User Manual for Sunco models including: DL SL3-8W-27K 5K 3 Inch Ultra Slim Selectable Downlight, DL SL3-8W-27K 5K, 3 Inch Ultra Slim Selectable Downlight, Slim Selectable Downlight, Selectable Downlight, Downlight

View

Installation Guides, Manuals, and Specs | Sunco – Sunco Lighting

Installation Manual (PDF)

Sunco 24 Pack 3 Inch Ultra Thin LED Recessed Ceiling Lights, Selectable CCT, 2700K/3000K/3500K/4000K/5000K, Dimmable, 8W, Wafer Thin, Canless with Junction Box

PDF preview unavailable. Download the PDF instead.

DL SL3-8W ManualMasterCopy ?v=1705516727
Lighting made better.
User Manual
3" Ultra-Slim Selectable Downlight
SKU: DL_SL3-8W-27K_5K
support @sunco.com (844) 334-9938

AMERICAN COMPANY

Whats in the Box? Slim Downlight

Why Plastic Junction Boxes? At Sunco, our commitment to safety and reliability is at the core of our lighting solutions, ensuring your peace of mind.
Plastic's corrosion resistance ensures longer product lifespans with minimal maintenance.
Plastic junction boxes are non-conductive, significantly helping prevent potential fires.
Plastic junction boxes feature smooth edges, minimizing accidental cuts.
No need for a ground wire

x1 Light Fixture
Get Your Gear

x1 Junction Box

x1 Installation Template

x2 Wire Nuts

Tape

Hole Saw 1

Ladder

Wire Strippers

Before You Start

Safety Information

To reduce the risk of fire, electric shock, or physical injury:

· Turn off circuit breaker before installing this

ranging from 4°F to 113°F. Not for use where

fixture.

directly exposed to water.

· Professional installation required. Safety gear · Clean the fixture regularly to ensure proper

recommended.

operation. Do not clean with harsh solvents.

· Abide by regional and local laws or regulations. · Use safety precautions and abide by regional

· Proper grounding is required to ensure safety. · Do not alter, or remove wiring during
installation. · Do not make or alter any open holes in wiring
enclosure or electrical components during installation. · Check for shipping damage before insatalling.
If the product is damaged, do not use it. · Keep fixture away from corrosive substances.

and local laws or regulations. · This product is not compatible with 3rd party
sensors. · This product is not compatible with photo
controls. · This product is not compatible with occupancy
sensors. · This product is not compatible with timing
devices.

· Suitable for damp locations at temperature

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.) This device may not cause harmful interference.

2.) This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.

Quickstart Guide

1 2

2

Installation Guide
3.5"
Knockout

STEP 1 a. Turn off circuit breaker before installation. b. Cut out 3.5" housing size on Installation Template, then tape onto ceiling in desired location. c. Cut ceiling hole using Installation Template as a guide.
STEP 2 a. Open junction box and remove appropriate knockout.
STEP 3 a. Connect supply and junction wires using wire nuts: -Black to Black (Live) -White to White (Neutral) b. Tuck connected wires inside junction box & close cover.
3

Installation Guide (Cont.)

STEP 4

On back of junction box, slide the CCT Switch

6000K

5000K 4000K 3000K

to choose from 5 color temperatures. Insert

2700K

junction box through ceiling hole.

NOTE: Junction box should be secured to

studs, joists, or similar fixed structural units.

1 2

STEP 5 a. Attach fixture to junction box using connector as shown on image (1). Tighten connector by hand (2).
b. Push up spring clips and insert fixture into ceiling. Turn on circuit breaker and test light.

STEP 6 a. Push up spring clips and insert fixture into ceiling.
b. Turn on circuit breaker and test light.

4

Product Details

Recommended Dimmers

Brand
LUTRON LUTRON LUTRON LUTRON LUTRON LEVITON KASA SMART KASA SMART

Model
P-PKG1WB-WH MACL-153M-WH PD-6WCL-WH AYCL-153P-WH DVCL-153P-WH D26HD-2RW HS220 HS220P3

Sccaonmfpoarttihbleefduillmmer list!

Voltage

120V

Wattage

8W

Wattage Equivalency 45W

Beam Angle

90°

Weight

0.35lbs

Housing Material

Plastic

Dimmable

Yes

Average Lifetime Lumens Moisture Rating CRI Usage IC Rated Warranty

50,000 hrs 500LM Damp 90+ Indoor Yes 7 Years

5

Common Troubleshooting
Need help? Our troubleshooting section is here to help.

Contact us for expert assistance and brighten your day!

Light isn't turning on. Light isn't bright enough.

Double check if fixture is properly connected and circuit breaker hasn't been tripped.
Check proper wattage and for unobstructed fixture.

Light not dimming to lowest setting.

Ensure minimum dimmer load requirement met.

Light not dimming smoothly.

Verify dimmer compatibility with fixture.

Light not compatible with dimmer switch.

Check light-dimmer compatibility.

Light is flickering when turning on.

Check that fixture wiring connections secure.

Light flickering with other lights on same circuit. Check that lights are not overloading the circuit.

Light flickering when turned on.

Verify fixture compatibility and that it is grounded.

Light flickering when dimmed.

Verify dimmer switch compatibility.

Fixture buzzing with power outages. Fixture buzzing with appliances. Fixture buzzing when dimmed.

Verify light is connected to surge protector.
Look for nearby interferences that can cause buzzing. Such as televisions, radios, etc.
Verify dimmer switch compatibility.

6

Light Distribution Angle

Not No

wa olrirgihetsi, nygounecradn?

skip

this

page

AVERAGE BEAM ANGLE (50%): 92.6 DEG C0/180 88.0° C90/270 97.2°
UNIT:cd Luminous Intensity Distribution 1

Lighting distribution angle refers to the
spread of light emitted from a light source.
It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two
main types of lighting distribution angles: A
symmetric lighting distribution emits light evenly in all directions, creating a coneshaped pattern that provides a pool of light. This type of lighting is ideal for general light-
ing and illuminating large areas. Common
applications for symmetric lighting include

general area illumination, security lighting,
and perimeter lighting. Symmetric lighting is
also used to a certain degree in up-lighting.
An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail
stores, museums, and much more.

7

Customer Support

Warranty Policy
This product is covered by our industry leading 7 year warranty. It gets even better - scan the QR code for 2 extra years of protection!

Secxatnramyeeafrosr! two

30 Day Return Policy

At Sunco we value our customers and stand by the quality and performance of our products.

If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.

Customer Service

Our team of lighting experts is here to assist you with all your needs! Contact us at:

Email: support@sunco.com

Text or Call: (844) 334-9938 6AM - 6PM PST Monday - Friday

8

Lighting made better.

support @sunco.com (844) 334-9938

REV1.0

AMERICAN COMPANY


Adobe PDF Library 17.0 Adobe InDesign 18.0 (Windows)