other orientation, you must use a half-coupler clamp that completely encircles the truss chord. To clamp the fixture to a truss: 1. Check that the rigging structure can support at least 10 times the weight of all fixtures and equip- ment to be installed on it. 2. Block access under the work area. 3. Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting bracket legs and be fastened with a self-locking nut. 4. Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp securely. 5. Secure the fixture with a safety cable as directed below. avtechsmart.com 4 V1.1 SW2.4 Studio Panel Securing with a safety cable Secure the fixture with a safety cable (or other secondary attachment) that is approved for the weight of the fixture so that the safety cable will hold the fixture if a primary attachment fails. Loop the safety cable through the eyebolt in the back of the fixture and around a secure anchoring point. Do not loop the safety cable around the fixture's mounting bracket only, as this will leave the fixture unsecured if it separates from the bracket. DMX-512 connection/connection between fixtures Occupation of the XLR-connection: DMX OUT DMX IN 1. Group 2. Signal (-) 3. Signal (+) 1. Group 2. Signal (-) 3. Signal (+) If you are using controllers with this occupation, you can connect the DMX-output of the controller directly with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter-cables. Building a serial DMX-chain: Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always connect one output with the input of the next fixture until all fixtures are connected. DMX-512 connection with DMX terminator: For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR socket of the last fixture in the chain. Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 resistor between Signal () and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture. avtechsmart.com 5 V1.1 SW2.4 Studio Panel Power connection Power Requirements The PANEL150TW luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an auto-ranging power supply. Power linking between fixtures: The fixture with powercon in and out socket. Connect the power out to the power in socket in the next fixture till all are connected. Caution: maximum power linking - 6 units. Connection with the mains: Connect the device to the mains with the enclosed power supply cable. The occupation of the connection cables as below: Cable color Brown Blue Yellow/green Connection Live Neutral Earth(Ground) International L N Operation The PANEL150TW can operate in three different modes. This next section will detail the differences in the operating modes. Control Menu Map Default setting in bold. MAIN MENU LEVEL 1 DMX 001-512 DMX Mode Auto Maunal Curve Dimmer Mode LEVEL 2 LEVEL 3 2/5CH Program 001-004 Speed 001-009 Dimmer 000-255 CTO 3200K - 5600K 0.3-3.0 Standard Stage TV Architecture Theatre Studio Turbo FUNCTION INSTRUCTION DMX address setting DMX channel mode Preset programs Programs speed Dimmer 0-100% Color temperature 3200K - 5600K Dimmer curves adjustment Dimmer mode, Standard Dimmer mode, Stage Dimmer mode, TV Dimmer mode, Architecture Dimmer mode, Theatre Less power, lower fan speed Trubo mode, 300W output max. avtechsmart.com 6 V1.1 SW2.4 Studio Panel Advance Reset Reverse Custom Authorization On/Off Signal Priority DMX Signal Hold On/Off RDM On/Off Screen Timeout 30S Never Screen Brightness 25-100% 1.20KHz 1.60KHz Dimming Freq 2.40KHz 4.00KHz 6.00KHz 2000KHz Software version Yes/No Yes/No Fade in (150 Fade ms~2230 out ms) Custom dimmer curve (150 ms~2230 ms) Advanced settings/calibration(Only qualified technicians should perform this function. Inqure your local dealer for password.) DMX signal priority setting Run if signal cut RDM function on/off Display shut off time Display brightness Dimmer frequency setting xxx Software version System reset Display reverse 180 degree Control menu The information menu will appear after the fixture is switched on. In this menu, the following status is displayed: avtechsmart.com 7 V1.1 SW2.4 Studio Panel Main Menu Press the MENU button to enter the Main Menu interface. Menu DMX Mode Dimmer Advance Addressing All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture responds to the correct control signals. This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller. The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device. You can set the same starting address for all fixtures or a group of fixtures, or make different address for each fixture individually. If you set the same address, all the units will start to listen to the same control signal from the same channel number. In other words, changing the settings of one channel will affect all the fixtures simultaneously. If you set a different address, each unit will start to listen to the channel number you have set, based on the quantity of control channels of the unit. That means changing the settings of one channel will affect only the selected fixture. In the case of the PANEL150TW, which is 2/5 channels fixture. If you set, for example, the address in the 2 channel mode to channel 3, the device will use the channel 3-4 for control. avtechsmart.com 8 V1.1 SW2.4 Studio Panel Note: After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is data received at the DMX input, you will see the DMX indicator light in green. Universal DMX Control This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX controller allows you to create unique programs tailored to your individual needs. RDM control The PANEL150TW can communicate using RDM (Remote Device Management) in accordance with ESTA's American National Standard E1.20-2006: Entertainment Technology RDM Remote Device Management Over DMX512 Networks. RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open standard for DMX512 device configuration and status monitoring. The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and receive messages from specific fixtures. With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful when the device is installed in a remote area. Each PANEL150TW has a factory set RDM UID (unique identification number). Note: Before operation, enable RDM function in Advanced settings. DMX Mode Dimmer Advance Rotary Knob function The knob in the rear panel of the PANEL150TW act as multi function. Including rotary control of dimmer, rotary control of dimmer, up/down/enter function function. Dimmer function: 1. Press the MENU button to enter the main menu. 2. Press the UP or DOWN button to select Mode menu and press ENTER. 3. Press DOWN menu and select Manual sub menu. avtechsmart.com 9 i V1.1 SW2.4 Studio Panel 4. Press ENTER and select Brightness or Strobe in third menu. 5. Rotate the rotary knob to control the dimmer(right stop = maximum output, left stop = zero output), or strobe(right stop = maximum strobe, left stop = no strobe). Note: Rotary dimmer or strobe function works in information Menu and Mode-Manual menu. Up, Down, Enter function: The knob can also act as up, down and enter function. 1. Press the MENU button to enter the main menu interface. 2. Right rotation = Down, left rotation = Up, press = Enter function. Set dimmer curves This function allows you to select preset dimmer curves as well as custom dimmer curves. Menu DMX Mode Dimmer Advance Menu>Dimmer Curve 1.0 Mode Standard Stage TV Architecture Theatre To set preset dimmer curves: 1. Press the MENU button to enter the main menu. 2. Press the UP or DOWN button to select Dimmer menu and press ENTER. 3. Press DOWN menu and select Mode sub menu. 4. Select disired dimmer mode. Custom dimmer curves: 1. Press the MENU button to enter the main menu. 2. Press the UP or DOWN button to select Dimmer menu and press ENTER. 3. Press DOWN menu and select Mode sub menu. 4. Press the UP or DOWN button to select Custom menu and press ENTER. 5. Adjust fade in and fade out time to customize yout dimmer curves. Time vary from 150 ms to 2230 ms. avtechsmart.com 10 V1.1 SW2.4 Studio Panel DMX Protocol 2 Channels Mode CH1 CH2 Function WW CW Function Control 000-255: 0-100% dimmer 000-255: 0-100% dimmer 5 Channels Mode CH1 CH2 CH3 CH4 CH5 Function Dimmer Strobe WW CW Color temperature Function Control 000-255: 0-100% dimmer 000-255: from slow to fast 000-255: 0-100% warm white dimmer 000-255: 0-100% cold white dimmer 000-255: Color temperature 3200K - 5600K Fixture Cleaning Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output. To clean the fixture: 1. Disconnect the fixture from power and allow it to cool for at least 10 minutes. 2. Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pres- sure compressed air. 3. Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak deter- gent solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water. 4. Check that the fixture is dry before reapplying power. avtechsmart.com 11 V1.1 SW2.4 Studio Panel Troubleshooting Listed below are a few common problems that you may encounter, with solutions. The fixture does not work, no light · Check the connection of power and main fuse. Be sure the external fuse has not blown. · Measure the mains voltage on the main connector. Technical specifications Model Power supply: Light source: Power consumption: Color temperature: Color Rendition: Power connection: Signal connection: DMX channels: Control mode: Housing: Size: N.W.(barndoor incl.): Accessories(included): Enviroment: PANEL150TW AC100-240V, 50/60Hz 720 x 2 SMD LED 150Watt max. 3200K - 5600K tunable CRI 95, TLCI 98 PowerCON in & out 3-pin XLR in & out 2, 5 CH DMX, RDM, Rotary Colour black, aluminum 398 x 150 x 299 mm 5.5 kg Power lead, Safety rope, Barndoor IP20 Please note: All information is subject to change without prior notice 30062021 avtechsmart.com 12 V1.1 SW2.4Adobe InDesign 16.4 (Windows) Adobe PDF Library 16.0