R-006-DZ-8W-FSU
Fiber Indoor cable, TeraSPEED® Riser Distribution, interlocking aluminum armored with riser jacket, 6 fiber single-unit, Gel-free, Singlemode G.652.D and G.657.A1, Feet jacket marking
Product Classification
- Regional Availability
- Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America
- Portfolio
- CommScope®
- Product Type
- Fiber indoor cable
- Product Series
- R-DZ
General Specifications
- Armor Type
- Interlocking aluminum
- Cable Type
- Distribution
- Construction Type
- Armored
- Subunit Type
- Gel-free
- Jacket Marking
- Feet
- Total Fiber Count
- 6
Dimensions
- Diameter Over Armor
- 10.8 mm | 0.425 in
- Diameter Over Jacket
- 12.8 mm | 0.504 in
Cable Construction
The cable features an outer jacket, an interlocking aluminum armor layer, and an internal riser distribution cable.
Mechanical Specifications
- Minimum Bend Radius, loaded
- 257 mm | 10.118 in
- Minimum Bend Radius, unloaded
- 180 mm | 7.087 in
- Tensile Load, long term, maximum
- 200 N | 44.962 lbf
- Tensile Load, short term, maximum
- 667 N | 149.948 lbf
- Compression
- 85 N/mm | 485.363 lb/in
- Compression Test Method
- FOTP-41 | IEC 60794-1 E3
- Flex
- 25 cycles
- Flex Test Method
- FOTP-104 | IEC 60794-1 E6
- Impact
- 35 N-m | 309.776 in lb
- Impact Test Method
- FOTP-25 | IEC 60794-1 E4
- Strain
- See long and short term tensile loads
- Strain Test Method
- FOTP-33 | IEC 60794-1 E1
- Twist
- 10 cycles
- Twist Test Method
- FOTP-85 | IEC 60794-1 E7
- Vertical Rise, maximum
- 150 m | 492.126 ft
Optical Specifications
- Fiber Type
- G.652.D and G.657.A1, TeraSPEED®
Environmental Specifications
- Installation temperature
- -20 °C to +70 °C (-4 °F to +158 °F)
- Operating Temperature
- -20 °C to +70 °C (-4 °F to +158 °F)
- Storage Temperature
- -40 °C to +70 °C (-40 °F to +158 °F)
- Cable Qualification Standards
- ANSI/ICEA S-83-596 | Telcordia GR-409
- Environmental Space
- Riser
- Flame Test Listing
- NEC OFCR (ETL) and c(ETL)
- Flame Test Method
- UL 1666
Environmental Test Specifications
- Heat Age
- -20 °C to +85 °C (-4 °F to +185 °F)
- Heat Age Test Method
- IEC 60794-1 F9
- Low High Bend
- -20 °C to +70 °C (-4 °F to +158 °F)
- Low High Bend Test Method
- FOTP-37 | IEC 60794-1 E11
- Temperature Cycle
- -20 °C to +70 °C (-4 °F to +158 °F)
- Temperature Cycle Test Method
- FOTP-3 | IEC 60794-1 F1
Packaging and Weights
- Cable weight
- 136 kg/km | 91.388 lb/kft
Regulatory Compliance/Certifications
- Agency
- ISO 9001:2015
- Classification
- Designed, manufactured and/or distributed under this quality management system
Included Products
- CS-8W-TB
- TeraSPEED® Singlemode Fiber
Footnotes
- Operating Temperature
- Specification applicable to non-terminated bulk fiber cable