Owner's Manual for NuTone models including: FG7TE Series Smartlite Two Stage Fixed Speed ECM High Efficiency Upflow Gas Furnace, FG7TE Series, Smartlite Two Stage Fixed Speed ECM High Efficiency Upflow Gas Furnace, Two Stage Fixed Speed ECM High Efficiency Upflow Gas Furnace, Fixed Speed ECM High Efficiency Upflow Gas Furnace, ECM High Efficiency Upflow Gas Furnace, High Efficiency Upflow Gas Furnace, Upflow Gas Furnace, Gas Furnace, Furnace

TCPDF

FG7TE (FER) Up to 96% AFUE Two Stage, Fixed Speed, High Efficiency Gas Furnace

FG7T(E,N) - FS | Gas Furnace | NuTone | Literature Library

PDF preview unavailable. Download the PDF instead.

469f
TECHNICAL SPECIFICATIONS

FG7TE Series
Smartlite®
Two Stage, Fixed Speed ECM, High Efficiency Upflow Gas Furnaces
Induced Draft - 96% AFUE Input 35,000 - 115,000 Btuh
The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The extended flush jacket provides a pleasing "appliance appearance." Design certified by CSA for application in Canada and the United States.

FEATURES and BENEFITS
· Multi-speed Direct Drive Blower: Energy-efficient brushless DC (ECM) fixed-speed motor offers 16 speeds designed to give a wide range of cooling capacities.
· SmartLite® Technology: Auto-adjusts igniter on time to extend igniter life.
· Hot Surface Igniter: Innovative application of a silicon nitride type igniter.
· 30 Second Blower Delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
· 30 Second Post Purge: Increases life of heat exchanger. · 60 Second Fixed Cooling Cycle Blower-Off Delay
(TDR): Increases cooling performance when matched with a Nortek Global HVAC coil. · Color Coded Wire Harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement. · Diagnostic Lights: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes. · Integrated Control Boards: With connections for electronic air cleaner, humidifier, and dehumidification. Ergonomically located for ease of service. · 2 Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels. · Heat Exchanger: Heavy gauge aluminized steel primary heat exchanger and stainless steel secondary heat exchanger assures a long life. · 100% Fired and Tested: All units and each component are tested on the manufacturing line. · Best Packaging in the Industry: Unique corner post design assures product will arrive to the homeowner dent free. · Flexible Category IV Venting System: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation. · Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install. · LP Convertible: Simple burner orifice and regulator spring change for ease of convertibility (as an accessory). · Two Piece Door Design: Enhances furnace appearance and uses captured screws to prevent losing door screws. · Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation. · Sealed Vestibule: Reduces burner and inducer sound levels. · Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it's needed.

LOCATION OF COMPONENTS
UPFLOW FURNACE (*TE SERIES)

Flame Sensor

Finish Flange

Roll-Out Switch

Burner Assembly

Pressure Switches (Inducer)
Main Air Limit Switch Inducer Limit Switch
Inducer Assembly
Blower Door Switch

AIR FLOW

Igniter
Gas Valve Furnace Control Board
Pressure Switches (Condensate)
Transformer

Motor Control Box
Motor Choke (C & D cabinets only)

1 2 34 5678

Motor Control Board Blower Assembly

DIMENSIONS

Cabinet

Dim.

Dim.

Size

"A"

"B"

`A' Cabinet 14 1/4 12 5/8

`B' Cabinet 17 1/2 15 7/8

`C' Cabinet

21

19 3/8

`D' Cabinet 24 1/2 22 7/8

NOTES:

Dimensions shown in inches.

2 3/4 22 1/2
25 3/8 22 1/2 Vent pipe (Ø 3")

Dim. "C" 12 7/8 16 1/8 19 5/8 23 1/8
3 1/4
T-stat (Ø 7/8) Electric (Ø 7/8)
Gas (Ø 1 5/8)

TOP VIEW B

FLANGES

19

Combustion Air

A

T-stat (Ø 7/8)

Vent pipe (Ø 3")

24 7/8

34 1/2 17 1/4 17 7/8

1

28 LEFT SIDE

Condensate (Ø 1 1/16)

FRONT VIEW

23 1/2

BOTTOM VIEW C
Front Brace
Bottom Panel

Electric (Ø 7/8)

22 1/2 Gas (Ø 1 5/8)

4 Knockouts (both sides) Cond. (Ø 1 1/16)
23 RIGHT SIDE

15 1 1/4

2

Gas Furnace
Design Series
S = Single Stage T = Two Stage
A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal D = 95% Upflow/Horizontal E = 96% Upflow

MODEL IDENTIFICATION CODE
FG 7 T E 080 D E 35 C 1

Revision

Input Heating Capacity 035 = 35,000 060 = 60,000 080 = 80,000 100 = 100,000 115 = 115,000

Cabinet Width A = 14.25 B = 17.50 C = 21.00 D = 24.50
Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons
Motor Technology V = VSHE E = FSHE T = 5 Tap ECM
NOx C/D = 40 Ng/J or less NOx U = 14 Ng/J or less NOx

SPECIFICATIONS

FG7TE MODEL NUMBERS
Input - Btuh (a) Heating Capacity - BtuH AFUE Motor H.P. - Speed - Type Motor FLA Rated Ext. SP - In. W.C. Temperature Rise Range - F Shipping Weights SKU

-035D-E23A1
35000 / 23000 33000 / 22000
96.0 1/2 - BLDC
6.9 0.50 30-60 101 lb 1037159F

-060D-E24B1
60000 / 39000 58000 / 37000
96.0 3/4 - BLDC
8.8 0.50 30-60 120 lb 1025958F

-080D-E35C1
80000 / 52000 77000 / 50000
96.0 1 - BLDC
11.5 0.50 30-60 130 lb 1025959F

Note: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.

-100D-E35C1
100000 / 65000 96000 / 62000
96.0 1 - BLDC
11.5 0.50 35-65 135 lb 1025960F

-115D-E45D1
115000 / 74750 110000 / 72000
96.0 1 - BLDC
11.5 0.50 40-70 145 lb 1025961F

3

BLOWER PERFORMANCE

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

1234

0000

1000

0100

1100

0010

1010

0110

G7TE-035D-E23A1 1 1 1 0

35,000 BTU/hr

0001

1001

0101

1101

0011

1011

0111

1111

0.1

CFM

RISE

560

56

570

55

670

46

700

44

765

41

795

39

845

37

895

35

905

34

950

33

990

31

1010

31

1050

30

External Static Pressure (in.w.c.)

0.2

CFM

RISE

0.3

CFM

RISE

0.4

CFM

RISE

515

60

540

58

635

49

595

52

565

55

670

46

635

49

600

52

725

43

690

45

660

47

755

41

720

43

690

45

810

38

775

40

740

42

860

36

825

38

790

39

870

36

840

37

805

39

920

34

885

35

850

37

955

33

925

34

890

35

980

32

945

33

910

34

1015

31

985

32

955

33

1045

30

1020

31

990

31

0.5

CFM

RISE

525

59

565

55

625

50

650

48

705

44

760

41

770

40

820

38

860

36

885

35

925

34

960

32

COOLING AIRFLOW (CFM)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

5678

0000

1000

0100

1100

0010

1010

0110

G7TE-035D-E23A1 1 1 1 0

35,000 BTU/hr

0001

1001

0101

1101

0011

1011

0111

1111

0.1
CFM
560 570 670 700 765 795 845 895 905 950 990 1010 1050 1080 1105

0.2
CFM
515 540 635 670 725 755 810 860 870 920 955 980 1015 1045 1075

External Static Pressure (in.w.c.)

0.3 CFM

0.4 CFM

0.5 CFM

0.6 CFM

475

505

460

595

565

525

485

635

600

565

530

690

660

625

585

720

690

650

615

775

740

705

675

825

790

760

725

840

805

770

740

885

850

820

785

925

890

860

830

945

910

885

850

985

955

925

895

1020

990

960

930

1045

1015

985

955

0.7 CFM
485 550 580 640 695 700 760 800 820 865 895 920

*NOTES: 1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8. 2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

0.8 CFM
510 545 600 660 670 720 765 790 830 865 895

4

BLOWER PERFORMANCE (Continued)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

1234

0000

1000

0100

1100

0010

1010

0110

G7TE-060D-E24B1 1 1 1 0

60,000 BTU/hr

0001

1001

0101

1101

0011

1011

0111

1111

0.1

CFM

RISE

940

57

990

54

1,055

51

1,135

47

1,185

45

1,250

43

1,290

41

1,315

41

1,350

40

1,390

38

External Static Pressure (in.w.c.)

0.2

CFM

RISE

0.3

CFM

RISE

0.4

CFM

RISE

890

60

945

56

905

59

1,015

53

970

55

930

57

1,095

49

1,055

51

1,010

53

1,145

47

1,105

48

1,065

50

1,210

44

1,170

46

1,135

47

1,255

42

1,220

44

1,180

45

1,275

42

1,240

43

1,200

44

1,315

41

1,280

42

1,245

43

1,350

40

1,315

41

1,275

42

0.5

CFM

RISE

890

60

960

56

1,030

52

1,095

49

1,145

47

1,160

46

1,205

44

1,240

43

COOLING AIRFLOW (CFM)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

5678

0000

1000

0100

1100

0010

1010

0110

G7TE-060D-E24B1 1 1 1 0

60,000 BTU/hr

0001

1001

0101

1101

0011

1011

0111

1111

0.1
CFM
725 810 940 990 1,055 1,135 1,185 1,250 1,290 1,315 1,350 1,390 1,420

0.2 CFM
890 945 1,015 1,095 1,145 1,210 1,255 1,275 1,315 1,350 1,380

External Static Pressure (in.w.c.)

0.3 CFM

0.4 CFM

0.5 CFM

0.6 CFM

845 905 970 1,055 1,105 1,170 1,220 1,240 1,280 1,315 1,345

795 860 930 1,010 1,065 1,135 1,180 1,200 1,245 1,275 1,310

750 820 890 960 1,030 1,095 1,145 1,160 1,205 1,240 1,270

700 775 845 930 990 1,055 1,110 1,120 1,170 1,200 1,235

0.7 CFM
735 805 890 950 1,020 1,075 1,085 1,135 1,160 1,200

*NOTES: 1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8. 2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

0.8 CFM
690 760 850 910 980 1,040 1,045 1,100 1,125 1,160

5

BLOWER PERFORMANCE (Continued)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

1234

0000

1000

0100

1100

0010

1010

0110

FG7TE-080D-E35C1 1 1 1 0

80,000 BTU/hr

0001

1001

0101

1101

0011

1011

0111

1111

0.1

CFM 1,125 1,205 1,305 1,430 1,525 1,620 1,695 1,770 1,875 1,905 1,980 2,025

RISE 63 59 54 50 47 44 42 40 38 37 36 35

External Static Pressure (in.w.c.)

0.2

CFM

RISE

0.3

CFM

RISE

0.4

CFM

RISE

1,120

63

1,225

58

1,150

62

1,350

53

1,270

56

1,190

60

1,450

49

1,375

52

1,300

55

1,540

46

1,465

49

1,390

51

1,620

44

1,545

46

1,465

49

1,700

42

1,630

44

1,555

46

1,805

39

1,730

41

1,655

43

1,840

39

1,775

40

1,710

42

1,910

37

1,845

39

1,780

40

1,960

36

1,895

38

1,830

39

2,025

35

1,960

36

1,900

37

2,010

35

1,945

37

2,035

35

0.5

CFM

RISE

1,110

63

1,225

57

1,315

54

1,390

51

1,485

47

1,580

45

1,640

43

1,715

41

1,765

40

1,840

38

1,880

37

1,980

36

COOLING AIRFLOW (CFM)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

5678

0000

1000

0100

1100

0010

1010

0110

FG7TE-080D-E35C1 1 1 1 0

80,000 BTU/hr

0001

1001

0101

1101

0011

1011

0111

1111

0.1
CFM 1,125 1,205 1,305 1,430 1,525 1,620 1,695 1,770 1,875 1,905 1,980 2,025 2,085 2,135 2,200 2,280

0.2
CFM 1,040 1,120 1,225 1,350 1,450 1,540 1,620 1,700 1,805 1,840 1,910 1,960 2,025 2,070 2,145 2,225

External Static Pressure (in.w.c.)

0.3
CFM 960 1,040 1,150 1,270 1,375 1,465 1,545 1,630 1,730 1,775 1,845 1,895 1,960 2,010 2,090 2,170

0.4
CFM 880 960 1,070 1,190 1,300 1,390 1,465 1,555 1,655 1,710 1,780 1,830 1,900 1,945 2,035 2,115

0.5
CFM 795 875 995 1,110 1,225 1,315 1,390 1,485 1,580 1,640 1,715 1,765 1,840 1,880 1,980 2,065

0.6
CFM
795 915 1,030 1,150 1,240 1,315 1,410 1,510 1,575 1,650 1,700 1,775 1,815 1,925 2,010

0.7
CFM
840 950 1,075 1,165 1,235 1,340 1,435 1,510 1,580 1,635 1,715 1,750 1,870 1,955

*NOTES: 1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8. 2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

0.8
CFM
865 1,000 1,090 1,160 1,265 1,340 1,445 1,515 1,570 1,655 1,685 1,820 1,900

6

BLOWER PERFORMANCE (Continued)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

1234 0000 1000 0100 1100 0010 1010 0110 FG7TE-100D-E35C1 1 1 1 0 100,000 BTU/hr 0 0 0 1 1001 0101 1101 0011 1011 0111 1111

0.1

CFM

RISE

1,620

55

1,695

52

1,770

50

1,875

47

1,905

47

1,980

45

2,025

44

2,085

43

2,135

42

External Static Pressure (in.w.c.)

0.2

CFM

RISE

0.3

CFM

RISE

0.4

CFM

RISE

1,540

58

1,620

55

1,545

58

1,700

52

1,630

55

1,555

57

1,805

49

1,730

51

1,655

54

1,840

48

1,775

50

1,710

52

1,910

47

1,845

48

1,780

50

1,960

45

1,895

47

1,830

49

2,025

44

1,960

45

1,900

47

2,070

43

2,010

44

1,945

46

0.5

CFM

RISE

1,485

60

1,580

56

1,640

54

1,715

52

1,765

50

1,840

48

1,880

47

COOLING AIRFLOW (CFM)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

5678
0000 1000 0100 1100 0010 1010 0110 FG7TE-100D-E35C1 1 1 1 0 100,000 BTU/hr 0 0 0 1 1001 0101 1101 0011 1011 0111 1111

0.1
CFM 1,125 1,205 1,305 1,430 1,525 1,620 1,695 1,770 1,875 1,905 1,980 2,025 2,085 2,135 2,200 2,280

0.2
CFM 1,040 1,120 1,225 1,350 1,450 1,540 1,620 1,700 1,805 1,840 1,910 1,960 2,025 2,070 2,145 2,225

External Static Pressure (in.w.c.)

0.3 CFM

0.4 CFM

0.5 CFM

0.6 CFM

1,040 1,150 1,270 1,375 1,465 1,545 1,630 1,730 1,775 1,845 1,895 1,960 2,010 2,090 2,170

1,070 1,190 1,300 1,390 1,465 1,555 1,655 1,710 1,780 1,830 1,900 1,945 2,035 2,115

995 1,110 1,225 1,315 1,390 1,485 1,580 1,640 1,715 1,765 1,840 1,880 1,980 2,065

1,030 1,150 1,240 1,315 1,410 1,510 1,575 1,650 1,700 1,775 1,815 1,925 2,010

0.7
CFM
1,075 1,165 1,235 1,340 1,435 1,510 1,580 1,635 1,715 1,750 1,870 1,955

*NOTES: 1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8. 2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

0.8
CFM
1,000 1,090 1,160 1,265 1,340 1,445 1,515 1,570 1,655 1,685 1,820 1,900

7

BLOWER PERFORMANCE (Continued)

HEATING AIRFLOW (CFM) & TEMPERATURE RISE (°F)

Model Number/ Heating Input

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)

1234 0000 1000 0100 1100 0010 1010 0110 FG7TE-115D-E45D1 1 1 1 0 115,000 BTU/hr 0 0 0 1 1001 0101 1101 0011 1011 0111 1111

0.1

CFM

RISE

1,760

58

1,835

56

1,885

54

1,945

53

1,950

52

2,075

49

2,125

48

2,170

47

2,215

46

External Static Pressure (in.w.c.)

0.2

CFM

RISE

0.3

CFM

RISE

0.4

CFM

RISE

1,715

60

1,790

57

1,745

59

1,840

56

1,790

57

1,745

59

1,900

54

1,850

55

1,805

57

1,905

54

1,860

55

1,820

56

2,030

50

1,990

51

1,945

53

2,085

49

2,040

50

2,000

51

2,130

48

2,090

49

2,045

50

2,180

47

2,140

48

2,105

49

0.5

CFM

RISE

1,700

60

1,760

58

1,775

58

1,900

54

1,955

52

2,005

51

2,070

49

Model Number/ Heating Input
FG7TE-115D-E45D1 115,000 BTU/hr

MOTOR SWITCH SETTINGS (0=OFF, 1=ON)
5678 0000 1000 0100 1100 0010 1010 0110 1110 0001 1001 0101 1101 0011 1011 0111 1111

0.1
CFM 1,395 1,465 1,555 1,625 1,690 1,760 1,835 1,885 1,945 1,950 2,075 2,125 2,170 2,215

COOLING AIRFLOW (CFM)

External Static Pressure (in.w.c.)

0.2
CFM 1,350 1,420 1,510 1,585 1,650 1,715 1,790 1,840 1,900 1,905 2,030 2,085 2,130 2,180

0.3
CFM 1,305 1,375 1,470 1,540 1,610 1,670 1,745 1,790 1,850 1,860 1,990 2,040 2,090 2,140

0.4
CFM 1,260 1,330 1,425 1,500 1,570 1,625 1,695 1,745 1,805 1,820 1,945 2,000 2,045 2,105

0.5
CFM 1,210 1,290 1,380 1,460 1,530 1,575 1,650 1,700 1,760 1,775 1,900 1,955 2,005 2,070 2,225

0.6
CFM 1,165 1,245 1,340 1,415 1,485 1,530 1,605 1,655 1,710 1,735 1,855 1,910 1,965 2,035 2,165 2,170

0.7
CFM 1,120 1,200 1,295 1,375 1,445 1,485 1,555 1,610 1,665 1,690 1,810 1,870 1,925 2,000 2,100 2,120

*NOTES: 1. Motor switch settings for heating speeds use HEAT switches 1, 2, 3, & 4 and for cooling speeds use COOL switches 5, 6, 7, & 8. 2. To comply with government mandated efficiency standards, two openings are required for airflows above 1,600 CFM. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary. 5. Individual cells shaded in gray indicate a temperature rise outside of the recommended range. 6. To comply with government mandated efficiency standards, speed settings shaded in gray are not allowed in HEAT mode. 7. When in low stage heat, the airflow is approximately 70% of the tables high value (2-stage furnaces only).

0.8
CFM
1,155 1,250 1,335 1,405 1,440 1,510 1,565 1,620 1,650 1,770 1,825 1,880 1,965 2,040 2,065

8

VENTING
All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths.

FURNACE MODELS
(BTU)

FURNACE INSTALLATION

SINGLE PIPE LENGTH (FT.) with 1 long radius elbow**

OUTLET

OUTLET

DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH 1 long radius elbow on each pipe**

INLET/OUTLET

INLET/OUTLET

2" Diameter

3" Diameter

2" Diameter

3" Diameter

35,000

Upflow

60

90

60

90

60,000

Upflow

60

90

60

90

80,000

Upflow

40

90

40

90

100,000

Upflow

30

90

30

90

115,000

Upflow

N/A

90

N/A

90

*NOTES:

1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2" tee and 8ft for each 3" tee.

2. Two 45 degree elbows are equivalent to one 90 degree elbow.

3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.

9

ACCESSORIES

Description 2" Concentric Vent Kit (US & Canada Approved) 3" Concentric Vent Kit (US & Canada Approved) 2" Side Wall Vent Kit 3" Side Wall Vent Kit U.S. LP Conversion Kit (0 to 10,000 ft.) Canada LP Conversion Kit (0 to 4,500 ft.) Bottom Return Filter 20 per Box, "B" Cabinet Bottom Return Filter 20 per Box, "D" Cabinet Side Return Filter Kit Neutralizer Kit

FG7TE KITS

SKU 904952 904953 904617 904347 905028 905029 904916 904918 541036 902377

10

11

GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty.
For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy.

Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (11/2021)

469F-1121 (Replaces 469F-0721)