Installation Guide for Altronix models including: T2SK78D, T3SK7516D, T2SK78D 8 Door Kit with PTC Outputs, T2SK78D, 8 Door Kit with PTC Outputs, PTC Outputs, Outputs
Altronix T3SK7516D | 16-Door House Access and Power Integrat
File Info : application/pdf, 8 Pages, 1.10MB
DocumentDocumentAccess & Power Integration Altronix/Software House Kits Models Include: T2SK78D T3SK7516D 8 Door Kit with PTC Outputs Fully assembled kit includes: - Trove2 enclosure with TSH2 Altronix/Software House backplane - One (1) AL1024ULXB2 - Power Supply/Charger - One (1) ACM8CB - PTC Protected Access Power Controller - One (1) VR6 - Voltage Regulator - One (1) PDS8CB - Dual Input Power Distribution Module - One (1) Rocker Switch Bracket with One (1) Rocker Switch (Not evaluated by UL) 16 Door Kit with PTC Outputs Fully assembled kit includes: - Trove3 enclosure with TSH3 Altronix/Software House backplane - One (1) AL1024ULXB2 - Power Supply/Charger - One (1) AL1012ULXB - Power Supply/Charger - Two (2) ACM8CB - PTC Protected Access Power Controllers - One (1) PD8ULCB - PTC Protected Power Distribution Module - One (1) Rocker Switch Bracket with Two (2) Rocker Switches (Not evaluated by UL) T3SK758D 8 Door Kit with PTC Outputs Fully assembled kit includes: - Trove3 enclosure with TSH3 Altronix/Software House backplane - One (1) AL1024ULXB2 - Power Supply/Charger - One (1) AL1012ULXB - Power Supply/Charger - One (1) ACM8CB - PTC Protected Access Power Controller - One (1) PD8ULCB - PTC Protected Power Distribution Module - One (1) Rocker Switch Bracket with Two (2) Rocker Switches (Not evaluated by UL) All components of these Trove kits are UL Listed sub-assemblies. Please refer to the included corresponding Sub-Assembly Installation Guides for further information. Installation Guide All registered trademarks are property of their respective owners. More than just power.TM Rev. TSKLD120321 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix Trove Software House kits are pre-assembled and consist of Trove enclosure with factory installed Altronix power supply/chargers and sub-assemblies. These kits also accommodate various combinations of Software House boards for up to sixteen (16) doors in a single enclosure. 120VAC 60Hz Input Current (A) Power Supply Board Input Fuse Rating Power Supply Board Battery Fuse Rating 12VDC Output Range (V) 24VDC Output Range (V) 12VDC Output Range (V) 24VDC Output Range (V) 12VDC Output Range (V) 24VDC Output Range (V) 12VDC Output Range (V) 24VDC Output Range (V) Fail-Safe/ Fail-Secure Outputs Current Per ACM8CB Output (A) ACM8CB Board Input Fuse Rating ACM8CB Board Output PTC Rating PDS8CB Board Input PTC Rating PDS8CB Board Output PTC Rating PD8ULCB Board Output PTC Rating Altronix Model Number Configuration Chart: Nominal DC Output Voltage Options Power Supply 1 Power Supply 2 [DC] [AUX] [DC] [AUX] Maximum Supply Current for Main and Aux. Outputs on Power Supply board and ACM8CB Access Power Controller's outputs (A) AL1024ULXB2 N/A T2SK78D 4.5 5A/250V 15A/ 32V 20.1726.4 20.1726.4 24VDC @ 9.2A 8 2.0 10A/ 250V 2A 9A 2A T3SK758D AL1024ULXB2 AL1012ULXB 8.0 5A/250V 15A/ 32V 20.1926.4 20.19- 10.026.4 13.2 10.0313.2 24VDC @ 9.2A 8 2.0 10A/ 250V 2A 2A AL1024ULXB2 AL1012ULXB T3SK7516D 8.0 5A/250V 15A/ 32V 20.1926.4 20.19- 10.026.4 13.2 10.0313.2 24VDC @ 9.2A 16 2.0 10A/ 250V 2A 2A Hardware and Accessories: Metal or Nylon Spacer | 5/16" Pan Head Screw | Lock Nut · Nylon spacers - eighteen (18) for T2SK78D, forty-six (46) for T3SK758D or T3SK7516D. · 5/16" pan head screws - eighteen (18) for T2SK78D, forty-six (46) for T3SK758D or T3SK7516D. · Tamper switch (Altronix Model TS112 or equivalent) - one (1) for T2SK78D, two (2) for T3SK758D or T3SK7516D. · Cam lock. · Battery leads. Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the three upper screws. Fig. 1 Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. Edge of Enclosure Enclosure 4. Mount Software House boards to backplane, refer to pages 3-8. Tamper Switch 5. Refer to the ULXB Power Supply/Charger Installation Guide for AL1012ULXB and AL1024ULXB2 (provided) and corresponding Sub-Assembly Installation Guides for the following models: PD8ULCB, ACM8(CB), PDS8(CB), VR6 for further installation instructions. To Access Control Panel or UL Listed Reporting Device - 2 - Trove Software House ULXB PTC Kits Installation Guide T2SK78D: Configuration of Software House iSTAR Ultra Boards 1. Align the Software House boards on the backplane to match the boards' mounting holes with corresponding pems. 2. Fasten spacers (provided) to pems that match the hole pattern for Software House iSTAR Ultra GCM, iSTAR Ultra ACM, and /or I8, R8, I8-CSI boards (Fig. 2, 2a, pg. 3). 3. Mount Software House boards to spacers utilizing provided 5/16" pan head screws (Fig. 2a, pg. 3). Note: Software House iSTAR Ultra ACM boards have one (1) USB port each. Please orient the board in the appropriate position according to the Fig. 2 below. 4. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 2 + DC - BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + Altronix - AL1024ULXB2 L G N AC DELAY RSB1 Altronix - PDS8CB PWR1 + OFF IN1 IN2 IN1 Fuse PWR1 + Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P COM (--- ) PWR2 + OUT1 N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 COM (--- ) PWR2 + Altronix VR6 is mounted under PDS8CB Software House I8, R8 or I8-CSI Module RJ45 Jack Software House iSTAR Ultra ACM SE USB PORT INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON Altronix - ACM8CB 1234 1234 FACP MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control Trove Software House ULXB PTC Kits Installation Guide Software House iSTAR Ultra GCM Software House iStar Ultra ACM Fig. 2a Pem Spacer Pan Head Screw Power Supply or Backplane Sub-Assembly - 3 - T2SK78D: Configuration of Software House iSTAR Pro Boards 1. Align the Software House boards on the backplane to match the boards' mounting holes with corresponding pems. 2. Fasten provided spacers to pems that match the hole pattern for Software House iSTAR Pro GCM, iSTAR ACM SE/PRO ACM, and /or I8, R8, I8-CSI boards (Fig. 3, 3a, pg. 4). 3. Mount Software House boards to spacers utilizing provided 5/16" pan head screws (Fig. 3a, pg. 4). Note: Software House iSTAR ACM SE/PRO ACM boards have one (1) USB port each. Please orient boards in the appropriate position according to the Fig. 3 below. 4. Fasten backplane to Trove2 enclosure utilizing lock nuts (provided). Fig. 3 + DC - BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + Altronix - AL1024ULXB2 L G N AC DELAY RSB1 Altronix - PDS8CB PWR1 + OFF IN1 IN2 IN1 Fuse PWR1 + Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- P COM (--- ) PWR2 + OUT1 N 1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 2 3 4 5 6 7 Common Power Outputs (NEG) OUT8 8 COM (--- ) PWR2 + Altronix VR6 is mounted under PDS8CB Software House I8, R8 or I8-CSI Module USB PORT INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON Altronix - ACM8CB 1234 1234 FACP MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control - 4 - Software House iSTAR Pro GCM Software House iSTAR Pro ACM Fig. 3a Pem Spacer Pan Head Screw Power Supply or Backplane Sub-Assembly Trove Software House ULXB PTC Kits Installation Guide T3SK758D or T3SK7516D: Configuration of Software House iSTAR Ultra Boards 1. Align the Software House boards on the backplane to match the boards' mounting holes with pems provided. 2. Fasten spacers (provided) to pems that match the hole pattern for Software House iSTAR Ultra GCM, iSTAR Ultra ACM, and /or I8, R8, I8-CSI boards (Fig. 4, 4a, pg. 5). 3. Mount Software House boards to spacers utilizing provided 5/16" pan head screws (Fig. 4a, pg. 5). Note: Software House iSTAR Ultra ACM boards have one (1) USB port each. Please orient the board in the appropriate position according to the Fig. 4 below. 4. Fasten backplane to Trove3 enclosure utilizing lock nuts (provided). Fig. 4 + DC - RSB2 L G N Altronix - AL1024ULXB2 AC DELAY BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + Software House iSTAR Ultra GCM - DC + AC DC Altronix - AL1012ULXB + BAT - LG N BAT FAIL NC C NO NC C NO AC FAIL INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON Altronix - ACM8CB 1234 1234 FACP MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 Software House iSTAR Ultra ACM USB PORT RJ45 Jack Software House iSTAR Ultra ACM USB PORT -+-+ Power Control Altronix - PD8ULCB (T3SK758D) Altronix ACM8CB (T3SK7516D) N P Altronix - PD8ULCB (T3SK7516D) P FUSED POWER OUTPUTS N COMMON POWER OUTPUTS INPUT N P -+-+ Power Control RJ45 Jack Software House I8, R8 or I8-CSI Module Dashed Line indicates pre-wired kit for T3SK758D Dashed Line indicates pre-wired kit for T3SK7516D Software House iSTAR Ultra ACM SE Software House iSTAR Ultra ACM SE Software House I8, R8 or I8-CSI Module Trove Software House ULXB PTC Kits Installation Guide Fig. 4a Pem Spacer Pan Head Screw Power Supply or Backplane Sub-Assembly - 5 - T3SK758D or T3SK75FD: Configuration of Software House iSTAR Pro Boards 1. Align the Software House boards on the backplane to match the boards' mounting holes with pems provided. 2. Fasten provided spacers to pems that match the hole pattern for Software House iSTAR Pro GCM, iSTAR ACM SE/PRO ACM, and /or I8, R8, I8-CSI boards (Fig. 5, 5a, pg. 6). 3. Mount Software House boards to spacers utilizing provided 5/16" pan head screws (Fig. 5a, pg. 6). Note: Software House iSTAR ACM SE/PRO ACM boards have one (1) USB port each. Please orient the board in the appropriate position according to the Fig. 5 below. 4. Fasten backplane to Trove3 enclosure utilizing lock nuts (provided). Fig. 5 + DC - BAT FAIL NC C NO NC C NO AC FAIL AC DC - BAT + RRSSBB22 L G N Altronix - AL1024ULXB2 AC DELAY - DC + AC DC Altronix - AL1012ULXB + BAT - LG N BAT FAIL NC C NO NC C NO AC FAIL INTERFACE NO C NC +INP- T + RET- TRIGGER INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND 1 2 3 4 5 6 7 8 F1 F2 F3 F4 F5 F6 F7 F8 FACP TRG ON ON Altronix - ACM8CB 1234 1234 FACP MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 OUTPUT 6 OUTPUT 7 OUTPUT 8 -+-+ Power Control Altronix - PD8ULCB (T3SK758D) Altronix ACM8CB (T3SK7516D) N P -+-+ Power Control Altronix - PD8ULCB (T3SK7516D) P FUSED POWER OUTPUTS N COMMON POWER OUTPUTS INPUT N P Dashed Line indicates pre-wired kit for T3SK758D Dashed Line indicates pre-wired kit for T3SK7516D - 6 - Software House iSTAR Pro GCM USB PORT Software House iSTAR Pro ACM USB PORT Software House iSTAR Pro ACM Software House I8, R8 or I8-CSI Module Software House I8, R8 or I8-CSI Module Fig. 5a Pem Spacer Pan Head Screw Power Supply or Backplane Sub-Assembly Trove Software House ULXB PTC Kits Installation Guide T2SK78D Enclosure Dimensions (H x W x D approximate): 27.25" x 21.5" x 6.5" (692.2mm x 552.5mm x 165.1mm) 2.00" (50.8mm) 21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm) 2.00" (50.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 1.5" (38.1mm) 0.5625" (14.3mm) 0.685" (17.4mm) 1.77" (45mm) Knockouts 1.125" (28.3mm) 2.415" (61.3mm) 0.885" (22.5mm) 19.80" (502.9mm) 2.00" (50.8mm) 6.75" (171.5mm) 8.25" (209.5mm) 27" (685.8mm) 8.00" (203.2mm) 1.00" (25.4mm) 0.85" (21.6mm) 1.25" (31.8mm) 2.00" (50.8mm) 2.00" (50.8mm) 5.25" (133.4mm) 7.00" (177.8mm) 5.25" (133.4mm) 1.25" (31.8mm) 2.00" (50.8mm) Trove Software House ULXB PTC Kits Installation Guide - 7 - 2.00" (50.8mm) T3SK758D and T3SK7516D Enclosure Dimensions (H x W x D approximate): 36.12" x 30.125" x 7.06" (917.5mm x 768.1mm x 179.3mm) 2.00" (50.8mm) 1.25" (31.8mm) 7.12" (222.3mm) 9.5" (241.3mm) 9.5" (241.3mm) 1.78" (45.2mm) 1.55" (39.4mm) 1.25" (31.8mm) 1.07" (27.2mm) 30.12" (768.1mm) 14.01" (355.9mm) 14.01" (355.9mm) 2" (50.8mm) 1.10" (27.9mm) G G 10.75" (273.1mm) 10.75" (273.1mm) 10.62" (269.8mm) 36.12" (917.5mm) 33.63" (854.2mm) 10.62" (269.8mm) 10.75" (273.1mm) 10.75" (273.1mm) 1.25" (31.8mm) 2" 8.75" (222.3mm) (50.8mm) 8.62" (219mm) 8.75" (222.3mm) 7.06" (179.3mm) 1.25" (31.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITroveSH ULXB Kit D Series L03U MEMBER - 8 - Trove Software House ULXB PTC Kits Installation Guide