European Home Trisore 140 3-Sided Fireplace
Manufacturer and Importer of high-end Gas, Wood and Electric Fireplaces
ELEMENT 4: Dutch designs imported from the Netherlands
Specifications
GAS TYPE | Natural Gas or Propane |
BURNER | Double Burner |
HEAT OUTPUT (NATURAL GAS) | 13,650-38,200 BTU/hr |
HEAT OUTPUT (LIQUID PROPANE) | 11,950-34,100 BTU/hr |
VIEWABLE OPENING | 54 7/16" W x 16 16" H |
WEIGHT | 285 lbs. |
VENTING | Requires 5" x 8" Direct Vent |
FLAME ADJUSTMENT | Yes |
INTERIOR | Black Anthracite (Standard) |
REMOTE CONTROL | Yes |
ELECTRIC IGNITION | Yes |
CERTIFICATION | ANSI Z21.11.50a-2008, CSA 2.22a-2008, CSA P.4 - Vented Gas Fireplaces |
MASS APPROVAL CODE | G3-0219-3 |
EFFICIENCY | 90% |
Product Options & Accessories
Double Burner System
PRODUCT | ITEM CODE |
TRISORE 140 | E4-TRI-140-KIT |
Propane (LP) Conversion Kit
PRODUCT | ITEM CODE |
140 Double Burner | E4-SA-LPCK-2-02 |
Convection Air Opening Trims
PRODUCT | ITEM CODE |
Opening Size 8" x 1.75" Frame Size 10.5" x 3.75" | E4-SA-PF-CAOT-8-02 |
Opening Size 10" x 2.5" Frame Size 12" x 4.5" | E4-SA-PF-CAOT-10-03 |
Opening Size 11" x 3" Frame Size 12.5" x 4.5" | E4-SA-PF-CAOT-11-03 |
Opening Size 11" x 5.5" Frame Size 13" x 7.5" | E4-SA-PF-CAOT-11.5-02 |
Opening Size 20" x 1.75" Frame Size 22" x 3.75" | E4-SA-PF-CAOT-20-03 |
Opening Size 25" x 2" Frame Size 27" x 4" | E4-SA-PF-CAOT-25-03 |
Opening Size 34" x 1.75" Frame Size 36" x 3.75" | E4-SA-PF-CAOT-34-02 |
Opening Size 36" x 1.75" Frame Size 38" x 3.75" | E4-SA-PF-CAOT-36-03 |
Opening Size 38" x 2.5" Frame Size 40" x 4.5" | E4-SA-PF-CAOT-38-02 |
Opening Size 40" x 1.75" Frame Size 42" x 3.75" | E4-SA-PF-CAOT-40-03 |
Opening Size 50" x 2" Frame Size 52" x 4" | E4-SA-PF-CAOT-50-02 |
Fire Media - Landscape Series
PRODUCT | ITEM CODE |
FALLEN BIRCH | E4-FM-FB-418a |
FOREST PATH | E4-FM-FP-418 |
LOG SET | E4-LSE-418 || |
TUNDRA | E4-FM-TN-418 |
Fire Media - Classic Series
PRODUCT | ITEM CODE |
BLACK QUARTZ | E4-STBGE4-14 |
BRILLIANTS | E4-STDE4-15 |
CARRARA PEBBLES | E4-STC4-3 |
GRAY STONES | E4-FM-GS-8 |
Interior Black Reflective Panels
PRODUCT | ITEM CODE |
For 140 Models | E4-CP-BG-TRI-140 |
Interior Concrete Style Panels
PRODUCT | ITEM CODE |
For 140 Models | E4-CP-CON-140-3S |
Misc Accessories
PRODUCT | ITEM CODE |
Home Automation Cable | E4-SA-SHSC-02 |
Wi-Fi Enabling Kit | E4-GS-Wifi |
Puck Smart Control | E4-GS-PUCK-02 |
Dealer Service Case | E4-SVC-Case-02 |
Cut Sheet
Diagrams illustrating dimensions and measurements for the Trisore 140 fireplace.
LETTERS | A | B | C | D | E | G | H | I | K | L | M | O |
---|---|---|---|---|---|---|---|---|---|---|---|---|
INCHES [MILLIMETERS] | 54 7/16 [1383] | 4 7/16 [420] | 1 11/16 [170] | 58 1/16 [1497] | 26 5/8 [674] | 50 3/4 [1280] | 15 5/16 [389] | 4 11/16 [119] | 29 1/8 [740] | 13 1/2 [330] | 1 1/8 [13] | 11 5/8 [295] |
Venting Charts
3.2 Category 2 (Imperial) - Ratio 1:2.5
The tables below are the same for fireplaces with vent collar diameter 5/8 and 4/6. Fireplaces in this category are never to be reduced to ensure a correctly functioning fireplace.
3.2.1 Calculation table horizontal termination
A visual representation of venting requirements based on total vertical and horizontal lengths.
3.2.2 Calculation table vertical termination
For a vertical termination a minimal starting length of 20" before an elbow and minimal Total Vertical Length of 3' is required.
Key:
- R: Air Restrictor Required
- V: Air Restrictor Not Required
- X: Can Not Have That Vent Run
Venting Clearances
Horizontal Vent Termination Clearances and Requirements
Note: Local Codes Or Regulations May Require Different Clearances. Note: Location Of The Vent Termination Must Not Interfere With Access To The Electrical Service.
Diagrams illustrating horizontal vent termination clearances.
US Installation** | Canadian Installation* | |
---|---|---|
A = Clearance above grade, veranda, porch, deck, or balcony. | 12 inches (30cm)** | 12 inches (30cm)* |
B = Clearance to window or door that may be opened. | 6 inches (15cm) for appliances < 10,000 Btuh (3kW), 9 inches (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12 inches (30cm) for appliances > 50,000 Btuh (15kW)** | 6 inches (15cm) for appliances < 10,000 Btuh (3kW), 12 inches (30cm) for appliances > 10,000 Btuh (3kW) |
C = Clearance to permanently closed window | 9 inches (229mm) recommended to prevent window condensation | 12 inches (305mm) recommended to prevent window condensation |
D = Vertical clearance to ventilated soffit located above the termination within a horizontal distance of 18 inches (458mm) from the center line of the termination | 18 inches (458mm) | 18 inches (458mm) |
E = Clearance to unventilated soffit | 12 inches (305mm) | 12 inches (305mm) |
F = Clearance to outside corner | 5 inches (12.7cm) minimum | 5 inches (12.7cm) minimum |
G = Clearance to inside corner | 2 inches (5.08cm) minimum - SV4.5HT-2 | 2 inches (5.08cm) minimum - SV4.5HT-2 |
H = Clearance to each inside of center line extended above meter/regulator assembly | 3 feet (91cm) within a height of 15 feet above the meter/regulator assembly** | 3 feet (91cm) within a height of 15 feet above the meter/regulator assembly* |
I = Clearance to service regulator vent outlet | 3 feet (91cm)** | 3 feet (91cm)* |
J = Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance | 6 inches (15cm) for appliances < 10,000 Btuh (3kW), 9 inches (23cm) for appliances > 10,000 Btuh (3kW) and < 50,000 Btuh (15kW), 12 inches (30cm) for appliances > 50,000 Btuh (15kW)** | 6 inches (15cm) for appliances < 10,000 Btuh (3kW), 12 inches (30cm) for appliances > 10,000 Btuh (3kW) |
K = Clearance to a mechanical air supply inlet | 6 feet (1.83m)** | 6 feet (1.83m)* |
L = Clearance above paved sidewalk or paved driveway located on public property | 7 feet (2.13m)‡ | 7 feet (2.13m)‡ |
M = Clearance under veranda, porch, deck or balcony | 12 inches (30cm)*‡ | 6 inches (15.2mm)* |
N = Depth of Alcove (Maximum) | 6 inches (15.2mm)** | 12 inches (30cm)‡ |
O = Clearance to Termination (Alcove) | 3 feet (91cm)* | 6 feet (1.83m)** |
P = Width of Alcove (Minimum) | 18 inches (457mm)** | 18 inches (457mm)* |
Q = Clearance to Combustible Above (Alcove) |
* In accordance with the current CSA-B149.1 National Gas And Propane Installation Code.
** In accordance with the current ANSI SZ223.1/NFPA 54 National Fuel Gas Codes.
+ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.
*‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor:
Vertical Termination Clearances and Requirements
Important Note for Roof Terminations
These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1 in the USA) or the current standard of CAN/CSA-B149.1 in Canada.
Diagram illustrating vertical vent termination clearances.
Roof Pitch | * Feet | * Meters |
---|---|---|
Flat to 6/12 | 1.0 | 0.3 |
6/12 to 7/12 | 1.25 | 0.38 |
7/12 to 8/12 | 1.5 | 0.46 |
8/12 to 9/12 | 2.0 | 0.61 |
9/12 to 10/12 | 2.5 | 0.76 |
10/12 to 11/12 | 3.25 | 0.99 |
11/12 to 12/12 | 4.0 | 1.22 |
12/12 to 14/12 | 5.0 | 1.52 |
14/12 to 16/12 | 6.0 | 1.83 |
16/12 to 18/12 | 7.0 | 2.13 |
18/12 to 20/12 | 7.5 | 2.29 |
20/12 to 21/12 | 8.0 | 2.44 |
The vent / air intake termination clearances above the high side of an angled roof is as shown in the following chart:
A second termination may be no closer than 12"/305 mm.
Diagram illustrating multiple termination clearance.
Related Documents
![]() |
European Home Cool Wall Installation Guide for Vent-Free Fireplaces This guide details four installation methods developed by European Home to ensure the wall above their H Series vent-free fireplaces remains cool enough for mounting electronics like televisions. It covers protecting electronics, deep mantel installations, recessed TV options, and double front wall methods, emphasizing design flexibility and heat output. |
![]() |
EuropeanHome H Series 3-Sided Gas Fireplace Specifications and Options Detailed specifications, product options, accessories, and dimensional cut sheets for the EuropeanHome H Series 3-Sided gas fireplace models. |
![]() |
EuropeanHome Gas Stones Natural Vent Burner Product Information Specifications, product options, accessories, and dimensions for the EuropeanHome Gas Stones Natural Vent Burner, available in Natural Gas and Liquid Propane models. |