User Guide for edge-core models including: ASGvOLT64, ASGvOLT64-QSG-TC, ASGvOLT64-QSG-R01

ASGvOLT64 Quick Start Guide

Edgecore Networks Corporation

ASGvOLT64 Quick Start Guide

ASGvOLT64-QSG-TC. Quick Start Guide. 64-Port GPON vOLT. ... 4. Console cable—RJ-45 to D-Sub 5. ation—Quick Start Guide (this document) and Safety.

19 août 2021 — Quick Start Guide. E082021-MR-R01. 150200002424A. 64-Port GPON vOLT. ASGvOLT64. 1. ASGvOLT64. 2. Rack mounting kit—2 brackets and 24 screws.

PDF preview unavailable. Download the PDF instead.

ASGvOLT64-QSG-R01 EN TC-20210819
Quick Start Guide
64-Port GPON vOLT
ASGvOLT64
Package Contents

www.edge-core.com

1
1. ASGvOLT64 2. Rack mounting kit--2 brackets and 24 screws 3. 2 x Power cord

2

3

4

5

4. Console cable--RJ-45 to D-Sub
5. Documentation--Quick Start Guide (this document) and Safety and Regulatory Information

Overview

1

2

1

46

10

11

10

8

5

3

7

9

1. 64 x SFP GPON ports 2. 2 x QSFP28 40G/100G ports 3. 8 x SFP28 10G/25G ports 4. System LEDs 5. 1 x SFP Management port 6. 1 x 1PPS

7. 1 x RJ45 Management port 8. 1 x RJ45 Console port 9. 1 x USB port 10. 2 x AC PSUs 11. 4 x Fan trays

System LEDs

Port LEDs

UID LED: Blinking blue FAN LED: Off (OK), Red (fault) Air Filter LED: Off (OK), Red (change filter) PSU LEDs: Green (OK), Red (fault) Alarm LED: Green (OK), Blue (minor), Red (major) State LED: Green (OK), Blue (initializing), Red (fault) 1PPS LED: Green (OK)

FRU Replacement

PSU Replacement 1. Remove the power cord.
2. Press the release latch and remove the PSU.
3. Install replacement PSU with matching airflow direction.

Fan Tray Replacement 1. Loosen the fan tray screw.
2. Remove fan tray from the chassis.
3. Install replacement fan with matching airflow direction.

SFP GPON Port LEDs: Green (link up and in service), Blue (disable), Red (fault), Blinking (activity) QSFP28 Port LEDs: Green (100G), Blue (40G), Orange (4G), Blinking (activity) SFP28 Port LEDs: Green (25G), Blue (10G), Orange (1G), Blinking (activity)

Airflow Reversal

1. F2B Airflow Remove front-to-back (F2B) airflow fan trays (red handles) and PSUs (red release latches).

2. B2F Airflow Install back-to-front (B2F) airflow fan trays (blue handles) and PSUs (blue release latches).

*150200002424A_R01*

­ 1 ­

E082021-MR-R01 150200002424A

Installation

Quick Start Guide

Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty. Avertissement: Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec l'appareil. L'utilisation d'autres accessoires et vis pourrait endommager l'appareil. Les dommages causés par l'utilisation d'accessoires non approuvés ne sont pas couverts par la garantie.
Caution: The device includes plug-in power supplies (PSUs) and fan tray modules that are installed into its chassis. Make sure all installed modules have a matching airflow direction. Attention: Le appareil comprend des modules d'alimentation et de modules de ventilation installés dans son châssis. Assurez-vous que tous les modules installés ont une direction d'air adaptée.
Note: The device has the Open Network Install Environment (ONIE) software installer preloaded on the switch, but no switch software image. Information about compatible switch software can be found at www.edge-core.com. Note: Model name and approval markings are indicated on the product label located on the bottom of the device.
1 Mount the Device

3 Connect Power
AC or DC Power Connect the two AC or DC PSUs to a power source.
Caution: Use a UL/IEC/EN 60950-1 certified power supply to connect to a DC converter, and a #14 AWG (for -36 ­ -72 VDC PSU). Attention: Utilisez une alimentation certifiée UL/IEC/EN 60950-1 pour le connecter à un convertisseur CC et un câble AWG #14 (pour -36 ­ -72 VDC) pour vous connecter à une alimentation CC.

1. Attach the Brackets Use the included screws to attach the left and right brackets. 2. Mount the Device Mount the device in the rack and secure it with rack screws.
2 Ground the Device

1 2
3
1. Connect the RTN return. (red wire). 2. Connect the -36 ­ -72 VDC (black wire). 3. Connect the Chassis Ground (yellow-green wire).
Note: DC terminal screws should be tightened to a torque of 6.6 in-lbs.
4 Verify Device Power
Check the PSU LEDs The PSU1/PSU2 LEDs should be on green when operating normally.
5 Make Network Connections

Ensure the Rack is Grounded Ensure the rack on which the device is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment).
Ground the Device Attach a #14 AWG grounding wire (not included) to the grounding point on the device rear panel. Then connect the other end of the wire to rack ground.

1. SFP GPON slots First install GPON transceivers and then connect fiber optic cabling to the transceiver ports.

­ 2 ­

Quick Start Guide

2. QSFP28 slots First install QSFP28 transceivers and then connect fiber optic cabling to the transceiver ports.
3. SFP28 slots First install SFP28 transceivers and then connect fiber optic cabling to the transceiver ports.
6 Connect the Timing Port
1PPS port Use a coax cable to connect the 1-pulse-per-second (1PPS) SMB port to another synchronized device.
7 Make Management Connections

Hardware Specifications

Chassis

Size (WxDxH) 477 x 600 x 89 mm (18.78 x 23.62 x 3.50 in)

Weight

16.51 kg (36.40 lbs)

Temperature Operating: 0° C to 40° C (32° F to 104° F) Storage: -40° C to 70° C (-40° F to 158° F)

Humidity

Operating: 5% to 95% (non-condensing)

System Input Rating

AC Input

100-240 Vac, 50-60 Hz, 5.5-2.3 A

DC Input

-36 ­ -72 Vdc, 16-8 A

Power

480 W

Consumption

Regulatory Compliances

Emissions

EN 55032:2015+AC:2016, Class A EN 61000-3-2:2014, Class A EN 61000-3-3:2013 FCC Class A

Immunity

IEC 61000-4-2/3/4/5/6/8/11 EN 55024:2010+A1:2015 EN 55035:2017

Safety

UL (UL 62368-1 & CSA C22.2 No. 62368-14 CB (IEC/EN 60950-1, IEC/EN 62368-1)

1. SFP/RJ-45 slots Combo RJ-45/SFP Ethernet out-of-band (OOB) management port to provide a network management connection.
2. RJ-45 Console port Connect the included console cable and then configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.
3. USB port Connect using a standard USB cable to a storage device.

­ 3 ­


64  GPON vOLT
ASGvOLT64



www.edge-core.com

1
1. ASGvOLT64 2.  --2  24  3. 2 x 

1

2

1

3
1. 64 x SFP GPON  2. 2 x QSFP28 40G/100G  3. 8 x SFP28 10G/25G  4.  LED 5. 1 x SFP  6. 1 x 1PPS
 LED

2

3

4

5

4. Ñ RJ45  D-Sub 5. Ñ 



46

10

11

10

8

5

7

9

7. 1 x RJ45  8. 1 x RJ45  9. 1 x USB 
10. 2 x AC PSU 11. 4 x 

 LED

UID LEDj  LEDj (  )e (  )  LEDj (  )e (  ) PSU LEDj (  )e (  )  LEDj (  )e (  )e (  )  LEDj (  )e (  )e (  ) 1PPS LEDj (  )
 FRU

 PSU 1. f 2.  PSUf
3.  PSUf

 1. f
2. f
3.  f

SFP GPON  LEDj (  )e (  )e  (  )e (  ) QSFP28  LEDj (100G)e (40G)e (4G)e (  ) SFP28  LEDj (25G)e (10G)e (1G)e (  )



1.F2B   (F2B)    PSU  f

2.B2F   (B2F)   PSU  f

*150200002424A_R01*

­ 4 ­

E082021-MR-R01 150200002424A



jd ff df

3 

j (PSU) ff
j (ONIE) df dj www.edgecore.comf j f



1 

AC  DC   AC  DC PSU f
j UL/IEC/EN 60950-1   DC d #14 AWG (  -36 ­ -72 VDC PSU)f

1.  f
2.  f
2 

1 2 3
1.  RTN f(  )f 2.  -36 ­ -72 VDC (  )f 3.  (  )f
jDC  6.6 in-lbs f

 d ETSI ETS 300 253f  f
  #14 AWG  f df

4 
 PSU LEDs dPSU1  PSU2 LED f
5 

1.SFP GPON   GPON df
­ 5 ­

2.QSFP28   QSFP28 df
3.SFP28   SFP28 df
6 
1PPS   1  (1PPS) SMB  f
7 







 x  477 x 600 x 89 mm (18.78 x 23.62 x 3.50 in) x 



16.51  (36.40  )



j0° C  40° C 32° F  104° F j-40° C  70° C -40° F  158° F



j5%  95% 



AC 

100-240 Vace50-60 Hze5.5-2.3 A

DC 

-36 ­ -72 Vdce16-8 A



480 W

 

EN 55032:2015+AC:2016, Class A EN 61000-3-2:2014, Class A EN 61000-3-3:2013 FCC Class A



IEC 61000-4-2/3/4/5/6/8/11 EN 55024:2010+A1:2015 EN 55035:2017



UL (UL 62368-1 & CSA C22.2 No. 62368-14 CB (IEC/EN 60950-1, IEC/EN 62368-1)

1.SFP/RJ-45   RJ-45/SFP  (OOB) f
2.RJ-45  dj115200 bpse8 e  e1 e8 d f
3.USB   USB f

­ 6 ­


Acrobat Distiller 11.0 (Windows)