User Manual for ROBE models including: LEDBeam 350 Lighting, LEDBeam 350, Lighting

User Manual

Robe LEDBeam 350 | Artistic Solutions


File Info : application/pdf, 39 Pages, 5.98MB

PDF preview unavailable. Download the PDF instead.

User manual Robin LEDBeam 350 RGBA FW EP FWEP
QR code for user manual
Version 2.0 1

ROBIN LEDBeam 350 RGBA ROBIN LEDBeam 350 FW RGBA ROBIN LEDBeam 350 RGBA EP ROBIN LEDBeam 350 FW RGBA EP
Table of contents
1. Safety instructions ......................................................................................................... 3 2. Fixture exterior view ...................................................................................................... 5 3. Installation....................................................................................................................... 6
3.1 Connection to the mains ............................................................................................ 6 3.2 Rigging the fixture ...................................................................................................... 7 3.3 Eggcrate installation................................................................................................... 9 3.4 Diffusion filter installation (LEDBeam 350 only) ...................................................... 10 3.5 DMX-512 connection................................................................................................ 11 3.6 Ethernet connection (EP version only) ..................................................................... 12 3.7. Wireless DMX operation ......................................................................................... 13 4. Control menu map........................................................................................................ 14 5. Control menu ............................................................................................................... 17 5.1 Addressing (DMXA).................................................................................................. 17 5.2 Fixture information (Info) .......................................................................................... 17 5.3 Personality (Pers)..................................................................................................... 18 5.4 Manual Control (Manual).......................................................................................... 20 5.5 Test program (Test Prg)............................................................................................ 20 5.6 Stand-alone (St Alone) ............................................................................................. 20 5.7 Reset........................................................................................................................ 21 5.8 Special functions (Special)....................................................................................... 21 6. RDM ............................................................................................................................... 23 7. Error and information messages ................................................................................ 24 8. Technical Specifications.............................................................................................. 25 9. Maintenance and cleaning........................................................................................... 27 9.1 Replacing fuse ......................................................................................................... 27 10. Photometric diagrams................................................................................................ 28 11. ChangeLog ................................................................................................................. 32
2

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ROBIN LEDBeam 350 !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
Please consider that damages caused by manual modifications to the device are not subject to warranty.
The ROBIN LEDBeam 350 was designed for indoor use and it is intended for professional application only. It is not for household use.
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the rear panel of the fixture. This fixture should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the fixture from AC power before cleaning, removing or installing any part of the fixture.
The power plug has to be accessible after installing the fixture. Do not overload wall outlets and extension cords as this can result in fire or electric shock.
Do not allow anything to rest on the power cord. Do not locate this fixture where the cord may be damaged by persons walking on it.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the power cord from time to time.
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection.
Do not connect this fixture to a dimmer pack.
Warning! Risk Group 2 LED product according to EN 62471. LED light emission. Risk of eye injury. Do not look into the beam at short distance of
the of the product. Do not view the light output with optical instruments or any device that may
conncentrate the beam. The light source contains blue LEDs.
If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
Avoid brute force when installing or operating the fixture.
3

This fixture was designed for indoor use only, do not expose this unit to rain or use near water. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat, moisture or dust.
Do not block the lens array with any object when the fixture is under operation.
The cooling openings in head and base of the fixture should never be covered with cloth or other materials, and never must be blocked. This fixture should not be placed in a built-in installation unless proper ventilation is provided. Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened. Always use a secondary safety wire for overhead installation of the fixture. Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture. The fixture becomes hot during operation. Allow the fixture to cool approximately 15 minutes prior to manipulate with it. Operate the fixture only after having familiarized with its functions. Do not permit operation by persons not qualified for operating the fixture. Most damages are the result of unprofessional operation! Please use the original packaging if the fixture is to be transported. Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons! If this device will be operated in any way different to the one described in this manual, the product may suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. Immunity of the equipment is designed for electromagnetic environments E1, E2, E3 according to the standard EN55103-2 ed.2 Electromagnetic compatibility. Product family standard for audio, video, audiovisual and entertainment lighting control apparatus for professional use. Part 2: Immunity. The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. The installation company should check levels of possible interferences above the tested levels E1,E2,E3 given by this standard (e.g. transmitters in surrounding area) before installing the equipment. Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment ­ Emission Requirements according to class B.
Potential foggy front lens array does not influence function of the fixture and does not subject to complaint.
To avoid damage of an internal optical system of the fixture, never let the sunlight (or other light source) lights directly to the lens array, even when the fixture is not working
Potential colour non-uniformity of the front lens array may occur, it does not influence colour output from the fixture and is not considered a fault.
4

2. Fixture exterior view
1 - Lens array 2 - Arm 3 - Display 4 - Escape button 5 - Enter button 6 - Next button 7 - Preview button 8 - Base 9 - Tilt lock
10 - Top head cover 11 - Rear Head cover 12 - Handle 13 - DMX Out (5-pin XLR) 14 - DMX In (5-pin XLR) 15 - Fuse holder 16 - Power In (PowerCon True 1) 17 - Power Out (PowerCon True 1)
EP version only 18 - Ethernet In 19 - Ethernet Out
5

3. Installation
Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

3.1 Connection to the mains
For protection from electric shock, the fixture must be earthed!
The ROBIN LEDBeam 350 is equipped with auto-switching power supply that automatically adjusts to any 5060Hz AC power source from 100-240 Volts.
If you need to install a power plug on the power cable to allow connection to power outlets, install a grounding-type (earthed) plug following the plug manufacturer's instructions. If you have any doubts about proper installation, consult a qualified electrician.

Core (EU) Brown Light blue Yellow/Green

Core (US) Black White Green

Connection Plug Terminal Marking

Live

L

Neutral

N

Earth

The device falls under class one and must be earthed (grounded)!

Design of the ROBIN LEDBeam 350 allows to connect several fixtures to AC mains power in one interconnected daisy chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter "Technical specifications " The fixture head has to be locked for transportation - the tilt lock latch (9) has to be in locked position. To unlock the head, move the latch to unlock position before operating the fixture.

The max. number of connected fixtures depends on the AC mains power voltage:

CE:

US:

7 fixtures at power supply= 230V

6 fixtures at power supply= 230V

7 fixtures at power supply= 208V

5 fixtures at power supply= 208V

4 fixtures at power supply= 120V

3 fixtures at power supply= 120V

Real numbers of fixtures may differ from values stated above as you have to take into account the length of

supply cables, circuit breaker etc. at projecting of the fixtures installation Do not overload the supply line and

connecting leads.

Wiring and connection work must be carried out by qualified staff!

6

3.2 Rigging the fixture
The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges, under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled person once a year.
The fixture should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to) calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the projector. If you lack these qualifications, do not attempt the installation yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury or damage to property. The fixture has to be installed out of the reach of people.
If the fixture shall be lowered from the ceiling or high joists, professional trussing systems have to be used. The fixture must never be fixed swinging freely in the room.
Caution: Fixture may cause severe injuries when crashing down! If you have doubts concerning the safety of a possible installation, do not install the moving head!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the fixture's weight.

When installing the device, make sure there is no highly inflammable material (decoration articles, etc.) in a distance of min. 0.4 m.

.

CAUTION!

Use an appropriate clamp to rig the fixture on the truss.

Follow the instructions mentioned at the bottom of the base.

Make sure that the device is fixed properly! Ensure that the

structure (truss) to which you are attaching the fixtures is secure.

The fixture can be placed directly on the stage floor or rigged in any orientation on a truss without altering its operation characteristics . For securing the fixture to the truss, install a safety wire which can hold at least 10 times the weight of the fixture. Use only the safety wire with a snap hook with screw lock gate.

7

Truss installation
1-Quick-lock fastener 2-Omega holder 3-Trust 4-Clamp 5-Safety wire with a snap hooks
with screw lock gates 6-Attachment point
1. Bolt each clamp (1) to the omega holder (2) with M12 bolt and lock nut through the hole in the holder. 2. Fasten the omega holders to the bottom of the base by inserting both quick-lock fasteners (1) into
the holes of the base and tighten fully clockwise. 3. Clamp the fixture on a truss (3) and tighten the rigging clamps. 4. Pull a safety wire (5) through the carrying handle and the truss (3) as hown on the picture above in a suitable
position so that the maximum fall of the fixture will be 20 cm. Fasten a snap hook in the attachment point (6). Use only the safety wire with a snap hooks with screw lock gates.
When installing fixtures side-by-side, avoid illuminating one fixture with another!
8

3.3 Eggcrate installation
Disconnect the fixture from mains before installing the eggcrate .
1.Unscrew three screws M3x8 (1) which hold safety locks (2) of the lens array. Remove the safety locks (2). 2. Insert the eggcrate (3) on the lens array and screw it to the lens array by means of the three enclosed screws M3x10 (4). .
9

3.4 Diffusion filter installation (LEDBeam 350 only)
Disconnect the fixture from mains before installing the eggcrate .
1.Unscrew three screws M3x8 (1) which hold safety locks (2) of the lens array and remove them. 2.Unscrew the five screws M3x12 (3) with rubber rings (4) and remove the lens array (5) and the plastic film (6). 3. Remove transport protecting foil(s) from the diffusion filter. 4.Insert diffusion filter (7) matt side towards the lens array (5). 5.Insert the plastic film (6). 6.Insert the lens array (5) and screw it by means of the five screws (3) with rubber rings (4). IMPORTANT: Screws (5) have to be tightened in this way that rubber rings (4) are slightly deformed. Do not tighten them excessively, there is a risk of lens array cracking . 7.Insert the three safety locks (2) on the lens array (5) and screw them by means of the three screws M3x8 (1). 8.Check that all screws are screwed and tightened.
10

3.5 DMX-512 connection
The fixture is equipped with 5-pin XLR sockets for DMX input and output. Only use a shielded twisted-pair cable designed for RS-485 and 5-pin XLR-plugs and connectors in order to connect the controller with the fixture or one fixture with another.

DMX output XLR socket:

DMX input XLR plug:

1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Used for wireless DMX 5 - Used for wireless DMX

1 - Shield 2 - Signal (-) 3 - Signal (+) 4 - Used for wireless DMX 5 - Used for wireless DMX

If you are using the standard DMX controllers, you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter-cables.

Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always connect one output with the input of the next fixture until all fixtures are connected. Up to 32 fixtures can be interconnected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120  resistor between Signal (­) and Signal (+) into a 5-pin XLR-plug and plug it in the DMX-output of the last fixture.

11

3.6 Ethernet connection (EP version only)
The fixtures on a data link are connected to the Ethernet with appropriate communication protocol (e.g. ArtNet). The control software running on your PC (or light console) has to support this communication protocol. Art-Net communication protocol is a 10 Base T Ethernet protocol based on the TCP/IP.Its purpose is to allow transfer of large amounts of DMX 512 data over a wide area using standard network technology.

The IP address is the Internet protocol address.The IP uniquely identifies any node (fixture) on a network. The Universe is a single DMX 512 frame of 512 channels.

The Robin LEDBeam 350 EP is equipped with 8-pin RJ- 45 sockets for Ethernet connection.Use a network cable

category 5 (with four "twisted" wire pairs) and standard RJ-45 plugs in order to connect the fixture to the network.

RJ-45 socket (front view):

RJ-45 plug (front view):

1- TD+

5- Not connected

2- TD-

6- RX-

3- RX+

7- Not connected

4- Not connected

8- Not connected

Patch cables that connect fixtures to the hubs or LAN sockets are wired 1:1,that is,pins with the same numbers are connected together:
1-1 2-2 3-3 4-4 5-5 6-6 7-7 8-8 If only the fixture and the computer are to be interconnected,no hubs or other active components are needed.A cross-cable has to be used:
1-3 2-6 3-1 4-8 5-7 6-2 7-5 8-4

Connect the Ethernet inputs of all fixtures to Ethernet network. Set their IP addresses and Net Masks Correct communication protocol (e.g. "ArtNet") has to be selected from the menu "Eth Mode" in the fixtures (Pers-->Ethernet -->Eth Mode). Set Universe(s) according to communication protocol.

Example of connection:
(DMX address=177) IP addres=002.168.002.008 Universe=1

(DMX address=45) IP addres=002.168.002.004 Universe=1

(DMX address=23) IP addres=002.168.002.003 Universe=1

(DMX address=1) IP addres=002.168.002.002 Universe=1

An advised PC setting: IP address: 002.xxx.xxx.xxx (Different from fixtures IP addresses) NET mask: 255.0.0.0
The EP version of the fixture is equipped with Ethernet Pass Through Switch which sustains Ethernet integrity, when the fixture has no power, it automatically maintains network connectivity. If you use the Ethernet IN-OUT way for the Ethernet connection, max. 8 fixtures can be connected in the IN-OUT line.
12

3.7. Wireless DMX operation
The external ROBE Wireless CRMX Dongle allows receiving wireless DMX. This device is equipped with the Lumen Radio CRMX module and antenna for receiving DMX signal. CRMX module operates on the 2.4 GHz band.
ROBE Wireless CRMX Dongle
1 - 5-pin XLR (female) 2 - Locating pin 3 - Lock Push in the 5-pin XLR plug (1) into 5-pin XLR sockit (4) and simultaneously locating pin (2) into hole (5) in the fixture. In this way the wireless DMX module is connected with the fixture. NOTE: when you disconnect the DMX wireless module from fixture, press and hold lock (5) during getting the wireless module out. To link the fixture with DMX transmitter. The fixture can be only linked with the transmitter by running the link procedure at DMX transmitter . After linking , the level of DMX signal ( 0-100 %) is displayed in the menu item "Stat" (Special -->Vireless -->Stat). To unlink the fixture from DMX transmitter. The fixture can be unlinked from transmitter via the menu item " Unlink" (Special-->Vireless -->Unlink.).
13

4. Control menu map

Default settings=Bold print

Level 1

Level 2

Level 3

DMXA

Set DMXA DMX Pres
IP Addr*

001-512 Mode 1 Mode 2 Mode 3 Def addr Cus addr

Info Pers

Net Mask*
IP Addr* MAC Addr*
POn Time LOTi
Air fil DMX In Hea Temp Sw Ver
Ethernet*

N.M. 1 N.M. 2 N.M. 3 N.M. 4 Set Net M.
IP A. 1 IP A. 2 IP A. 3 IP A. 4 MAC A. 1 MAC A. 2 MAC A. 3 MAC A. 4 MAC A. 5 MAC A. 6 Total Reset
R LOTi G LOTi B LOTi A LOTi Aler P R Ti Pan : Dimm F Current Highest High Res IC-1 IC-2 IC-3 IC-4
Eth Mode

ArtNet sACN MANet

Level 4

Level 5

Apply IP 1 IP 2 IP 3 IP 4 Set Address 0-255 0-255 0-255 0-255

0-255 0-255 0-255 0-255

10-300 0-255 0-255

ArtNet sACN gMA I gMA II Uni Uni Uni
14

0-255 1-63999 1-256

Level 6

Level 7

Level 1
Manual Test Prg Sta Alone

Level 2
DMX Pres
Pan Rev Tilt Rev P/T Mode P/T Feed P movement range Display
BLC DMC BLC P/T Mic Sens Fans
Col Mix L Out M White P Dimmer C LED Freq LED Fadj Temp Uni I Ef Pos
Defaults

Level 3 MANet IGMP r Mode 1 Mode 2 Mode 3 On, Off On, Off Speed Time On, Off Standard Reduced Turn On/Off T Contrast Backlight On, Off On, Off 0...10...19 Fans Mode BLC Fans Noise L. RGBA, CMY H Int CRI On, Off Square, Linear Stand High -06,-05..00..05, 06 °C, °F Pan
: Dim F Store

Level 4 IsIDi Off, 1-10s
On, Off 0-100% 0-100%
Auto, High,Quiet 0-100%

Pan : Dimm F

0-255 0-255

Static Dynamic Music T Auto Run
Pr Play
Pr Edit

Pan Tilt Run
On, Off Off Test Prog 1 Prog 2 Prog 3 Test Prg Prog 1 Prog 2 Prog 3 Prog 1

0-255 0-255
Step 1
15

Level 5 1-32
Pan

Level 6

Level 7

Level 1

Level 2

Level 3 Prog 2 Prog 3

Level 4 : Step 40

Reset Special

RDM Low RDM Hight Wireless
Adjust

Stat Unlink DMX Val

Clalib

Pan : Dimm F
Cal Mech

Cal Col

Sw Upd

On, Off

* LEDBeam 350 RGBA EP version only

Cal Load

Level 5 : F.Tim S.Tim COPY Prg End
0-255
0-255
Pan C Tilt C Zoom C Store Red C Gre C Blu C Amb C Store

Level 6
0-25.5 0-25.5
1-40

Level 7

0-255 0-255 0-255
R X, R Y, R I, R T G X, G Y,G I, G T B X, B Y,B I, B T AX, A Y, AI, AT

16

5. Control menu
The ROBIN LEDBeam 350 is equipped with 2-row LCD display which allows to set the fixture´s behaviour according to your needs, obtain information on its operation, test its various parts and lastly program it, if it has to be used in a stand-alone mode.
Control panel: [ESCAPE] button used to leave the menu without saving changes. [NEXT] , [PREV] buttons for moving between menu items and for value adjusting. [ENTER] button used to enter the selected menu (menu item) and to confirm adjusted value. After switching the fixture on, display shows current DMX address.
5.1 Addressing (DMXA)
Set DMXA - Use this menu item to set the DMX start address of the fixture, which is defined as the first channel from which the ROBIN LEDBeam 350 will respond to the controller. If you set, for example, the address 23, the ROBIN LEDBeam 350 will use channels 23 - 44 for control (if Mode 1 is selected). Please, be sure that you do not have any overlapping channels in order to control each ROBIN LEDBeam 350 correctly and independently from any other fixture on the DMX data link. If there is no data received at the DMX input, the display will start to flash "0001" with actually stored DMX address.
DMX Pres - DMX preset. Use the menu to select desired channel mode. Mode 1 - 22 control channels Mode 2 - 16 control channels Mode 3 - 24 control channels
IP Addr* - IP address. Use the menu item to set desired IP address. IP address is the Internet protocol address. The IP uniquely identifies any node (fixture) on a network. There cannot be 2 fixtures with the same IP address on the network! Def addr - Default IP address. This address is derived from fixture´s MAC address and cannot be changed. Confirm the item "Apply" to select this address. Cus addr - Custom address. IP address consists of four decimal numbers, each ranging from 0 to 255, separated by dots, e.g. 2.16.254.1. Each part represents a group of 8 bits (octet) of the address. The following items "IP 1", " IP 2", " IP 3", " IP 4" allow you to set each part (number) of the address. After setting desired IP address, confirm the item "Set Address" to save this address.
Net Mask* - Network mask. Use the menu item to set desired network mask. A network mask is a 32-bit mask used to divide an IP address into subnets and specify the networks available hosts. The following items "N. M.1", "N.M.2", " N.M.3", " N.M.4" serve for setting of each part (number) of net mask. After setting desired network mask, confirm the item "Set Net M." to save adjusted values.
* LEDBeam 350 RGBA EP version only
5.2 Fixture information (Info)
IP Addr* - IP address. Select this menu item to read the IP address of the fixture. MAC Addr* -MAC address. Select this menu item to read the MAC address of the fixture. * LEDBeam 350 RGBA EP version only
POn Time - Power on time. Select the menu to read the number of fixture operation hours. Total - The item shows the total number of the operation hours since the ROBIN LEDBeam 350 has been fabricated.
17

Reset - The item shows the number of the operation hours that the ROBIN LEDBeam 350 has been powered on since the counter was last reset. In order to reset this counter to 0, press and hold both [NEXT] and [PREV] buttons and the [Enter] button at the same time.
LOTi - LEDs on time. Select the menu item to read the number of operation hours of individual LEDs (Red, Green, Blue, Amber).
Air fil - Air filter. Regular cleaning of the air filter in the fixture base is very important for the fixture´s life and performance. Bild-up of dust, dirt and fog fluid residues reduces the fixture´s fan ability. he two items of this menu help you to keep cleaning period of the air filter.
Alert P - Alert periode. Cleaning schedule for the fixture depends on the operating environment. It is therefore impossible to specify accurate cleaning interval. This item allows you to change the cleaning interval of the air filter. This "alert P" value is 300 hours and it is set as default. Inspect the fixture within its 300 hours of operation to see whether cleaning is necessary. If cleaning is required, clean air filter and change the value in this menu on acceptable level. Min. level of alert period is 10 hours, max. is 300 hours. R Ti - Remaining time. The item allows you to read the time which remains to cleaning air filter. The time period is set in the menu mentioned above. To reset this menu item press and hold both [NEXT] and [PREV] buttons and the [Enter] button at the same time.
DMX In - DMX readout. The menu is used to read DMX values of each channel received by the fixture.
Hea Temp - Head Temperature. The menu shows temperature on the LED module. Current - a current temperature of the LED module. Highest - a maximum temperature of the LED module since the fixture has been fabricated. High Res - a maximum temperature of the LED module since the counter was last reset. In order to reset this counter, press and hold both [NEXT] and [PREV] buttons and the [Enter] button at the same time.
Sw Ver - Software versions. Select this item to read the software version of the fixture modules. IC-1 - a pan/Tilt processor. IC-2 - a display processor. IC-3 - a LED control processor.
5.3 Personality (Pers)
Ethernet* - Ethernet setings. Use the menu item to select and set desired operating mode. Ethernet mode - use the menu to select a protocol. Artnet - fixture will receive Artnet protocol. sACN - fixture will receive sACN protocol. gMAI - fixture will receive MANet I protocol. gMAII - fixture will receive MANet 2 protocol.
ArtNet - the menu allows you to set parameter for ArtNet operation. Uni - selection of ArtNet Universe (0-255).
sACN - the menu allows you to set parameter for sACN operation. Uni - selection of sACN Universe (1-63999).
MANet - the menu allows you to set parameters for MANet operation. Uni - selection of MANet Universe (1-63999). sID - selection of the MANet I(II) session ID (1-32)
IGMP r - the menu allows you to set repeating time for Internet Group Management Protocol (Off, 1s-10s)
* LEDBeam 350 RGBA EP version only
DMX Pres - DMX preset. Use the menu to select desired channel mode. Mode 1 - 22 control channels
18

Mode 2 - 16 control channels Mode 3 - 24 control channels (default) Pan Rev - Pan reverse. The item allows to invert pan movement.
Tilt Rev - Tilt reverse. The item allows to invert tilt movement.
P/T Mode - Pan and Tilt movement mode. Use this menu to set mode of the pan/tilt movement. Speed - both Pan and tilt will move with the same speed as adjusted at the channel 5 "Pan/Tilt speed, Pan/Tilt time". Time ­ the pan and tilt will move with different speeds and they will come at the same time to the end point of their tracks (pan and tilt use their optimal speeds). Time of the pan/tilt movement (25.5 sec. max.) is set by the channel "Pan/Tilt speed, Pan/Tilt time".
P/T Feed - Pan and Tilt Feedback. The menu item allows to return the mowing head to the required pan/tilt position after changing the position by an external force if this option is set on. Note. The Pan/Tilt Feedback should be permanent On, the option Off is not suitable for standard operation and the head of the fixture can be damaged!
Pan range - Pan movement range. The menu item allows you to select desired pan movement range: Standard - pan movement range is 540° Reduced - pan movement range is 450°
Display - Display adjusting. This menu allows you to adjust the display behaviour. Turn - this function turns the display by 180°. On/Off T - this function allows you to keep the display permanent on or turn it off two minutes after last pressing any button on the control panel. Contrast- use this function to adjust contrast of the display (0-100%). Backlight- use this function to adjust backlight of the display (0-100%).
BLC DMC - Blackout during movement correction. Set this option on if you wish to close light output during the time when the head goes to its correct position, which has been changed by an external force.
BLC P/T - Active blackout. The menu item allows to close light output while the pan/tilt DMX values are changing.
C Mix M - Colour mixing mode. This item allows you to switch into RGBA or CMY mode. In the CMY mode, the ambwee(8bit)/amber (16) bit channels are not active.
L Out M - Light output mode. Use the menu to select desired light output mode. H Int - high intensity CRI - high CRI
White P - White Point 8000K. If the function is on, the CTC channel allows to set desired white in range of 8000K-2700K (0 DMX=8000K, 255 DMX=2700K). Necessary condition is , that RGBA channels have to be full or set at the same DMX values, e.g. 150. If this function is off, the range of whites is not uniform and may be different for each fixture.
Mic Sens - Microfon sensitivity. Enter the menu if you want to adjust the microphone sensitivity ( 0-max., 19-min.).
Fans - Fans setting. Use the menu to set behaviour of fixture fans. FansMode - the menu allows you to select desired power of fans: High - max. power of fans Auto - auto-control mode Quiet - If the options is selected, power of fans can be set in the menu "Noise L." BLC Fans - the menu item allows you to stop all fans in the fixture (option "On") when its light output is closed (shutter in range of 0-31 DMX or dimmer in 0 DMX). Noise L. - the menu item allows you to set speed of fans. At low speed of fans the light output may be reduced.
19

Dimmer C - Dimmer curve. Use the menu to select desired dimmer curve. Linear - a linear curve. Square - a square law curve.
LED Freq - LEDs frequency setup. The function allows you to set the PWM (Pulse Width Modulation) output frequency of LEDs to Standard or High. You can select from the following values:
300 Hz 600 Hz 1200 Hz 2400 Hz High
LED Fadj - LEDs frequency fine adjustment. The function allows you to change the selected PWM output frequency of LEDs in 6 levels up and down around the selected frequency in the menu "LED Freq".
-06...-01 - Frequence levels 1-6 under selected frequency. 00 - Selected frequency 01...06 - Frequence levels 1-6 above selected frequency.
Temp Uni - Temperature unit. Use the menu item to change temperature unit from °C to °F.
I Ef Pos - Init effect positions. Use the menu to set all effects to the desired positions at which they will stay after switching the fixture on without DMX signal connected.
Defaults - the menu item allows to set all fixture parameters to the default (factory) values.
5.4 Manual Control (Manual)
Use the menu to control all fixture channels by means of control buttons.
5.5 Test program (Test Prg)
Use this menu to to run a special demo-test sequences without an external controller, which will show you some possibilities of using ROBIN LEDBeam 350.
Static - Static mode. This mode is suitable for projections on the wall, ceiling or ground without any head movement. Dynamic - Dynamic mode. This mode uses all ROBIN LEDBeam 350 functions including pan/tilt movement and therefore is good for a complete introduction of the fixture.
5.6 Stand-alone (St Alone)
Music T - Music trigger. Select this function to enable the sound control of the running program via the built-in microphone.
Auto Run - Presetting playback. This function allows you to select the program which will be played in the stand-alone mode after switching the fixture on. Selected program will be played continuously in a loop.
Off - the option disables ,,Auto Run" function. Test - The option will start built-in test program. Prog 1 - the option will start user-created program 1 Prog 2 - the option will start user-created program 2 Prog 3 - the option will start user-created program 3
Pr Play - Playing program. Select this menu to run a user-created program in a loop. Test Prg - the option runs built-in test program. Prog 1 - the option runs user-created program 1 Prog 2 - the option runs user-created program 2 Prog 3 - the option runs user-created program 3
Select the program you wish and press [ENTER]. The selected program starts running. By Pressing [ENTER] again, program pauses running.
Pr Edit - Editing program. Select this menu to edit or create the program. The ROBIN LEDBeam 350 has one built-in program and one user-editable program up to 40 steps. Each program step has a step time - during
20

which effects last in the current step and a fade time- during which effects move to new positions.

To edit program:

Procedure:

1. Press [NEXT] or [PREV] to select the menu "Edit" and press [ENTER].

2. Press [NEXT] or [PREV] to select the desired program step and press [ENTER] button.

3. Press [NEXT] or [PREV] to select the desired item and press [ENTER] button. Now you can edit by [NEXT]

or [PREV] buttons the DMX value (0-255) for selected item:

Prg End.

a total number of the program steps (value 1-40). This value you should be set before

starting of programming (e.g. if you want to create program with the 10 steps,

set Prg End=10).

PAn

a coarse pan movement

PAn F

a fine pan movement

Tilt

a coarse tilt movement

Tilt F

a fine tilt movement

P/T Sp

a pan/tilt speed

Powr

power/special functions

Virt C

a virtual colour wheel

Red

a red colour coarse

Red F

a red colour fine

Green

a green colour coarse

Green F

a green colour fine

Blue

a blue colour coarse

Blue F

a blue colour fine

Amber

an amber colour

Amber F

an amber colour fine

CTC

a colour temperature correction

C Mix C

a colour mix control

Zoom

a zoom function

Zoom F

a zoom function fine

Stro

a strobe/shutter function

Dimm

a dimmer function coarse

Dim F

a dimmer function fine

F.Tim

a fade time (0-25.5 sec)

S.Tim

a step time (0-25.5 sec)

COPY

copying the current prog. step to

the next prog. step

4. Press [ENTER] button to confirm adjusted value . 5. Press [ESCAPE] button, select next prog. step, press [ENTER] button and repeat steps 3 - 5).

5.7 Reset
This option enables the ROBIN LEDBeam 350 to index all effects and return to their standard positions.

5.8 Special functions (Special)
RDM Low - this menu item shows the first part of the RDM identification code.
RDM High - this menu item shows the second part of the RDM identification code.
Wireless - Wireless DMX information. The menu allows to read some information about Wireless DMX operation
Stat - Wireless status. Use the menu to read wireless DMX status. Unlink - use this item to unlink fixture from wireless DMX.
Adjust - Adjustment. The menu allows the fine adjustment of effects. DMX Val- DMX values. Use the menu to set DMX values of fixture´s channels. Calib - calibration of white colour. Cal Mech - use this menu to calibrate pan/tilt/zoom position. Cal Col - the menu serves for calibration of white colours in the factory. User should not change settings in this menu. 21

Calibration of the pan/tilt/zoom via the control board

1. Disconnect DMX controller from the fixture and enter the "Cal Mech" menu.

2. Use the [PREV] and [NEXT] to find "Pan C" and press [ENTER].

3. Set desired value and save it by pressing [ENTER].

4. Repeat steps 2 and 3 for "Tilt C" and "Zoom C".

5. After calibrating all effects, find item "Store" and press [ENTER]. to save all adjusted values and reset the

fixture.

Calibration protocol

Effect

Mode 1

Mode 2

Mode 3

Pan-fine adjustment channel 23 channel 17 channel 25

Tilt - fine adjustment channel 24 channel 18 channel 26

Zoom -fine adjustment channel 25 channel 19 channel 27

Cal Load - Loads default (factory) calibration.

Sw Upd - Software update. The menu item allows you to update software in the fixture via either serial or USB port of PC. The following items are required in order to update software: - PC running Windows or Linux or macOS - DSU file - Flash cable RS232/DMX, P/N13050624 (if you want to use a serial port of PC) - Robe Universal Interface or Robe Universal interface WTX (if you want to use an USB port of PC)

After the software updating the fixture will be set to default (factory) values.

To update software in the fixture: 1. DSU file is available from Robe web site at WWW.robe.cz.
File with extension zip is intended for Windows (used and tested from XP to W10 on 32/64bit systems). File with extension tbz is intended for Linux (used and tested on Debian and Ubuntu 32/64bit). File with extension dmg is intended for macOS (used and tested on OSX up to Sierra) XQuartz required, install it from https://www.xquartz.org/ Save the download file to a folder on your computer. In case that you use windows, extract files in the zip file (e.g. DSU_RobinLedBeam350_18041738.zip) 2. Disconnect the fixture from DMX controller. 3. If you use the flash cable RS232/DMX, connect a serial port of your computer with DMX input of the fixture by means of the cable. If you use the Robe Universal Interface, connect a USB port of your computer with the Robe Universal Interface by means of the USB cable and DMX input of the fixture with the DMX output of the Robe Universal Interface via a DMX cable. 4. Switch the fixture to the update mode (Special --> SW Upd). Note: If you do not want to continue in the software update, you have to switch off and on the fixture to escape from the updating mode. We recommend to cancel all running programs on your computer before starting the software update. 5. Double-click the software uploader file (e.g. DSU_RobinLedBeam350_18041738.exe) in the extracted files. The Software Uploader program will start running.

6. Select correct "COM " number if you use a Flash cable RS232/DMX or select "Robe Universal Interface 1 " if you use the Robe Universal Interface/Robe Universal Interface WTX and then click on the "Connect" button.
22

7. If the connection is OK, click the "Start Uploading" button to start software uploading. It will take several minutes to perform software update. If the option "Incremental Update" is not checked, all processors will be updated (including processors with the same software version). If you wish to update only processors with new version of software, check the "Incremental Update box". Avoid interrupting the process. Update status is being displayed in the "Info Box" window. When the update is finished, the line with the text "Fixture is successfully updated" will appear in this window.
In case upload process is interrupted (e.g. power loss), the fixture stays in "Updating mode" and you will have to repeat the software update again.
Another way, how to update software in the fixtures (especially large installation of fixtures) is to use the ROBE Uploader. It is a software for automatized software update of Robe fixtures. It takes advantage of RDM support). For more information please see https://www.robe.cz/robe-uploader/.

6. RDM

This fixture supports RDM operation. RDM (Remote Device Management) is a bi-directional communications protocol for use in DMX512 control systems, it is the new open standard for DMX512 device configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting existing non-RDM equipment. By using a special ,,Start Code," and by complying with the timing specifications for DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights. RDM allows explicit commands to be sent to a device and responses to be received from it. The list of commands for ROBIN LEDBeam 350 is the following.

Parameter ID

Discovery command SET command

GET command

DISC_UNIQUE_BRANCH

*

DISC_MUTE

*

DISC_UN_MUTE

*

DEVICE_INFO

*

SUPPORTED_PARAMETERS

*

SOFTWARE_VERSION_LABEL

*

DMX_START_ADDRESS

*

*

IDENTIFY_DEVICE

*

*

DEVICE_MODEL_DESCRIPTION

*

MANUFACTURER_LABEL

*

DEVICE_LABEL

*

*

SENSOR_DEFINITION

*

SENSOR_VALUE

*

DISPLAY_INVERT

*

*

DISPLAY_LEVEL

*

*

PAN_INVERT

*

*

TILT_INVERT

*

*

DEVICE_RESET

*

DMX_PERSONALITY

*

*

DMX_PERSONALITY_DESCRIPTION

*

STATUS_MESSAGES

*

STATUS_ID_DESCRIPTION

*

DEVICE_HOURS

*

PARAMETER_DESCRIPTION

*

23

ROBE_DMX_INPUT ROBE_WIRELESS_UNLINK
RDM model ID for the Robin LEDBeam 350 is 0x0113.

*

*

*

7. Error and information messages
Tilt Err This message will appear after reset of the fixture if the head´s indexing circuit malfunctions (sensor failed) or the stepping motor or its driving PCB is defective. The head is not located in the default tilt position after fixture reset.
Pan Err This message will appear after reset of the fixture if the head´s indexing circuit malfunctions (sensor failed) or the stepping motor or its driving PCB is defective. The head is not located in the default pan position after fixture reset.
Zoom Err This message will appear after reset of the fixture if the zoom module is not located in the default position. Cause of the message can be some defective zoom stepping motor.
Red Shrt The message informs you that short circuit has occured in the red LEDs circuit on the LEDs PCB.
Green Shrt The message informs you that short circuit has occured in the green LEDs circuit on the LEDs PCB.
Blue Shrt The message informs you that short circuit has occured in the blue LEDs circuit on the LEDs PCB.
Amber Shrt The message informs you that short circuit has occured in the amber LEDs circuit on the LEDs PCB.
Red Unp The message informs you that red LEDs circuit has been interrupted on the LEDs PCB.
Green Unp The message informs you that green LEDs circuit has been interrupted on the LEDs PCB.
Blue Unp The message informs you that blue LEDs circuit has been interrupted on the LEDs PCB.
Amber Unp The message informs you that amber LEDs circuit has been interrupted on the LEDs PCB.
Clea Air F The message informs you that the item "R Ti" is at 0 value (in the menu "Air fil"). Clean air filter in the fixture base reset this counter.
24

8. Technical Specifications

Electrical

Power supply: electronic auto-ranging Input voltage range: 100-240V, 50-60Hz Fuse: T 6.3A/250V ~ Max. power consumption: 450W (power factor: 0.96) Mains input: - max. 16A (US 13A)

Source

Light source type: 12 RGBA multichips LED life expectancy: min. 20.000 hours Typical lumen maintenance: 70% @ 20.000 hour

Optical System
Robe's proprietary optical design Zoom range: 3.8° - 60° (LedBeam 350 RGBA, LedBeam 350 FW RGBA ) Two light output modes: CRI and High output CRI >= 90 (at CRI light output mode)

Virtual colour wheel
66 pre-programmed colours Rainbow effect with in both directions with variable speed

CTO

Variable CTO 2700K-8000K Pre-programmed whites 2.700K, 3.200K, 4.200K, 5.600K and 8.000K Halogen lamp effect at whites 2700K-4200K

Strobe

Strobe effect with variable speed (0.3 - 20Hz) Random strobe pulse-effect with variable speed Opening/closing pulse effect with variable speed

Dimmer

Smooth dimmer from 0 - 100 %

Pan/Tilt Control

Max. pan movement range: 540° or 450°(switchable) Max. tilt movement range: 228° 16 bit movement resolution Automatic Pan/Tilt position correction Remotely controllable speed of pan/tilt movement for easy programming
Two-row LCD display & 4 control buttons Readout fixture usage, receiving DMX values, temperatures, etc Built-in analyzer for easy fault finding, error messages Built-in demo sequences Silent fans cooling, Stand-alone operation 3 user editable programs, each up to 40 steps Supported protocols: USITT DMX 512, RDM, Support of RDM (Remote Device Management) 3 DMX modes (22, 16, 24 control channels)

25

External Wireless DMX/RDM module (optional) Compliance with USITT DMX-512 (1986 & 1990) and 512-A Full DMX fidelity and frame integrity Auto sensing of DMX frame rate and frame size <5ms DMX latency Operational frequency range of 2402-2480 MHz Producer: LumenRadio

Max. number of fixtures in Ethernet IN/Out line (EP version only) 8
Connection
DMX data in/out: Locking 5-pin XLR Ethernet In/Out: 2 x RJ 45 (Robin LEDBeam 350 RGBA EP only) Power IN: Neutrik powerCON TRUE1 Power OUT: Neutrik powerCON TRUE1

Rigging

Mounting points: 2 pairs of 1/4-turn locks Mounting horizontally or vertically via Omega bracket

Temperatures
Maximum ambient temperature : 45° C Maximum housing temperature : 70° C

Distances

Min. distance from flammable surfaces: 0.4 m Min. distance of illuminated objects: 1.5 m

Total heat dissipation 1153 BTU/h (calculated)
Weight: 9.85 kg
Dimensions (mm)

26

Accessories 1 x Omega adapter CL-regular 2 pcs in box (P/N 10980033)
Optional accessories (P/N 10980559) Diffusion Filter 2° for LEDBeam 350 (P/N 10980560) EggCrate for LEDBeam 350 (P/N 10980127) ROBE Wireless CRMX Dongle (P/N 1305 2405) Mains Cable PowerCon In TRUE1/Schuko, 2m, indoor (P/N 1305 2406) Mains Cable PowerCon In TRUE1/US, 2m, indoor (P/N 1305 2407) Mains Cable PowerCon In TRUE1/open ended, 2m, indoor (P/N 13052445) Mains Cable PowerCon In TRUE1/CEE 16A, 2m, indoor (P/N 1305 2439) Daisy Chain PowerCon TRUE1 In/Out, EU, 2m, indoor (P/N 1305 2440) Daisy Chain PowerCon TRUE1 In/Out, US, 2m, indoor (P/N 13052444) Daisy Chain PowerCon TRUE1 In/Out, EU, 5m, indoor (P/N 17030386) Doughty Trigger Clamp (P/N 99011963) Safety wire 35 kg
9. Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on or within the fixture. Otherwise, the fixture`s light output will be significantly reduced. Regular cleaning will not only ensure the maximum light output, but will also allow the fixture to function reliably throughout its life. A soft lint-free cloth moistened with any weak detergent solution is recommended for cleaning fixture´s covers, under no circumstances should alcohol or solvents be used!
DANGER ! Disconnect from the mains before starting any
maintenance and cleaning work
The interior of the fixture should be cleaned at least annually using a vacuum cleaner or compressed air. The cooling fans should be cleaned at least twice a year.
Important! Never use alcohols (ethanol, methanol, isopropyl alcohol), acetone and another aggressive solvents for cleaning the front lens array.
Recommended steps for cleaning the LED lens array: 1. Use low-pressure compressed air to remove coarse dust from lenses. 2. Use distilled water with weak detergent solution and lint-free small cloth for further cleaning of lenses. 3. Use an antistatic, alcohol-free screen cleaner (we recommend the Lyreco Screen Cleaner) and polish lenses
until they are dry. 4. Check the lenses are dry before reapplying power.
Note: potential foggy front lens array does not influence function of the fixture and does not subject to complaint.
Periodically clean the air filter placed in the fixture base. This air filter is placed under a grille, which is fastened by means of two magnets. Use a vacuum cleaner, compressed air or you can wash them and put back dry. After replacing the air filter, set the remaining time counter in the menu "Fixture Information" (Info--->Air fil. --->R.Ti) More complicated maintenance and service operations are only to be carried out by authorized distributors.
27

9.1 Replacing fuse
1.Replace the fuse by a fuse of the same type and rating only.
Before replacing the fuse, unplug mains lead!
1. Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clockwise).
2. Remove the old fuse from the fuse holder. 3. Install the new fuse in the fuse holder (only the same type and rating). 4. Replace the fuseholder in the housing and fix it.
10. Photometric diagrams
Robin LedBeam 350 RGBA Min. zoom - CRI light output mode
28

Max. zoom - CRI light output mode 29

Min. zoom - High light output mode 30

Max. zoom - High light output mode 31

11. ChangeLog

This section summarizes changes in the user manual.

Version of the Date of issue manual

Description of changes

1.1

17/06/2021

Menu calibration changed

1.2

31/07/2021

Eggcrate installation added

1.3

12/08/2021

EP version added

1.4

03/09/2021

DMX chart ver. 1.1

1.5

24//01/2022 Ethernet connection for EP version added

1.6

03/02/2022

Light output mode added to display menu, DMX chart ver. 1.2

1.7

09/03/2022

DMX chart ver. 1.3

1.8

01/04/2022

Safety instructions changed

1.9

13/04/2022

Diffusion filter installation changed

2.0

04/10/2022

Colors calibration changed

October 4, 2022 Copyright © 2020-2022 Robe Lighting - All rights reserved All Specifications subject to change without notice Made in ROBE Lighting s.r.o., Palackého 416, 757 01 Valasské Meziící, Czech Republic
32

DMX protocol

Robin LedBeam 350 RGBA/Robin LedBeam 350FW RGBA - DMX protocol

Version: 1.3 Mode 1-Standard 16-bit, Mode 2 -Reduced 8-bit, Mode 3 - Cpulse mode

Mode/channel

1

2

3

DMX Value

Function

1

1

1

Pan (8 bit)

0 - 255 Pan movement by 540° or 450° (128=default)

2

2

2

Pan Fine (16 bit)

0 - 255 Fine control of pan movement (0=default)

3

3

3

Tilt (8 bit)

0 - 255 Tilt movement by 228° (128=default)

4

4

4

Tilt fine (16 bit)

0 - 255 Fine control of tilt movement (0=default)

5

5

5

Pan/Tilt speed , Pan/Tilt time

0 Standard mode (0=default)

1 Max. Speed Mode

Pan/Tilt speed mode

2 - 255 Speed from max. to min.

Pan/Tilt time mode

2 - 255 Time from 0.2 sec. to 25.5 sec.

6

6

6

Power/Special functions

0 -19 Reserved (0=default) To activate following functions, stop in DMX value for at least 3 s

and shutter must be closed at least 3 sec. (,,Shutter,Strobe"

channel 20/15/22 must be at range: 0-31 DMX). Corresponding

menu items are temporarily overriden.

20-24 Display On

25-29 Display Off

30-34 RGBA colour mixing mode

35-39 CMY colour mixing mode

40-44 Pan/Tilt speed mode

45 - 49 Pan/Tilt time mode

50 -54 Blackout while pan/tilt moving

55 -59 Disabled blackout while pan/tilt moving

60 - 64 Dimmer curve: Square law

65 - 69 Dimmer curve: Linear

70 - 74 Fans mode: Auto

75 - 79 Fans mode: High

80-84 White point 8000K ON

85-89 White point 8000K OFF

90-94 Reserved

95-99 Pan 540°

100-104 Pan 450°

105-109 Quiet mode: Fans On at blackout

110-114 Quiet mode: Fans Off at blackout

115-119 High light output mode

120-124 CRI light output mode

125 -129 Reserved

To activate following functions, stop in DMX value for at least 3 seconds. Corresponding menu items are temporarily overriden.
130 - 139 Reserved

Type of control
proportional
proportional
proportional
proportional
step step
proportional
proportional
step step step step step step step step step step step step step step
step step step step step step

Page 1

Mode/channel

1

2

3

*

*

7

*

*

8

DMX protocol

DMX Value

Function

140 - 149 Pan/Tilt reset

150 - 159 Zoom reset

160 - 169 Reserved

Tungsten effect simulution for whites 2700K-4200K

170-171 Tungsten effect simulation (750W) On

172-173 Tungsten effect simulation (1000W) On

174-175 Tungsten effect simulation (1200W) On

176-177 Tungsten effect simulation (2000W) On

178-179 Tungsten effect simulation (2500W) On

180-181 Tungsten effect simulation Off

182-199 Reserved

200 - 209 Total fixture reset

210 - 218 Reserved
The following RoboSpot related commands are only applicable when the RoboSpot is connected:

219 - 220 RoboSpot enabled

221 - 222 RoboSpot disabled - except handle faders and pan/tilt

223 - 224 RoboSpot fully disabled

225 - 240 Reserved

241 - 255 Quiet mode - fan noise control from min. to max.

LED frequency selection Factory display menu setting: 600Hz

Select PWM output frequency of LEDs (DMX mode 3 only). Selected PWM frequency can be fine adjusted in 127 steps up/down around selected PWM frequency on the channel below. Corresponding menu item (Frequency Setup) is temporarily overridden.

0-4 PWM frequency from Display menu (fixture utilizes PWM

frequency set in the display menu item Frequency Setup).

5-9 300 Hz

10-14 600 Hz (10=default)

15-19 1200 Hz

20-24 2400 Hz

25-29 High

30-255 Reserved (fixture utilizes PWM frequency set in the display menu item

Frequency Setup).

LED frequency fine adjusting Factory display menu setting: 600Hz
Select desired PWM output frequency of LEDs on the channel above (DMX
mode 3 only).

0-1 Selected LED Frequency

2 LED Frequency (step -126)

3 LED Frequency (step -125)

4 LED Frequency (step -124)

:

125 LED Frequency (step -3)

126 LED Frequency (step -2)

127 LED Frequency (step -1)

128 Selected LED Frequency (128=default)

129 LED Frequency (step +1)

130 LED Frequency (step +2)

131 LED Frequency (step +3)

Type of control
step step step
step step step step step step
step
step step step step proportional
step
step step step step step
step step step step
step step step step step step step

Page 2

Mode/channel

1

2

3

7

7

9

DMX protocol

DMX Value
: 252 253 254 255
0 1-2 3-4 5-6 7-8 9-10 11-12 13-14 15-16 17-18 19-20 21-22 23-24 25-26 27-28 29-30 31-32 33-34 35-36 37-38 39-40 41-42 43-44 45-46 47-48 49-50 51-52 53-54 55-56 57-58 59-60 61-62 63-64 65-66 67-68 69-70 71-72 73-74 75-76 77-78 79-80 81-82 83-84

Function
LED Frequency (step +124) LED Frequency (step +125) LED Frequency (step +126) Selected LED Frequency
Virtual colour wheel
No function (0=default) Filter 4 (Medium Bastard Amber) Filter 25 (Sunset Red) Filter 19 (Fire) Filter 26 (Bright Red) Filter 58 (Lavender) Filter 68 (Sky Blue) Filter 36 (Medium Pink) Filter 89 (Moss Green) Filter 88 (Lime Green) Filter 90 (Dark Yellow Green) Filter 49 (Medium Purple) Filter 52 (Light Lavender) Filter 102 (Light Amber) Filter 103 (Straw) Filter 140 (Summer Blue) Filter 124 (Dark Green) Filter 106 (Primary Red) Filter 111 (Dark Pink) Filter 115 (Peacock Blue) Filter 126 (Mauve) Filter 117 (Steel Blue) Filter 118 (Light Blue) Filter 122 (Fern Green) Filter 182 (Light Red) Filter 121 (Filter Green) Filter 128 (Bright Pink) Filter 131 (Marine Blue) Filter 132 (Medium Blue) Filter 134 (Golden Amber) Filter 135 (Deep Golden Amber) Filter 136 (Pale Lavender) Filter 137 (Special Lavender) Filter 138 (Pale Green) Filter 798 (Chrysalis Pink) Filter 141 (Bright Blue) Filter 147 (Apricot) Filter 148 (Bright Rose) Filter 152 (Pale Gold) Filter 154 (Pale Rose) Filter 157 (Pink) Filter 143 (Pale Navy Blue) Filter 162 (Bastard Amber)

Page 3

Type of control
step step step step
step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step step

Mode/channel

1

2

3

8

8

10

9

*

11

10

9

12

11

*

13

12

10

14

13

*

15

14

11

16

15

*

17

16

12

18

DMX protocol

DMX Value 85-86 87-88 89-90 91-92 93-94 95-96 97-98 99-100 101-102 103-104 105-106 107-108 109-110 111-112 113-114 115-116 117-118 119-120 121-122 123-124 125-126 127-128 129-130 131-132 133-235 236-245 246-255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0-255
0 - 255
0 - 255

Function
Filter 164 (Flame Red) Filter 165 (Daylight Blue) Filter 169 (Lilac Tint) Filter 170 (Deep Lavender) Filter 172 (Lagoon Blue) Filter 194 (Surprise Pink) Filter 180 (Dark Lavender) Filter 181 (Congo Blue) Filter 197 (Alice Blue) Filter 201 (Full C.T. Blue) Filter 202 (Half C.T. Blue) Filter 203 (Quarter C.T. Blue) Filter 204 (Full C.T. Orange) Filter 219 (Fluorescent Green) Filter 206 (Quarter C.T. Orange) Filter 247 (Filter Minus Green) Filter 248 (Half Minus Green) Filter 281 (Three Quarter C.T. Blue) Filter 285 (Three Quarter C.T. Orange) Filter 352 (Glacier Blue) Filter 353 (Lighter Blue) Filter 507 (Madge) Filter 778 (Millennium Gold) Filter 793 (Vanity Fair) Raw DMX Rainbow effect (with fade time) from slow-> fast Rainbow effect (without fade time) from slow-> fast
Red/Cyan (8 bit)*
Colour saturation control - coarse 0-100% (255=default)
Red/Cyan (16bit)*
Colour saturation control - fine (255=default)
Green/Magenta (8 bit) *
Colour saturation control - coarse 0-100% (255=default)
Green/Magenta (16bit) *
Colour saturation control - fine (255=default)
Blue/Yellow (8 bit) *
Colour saturation control - coarse 0-100% (255=default)
Blue/ Yellow (16bit) *
Colour saturation control - fine (255=default)
Amber (8 bit)
If RGBA mode is selected: Colour saturation control - coarse 0-100% (255=default) If CMY mode is selected: No function
Amber (16 bit)
Colour saturation control - fine (255=default)
CTC
If function "White Point 8000K" is On:

0-255

Col. temperature correction from 8000K to 2700K -for whites only
Page 4

Type of control
step step step step step step step step step step step step step step step step step step step step step step step step proportional proportional proportional
proportional
proportional
proportional
proportional
proportional
proportional
proportional
proportional
proportional

Mode/channel

1

2

3

17

13

19

18

14

20

19

*

21

20

15

22

21

16

23

22

*

24

DMX protocol

DMX Value

Function

(0=8000K, 64=5600K, 128=4200K, 192=3200K, 255=2700K) To get colour temperatures stated above, RGBA channels have to

be set at the same value e.g. 255DMX (0=default)

If function "White Point 8000K" is Off:

0-255 Colour temperature correction for from cool white to 2700K

Colour Mix control

Defines relation between colour channels

"Virtual" = Virtual Colours (Virtual Colour Wheel)

"Colour mix" = Colour channels (RGBA/CMY)

0-9 Virtual colors ("Virtual" has priority)

10-19 Maximum mode (highest values have priority)

20-29 Minimum mode (lowest values have priority)

30-39 Multiply mode (multiply Virtual and Colour Mix)

40-49 Addition mode (Virtual + Colour mix) (45=default)

50-59 Subtraction mode (Virtual ­ Colour mix)

60-69 Inverted Subtraction mode (Virtual ­ Colour mix)

70-128 Reserved

129 Virtual colors (virtual has priority)

130-254 Crossfade (crossfade between Virtual and Colour mix)

255 Colour channels ("Colour mix" has priority)

Zoom

0-255 Zoom from max. to min.beam angle (128=default)

Zoom - fine

0-255 Fine zooming (0=default)

Shutter/ strobe

0 - 31 Shutter closed

32 - 63 Shutter open (32=default)

64 - 95 Strobe-effect from slow to fast

96 - 127 Shutter open

128 - 143 Opening pulse in sequences from slow to fast

144 - 159 Closing pulse in sequences from fast to slow

160 - 191 Shutter open

192 - 223 Random strobe-effect from slow to fast

224 - 255 Shutter open

Dimmer intensity (8 bit)

0 - 255 Dimmer intensity from 0% to 100% (0=default)

Dimmer intensity - fine (16 bit)

0 - 255 Fine dimming (0=default)

Type of control
proportional
step step step step step step step
step proportional
step
proportional
proportional
step step proportional step proportional proportional step proportional step
proportional
proportional

*Select RGBA or CMY mixing mode on channel "Power/Special functions" .

Copyright © 2021-2022 Robe Lighting s.r.o. - All rights reserved All Specifications subject to change without notice

Page 5

Robin LEDBeam 350 RGBA/350 FW RGBA - colours on Virtual Colour Wheel (software version 4.9 /IC3/ and higher)

Colour name
Filter 4 (Medium Bastard Amber) Filter 25 (Sunset Red)

Red (DMX)
120 255

Green (DMX)
116 3

Blue (DMX)
26 3

Filter 19 (Fire)

255

0

0

Filter 26 (Bright Red)

255

0

0

Filter 58 (Lavender) Filter 68 (Sky Blue) Filter 36 (Medium Pink) Filter 89 (Moss Green)

0

47

165

0

250

138

200

55

26

0

255

0

Filter 88 (Lime Green)

162

236

0

Filter 90 (Dark Yellow Green)

2

255

0

Filter 49 (Medium Purple)

255

0

27

Filter 52 (Light Lavender) Filter 102 (Light Amber) Filter 103 (Straw)

217

213

51

219

186

0

248

255

13

Filter 140 (Summer Blue)

66

253

37

Filter 124 (Dark Green)

16

255

3

Filter 106 (Primary Red)

255

3

1

Filter 111 (Dark Pink) Filter 115 (Peacock Blue) Filter 126 (Mauve) Filter 117 (Steel Blue)

255

116

48

4

255

37

255

0

39

130

255

38

Filter 118 (Light Blue)

9

255

82

Filter 122 (Fern Green)

35

255

0

Filter 182 (Light Red)

255

16

2

Filter 121 (Filter Green) Filter 128 (Bright Pink) Filter 131 (Marine Blue)

143

255

0

255

0

31

22

255

44

Filter 132 (Medium Blue)

7

228

120

Filter 134 (Golden Amber)

164

83

0

Filter 135 (Deep Golden Amber)

255

50

0

Filter 136 (Pale Lavender) Filter 137 (Special Lavender) Filter 138 (Pale Green) Filter 798 (Chrysalis Pink)

134

123

30

150

183

62

193

255

16

49

17

144

Filter 141 (Bright Blue)

0

225

62

Filter 147 (Apricot)

148

101

5

Filter 148 (Bright Rose)

255

30

13

Filter 152 (Pale Gold) Filter 154 (Pale Rose) Filter 157 (Pink)

117

131

14

176

138

14

243

85

18

Filter 143 (Pale Navy Blue)

0

210

75

Filter 162 (Bastard Amber)

253

239

28

Filter 164 (Flame Red)

253

0

0

Filter 165 (Daylight Blue) Filter 169 (Lilac Tint) Filter 170 (Deep Lavender)

9

255

106

211

224

28

195

177

78

Amber (DMX)
219 201
36 0
255 45
229 80
108 0 0
229 255 245
45 34
0 255
29 0
83 11 102
0 59 103 102
0 0 0 10 16 87 32 0 163 39 186 122 83 73 150 82 61 116 149

1

Colour name
Filter 172 (Lagoon Blue) Filter 194 (Surprise Pink) Filter 180 (Dark Lavender) Filter 181 (Congo Blue) Filter 197 (Alice Blue) Filter 201 (Full C.T. Blue) Filter 202 (Half C.T. Blue) Filter 203 (Quarter C.T. Blue) Filter 204 (Full C.T. Orange) Filter 219 (Fluorescent Green) Filter 206 (Quarter C.T. Orange) Filter 247 (Filter Minus Green) Filter 248 (Half Minus Green) Filter 281 (Three Quarter C.T. Blue) Filter 285 (Three Quarter C.T. Orange) Filter 352 (Glacier Blue) Filter 353 (Lighter Blue) Filter 507 (Madge) Filter 778 (Millennium Gold) Filter 793 (Vanity Fair)

Red (DMX)
0 95 139 23 75 135 180 192 196 80 184 189 191 173 238
0 0 255 240 255

Green (DMX)
255 133 107
0 222 242 255 255 155 155 190 158 200 246 172 173 222
0 32
5

Blue (DMX)
71 53 126 255 156 64 48 40
4 23 14 38 33 61
5 55 51
0 0 26

Amber (DMX)
10 102
19 3
26 36 35 99 103 26 94 176 255 11 52 51 83 109 143 48

2



References

Adobe PDF Library 15.0 Adobe InDesign CC 2015 (Windows)