Instruction Manual for Danfoss models including: VCM 10 Non Return Valve, VCM 10, Non Return Valve, Valve

VCM 10 and VCM 13 Disassembling and Assembling

PDF preview unavailable. Download the PDF instead.

AX329941721130en-000201
Service guide
Non-return valve VCM 10 / VCM 13 Disassembling and Assembling

The Service guide covers the instruction for disassembling and assembling the VCM 10 and VCM 13 Non-return valve.
IMPORTANT: It is essential that the VCM 10 and VCM 13 are serviced in conditions of absolute cleanliness.
WARNING: Do not use silicone when assembling the VCM 10 and VCM 13. Do not reuse disassembled O-rings; they might be damaged. Always use new O-rings.
For a better understanding of the VCM 10 and VCM 13 , please see the sectional view.
Tools needed: · Snap ring pliers · Screwdriver

Disassembling

1. Mount the VCM10 / VCM 13 into a vice with aluminum trays.

2. Turn the nut CCW with snap ring pliers.

© Danfoss | DCS (im) | 2021.03

180R9421 | AX329941721130en-000201 | 1

Service guide | Disassembling and Assembling VCM 10 and VCM 13

3. Remove the nut.

4. Remove the spring.

5. Remove the valve cone.

6. Remove the O-ring at the cone with a small screw driver.

7. Remove the O-ring at the thread end of the valve with a small screw driver.

© Danfoss | DCS (im) | 2021.03

180R9421 | AX329941721130en-000201 | 2

Service guide | Disassembling and Assembling VCM 10 and VCM 13 Assembling

1. Lubrication: · To prevent seizing-up, lubricate threads
with PTFE lubrication type. · O-ring inside VCM 10 / VCM 13 may be
lubricated only with clean filtered water. · O-rings at the thread end must be
lubricated. · It is important to lubricate ALL parts to
be assembled with clean filtered water.

2. Mount the lubricated O-ring at the thread end of the valve.

3. Mount the water lubricated O-ring on the cone. Ensure the O-ring is pushed fully into the O-ring groove.

4. Mount the cone.

5. Mount the spring onto the cone.

6. Lubricate the threads of the nut.

© Danfoss | DCS (im) | 2021.03

180R9421 | AX329941721130en-000201 | 3

Service guide | Disassembling and Assembling VCM 10 and VCM 13

7. Screw in the nut.

8. Tighten the nut with a snap ring pliers.

9. Lubricate the threads at the valve end.
Testing valve function: Verify free movement of valve cone.

© Danfoss | DCS (im) | 2021.03

180R9421 | AX329941721130en-000201 | 4

Spare part list and sectional drawing

Spare part list Service interval

Pos. Qty. Designation 5 1 O-ring 19.20 x 3.00 6 1 O-ring 40.00 x 2.00
4 years for inspection and exchanging O-rings as needed.

Material
NBR NBR

Seal set 180H4003
x
x

Danfoss A/S High Pressure Pumps Nordborgvej 81 DK-6430 Nordborg Denmark
© Danfoss | DCS (im) | 2021.03

180R9421 | AX329941721130en-000201 | 5


Danfoss A/S GPL Ghostscript 9.55.0