Installation Guide for GE current models including: GELP24-100U-GLX, DISP105, GELP24-100U-GLX LED Refrigerated Display Lighting, LED Refrigerated Display Lighting, Refrigerated Display Lighting, Display Lighting, GELP24-100U-GLX Immersion LED Refrigerated Display Lighting, Immersion LED Refrigerated Display Lighting, 93077673 100W LED Driver

Immersion Refrigerated Display Lighting GELP24-100U-GLX LED Driver — Installation Guide | DISP105

LED Lighting, LED Fixtures, Indoor Lighting, Refrigerated Display Lighting, Immersion, 100W, Installation Guide, LED Driver, GELP24-100U-GLX

GE Current a Daintree Company

Library | Spec Sheets | Installation Guides | Current

Immersion GELP24-100U-GLX Power Supply Installation Guide | DISP105

Immersion Elite French Door Indoor Lighting | Refrigerated Display | Current


File Info : application/pdf, 3 Pages, 243.25KB

PDF preview unavailable. Download the PDF instead.

DISP105-LED-Refrigerated-Display-Lighting-Immersion-GELP24-100U-GLX-Driver
ImmersionTM
LED Refrigerated Display Lighting
Vertical & Horizontal Cases 93077673 100W LED Driver GELP24-100U-GLX

EN Installation Guide DISP105
24
Volt

BEFORE YOU BEGIN
Read these instructions completely and carefully.

BG                 : https://products. gecurrent.com/eu
CS Návod k montází a bezpecnostní informace v cestin najdete zde: https://products.gecurrent.com/eu
DA Den danske version af installationsvejledningen og sikkerhedsoplysninger kan findes på følgende placering: https://products.gecurrent.com/eu
DE Die deutsche Version der Installationsanleitung und Sicherheitsinformationen finden Sie in folgendem Verzeic: https://products.gecurrent.com/eu
EL                : https://products.gecurrent.com/eu
ES La versión española de las instrucciones de instalación y la información sobre seguridad puede encontrarse en la siguiente ubicación: https://products.gecurrent.com/eu
ET Eestikeelse paigaldusjuhendi ja ohutusnñuded leiate aadressilt: https://products.gecurrent.com/eu

FI Asennusohjeiden ja turvallisuustietojen suomenkielinen versio löytyy seuraavasta paikasta: https://products. gecurrent.com/eu
FR La version française des instructions d'installations et information de sécurité est disponible à l'adresse suivante: https://products.gecurrent.com/eu
HR Hrvatska verzija prirucnika za ugradnju i sigurnosnih informacija nalazi se na sljedecoj lokaciji: https:// products.gecurrent.com/eu
HU A telepítési útmutató és a biztnosági információk magyar nyelv változata az alábbi címen található: https://products.gecurrent.com/eu
IT La versione italiana del manuale di installazione e sicurezza può essere reperita nella seguente sezione: https://products.gecurrent.com/eu
LT Lietuvisk diegimo instrukcijos ir saugos informacijos versij galima rasti sioje vietoje: https://products. gecurrent.com/eu
LV Uzstdsanas instrukciju un drosbas informciju latviesu valod var atrast seit: https://products.gecurrent.com/eu

NL De Nederlandse versie van de installatie-instructies en veiligheidsinformatie kan op de volgende locatie worden gevonden: https://products.gecurrent.com/eu
PL Polsk wersj instrukcji instalacji oraz informacje dotyczce bezpieczestwa mona znale w nastpujcej lokalizacji: https://products.gecurrent. com/eu
PT A versão em Português das instruções de instalação e das informações de segurança pode ser encontrada na seguinte localização: https://products.gecurrent.com/eu
RO Versiunea în limba român a instruciunilor de instalare i a informaiilor de siguran pot fi gsite la: https:// products.gecurrent.com/eu
SV Ni hittar den svenska versionen av installationsanvisningarna och säkerhetsinformationen på följande plats: https://products.gecurrent.com/eu
SL Previdnostna opozorila in varnostne informacije so na zadnji strani vodnika za namestitev. Pred zacetkom namestitve izdelka jih skrbno preberite: https://products. gecurrent.com/eu
SK Slovenskú verziu montaznej prírucky a bezpecnostnch instrukcií nájdete na nasledujúcej lokalite: https:// products.gecurrent.com/eu

For the latest North American install guides for your product go to: https://products.gecurrent.com/sign-lighting/tetra-max For the latest European install guides for your product go to: https://products.gecurrent.com/eu

FOR YOUR SAFETY
Read and observe all CAUTIONS and WARNINGS shown throughout these instructions.
· Installation to be performed by factory trained service personnel only.
· For use inside a commercial refrigeration case with packaged foods only.
· Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
· Before installing, servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out/tag out safety procedures

PREPARE ELECTRICAL WIRING Electrical Requirements
· The power supply must be supplied with 120-277 VAC, 50/60 Hz, and connected to an individual properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker or time delay fuse.
· Wiring must be 2 wire with ground and rated for 75°C (167°F). · All wiring must be done to NEC or local electrical codes.
Grounding Instructions­Cable Direct
· This lighting system must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and be connected to the equipment grounding terminal.

ImmersionTM GELP24-100U-GLX Driver

Installation Guide

CAUTION / ATTENTION
Risk of injury. While performing installations described, gloves, safety glasses or goggles should be worn. Risque de blessure. Lors de l'exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées.
UL WARNING / AVERTISSEMENT UL
Risk of electrical shock. Disconnect power before servicing or installing product. LED Retrofit Kit Installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. Risque de choc électrique. Couper le courant avant de réparer ou installer le produit. LED Retrofit Kit d'installation nécessite la connaissance des systèmes luminaires électriques. Si vous n'êtes pas qualifié, ne tentez pas l'installation. Contactez un électricien qualifié. Installez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions figurant sur les photographies et / ou des dessins.
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
1 Connect LED Driver - Output
· For retrofit, place LED driver in the location where the ballast was formerly located. · Make output (DC) connections as noted below: Using the wiring diagram in step 3, connect the LED Driver output leads to the LED Light leads using wire connectors or other connection method approved for low temperature usage and solid conductors. A For Retrofit: Bundle and safely secure any unused wires by way of approved wire ties and wire connectors.
2 Connect LED Driver - Input
· Make input (AC) connections as noted below. · The LED Driver is required to be reliably bonded to the protective ground conductor. B Mount the LED Driver to a grounded metal portion of the door frame, connect the LED driver housing to an existing equipment grounding conductor, or run an equipment grounding conductor to the equipment grounding terminal. Using the wiring diagram in step 3, connect the original Line and neutral wires (or Line 1 and Line 2 wires for 277 maximum VAC) to the LED Driver leads using wire connectors or other connection method approved for low temperature usage and solid conductors. C

WARNING / AVERTISSEMENT
Risk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. Risque de choc électrique. S'assurer que les points de raccordements sont scellés pour emplacement humide en employant une méthode permise par le NEC ou par le code électrique local.
CAUTION / ATTENTION
Risk of injury. Do not overload LED Driver, 60-watts maximum per driver. Do not exceed the LED light bar loading limits specified on the light bar installation instructions for a 60W driver. Risque de blessure. Ne pas surcharger l'alimentation à DEL. Maximum de 60 watts par alimentation. Ne pas excéder les limites de charge maximale des alimentations telles que spécifiées dans les instructions d'installation.
2

ImmersionTM GELP24-100U-GLX Driver
3 Connection Configurations
For information on A, B, C, see Steps 1 and 2. Refer to LED Light Bar installation instructions for LED light bar wiring configurations.

Installation Guide
Typical Installation

LED LIGHT LOAD

Remote Mounting Distance

100W Power Supply

18 AWG/0.82 mm2 Supply Wire
20 ft./6.1 m

16 AWG/1.31 mm2 Supply Wire
25 ft./7.6 m

TERMINAL BLOCK (AC SOURCE)

14 AWG/2.08 mm2 Supply Wire
35 ft./10.6 m

12 AWG/3.31 mm2 Supply Wire
40 ft./12.1 m

Troubleshooting

Symptom All LED lights are OFF
Some LEDs appear dim Some of the LED lights are not illuminated

Solution
· The GELP24-100UGLX features a new built in output overload shutdown feature that automatically
resets when the AC supply is removed and reapplied. So if all LED lights are off, first verify whether or not the output can be reset by first switching off then switching back on the AC supply. If the LED lights do not re-light, then proceed to the following solutions.
· Check AC input connection and/or check circuit breaker. · Check wire connection(s) at the LED System and power supply for improper termination(s) or short
circuits. Properly terminate or replace the wire connection(s).
· Check that connections are the (+) wire of the LED light to the (+) wire of the power supply and the (-)
wire of the LED light to the (-) wire of the power supply.
· Ensure the overall LED load does not exceed the maximum load. If so, remove the excess load, and
cycle the AC supply to reset the drivers built in overload protection.
· Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
· Check wire connection(s) at the LED light and power supply for improper termination(s) or short circuits.
Properly terminate or replace the wire connection(s).
· Check that connections are the (+) wire of the LED light to the (+) wire of the power supply and the (-)
wire of the LED light to the (-) wire of the power supply.