Texecom Premier Elite ComPort+
INSTALLATION INSTRUCTIONS
INS664
Introduction
The Premier Elite ComPort+ plugs into the onboard digi connector on Premier Elite 12/24/48/88 & 168 control panels allowing use of Com Port 3.
Note: Premier Elite 640 already has Com port 3.
V3 firmware is required to enable the device, which when used allows connection of any device listed in the Com 3 dropdown menu, or connection to a local PC via a USBCom for upload/download capability.
PCB Layout and Connections
The figure below shows the PCB layout of the Premier Elite ComPort +:
[Diagram: PCB layout with labels BARCODE, JP1, JP2. JP1 is labeled 'ComPort 3 Device or USBCom'. JP2 is labeled 'Digi Pins Connection (SELV)']
Premier Elite ComPort + Installation
To install the Premier Elite ComPort + proceed as follows:
- Ensure that all power is removed from the control panel before connecting the Premier Elite ComPort +.
- Plug the Premier Elite ComPort + onto the 10 way onboard digi pins on the control panel.
- Re-apply power to the system and proceed to the next section.
[Diagram: PCB layout of the Premier Elite 168 control panel showing connections and labels like BARCODE, JP1, JP2, OP1-, OP1+, OP2-, OP3+, OP4+, SPK, SPK+, FE, Aux/Fault, +12v, GND, NO, NC, C]
Programming the Control Panel
The control panel will then need to be programmed correctly in order for the Premier Elite ComPort + to function as expected:
Programme Premier Elite ComPort +
- Enter the engineer code [engineer code].
- Press [Yes] then [Yes] (UDL/Digi Options).
- Press [Yes] then [Yes] for (Com Port Setup/Onboard Digicom).
- Press [No/X] then [0] to select Nothing Fitted.
- Press [Yes].
USBCom
If the Premier Elite ComPort + is being used simply for local connection of a laptop, no further programming is required. The device will allow connection to the control panel from a local PC.
ComPort 3
If the Premier Elite ComPort + is being used to enable Com 3 for one of the optional devices listed on Com 3, it should be programmed in the same manner as Com 1 or 2. Please see the Premier Elite Installation Manual INS176 for detailed instructions.
Specifications
Supply Voltage: | 9-16VDC |
Current Consumption: | <1mA + the connected device |
Dimensions: | 40mm x 30mm x 10mm |
Packed Weight: | 25g |
Texecom declares that this product complies with the requirements of the following directives:
- 2004/108/EC EMC Directive
- 2006/95/EC LVD Directive
- 2011/65/EU ROHS Directive
The product therefore meets all the requirements to enable it to be CE marked.
[Symbol: Crossed-out wheelie bin] Weee Directive: 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.
This product is suitable for use in systems designed to comply with EN 50131-1, at Grade 2 and Environmental Class II.
Warranty
All Texecom products are designed for reliable, trouble-free operation. Quality is carefully monitored by extensive computerised testing. As a result the Premier Elite ComPort + is covered by a two-year warranty against defects in material or workmanship.