Instructions for COMMSCOPE models including: P040-0097 Top Mounting Kits, P040-0097, Top Mounting Kits, Mounting Kits, Kits
MC-MNT-SIDE-370 | CommScope
File Info : application/pdf, 9 Pages, 2.55MB
DocumentDocumentP040-0097 Revision A, October 2023 Mounting Kits For Small cell Antennas MC-MNT-SIDE-370: Mounting systems for cylindrical pipe installations (50-250mm pipe diameter) Suitable for small cell cylindrical antennas with a weight less than 20KG and dimensions less than diameter*height: 370*610mm. Installation Preparations All fasteners must be tightended to the defined torque value after onsite installation, see mounting kit installation diagrams on following pages for correct torque recommendations. Installation tools list Figure 1 Installation tools lists Torque wrench Table 1 Installation tools lists Tool Torque wrench Socket Torque wrench Socket Torque wrench Socket Size 10mm 10mm 19mm 19mm 36mm 36mm 10mm 19mm 36mm Torque Range 14Nm(11ft.lbs) 14Nm(11ft.lbs) 58Nm(43ft.lbs) 58Nm(43ft.lbs) 100Nm(74ft.lbs) 100Nm(74ft.lbs) www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 1 of 9 ITEM NO. DESCRIPTION 1 MOUNTING BRACKET,W/GASKET 2 POLE CLAMP,MAIN BODY 3 POLE CLAMP,MAIN BODY 4 SCR,HCS,HEX,M24X80,STL,GALV 5 SCR,HCS,HEX,M6X40,SST,PASS QTY U/M 1 EA 1 EA 1 EA 1 EA 2 EA 6 BOLT,CARRIAGE,M12X270,STL,GALV 2 EA 7 BOLT,CARRIAGE,M12X45,STL,GALV 8 WSHR,FLT,M24,25X44X4,STL,GALV 9 WSHR,FLAT,M6,6.4x12x1.6,SST,PASS 10 WSHR,FLAT,M12,13X40X6,STL,GALV 11 WSHR,FLT,M12,13X24X2.5,STL,GALV 12 NUT,HEX,M24,STL,GALV 13 NUT,HEX,M6-1,SST,PASS 14 NUT,HEX,M12,STL,GALV 15 WSHR,FLAT,M24,25X100X5 STL,GALV 4 EA 1 EA 4 EA 2 EA 4 EA 2 EA 4 EA 12 EA 1 EA Part Lists P040-0097 IMAGE www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 2 of 9 Step 1 : open carton P040-0097 Step 2 : remove cushions & fasteners & pole clamps 4 8 12 1X M24 6 10 14 2X M12 7 11 14 5 9 13 2X M6 4X M12 15 Pack fasteners in small bags, then put them in large bags MC-MNT-SIDE-370 www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 3 of 9 ATTENTION: Measure pole diameter to choose screw holes prior to assembly. P040-0097 Installation hole position Pole is 50mm~100mm, use the inside screw holes for the bolts PIPE DIAMETER www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 4 of 9 ATTENTION: Measure pole diameter to choose screw holes prior to assembly. P040-0097 Installation hole position Pole is 101mm~250mm, use the outside screw holes for the bolts PIPE DIAMETER www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 5 of 9 GENERAL INFORMATION After removing the antenna from its shipping container carefully inspect it to ensure there is no shipping damage. If the antenna is to be hoisted into position, ensure the lifting eye bolt is correctly installed. Ensure the antenna is securely held during hoisting to avoid rotation on the lifting eye bolt. P040-0097 INSTALLATION INSTRUCTIONS Refer to Figures 2 and 3 for mounting and arrow direction. It is recommended that the mounting holes be marked and made ready in the mounting surface prior to installing the antenna. The arrow of each antenna is shown on brakcet one side. The direction of each antenna must be considered prior to mounting to ensure desired performance. Radome Warning: loosening or removing bolts that attach mounting plate to antenna will void warranty and may result in product damage or personal injury Recommened hardware is M6 Mounting Holes 8 mm Asymmetric in 3 positions Radome Connection Fasterner (Do not revmoe) Bracket Figure 1. Small cell CommScope base station antennas Recommened hardware is M24 Mounting Holes 25 mm Asymmetric in 1 positions Figure 2. Mounting Holes on Brakcet Viewed From Bottom Side of Antenna Recommend spacing between pole top end and pipe clamp bracket upper surface. 50mm-130mm Figure 3. Pole And Clamp Distance MC-MNT-SIDE-370 www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 6 of 9 REQUIRED TORQUE M6 M12 M24 14N.m (11ft.lbs) 58N.m (43ft.lbs) 100N.m (74ft.lbs) Method 1: Install the antenna on the pole P040-0097 STEP 1 : Install the mounting kit on the pole 1 7 3 2 Step 2 : install small cell antenna on the bracket surface with M24 bolt and nuts. 6 11 58N.m (43ft.lbs) 14 12 10 14 58N.m (43ft.lbs) 8 15 4 Step 3 : Make sure the direction and install the M6 bolt and nuts Step 4: Tighten the M24 nuts to 100 Nm 13 9 9 5 MC-MNT-SIDE-370 www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 7 of 9 REQUIRED TORQUE M6 14N.m (37ft.lbs) Step 5: Tighten the M6 nuts to 14 Nm P040-0097 Step 6 : Choose a convenient location to install another M6 fastener, then tighten the M6 nuts to 14 Nm 13 9 5 Method 2: Install the antenna on the wall Antenna installation method reference method 1 WALL WALL Install expansion screws at these 3 fixing holes (expansion screws customer prepare) MC-MNT-SIDE-370 www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 8 of 9 Use inclinometer to verify antenna is truly vertical MC-MNT-SIDE-370 Make sure the two clamp brackets are parallel P040-0097 SAFETY NOTICE MC-MNT-SIDE-370 The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. CommScope installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and condition of equipment. CommScope disclaims any liability or responsibility for the results of improper or unsafe installation practices. It is recommended that transmit power be turned off when the field installation is performed. Follow all applicable safety precautions as shown on this page. Do not install near power lines. Power lines, telephone lines, and guy wires look the same. Assume any wire or line can electrocute you. Do not install on a wet or windy day or when lightning or thunder is in the area. Do not use metal ladder. Wear shoes with rubber soles and heels. Wear protective clothing including a long-sleeved shirt and rubber gloves. www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23) Page 9 of 9