Instructions for BlueKit models including: Vasectomy Haemostat Forceps, Haemostat Forceps, Forceps
Vasectomy Haemostat Forceps, Sharp, Curved – BlueKit Medical
Dissecting Forceps, Gillies – BlueKit Medical
File Info : application/pdf, 3 Pages, 259.36KB
DocumentDocumentInstructions for Use Document Ref: OPQC/IFU/014/3 Raised by (Name): Grant Porter Signature: Authorised by (Name): Rebecca Porter Signature: Version: 3.1 Position: Operations & Logistics Manager Position: Managing Director Page: 1 Date: 01/04/2022 Date: 01/04/2022 SINGLE-USE SURGICAL INSTRUMENTS: Surgical Forceps Doc OPQC/IFU/014/3 No. Device Intended Use Sterilisation (R) Storage Warnings/Cautions Rev. 3.1 Date of Issue 20/08/22 Last doc review date: 19/12/23 Condition: SINGLE- Condition USE for Use: STERILE Single use surgical soft-tissue manipulation forceps, alligator Single use surgical soft-tissue manipulation forceps, scissors-like Single use ophthalmic soft-tissue manipulation forceps, tweezers-like Single use obstetrical forceps Single use dressing/utility forceps, tweezers-like For professional use. Intended for single use only. Surgical Forceps are hand-held, hinged instruments used for grasping and holding objects and tissues. Needle Holder Forceps are hand-held, hinged instruments used for grasping and holding needles and sutures for stitching during surgical procedures. Thumb, Dressing & Tissue Forceps are a handheld, hinged or tweezer-like instruments used for grasping and holding objects and tissues. Method: Gamma Radiation Radiation Dose 25.00 Min 35.00 Processed under ISO Range: 13485: 2016 procedures Max kGy Instructions DO NOT USE if pack is damaged or open. for Use: 1. Store all instruments as packaged. 2. Do not use if packaging is damaged or open. 3. Ensure all packs are kept in a storage area free of dust, insects, chemical vapours and extreme changes in temperature and humidity. Surgical instruments may be damaged if used for unintended purposes. NEVER: Misuse instruments or overstrain joints or racks. Handle instruments by their tips. These will have been cleaned by trained personnel only who will ensure the delicate working ends are adequately protected during storage or sterilisation. Attempt to clean or use abrasives on instruments as this will spoil the surface finish and compromise sterility. Store instruments with other heavier instruments on top. Always remember to store heavy instruments on the bottom and light instruments on the top. Reuse a single use device as this may result in cross infection or functional failure. BlueKit Medical Limited T 020 8224 2883 | E info@bluekitmedical.com | W www.bluekitmedical.com A Unit 87 Capital Business Centre | 22 Carlton Road | South Croydon | CR2 0BS Company Registered In England 08097913 | VAT Registration No. 141004673 Instructions for Use Document Ref: OPQC/IFU/014/3 Raised by (Name): Grant Porter Signature: Authorised by (Name): Rebecca Porter Signature: Version: 3.1 Position: Operations & Logistics Manager Position: Managing Director Page: 2 Date: 01/04/2022 Date: 01/04/2022 Instructions Always store appropriately, ensuring storage is free of dust, insects, chemical vapours and extreme changes in temperature and humidity. Always check packaging before use to ensure that packaging is not damaged or open. Always check instruments for damage before use. Give special attention to microsurgical instruments: their fine tips can easily be damaged in transit or storage. Ensure all instruments are only used for the purpose for which they were designed. Handle all instruments gently. Never overstrain, drop, or misuse them. Where any serious incident occurs as a result of use, this incident must be reported to the manufacturer and competent authority. Contraindications Shelf Life 1. Use without Sterilisation/ Disinfestation. 2. Rusty conditions visually observed. 3. Re-use of Single Use, whether used on a single patient, another patient, or another surgical procedure occurring at another time. Refer to date of manufacture and date of expiration available on product label. Gamma Irradiation (R) provides sterility for 5 years. Disposal Distributor Packing provided by Sterilisation provided by Regulatory Standards Single use surgical instruments should be disposed of after use. Used single use surgical instruments should be treated as clinical waste and should therefore be disposed of in accordance with and under the care and direction of the healthcare provider's full Policies and Procedures and must be managed strictly in accordance with local healthcare waste management policies and procedures. If decontaminated stainless steel is recyclable in ordinary steel manufacturing units. BlueKit Medical Limited https://bluekitmedical.com Unit 87 Capital Business Centre, 22 Carlton Road, South Croydon, CR2 0BS, England, United Kingdom Granton Medical Limited Parkway Close, Parkway Industrial Estate, Sheffield, S9 4WJ, United Kingdom Swann-Morton Limited Owlerton Green, Sheffield, S6 2BJ, United Kingdom This product is packed in accordance with requirements set out within ISO 14644-1 and processed under ISO 13485: 2016 procedures. All contents are CE marked. Manufacturer Surgicrafts PK Muhammad Pura, Commissioner Road, Sialkot, Pakistan 1639 BlueKit Medical Limited T 020 8224 2883 | E info@bluekitmedical.com | W www.bluekitmedical.com A Unit 87 Capital Business Centre | 22 Carlton Road | South Croydon | CR2 0BS Company Registered In England 08097913 | VAT Registration No. 141004673 Instructions for Use Document Ref: OPQC/IFU/014/3 Raised by (Name): Grant Porter Signature: Authorised by (Name): Rebecca Porter Signature: Version: 3.1 Position: Operations & Logistics Manager Position: Managing Director Page: 3 Date: 01/04/2022 Date: 01/04/2022 EU Representative Manufacturer EU Representative Mr. Manuel Mateos CMC Medical Devices & Drugs S.L, C/ Horacio Lengo n18, C.P 29006, Málaga-Spain S.R.R Surgical PK Airport Road, Kotli Behram, Sialkot 51310, Pakistan 1639 CMC Medical Devices & Drugs S.L 19-21 Crawford Street, London, W1H 1PJ, United Kingdom BlueKit Medical Limited T 020 8224 2883 | E info@bluekitmedical.com | W www.bluekitmedical.com A Unit 87 Capital Business Centre | 22 Carlton Road | South Croydon | CR2 0BS Company Registered In England 08097913 | VAT Registration No. 141004673