Manufacturer: EAGO Sanitary Ware Co., Ltd.
National Service Hotline: 800-8301359
The diagram illustrates the electrical connections for the steam shower system. Key components include:
Wiring color codes are indicated: Blue (N) for neutral, Brown (L) for live, and Yellow/Green (GND) for ground. For a 240V system, White (L1) and Black (L2) are used for live connections, with Green for ground.
| Configuration Parameter | Massage Pump | Steam Generator | Ceiling Light | Exhausting Fan | Solenoid Valves | CPU | Speaker | Note |
|---|---|---|---|---|---|---|---|---|
| Rating voltage | AC220-240V/50HZ | AC220-240V/50HZ | DC12V | DC12V | DC12V | AC220V-240V/50HZ | ||
| Rating voltage | AC110-120V/60HZ | AC240V/60HZ | DC12V | DC12V | DC12V | AC240V/60HZ | ||
| Rating power | 900W | 3000W | 10W | 3W | 5W | 10W | ||
| Rating power | 900W | 4500W | 10W | 3W | 5W | 10W | ||
| Rating power | 900W | 6000W | 10W | 3W | 5W | 10W |
Hardware and fasteners included:
The following parts are included in the steam shower package:
Dimensions: 1500mm × 1500mm × 2260mm.
The drawing shows the overall dimensions of the shower unit and indicates connection points for hot water, cold water, and electrical sockets. Key measurements include height (2260mm), width (1500mm), and depth. Water connection points are labeled for hot water, cold water, and overflow/drainage. Electrical sockets are also indicated.
The F8 control panel allows users to manage various functions of the steam shower. The display typically shows temperature and time settings.
Press the Power key to switch the steam room on. Press again to switch it off. The steam room will shut down automatically in 60 minutes. (As shown in Picture 1).
Press the Steam key to start the steam generator. The temperature will be shown on the control panel. (As shown in Picture 2).
After the steam function is turned on, press the Time Up key to increase the setting time. Pressing and holding the key for more than 1 second will increase the time continuously. The time setting range is between 5-50 minutes, with a default of 30 minutes. (As shown in Picture 3).
After the steam function is turned on, press the Temperature Up key to increase the temperature. Pressing and holding the key for more than 1 second will increase the temperature continuously. The setting range is between 20°C-50°C, with a controlled temperature tolerance of ±3°C. The default temperature is 40°C. (As shown in Picture 4).
Press the Ventilator key to turn on the ventilator. Press again to turn it off. (As shown in Picture 5).
Press the Color Light key to turn on the colored light. Each subsequent press cycles through different colors: blue, blue-red, red, red-orange, orange, orange-blue, and then circulates before turning off. (As shown in Picture 6).
Press the Lamp key to turn on the lamp. Press again to turn it off. (As shown in Picture 6).
Press the Radio key to turn on the radio. Press again to turn it off. (As shown in Picture 7).
Press and release within 1 second to change the frequency of the current channel. Press and hold for more than 1 second to save the current channel. Up to 8 channels can be memorized. (As shown in Picture 10).
This key has dual functions. When the radio is on, it switches between frequency and volume display. Pressing the key toggles between frequency (Picture 10) and volume (Picture 9) displays. (As shown in Picture 8).
When the radio is on (Picture 9 displayed), press the Volume Up key to increase the volume. Holding the key for more than 1 second will continuously increase the volume until released. When Picture 10 is displayed, this key increases the frequency. Holding it for more than 1 second continuously increases the frequency until released.
When the radio is on (Picture 9 displayed), press the Volume Down key to decrease the volume. Holding the key for more than 1 second will continuously decrease the volume until released. When Picture 10 is displayed, this key decreases the frequency. Holding it for more than 1 second continuously decreases the frequency until released. (As shown in Picture 10).
Follow these steps for self-cleaning the steam generator:
Notice:
This card is for recording maintenance and repair information. It includes fields for:
EAGO Guarantees: EAGO products are guaranteed against defects for one year from the purchasing date, provided the maintenance service card and purchasing receipt are presented. Free maintenance or part replacement is offered for quality issues. Charges apply for repairs beyond the warranty period or for issues not caused by product defects.
The first page is kept for the customer. The second page is sent back to EAGO head office.
| Malfunction Status | Reasons | Solutions |
|---|---|---|
| Small volume inlet water | 1. Lower inlet water pressure 2. The water inlet pipe is blocked |
1. Check the inlet water pressure, then consult a local plumber. 2. Clean the filter. |
| Water divert valve can't divert water | 1. Rubber inside the valve damaged or distorted | 1. Change to a new one. |
| No signal on the control panel | 1. No power in the user's house or the wire is not connected well. 2. Not switched the power on. 3. The connecting wire for the control panel is loose. |
1. Ensure power is on, connect wires correctly. 2. Switch on the power. 3. Take it off and install it again, ensuring it is fastened properly. |
| There is steam signal on the control panel, but no steam comes out | 1. The Temperature limiter operates or the heater is broken. | 1. Ask for help from qualified personnel. |
| Chromatherapy light doesn't work | 1. The connecting wire blew out or the lamp holder is loose. 2. Lamp panel is broken. |
1. Change to a new one or install it properly again. 2. Change a new one. |
| Ventilator doesn't work | 1. The connecting wire is off. 2. The fan blade gets stuck. 3. The ventilation fan is broken. |
1. Reconnect it well. 2. Slightly turn the fan blades when the fan is on. 3. Change a new one. |