Important Safe Information

  1. Please read this instruction and assemble the steam shower according to it.
  2. The leakage protection switch must be installed. Besides, please try it to check whether it is safe enough before formal using.
  3. To avoid being shocked by the electricity, users are not allowed to install or replace wires by themselves, please ask a professional electrical engineer to do such work.
  4. The ground line of the product must be connected to the earth permanently.
  5. There is a ground wire on the pump, to avoid being shocked by the electricity, users should connect this wire to the ground. The diameter of the copper-core wire shouldn't less than 1.5 square millimeters.
  6. To avoid being hurt, it is strictly forbidden to touch the pump while it is working.
  7. It is not allowed to refit, append or scissor the steam shower and bathtub.
  8. It is strictly forbidden to use the steam shower after drinking or eating some hypnotic medicine.
  9. Children should be guided by parents while using.
  10. Do not use any strong chemical liquid such as Vitriol, Hydrochloric acid, Lye and so on to clean the steam shower.
  11. Please be sure the water level should be above all the jets before pressing the Pump Key.
  12. If you use the massage function, please be sure not to block the Water Filter.
  13. If the steam shower with 3KW/4.5KW/6KW steam generator, the diameters of wires which are used not less than 2.5 square millimeter/ 4 square millimeter/ 6 square millimeter.
  14. Especially note: The using water temperature should not pass 60 centigrade or 140 Fahrenheit.
  15. Warning: To avoid being shocked by the electricity, please be sure to connect the DFCI/RCD to the ground plug. It is not allowed to take off the Self-cleaning Cup Lid during using the steam function, or the steam will jet out to hurt users.

Installation Wiring Diagram

The diagram illustrates the electrical connections for the steam shower system. Key components include:

Wiring color codes are indicated: Blue (N) for neutral, Brown (L) for live, and Yellow/Green (GND) for ground. For a 240V system, White (L1) and Black (L2) are used for live connections, with Green for ground.

Electrical Parts Specification

Configuration Parameter Massage Pump Steam Generator Ceiling Light Exhausting Fan Solenoid Valves CPU Speaker Note
Rating voltage AC220-240V/50HZ AC220-240V/50HZ DC12V DC12V DC12V AC220V-240V/50HZ
Rating voltage AC110-120V/60HZ AC240V/60HZ DC12V DC12V DC12V AC240V/60HZ
Rating power 900W 3000W 10W 3W 5W 10W
Rating power 900W 4500W 10W 3W 5W 10W
Rating power 900W 6000W 10W 3W 5W 10W

Contents

  1. 01-02: Component Directions
  2. 03: Technical Drawing
  3. 04-10: Installation steps
  4. 11-12: Control panel keys and function directions
  5. 13: Illustration for cleaning function
  6. 14: Maintenance service card
  7. 16: Troubles shooting

Parts Instruction

Parts Package

Hardware and fasteners included:

Main Components

The following parts are included in the steam shower package:

  1. 1/4" Copper elbow
  2. 1/2" Copper screw nuts
  3. 4' Plastic gasket
  4. 90x90 Ventilator
  5. Top cover
  6. Shower head
  7. Mid back panel
  8. F8 control panel
  9. Left side panel
  10. Square 4 ways faucet
  11. Tempered glass shelf
  12. Square jet
  13. Control valve
  14. Air control valve
  15. Waste drainer
  16. Whirlpool bathtub
  17. Colorful light 18grains
  18. Bathtub jet
  19. WTC120AB pump
  20. Bathtub skirt
  21. Upper aluminum profile
  22. Corner aluminum profile
  23. Left fixed door
  24. Movable door aluminum profile
  25. H-style handle
  26. Movable door
  27. Wheel
  28. Loud speaker
  29. Up and down hand shower bracket
  30. Hand shower
  31. Cleaning cup
  32. Right back panel
  33. Steam mouth
  34. Filter
  35. Adjustable leg
  36. Bottom aluminum track

Technical Drawing for Water and Electricity

Dimensions: 1500mm × 1500mm × 2260mm.

The drawing shows the overall dimensions of the shower unit and indicates connection points for hot water, cold water, and electrical sockets. Key measurements include height (2260mm), width (1500mm), and depth. Water connection points are labeled for hot water, cold water, and overflow/drainage. Electrical sockets are also indicated.

Installation Instructions

Installation Instruction 1: Install the Shower Base

  1. Take the shower base out from the carton and place it on the floor carefully.
  2. Use a level ruler on the shower base to check for level. Adjust the adjustable legs if the shower base is not horizontal. (Illustrated in drawing A).

Installation Instruction 2: Install the Back Panels

  1. Take the No.1 panel out of the carton and place it on the shower base carefully. Ensure one person stands by to hold it safely.
  2. Take the No.2 mid panel and place it beside the No.1 back panel. Insert the No.2 panel into the aluminum profile of the No.1 back panel. With one person holding the No.1 and No.2 panels, use a Phillips screwdriver to fix them with 4x10mm self-locking screws. (Illustrated in drawing A).
  3. Repeat the process to fix the No.3 right back panel to the No.2 mid back panel.

Installation Instruction 3: Install Front Fixed Glass Doors

  1. Place the No.1 lower aluminum track on the floor. Slide the No.2 left fixed door into the No.1 track and secure it with 3.5x30mm self-locking screws. (Illustrated in drawing A).
  2. Slide the No.2 left door into the No.4 upper aluminum track and secure it with 3.5x30mm self-locking screws. (Illustrated in drawing A).
  3. Install the No.3 right fixed door to the No.1 and No.4 aluminum tracks using the same method.

Installation Instruction 4: Install the Fixed Glass Doors to the Back Panels and the Shower Base

  1. Attach the No.5 right corner aluminum profile to the No.3 right installed fixed glass doorframe. (Illustrated in drawings A).
  2. Attach the No.6 left corner aluminum profile to the No.2 left installed fixed glass doorframe.
  3. With assistance, carefully place the left and right installed fixed glass doors onto the shower base. One person holds the glass doors while another uses a Phillips screwdriver to fix them to the left and right back glass panels with 4x10mm self-locking screws. (Illustrated in drawing B).

Installation Instruction 5: Install Movable Door

  1. Hang the movable door onto the upper aluminum track (Illustrated in drawing A). Press the lower wheel to hook it into the lower aluminum track (Illustrated in drawing B). Note: There is a spring in the upper wheel. If there is a gap between the movable door and the fixed door, or the movable door does not swing well, adjust the upper wheels.
  2. Adjustment Method: Use a Phillips screwdriver to adjust the screw at the bottom of the upper wheel to make the movable door vertical.
  3. Install the handles using a Hexangular Wrench. (Illustrated in drawing C).

Installation Instruction 6: Install Accessories

  1. Install the Glass Shelf: Use a Phillips screwdriver to fix the glass clip to the back panel using 4x16mm screws, 4mm plastic cushion, 6mm plastic cushion, and 4mm nuts. Place the glass shelf on the clip and secure it. (Illustrated in drawings A and B).
  2. Install the Up and Down Hand Shower Socket: Use a Phillips screwdriver to install the socket to the back panel using 4x16mm screws, 4mm plastic cushion, 6mm plastic cushion, and 4mm nuts. (Illustrated in drawing C).
  3. Connect the hand shower chain to the hand shower socket. (Illustrated in drawing D).
  4. Fix the back panels to the shower base using 6x30mm screws, 6mm spring cushion, 12mm stainless steel cushion, etc. (Illustrated in drawing E).

Installation Instruction 7: Connect Wires

  1. Place the top cover onto the steam shower carefully (Illustrated in drawing A).
  2. Use a Phillips screwdriver to fix the Top Cover to the Back Panels with 4x10mm self-locking screws and Stainless Steel Cushion. (Illustrated in drawing B).
  3. Locate the Ventilator, Lamp, and Loud Speaker signs on the back panel. Connect the corresponding wires from these spare parts to the relative sockets. (Illustrated in the following drawing).

Installation Instruction 8: Connect Fittings and Water Pipes

  1. Connect the head shower pipe to the head shower joint. Connect the water outlet pipe to the shower base and the steam pipe to the steam outlet. (Illustrated in drawing A).
  2. Connect the hot water inlet pipe and the cold water inlet pipe separately to their respective joints. (Illustrated in drawings A, B, and C).
  3. Note: The thermostatic faucet is an optional function. Standard steam showers are supplied without this feature. (Illustrated in drawings D and E).

F8 Control Panel Keys and Operating Instructions

The F8 control panel allows users to manage various functions of the steam shower. The display typically shows temperature and time settings.

1. Power Key ?

Press the Power key to switch the steam room on. Press again to switch it off. The steam room will shut down automatically in 60 minutes. (As shown in Picture 1).

2. Steam Key ▶️

Press the Steam key to start the steam generator. The temperature will be shown on the control panel. (As shown in Picture 2).

3. Time Adjusting ⏱️

After the steam function is turned on, press the Time Up key to increase the setting time. Pressing and holding the key for more than 1 second will increase the time continuously. The time setting range is between 5-50 minutes, with a default of 30 minutes. (As shown in Picture 3).

4. Temperature Adjusting Key ?️

After the steam function is turned on, press the Temperature Up key to increase the temperature. Pressing and holding the key for more than 1 second will increase the temperature continuously. The setting range is between 20°C-50°C, with a controlled temperature tolerance of ±3°C. The default temperature is 40°C. (As shown in Picture 4).

5. Ventilator Key ?

Press the Ventilator key to turn on the ventilator. Press again to turn it off. (As shown in Picture 5).

6. Color Light Key ?

Press the Color Light key to turn on the colored light. Each subsequent press cycles through different colors: blue, blue-red, red, red-orange, orange, orange-blue, and then circulates before turning off. (As shown in Picture 6).

7. Lamp Key ?

Press the Lamp key to turn on the lamp. Press again to turn it off. (As shown in Picture 6).

8. Radio Key ?

Press the Radio key to turn on the radio. Press again to turn it off. (As shown in Picture 7).

9. Channel Memory Key ?

Press and release within 1 second to change the frequency of the current channel. Press and hold for more than 1 second to save the current channel. Up to 8 channels can be memorized. (As shown in Picture 10).

10. Select Key ?️

This key has dual functions. When the radio is on, it switches between frequency and volume display. Pressing the key toggles between frequency (Picture 10) and volume (Picture 9) displays. (As shown in Picture 8).

11. Volume Up Key ➕

When the radio is on (Picture 9 displayed), press the Volume Up key to increase the volume. Holding the key for more than 1 second will continuously increase the volume until released. When Picture 10 is displayed, this key increases the frequency. Holding it for more than 1 second continuously increases the frequency until released.

12. Volume Down Key ➖

When the radio is on (Picture 9 displayed), press the Volume Down key to decrease the volume. Holding the key for more than 1 second will continuously decrease the volume until released. When Picture 10 is displayed, this key decreases the frequency. Holding it for more than 1 second continuously decreases the frequency until released. (As shown in Picture 10).

User's Manual for Cleaning the Steam Generator

Follow these steps for self-cleaning the steam generator:

  1. Power Off: Turn off the power first. For safety, do not open the cleaning cup lid during use. Shut down all other functions before using the cleaning function. (As shown in Picture 11).
  2. Open the Easy Cleaning Cup: After ensuring all functions are off, locate the cleaning cup. Rotate the lid counter-clockwise and remove it. (As shown in Picture 12).
  3. Put the Cleaning Liquid: Use a spoon to add a proper amount of cleaning liquid (e.g., Citric acid or neutral compound cleaning liquid, around 5 ml) into the cleaning cup. If the cleaning material is solid, dissolve it with water first to prevent blocking. Strictly prohibit using any other acid or alkaline compounds. (As shown in Picture 13).
  4. Cover the Lid: Cover the lid back and turn it clockwise to fasten. This prevents steam from escaping and scalding users. (As shown in Picture 14).
  5. Turn On and Start the Steam Function: After covering the lid, press the Steam key to turn on the steam generator. The system will begin to clean the steam box automatically. (As shown in Picture 15).
  6. Turn Off the Power and Drain Out the Waste Water: After 5-10 minutes, press the Power key to turn off the steam generator. Then press the Drain key; the waste water will be drained out automatically. (As shown in Picture 16).

Notice:

Maintenance Service Card

This card is for recording maintenance and repair information. It includes fields for:

EAGO Guarantees: EAGO products are guaranteed against defects for one year from the purchasing date, provided the maintenance service card and purchasing receipt are presented. Free maintenance or part replacement is offered for quality issues. Charges apply for repairs beyond the warranty period or for issues not caused by product defects.

The first page is kept for the customer. The second page is sent back to EAGO head office.

Steam Shower Room Trouble Shooting

Malfunction Status Reasons Solutions
Small volume inlet water 1. Lower inlet water pressure
2. The water inlet pipe is blocked
1. Check the inlet water pressure, then consult a local plumber.
2. Clean the filter.
Water divert valve can't divert water 1. Rubber inside the valve damaged or distorted 1. Change to a new one.
No signal on the control panel 1. No power in the user's house or the wire is not connected well.
2. Not switched the power on.
3. The connecting wire for the control panel is loose.
1. Ensure power is on, connect wires correctly.
2. Switch on the power.
3. Take it off and install it again, ensuring it is fastened properly.
There is steam signal on the control panel, but no steam comes out 1. The Temperature limiter operates or the heater is broken. 1. Ask for help from qualified personnel.
Chromatherapy light doesn't work 1. The connecting wire blew out or the lamp holder is loose.
2. Lamp panel is broken.
1. Change to a new one or install it properly again.
2. Change a new one.
Ventilator doesn't work 1. The connecting wire is off.
2. The fan blade gets stuck.
3. The ventilation fan is broken.
1. Reconnect it well.
2. Slightly turn the fan blades when the fan is on.
3. Change a new one.