Instructions for COMMSCOPE models including: P040-0097 Top Mounting Kits, P040-0097, Top Mounting Kits, Mounting Kits, Kits

P040-0097

COMMSCOPE\convsrvr (GPR1PAPEDLNT06)

P040-0097 Top Mounting Kits For Small cell Antennas H: 610 mm x D; 397 mm

MC-MNT-SIDE-370 | CommScope


File Info : application/pdf, 9 Pages, 2.55MB

PDF preview unavailable. Download the PDF instead.

p040-0097-top-mounting-kits-for-small-cell-antennas-h-610-mm-x-d-397-mm
P040-0097 Revision A, October 2023 Mounting Kits For Small cell Antennas
MC-MNT-SIDE-370: Mounting systems for cylindrical pipe installations (50-250mm pipe diameter) Suitable for small cell cylindrical antennas with a weight less than 20KG and dimensions less than diameter*height: 370*610mm.

Installation Preparations
All fasteners must be tightended to the defined torque value after onsite installation, see mounting kit installation diagrams on following pages for correct torque recommendations.
Installation tools list Figure 1 Installation tools lists

Torque wrench
Table 1 Installation tools lists

Tool Torque wrench
Socket Torque wrench
Socket Torque wrench
Socket

Size 10mm 10mm 19mm 19mm 36mm 36mm

10mm 19mm 36mm
Torque Range 14Nm(11ft.lbs) 14Nm(11ft.lbs) 58Nm(43ft.lbs) 58Nm(43ft.lbs) 100Nm(74ft.lbs) 100Nm(74ft.lbs)

www.commscope.com © 2023 CommScope, Inc. All rights reserved.
Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information.
All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 1 of 9

ITEM NO.

DESCRIPTION

1

MOUNTING BRACKET,W/GASKET

2

POLE CLAMP,MAIN BODY

3

POLE CLAMP,MAIN BODY

4

SCR,HCS,HEX,M24X80,STL,GALV

5

SCR,HCS,HEX,M6X40,SST,PASS

QTY

U/M

1

EA

1

EA

1

EA

1

EA

2

EA

6

BOLT,CARRIAGE,M12X270,STL,GALV

2

EA

7

BOLT,CARRIAGE,M12X45,STL,GALV

8

WSHR,FLT,M24,25X44X4,STL,GALV

9

WSHR,FLAT,M6,6.4x12x1.6,SST,PASS

10

WSHR,FLAT,M12,13X40X6,STL,GALV

11

WSHR,FLT,M12,13X24X2.5,STL,GALV

12

NUT,HEX,M24,STL,GALV

13

NUT,HEX,M6-1,SST,PASS

14

NUT,HEX,M12,STL,GALV

15

WSHR,FLAT,M24,25X100X5 STL,GALV

4

EA

1

EA

4

EA

2

EA

4

EA

2

EA

4

EA

12

EA

1

EA

Part Lists

P040-0097
IMAGE

www.commscope.com © 2023 CommScope, Inc. All rights reserved.
Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information.
All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 2 of 9

Step 1 : open carton

P040-0097

Step 2 : remove cushions & fasteners & pole clamps

4 8 12
1X M24

6 10 14

2X M12

7

11

14

5 9 13
2X M6

4X M12
15
Pack fasteners in small bags, then put them in large bags

MC-MNT-SIDE-370
www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 3 of 9

ATTENTION: Measure pole diameter to choose screw holes prior to assembly.

P040-0097

Installation hole position

Pole is 50mm~100mm, use the inside screw holes for the bolts
PIPE DIAMETER
www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 4 of 9

ATTENTION: Measure pole diameter to choose screw holes prior to assembly.

P040-0097

Installation hole position

Pole is 101mm~250mm, use the outside screw holes for the bolts
PIPE DIAMETER
www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 5 of 9

GENERAL INFORMATION
After removing the antenna from its shipping container carefully inspect it to ensure there is no shipping damage. If the antenna is to be hoisted into position, ensure the lifting eye bolt is correctly installed. Ensure the antenna is securely held during hoisting to avoid rotation on the lifting eye bolt.

P040-0097
INSTALLATION INSTRUCTIONS
Refer to Figures 2 and 3 for mounting and arrow direction. It is recommended that the mounting holes be marked and made ready in the mounting surface prior to installing the antenna. The arrow of each antenna is shown on brakcet one side. The direction of each antenna must be considered prior to mounting to ensure desired performance.

Radome

Warning: loosening or removing bolts that attach mounting plate to antenna will void warranty and may result in product damage or personal injury

Recommened hardware is M6 Mounting Holes 8 mm
Asymmetric in 3 positions

Radome Connection Fasterner (Do not revmoe)
Bracket
Figure 1. Small cell CommScope base station antennas

Recommened hardware is M24 Mounting Holes 25 mm Asymmetric in 1 positions
Figure 2. Mounting Holes on Brakcet Viewed From Bottom Side of Antenna
Recommend spacing between pole top end and pipe clamp bracket upper surface. 50mm-130mm

Figure 3. Pole And Clamp Distance
MC-MNT-SIDE-370
www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 6 of 9

REQUIRED TORQUE

M6 M12 M24

14N.m (11ft.lbs) 58N.m (43ft.lbs) 100N.m (74ft.lbs)

Method 1: Install the antenna on the pole

P040-0097

STEP 1 : Install the mounting kit on the pole

1

7

3

2

Step 2 : install small cell antenna on the bracket surface with M24 bolt and nuts.

6

11

58N.m (43ft.lbs) 14

12

10

14 58N.m (43ft.lbs)

8

15

4

Step 3 : Make sure the direction and install the M6 bolt and nuts

Step 4: Tighten the M24 nuts to 100 Nm

13 9 9 5

MC-MNT-SIDE-370
www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 7 of 9

REQUIRED TORQUE M6 14N.m (37ft.lbs)
Step 5: Tighten the M6 nuts to 14 Nm

P040-0097
Step 6 : Choose a convenient location to install another M6 fastener, then tighten the M6 nuts to 14 Nm

13 9 5

Method 2: Install the antenna on the wall
Antenna installation method reference method 1

WALL

WALL

Install expansion screws at these 3 fixing holes
(expansion screws customer prepare)

MC-MNT-SIDE-370
www.commscope.com © 2023 CommScope, Inc. All rights reserved. Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information. All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 8 of 9

Use inclinometer to verify antenna is truly vertical
MC-MNT-SIDE-370
Make sure the two clamp brackets are parallel

P040-0097

SAFETY NOTICE

MC-MNT-SIDE-370

The installation, maintenance, or removal of an antenna requires qualified, experienced personnel. CommScope installation instructions are written for such installation personnel. Antenna systems should be inspected once a year by qualified personnel to verify proper installation, maintenance, and condition of equipment.

CommScope disclaims any liability or responsibility for the results of improper or unsafe installation practices. It is recommended that transmit power be turned off when the field installation is performed. Follow all applicable safety precautions as shown on this page.

Do not install near power lines. Power lines, telephone lines, and guy wires look the same. Assume any wire or line can electrocute you.

Do not install on a wet or windy day or when lightning or thunder is in the area. Do not use metal ladder.

Wear shoes with rubber soles and heels. Wear protective clothing including a long-sleeved shirt and rubber gloves.

www.commscope.com © 2023 CommScope, Inc. All rights reserved.
Visit our website at www.commscope.com or contact your local CommScope representative or BusinessPartner for more information.
All trademarks identified by ® or TM are registered trademarks or trademarks, respectively, of CommScope, Inc. P040-0097 A (10/23)

Page 9 of 9



References

CIDEON PdfEditor (x64) V 3.7.208.0