VEVOR Fuel Caddy User Manual - JGC16PH, JGC16PH2

VEVOR Fuel Caddy User Manual

Model: JGC16PH, JGC16PH2

Tough Tools, Half Price

Technical Support and E-Warranty Certificate: www.vevor.com/support

Introduction

This manual provides instructions for the VEVOR Fuel Caddy, models JGC16PH and JGC16PH2. VEVOR is committed to providing tools at competitive prices. The terms "Save Half" or "Half Price" represent an estimate of potential savings compared to major brands and should be verified at the time of purchase.

For product questions or technical support, please contact: CustomerService@vevor.com.

Please read all instructions carefully before operating. VEVOR reserves the right to interpret this user manual. Product appearance is subject to the received item.

Safety Information

General Safety Rules

WARNING: 1. Read and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. 2. Failure to follow safety rules may result in serious personal injury.

  • This product is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety.
  • Wear proper protective equipment when installing or using this product.
  • Ensure all fittings and threaded connections are tightened and leak-free before operating.

DANGER! Flammable Fuels

Fuels are extremely flammable. Keep away from heat, sparks, and open flames. ⚠️

  • Do not use electronics or mobile communication devices such as mobile phones when pumping flammable liquids.
  • Attach a ground wire and bond containers that are being pumped from and into. Ground all containers to a known ground source to dissipate static electricity before pumping liquids. ⚡
  • Fuel vapors can explode. Harmful or fatal if swallowed. Avoid breathing in fuel vapors.
  • Do not smoke near or while using the fuel caddy. ?
  • This product is intended for fuel transfer only and is not intended to transport fuel in any vehicle or trailer.

WARNING! CAUTION! ATTENTION!

  • Do not modify this product.
  • Do not use this product for prolonged fuel storage.
  • Use the caddy for one fuel type only to avoid possible damage.
  • Monitor flow rate and fill level to prevent overflows and spills.
  • Always empty the pump and hose after using the caddy. Lift the hose and turn the handle in the opposite direction to empty all remaining liquid back into the caddy.
  • Caution when filling the caddy through the fill tube; monitor closely to prevent overflows or spills.
  • This product is unsuitable for placing in a yacht, off-road vehicle, and another violent vibration place.

Never use the fuel caddy near open flames or heat sources. ?

SAVE THESE INSTRUCTIONS

Model and Parameters

Model JGC16PH JGC16PH2
Capacity 16 Gal 16 Gal(single)
Fuel Type Diesel, Lubricating Oil, Gasoline
Oil Discharge Hand oil gun
Max. Flow 7.8 L/min (Oil gun is 0.5m below the tank outlet)
Hose Φ19(Inside Diameter)x250cm
Wheel 6"
Package 1 2
Material PE
Color Red

Structure Diagram

The fuel caddy consists of the following parts:

  • 1. Handle
  • 2. Fuel Tank
  • 3. Fixed Wheel
  • 4. Outlet
  • 5. Fixed Mount
  • 6. Fuel Tank Cap
  • 7. Hose
  • 8. Hand Fuel Gun

[Diagram showing the assembled fuel caddy with numbered labels pointing to the handle, fuel tank, wheels, outlet, fixed mount, fuel tank cap, hose, and hand fuel gun.]

Components (Single Unit)

No. Picture Description Name and Qty No. Picture Description Name and Qty
1 [Red fuel tank] Fuel Tank (x1) 6 [Silver metal ball valve fitting] Direct Ball Valve Joint (x1)
2 [Black plastic mounting bracket] Fixed Mount (x1) 7 [Silver metal hose clamp] Hose Clamp (x2)
3 [Black screw-on fuel tank cap] Fuel Tank Cap (x1) 8 [Silver metal bolt] Bolt (x3)
4 [Black and silver hand-operated fuel gun nozzle] Fuel Gun (x1) 9 [Black rectangular mounting plate] Fixing Plate (x1)
5 [Gray coiled hose] Long Hose (x1) 10 [Placeholder symbol] User Manual (x1)

Assembly Instructions

Step 1

Install the fixed mount (2) and fixing plate (9), securing them with bolt (8). Attach the fuel tank cap (3).

[Diagram showing the installation of the fixed mount, fixing plate, bolts, and fuel tank cap onto the main unit.]

Step 2

Install the direct ball valve joint (6) at the bottom outlet of the tank. Connect the fuel gun and the fuel tank outlet using the long hose (5), and secure them with hose clamps (7).

[Diagram showing the connection of the ball valve joint, hose, and fuel gun to the fuel tank.]

Step 3

Ensure all components are tightened. The product is now assembled and ready for use.

[Diagram showing the fully assembled fuel caddy.]

Operation

Refueling Operation

  • Select the appropriate oil for filling. Do not fill with chemicals or other corrosive solvents.
  • Lay the tank flat and ensure the direct ball valve joint is closed.
  • Open the tank cap and fill the oil.
  • During filling, monitor the tank to avoid overflow.
  • After filling, tighten the cap and place the tank in a safe location.

Pumping Operation

  • Place the tank vertically and turn the air valve of the fuel tank cap counterclockwise.
  • Ensure the oil level in the tank is at least 0.5 meters higher than the fuel gun. Press the fuel gun to refuel.
  • After oil discharge, the switch on the fuel gun handle can be locked for continuous flow.
  • As the oil level decreases, the flow will decrease. Raise the tank so the oil level is higher than the fuel gun.
  • When finished, raise the gun above the tank to recover remaining oil in the hose and return it to the tank.
  • Close the direct ball valve joint and the air valve of the fuel tank cap.

Maintenance

  1. Clean the measure and filter regularly.
  2. Keep away from fire. ?
  3. For different types of oil, cleaning the tank before storing another type is recommended.
  4. If the product is not used for a long time, clean and store it in a cool, dry environment.

Manufacturer: Sanven Technology Ltd.

Address: Suite 250, 9166 Anaheim Place, Rancho Cucamonga, CA 91730

Made in China

Models: JGC16PH 16 Gallon Fuel Caddy Portable Gas Storage Tank, JGC16PH, 16 Gallon Fuel Caddy Portable Gas Storage Tank, Caddy Portable Gas Storage Tank, Portable Gas Storage Tank, Gas Storage Tank, Storage Tank

File Info : application/pdf, 12 Pages, 359.53KB

PDF preview unavailable. Download the PDF instead.

81ELvUDTzAL

References

WPS 文字

Related Documents

Preview VEVOR JGC16PH, JGC16PH2 Fuel Caddy User Manual
User manual for VEVOR Fuel Caddy models JGC16PH and JGC16PH2. Provides assembly, operation, safety, and maintenance instructions for fuel transfer. Features include portability, hand pump, and suitability for gasoline, diesel, and lubricating oil.
Preview VEVOR 30/35 Gallon Caddy Owner's Manual
Owner's manual for the VEVOR 30/35 Gallon Caddy, providing essential safety instructions, detailed parts identification, and a step-by-step assembly guide for proper operation and maintenance.
Preview VEVOR DC Fuel Transfer Pump DCEX50A: User Manual & Specifications
Explore the VEVOR DC Fuel Transfer Pump (Model DCEX50A) with this comprehensive guide. Find detailed specifications, safety instructions, accessory lists, and troubleshooting tips for efficient fuel transfer. Visit www.vevor.com/support for assistance.
Preview VEVOR Fuel Transfer Pump MX102 Owners Installation, Operation, and Safety Manual
Comprehensive manual for the VEVOR Fuel Transfer Pump, Model MX102. Covers installation, operation, safety precautions, electrical wiring, troubleshooting, specifications, and parts list for 12V DC 16 GPM pumps used with gasoline, diesel, kerosene, and biodiesel.
Preview VEVOR Juice Dispenser: Features, Installation, and Operation Guide
VEVOR Commercial Beverage Dispenser manual. This guide covers features, technical specifications, installation, operation, and cleaning for VEVOR 2, 3, and 4-tank juice dispensers, including 12L and 6.4 Gallon models.
Preview VEVOR KEX16 Fuel Transfer Pump User Manual
Official instruction manual for the VEVOR KEX16 Fuel Transfer Pump. Includes safety, installation, operation, troubleshooting, and specifications for this 16 GPM DC pump.
Preview VEVOR Water Storage Tank User Manual RB-0200/RB-0380
User manual for VEVOR collapsible water storage tanks, models RB-0200 and RB-0380. Provides instructions on setup, use, maintenance, and storage for these PVC rainwater collection systems.
Preview 17-Gallon Low-Profile Oil Drain with Pump Owner's Manual
Owner's manual for the 17-gallon low-profile oil drain with pump, including assembly, operation, safety guidelines, and maintenance instructions.