CW Enerji CWT Solar Panel
BIFACIAL TOPCON MONOCRYSTALLINE 144TNB10
Key Features
- High Conversion Efficiency: Ensures high panel power output.
- Self-Cleaning And Anti-Reflection Glass: Coating reduces surface dust for improved performance.
- Outstanding Low Irradiation Glass: Provides excellent performance even in weak light conditions.
- Excellent Durability: Withstands wind loads up to 2400 Pa and snow loads up to 5400 Pa.
- Positive Power Tolerance: Offers a power tolerance of 0~+5W.
- Easy Installation: Designed for straightforward installation.
Technology Highlights
The panel utilizes 16BB (16 Busbars) n-Type TOPCon technology, featuring a tunneling layer for minority carrier restraint and majority carrier pass, resulting in low resistance loss and high Voc (Open Circuit Voltage).
Warranty Information
CW Enerji provides a 12 Years Product Warranty and a 30 Years Performance Warranty. The linear performance warranty indicates a degradation from 100% at year 0 to approximately 87.4% at year 30, with a step down from 99% to 93.4% between year 12 and year 25.
Available Models
- CWT600-144TNB10: 600 Wp
- CWT605-144TNB10: 605 Wp
- CWT610-144TNB10: 610 Wp
- CWT615-144TNB10: 615 Wp
- CWT620-144TNB10: 620 Wp
Certifications and Standards
Compliant with IEC 61215, IEC 61730-1, IEC 61730-2. Certified under ISO 9001:2015, ISO 14001:2015, ISO 45001:2018.
Also certified by SOMPO, ISO, PV CYCLE, and CE.
Electrical Characteristics
Model Type | CWT600-144TNB10 | CWT605-144TNB10 | CWT610-144TNB10 | CWT615-144TNB10 | CWT620-144TNB10 |
---|---|---|---|---|---|
Peak Power (Pmax) | 600 Wp | 605 Wp | 610 Wp | 615 Wp | 620 Wp |
Module Efficiency | 23.23% | 23.42% | 23.61% | 23.81% | 24.00% |
Maximum Power Voltage (Vmp) | 43.75 V | 43.95 V | 44.15 V | 44.35 V | 44.55 V |
Maximum Power Current (Imp) | 13.72 A | 13.77 A | 13.82 A | 13.87 A | 13.92 A |
Open Circuit Voltage (Voc) | 52.38 V | 52.58 V | 52.78 V | 52.98 V | 53.18 V |
Short Circuit Current (Isc) | 14.42 A | 14.48 A | 14.54 A | 14.60 A | 14.66 A |
Power Tolerance | 0~+5W | ||||
Maximum System Voltage | 1500V DC | ||||
Operating Temperature | -40~+85°C | ||||
Protection Class | Class II | ||||
Maximum Series Fuse Rating | 25A |
Mechanical Specifications
Specification | Value |
---|---|
Cell Dimensions (mm) | 182.2 x 91.8 |
Cells per Module (pcs) | 144 (6x24) |
Weight (kg) | 29.0 |
Panel Dimensions (mm) | 2278 x 1134 x 35 |
Max. Wind/Snow Load (Pa) | 2400 / 5400 |
Junction Box | IP68 |
Junction Box Cable Length (mm) | 300-1600 |
Rearside Power Gain
(Referenced to 620W Front Power)
Specification | 5% | 10% | 15% | 20% | 25% |
---|---|---|---|---|---|
Rear Power Gain (Pmax) | 651 W | 682 W | 713 W | 744 W | 775 W |
Short Circuit Current (Isc) | 15.39 A | 16.13 A | 16.86 A | 17.60 A | 18.33 A |
Open Circuit Voltage (Voc) | 55.84 V | 58.50 V | 61.16 V | 63.82 V | 66.48 V |
Maximum Power Current (Imp) | 14.62 A | 15.31 A | 16.00 A | 16.70 A | 17.40 A |
Maximum Power Voltage (Vmp) | 46.78 V | 49.00 V | 51.23 V | 53.46 V | 55.69 V |
Temperature Characteristics
Characteristic | Value |
---|---|
Temp. Coeff. of (Isc) | +0.040%/°C |
Temp. Coeff. of (Voc) | -0.260%/°C |
Temp. Coeff. of (Pmax) | -0.30%/°C |
Packing Configuration
Configuration | Value |
---|---|
Container | 40' GP |
Pieces Per Pallet | 31 |
Pieces Per Container | 620 |
Pallet Per Container | 20 |
Physical Dimensions
Panel dimensions are 2278mm (length) x 1134mm (width) x 35mm (depth). The frame includes mounting holes (Ø7mm and Ø8mm), grounding holes, and drain holes.
Electrical Performance Curves
The document includes representative current-voltage (I-V) and power-voltage (P-V) curves for the CWT600-144TNB10 model. These curves illustrate the panel's electrical output characteristics under various irradiance levels, ranging from 200 W/m² to 1000 W/m², at standard test conditions.
Important Notes
Specifications are obtained under standard test conditions: 1000 W/m² solar irradiance, 1.5 Air Mass, and cell temperature of 25°C. Measurement uncertainty for all panels is 3%. Actual transactions will be subject to contracts. These parameters are for reference only and not part of contracts. Technical specifications may vary; refer to the "Installation Manual" for more information.
For roof, facade, and similar installations, solar panels must be mounted over a fire-resistant covering with adequate ventilation between the back of the panels and the mounting surface. Improper installations are hazardous and may spark a fire. Solar panels must not be mounted on structures and roofs made of non-fire-resistant materials (e.g., plastic layer, transparent plastic, PVC) without a fire-protection layer. Usage and installation not in accordance with the guidelines in the installation manual will terminate the warranty. Refer to the installation manual and warranty documents for further details.
CW Enerji reserves the right to change product specifications without prior notice.