Installation Guide for Acrel models including: AWT100 Data Conversion Module, AWT100, Data Conversion Module, Conversion Module, AWT100 Conversion Module, Module

admin


File Info : application/pdf, 21 Pages, 503.86KB

PDF preview unavailable. Download the PDF instead.

K1189010778
329
AWT100 Data Conversion Module Installation Manual V1.2
Acrel Co., Ltd.
1

DECLARATION
All rights reserved. Without the written permission of the company, the contents of any paragraphs and chapters in this manual shall not be excerpted, copied or copied or disseminated in any form, otherwise all consequences shall be borne by the offender.
The company reserves the right to modify the product specifications described in the manual without notice. Before placing an order, please consult your local agent for the new specifications of this product.

Contents
1 Overview................................................................................................................................................ 1 2 Product Model........................................................................................................................................ 2 3 Features.................................................................................................................................................. 2 4 Typical Applications.............................................................................................................................. 3 5 Technical Parameters..............................................................................................................................3 6 Installation and wiring instructions........................................................................................................ 5
6.1 Outline and installation dimensions................................................................................................ 5 6.2 Product installation Adopt standard DIN35mm rail type installation.............................................6 6.3 Terminals and wiring...................................................................................................................... 6
6.3.1 AWT100-2G/NB/4G/LoRa/LW/GPS/WiFi terminal and wiring............................................. 6 6.3.2 AWT100-CE terminal and wiring............................................................................................. 6 6.3.3 AWT100-DP terminal and wiring............................................................................................. 6 6.3.4 AWT100-2G/NB/4G/LoRa/LW/GPS/WiFi/CE/DP side interface definition........................... 7 6.4 Panel light definition....................................................................................................................8 6.4.1 Definition of AWT100-2G/NB/4G wireless communication terminal panel lights................. 8 6.4.2 Definition of AWT100-LoRa wireless communication terminal panel light........................... 8 6.4.3 AWT100-LW Definition of wireless communication terminal panel lights............................. 9 6.4.4 AWT100-GPS Definition of wireless communication terminal panel lights............................9 6.4.5 AWT100-WiFi Definition of wireless communication terminal panel lights........................... 9 6.4.6 AWT100-CE Ethernet communication panel light definition.................................................. 9 6.4.7 AWT100-DP data conversion module panel light definition................................................... 9 6.4.8 AWT100-POW Panel light definition of power module...........................................................9 7 AWT100 Wireless Communication Terminal User Guide..................................................................... 9 7.1 AWT100 wireless communication terminal configuration............................................................. 9 7.2 AWT100 wireless communication terminal parameter description..............................................11 8 How to use............................................................................................................................................17

1 Overview
At present, wireless technology relies on the advantages of easy deployment, low construction cost, and wide application environment. Data diversification has gradually become an important direction for network development and application in the future industrial Internet. AWT100 data conversion module is a new data conversion DTU launched by Acrel Electric. Communication data conversion includes 2G, 4G, NB, LoRa, LoRaWAN, GPS, WiFi, CE, DP and other communication methods. The downlink interface provides a standard RS485 data interface. It can be easily connected to power meters, RTUs, PLCs, industrial computers and other equipment, and only needs to complete the initial configuration at a time to complete the data collection of the MODBUS equipment; at the same time, the AWT100 series of wireless communication terminals use powerful micro-processing chips to cooperate Built-in watchdog technology, reliable and stable performance.
The appearance is shown in Figure 1.
Figure 1 AWT100 Wireless communication terminal Features:
Using single-mode guide rail shape, small size, flexible and convenient installation; A variety of mainstream wireless modules, suitable for various on-site environments; Multiple hardware interface modes, easy to use with other products; Rich communication interface protocols can meet the different needs of customers. The applicable industries are as follows: Wireless meter reading; Building automation and security; Robot control; Power distribution network monitoring, power load monitoring;  Intelligent lighting control; Automatic data collection; Industrial remote control and telemetry; Highway and railway data transmission; Other power and industrial control industries, etc.
1

2 Product Model
AWT100-

2G-2G communication terminal

4G-4G communication terminal

2LGoR2aG-LoRacommunication te4rGmi4naGl LW:LoRaWAN Communication Terminal

LNoBR-aNBL-oIROaTcommunication tLeWrmLinoaRl aWAGNPS:GPS positioning

NB NB-IoT GPS:GPS

WWiFIFiI:-WWiIFFIiWireless

CE:CE CE:CEEthernet Communication

DDPp::Prrooffibiubsucsommunication

Acrel DataConversion Module
3 Features
Support serial MODBUS RTU protocol data collection, and communicate with Acrel server through Acrel platform protocol. Support data collection of up to 30 MODBUS RTU devices. Support the collection of 5 register address fields for each MODBUS device, and the address range of each register does not exceed 64. Support to preset alarm address and alarm value to trigger alarm for each MODBUS address range. There are currently at most 5 alarm addresses in each address domain. Support server MODBUS or LoRa transparent transmission communication. Support fixed IP and dynamic domain name resolution methods to connect to the data center. Support transparent transmission protocol, general mode (active round copy, regular report), MQTT protocol, smart power wireless protocol, prepaid wireless protocol It can be customized and developed.  AWT100-LW wireless communication terminal can upload data to the server through LoRa communication.  AWT100-GPS wireless module can measure geographic location, obtain latitude and longitude and satellite time.  The AWT100-WiFi wireless module can automatically access the WIFI hotspot according to the hotspot name and password, realize the transparent transmission of 485 and WIFI data, and also use our cloud platform protocol.  AWT100-CE can realize data transmission from 485 to Ethernet. It can be used as a TCP client and supports transparent transmission or our cloud platform protocol.  AWT100-DP can realize data transmission from ProfiBus to MODBUS. Note: AWT100-2G/NB/4G wireless communication terminal can communicate with the Acrel server through the Acrel platform protocol.

2

4 Typical Applications
Typical application connections are shown in Figure 2 and Figure 3. Connect the on-site 485 devices to the AWT100 wireless communication terminal. The AWT100 wireless communication terminal will actively collect the data of the 485 device according to its own configuration, and then communicate with the Acrel server.

Acrel Sensor

AWT100-2G/NB/4 G

Cloud Server

AWT100-2G/NB/4G

Acrel Sensor

User PC

User Mobile

Figure 2 AWT100-2G/NB/4G Typical application of wireless communication terminal

Acrel Sensor Acrel Sensor

AWT100-LoRa

Internet

AWT100-LoRa AWT100-LoRa

Cloud Server

Acrel Sensor

AWT100-LoRa

Control Host

User PC

User Mobile

Figure 3 AWT100-LoRaTypical application of wireless communication terminal

5 Technical Parameters

Parameter Name

AWT100-4G

AWT100-NB

Working frequency

LTE-FDD B1 B3 B5 B8 LTE-TDD B34 B38 B39 B40 B41 CDMA B1 B5 B8 GSM 900/1800M

H-FDD B1 B3 B8 B5 B20
3

AWT100-2G
GSM 850 EGSM 900 DCS 1800 PCS 1900

AWT100-LoRa AWT100-LW
LoRa 460 510MHz

Transmission rate
Downlink Uplink SIM card voltage
Working current
Antenna interface Serial port type Baud rate Operating Voltage Operating temperature Storage temperature Humidity range

LTE-FDD Maximum downlink rate 150Mbps Maximum uplink rate 50Mbps LTE-TDD Maximum downlink rate130Mbps Maximum uplink rate 35Mbps CDMA Maximum downlink rate 3.1Mbps Maximum uplink rate 1.8Mbps GSM Maximum downlink rate 107Kbps Maximum uplink rate 85.6Kbps
4G Communication

Maximum downlink rate 25.2Kbps Maximum uplink rate 15.62Kbps

GPRS Maximum downlink rate 85.6kbps Maximum uplink rate 85.6kbps

RS485 Communication

NB-IoT Communication

2G Communication

LoRa 62.5kbps
LoRa Communication

3V1.8V

/

Static power1WTransient power consumption3W

Static power 0.5W
Transient power consumption1W

50/SMAFaucet

RS-485 4800bps9600bps19200bps38400bpsdefault 9600bps

DC24V  AC/DC220V

-1055

-4085 095% Non-condensing

Parameter Name
Working frequency Transmission rate
Downlink Uplink
Working current Antenna interface Serial port type
Baud rate Operating Voltage Operating temperature

AWT100-LoRa

AWT100-LW AWT100-LW868 AWT100-LW923 AWT100-LORAHW

460510MHz

470MHZ

863-870MHZ

920-928MHZ

860-935MHZ

LoRa 62.5kbps RS485 Communication LoRa Communication Static power0.5WTransient power consumption1W 50/SMAFaucet
RS-485 4800bps9600bps19200bps38400bpsdefault 9600bps
DC24V  AC/DC220V -1055

4

Storage temperature Humidity range

-4085 095% Non-condensing

parameter name
Work
Downlink Uplink
Working current
interface Serial port type
Baud rate Operating Voltage Operating temperature Storage temperature Humidity range

AWT100-GPS

AWT100-WiFi

AWT100-CE

AWT100-DP

Positioning accuracy: 2.5-5m

support 2.4G frequency band WiFi rate: 115200bps

Ethernet rate 10/100M Profibus address:

adaptive

1~125. (Note)

RS485 Communication

GPS positioning

WiFi wireless

Ethernet communication

Profibus communication

Static power

consumption

Static power consumption1Wtransient power consumption3W

0.5W transient power

consumption

1W

50/SMAFaucet

RJ45

DP9

RS-485 Communication

4800bps9600bps19200bps38400bpsDefault 9600bps

DC24V or AC/DC220V

-1055

-4085 095% Non-condensing

Note: AC/DC220V power supply requires external AWT100-POW power supply module. Profibus communication rate: 9.6kbps, 19.2kbps, 45.45kbps, 93.75kbps, 187.5kbps, 500kbps, 1.5Mbps, 3Mbps, 6Mbps, 12Mbps. Data exchange length: total input length<=224 bytes, total output length<=224 bytes. The number of downstream instruments connected: 1~80.
6 Installation and wiring instructions
6.1 Outline and installation dimensions

5

6.2 Product installation Adopt standard DIN35mm rail type installation.
6.3 Terminals and wiring 6.3.1 AWT100-2G/NB/4G/LoRa/LW/GPS/WiFi terminal and wiring

Auxiliary powerDC24V

RS485 Communication

The function of the network port is the power interface and the RS485 interface. The specific definitions are as follows:

1

2

POWER

DC12V

3

4

GND

5

6

7

8

TX RX 485A 485B

6.3.2 AWT100-CE terminal and wiring

Auxiliary power RS485 Communication
Ethernet communication 6.3.3 AWT100-DP terminal and wiring
Auxiliary power RS485 Communication

6



6.3.4 AWT100-2G/NB/4G/LoRa/LW/GPS/WiFi/CE/DP side interface definition
1 2 34 5 10 9 8 7 6

12 3

4 56 7

8 9 10

NC +5V GND 485A NC 485B GND +5V NC

Note: The two interfaces of network port and terminal can only be used by one of the two (except for AWT100-CE), and cannot be used at the same time.
Power module terminal definition

Auxiliary powerAC/DC 220V

Side interface definition
1 2 34 5 10 9 8 7 6

1 2 3 4 5 6 7 8 9 10 NC GND +5V NC +5V GND NC
The side interface is used for the AWT100 wireless communication terminal to supply power through the AWT100-POW power module AC220V. The AWT100 wireless communication terminal is connected to the AWT100-POW power supply module through pins and fixed together by a buckle. The connection diagram is shown in Figure 4:

7

Installation Notes:

Figure 4

When the AWT100 wireless communication terminal is powered by the AWT100-POW power

supply module, the auxiliary power terminal and network port of the AWT100 wireless

communication terminal The 24V power supply cannot be connected again.

 Antenna installation, the antenna interface of the AWT100 wireless communication terminal adopts

50/SMA (female), and the external antenna must be an antenna suitable for the working band. If

other unmatched antennas are used, it may affect or even damage the equipment.

When installing the SIM card, make sure that the device is not powered on. The SIM card of the

AWT100 wireless communication terminal adopts a card tray installation method. You need to put the

SIM card in the card tray correctly, and then insert the SIM card into the card holder of the device.

6.4 Panel light definition

6.4.1 Definition of AWT100-2G/NB/4G wireless communication terminal panel lights

LINK Green

RSSIRed

COMMOrange

The green indicator flashes for 2 The red indicator flashes The orange indicator

seconds, the wireless module is being for 3 seconds to indicate flashes to indicate that

initialized

that the signal is less than there is network data

The green indicator flashes for 1 20%

communication

second, connecting to the server

The green indicator light is always on

to indicate that the server is connected

and the signal strength is greater than

20%

6.4.2 Definition of AWT100-LoRa wireless communication terminal panel light

RUNGreen

LoRaRed

COMMOrange

The green indicator light is The red indicator light flashes The orange indicator light

always on, indicating that the for 1 second when there is a flashes for 1 second when

meter has been able to operate LoRa signal to receive and send there is 485 to receive and

normally.

data.

send data.

8

6.4.3 AWT100-LW Definition of wireless communication terminal panel lights

RUNGreen

LoRaRed

COMMOrange

The green indicator flashes for 1 The red indicator flashes for 1 The orange indicator flashes second and the gateway is second when there is LoRa for 1 second when there is 485
signal to receive and send data. to receive and send data. connecting.

The green indicator light is

always on to indicate that the

gateway has been connected

6.4.4 AWT100-GPS Definition of wireless communication terminal panel lights

RUN Green

LoRaRed

The green indicator light is always on, After the positioning is successful, it flashes for indicating that the power supply voltage 1 second and the green indicator light is off is normal.

6.4.5 AWT100-WiFi Definition of wireless communication terminal panel lights

RUNGreen

LoRaRed

Blinking in connection, the connection Blinking when there is data transmission is successful.

6.4.6 AWT100-CE Ethernet communication panel light definition RJ45: Ethernet interface 6.4.7 AWT100-DP data conversion module panel light definition Digital tube: display Profibus address (1~99) USB interface: configure the module parameters, connect to the upper computer DB9 interface: communicate with upstream DP equipment, Profibus_DP protocol 485 interface: communication with downstream instruments, Modbus_Rtu protocol 6.4.8 AWT100-POW Panel light definition of power module The green indicator light is always on to indicate that the power module is operating normally. If the indicator light is off, it indicates that the module is not powered on or is faulty.
7 AWT100 Wireless Communication Terminal User Guide
7.1 AWT100 wireless communication terminal configuration Before using the AWT100 wireless communication terminal, the user can configure the parameters
of the AWT100 wireless communication terminal according to the actual situation. The operation process is as follows: (1) The AWT100 wireless communication terminal is powered on, and the working indicator of the AWT100 wireless communication terminal flashes, indicating that the AWT100 wireless communication terminal has started to work. (2)Start the configuration software of the AWT100 wireless communication terminal, which consists
9

of the computer serial port parameter area, information display area, parameter setting area, parameter reading and setting buttons, as shown in Figure 5.
Computer serial port parameter area
Information display area

Parameter setting area

Figure 5 The AWT100 wireless communication terminal configuration software can read and set parameters, and can test the working status of the AWT100 wireless communication terminal. Please confirm the serial port number of the currently used serial port, modify the serial port number, and keep the serial port baud rate consistent, and click "open serial port" after confirmation. After the serial port is

successfully connected to the host computer (the host status box turns green)



(3)AWT100-2G/4G/NB wireless communication terminal parameter reading

Click the in the upper right corner

 to display all the parameter values inside the

AWT100 wireless communication terminal, as shown in Figure 5. (4)AWT100-2G/4G/NB wireless communication terminal parameter setting
Click the parameter value to be modified, directly input or modify the corresponding parameter

valueClick the button in the upper right corner

to complete the parameter setting.

7.2 AWT100 wireless communication terminal parameter description (1) AWT100-2G/4G/NB wireless communication terminal connection status

 GPRS status Display the connection status between the AWT100-2G/4G/NB wireless communication terminal
10

and the server.  Signal value
Indicates the signal strength of the connection between the AWT100-2G/4G/NB wireless communication terminal and the server. The larger the value, the stronger the signal.  Number of upload packages
Indicates the number of data packets uploaded by the AWT100-2G/4G/NB wireless communication terminal to the server.  Number of download packages
Indicates the number of data packets received from the server by the AWT100-2G/4G/NB wireless communication terminal.  SIM card number
Insert the SIM card number of the AWT100-2G/4G/NB wireless communication terminal.  IMEI
The device identification code of the AWT100-2G/4G/NB wireless communication terminal. (2) AWT100 wireless communication terminal software information

 version Software version of AWT100 wireless communication terminal
 serial number Software version of AWT100 wireless communication terminal
 TCP port_1 status Green indicates that the AWT100-2G/4G/NB wireless communication terminal is successfully
connected to the server port .Red indicates that the AWT100-2G/4G/NB wireless communication terminal failed to connect to the server port.  TCP port_2 status
TCP port_2 is currently not used  Time
The system time of the current computer.  Equipment time

Equipment time of wireless communication terminal AWT100-2G/4G/NB,Click

the device

time of the AWT100-2G/4G/NB wireless communication terminal can be synchronized with the current computer system time.
11

 Data area

The first box in the data area indicates the starting MODBUS address of the register of the

downstream device, and the second box indicates the meter reading length (not more than 64), for

example

 indicates to start meter reading from the downstream device address

1000H, the address length is 2a (hexadecimal).

Parameter area

The parameter area can be selected from the drop-down . The data in the parameter area can be

uploaded to the server once when the device is powered on, once a day, or when the data changes.

 Alarm word

setting 10 alarm words of addresses can be set, and data will be uploaded when the alarm word of the

set address changes.

 Number of equipment

The number of meter readings is set, and the data collection of up to 30 MODBUS RTU devices is

supported.

 Number of meter reading segments

The number of register address fields collected by each MODBUS device shall not exceed 5.

 Number of alarm segments

The total number of alarm words to be set is up to 10, and the number of settings should be

consistent with the number of alarm words.

 Waiting time

Wait for the response time of the downstream device.

 Number of timeouts

If the number of reconnections of the downlink device exceeds the specified number, it is considered

that the downlink device is disconnected from the AWT100 wireless communication terminal.

 Downlink

The default 485 bus communication (LoRa communication is optional).

 Downstream device address type

Use the MODBUS address to read the meter and the serial number (14-digit) address to read the

meter.

 Downstream equipment type (Reserved) (4) AWT100-2G/4G/NB wireless communication terminal

network setting parameters
12

 IP_1 address The IP address of the first server to connect to.
 IP_1 port Connect the IP port of the first server.
 IP_2 address Connect to the IP address of the second server.
 IP_2 port Connect the IP port of the second server.
 Domain name setting_1 The domain name of the first server to connect to.
 Domain name setting_2 The domain name of the second server to connect to.
 Device number Device serial number (14 digits).
 Data upload interval The data upload time interval in the data area, the default is 5min.
 Parameter upload interval The data upload time interval in the data area, the default is 1440min.
 Connection method The connection address method with the service area (IP/domain name).
 Total number of TCP connections The number of servers connected at the same time.
 Network timeout The time to wait for a response from the server.
 Number of network timeout retries The number of retransmissions to the server.
(5) AWT100-2G/4G/NB wireless communication terminal protocol setting parameters
13

 Coding factor 1  Coding factor 2  Code classification  Process coding  ST  MN  Communication protocol options  Protocol internal options The above are the relevant agreement parameters involved in each area of the HJ212 environmental protection agreement, which depends on the agreement. (6) Downlink device status of AWT100-2G/4G/NB wireless communication terminal

 Downlink device status

Click

can read the status of all downstream devices .Click

can read the status of a single

downstream device.Click can write the serial number of the downstream device (when using the
MODBUS address to read the meter,there is no need to write the serial number).Red indicates that the downstream device is offline.Green indicates that the downstream device is online .E.g

.Indicates that the device with the serial number 20190903000001 is
online. (7) AWT100-LoRa Wireless communication terminal relay/transmission parameters
Relay/transparent transmission setting options are used to set the wireless parameter settings of the

AWT100-LoRa wireless communication terminal  Click

the button can read the wireless

parameter settings of the AWT100-LoRa wireless communication terminal. After modifying the

wireless parameters of the AWT100-LoRa wireless communication terminal Click complete parameter setting

the button to

14

 Relay transmission frequency The frequency of relay transmission: 460  510MHz.If the working mode of the AWT100-LoRa
wireless communication terminal is set to relay mode, the relay transmission frequency must be inconsistent with the transparent transmission frequency.  Transparent transmission frequency
The frequency of transparent transmission: 460510MHz.  Expansion factor
LoRa spreading factor  Signal bandwidth
LoRa signal bandwidth  Type
Set the working mode of the AWT100-LoRa wireless communication terminal.There are two ways to choose from: transparent transmission and relay.
(8) AWT100-GPS positioning module parameter settings

Positioning interval: latitude and longitude refresh interval.

Positioning time: positioning satellite time.

AWT_GPS modbus register address table and description

Adress

Register number

name

Number of Attributes(W

registers

/R)

Description

0000H

1

contact address

1

W/R Value range 1~127, universal address 0

0001H

2

Baud rate

1

W/R

0:1200 1:2400 2:4800 3:9600 4:19200 5:38400 6:57600 7:115200

0002H

3

Positionin g interval

1

W/R

Value range 100ms~10000ms

Latitude

ASCIICode

0003H

4

hemispher

1

e

R

(0x4E)N,Northern Hemisphere

(0x53)SSouthern Hemisphere

0004H

5

0005H

6

latitude

2

R

E.g 3150.7797 -> 31°50.7797

0006H

7

Transhemi sphere

1

0007H

8

0008H

9

longitude

2

ASCII Code

R

(0x45)E,Eastern Hemisphere

(0x57)WWestern Hemisphere

R

float E.g 11711.9287 -> 117°11.9286

0009H

10

000AH

11

Second Minute Hour
Day

1

R

1

R

15

UTC time

000BH

12

Month Year

1

R

[Note] 1. Modbus read and write reply delay is 300ms~500ms under the default baud rate of 9600,

Therefore, the waiting time of Modbus host should be at least more than 300ms;

(9)AWT100-WiFiWireless communication module parameter setting

AP: WIFI hotspot name PASS: WIFI hotspot password (10)AWT100-CEEthernet data conversion module parameter setting

(11)AWT100-DP data conversion module parameter setting

16

8 How to use
After setting the parameters of the AWT100 wireless communication terminal, confirm that the downlink equipment is operating normally and the gateway can communicate with the AWT100 wireless communication terminal normally. Wait for the AWT100 wireless communication terminal to establish a connection with the server, and send the device number to the server to distinguish the devices. At the same time, the AWT100 wireless communication terminal will poll the downstream device to query the online downstream device according to the set query address range and query register address field, and send the polled data to the server for reporting.
17

Headquarters: Acrel Co., LTD. Address: No.253 Yulv Road Jiading District, ShanghaiChina TEL.: 0086-21-69158338 0086-21-69156052 0086-21-59156392 Fax: 0086-21-69158303 Web-site: www.acrel-electric.com E-mail: ACREL008@vip.163.com Postcode: 201801

0086-21-69156971

Manufacturer: Jiangsu Acrel Electrical Manufacturing Co., LTD. Address: No.5 Dongmeng Road,Dongmeng industrial Park, Nanzha Street,Jiangyin City,Jiangsu Province,China TEL./Fax: 0086-510-86179970 Web-site: www.jsacrel.com Postcode: 214405 E-mail: JY-ACREL001@vip.163.com



References