Installation Guide for Altronix models including: TROVE T2MK7F8PQ 8 Door Kit with Fused Outputs, TROVE T2MK7F8PQ, T2MK7F8PQ, 8 Door Kit with Fused Outputs, 8 Door Kit, Fused Outputs
Altronix T2MK7F8PQ | 8-Door Access and Power Integration Kit
File Info : application/pdf, 4 Pages, 721.33KB
DocumentDocumentAccess & Power Integration T2MK7F8PQ 8 Door Kit with Fused Outputs Fully assembled kit includes: - Trove2 enclosure with TM2 Altronix/Mercury backplane - One (1) eFlow104NB - Power Supply/Charger - One (1) LINQ8PD - Fuse Protected Networked Power Distribution Module - One (1) VR6 - Voltage Regulator - One (1) PDS8 - Dual Input Fuse Protected Power Distribution Module Installation Guide All registered trademarks are property of their respective owners. More than just power.TM Rev. 080118 Installing Company: _________________________ Service Rep. Name: __________________________________________ Address: _________________________________________________________ Phone #: _________________________ Overview: Altronix T2MK7F8PQ Trove Mercury kit is pre-assembled and consists of Trove2M2 enclosure with factory installed Altronix power supply/charger and sub-assemblies. T2MK7F8PQ kit also accommodates various combinations of Mercury boards for up to eight (8) doors in a single enclosure. Altronix Model Number T2MK7F8PQ 120VAC 60Hz Input Current (A) 4.5 Power Supply Board Input Fuse Rating 6.3A/ 250V Power Supply Board Battery Fuse Rating 15A/ 32V Configuration Chart: Nominal DC Output Voltage [DC] [Aux] Maximum Supply Output Output Current for Main and Range Range Aux. Outputs on (VDC) (VDC) Power Supply Board 20.19- 20.1926.4 26.4 24VDC @ 9.2A LINQ8PD Board Input Fuse Rating 15A/32V LINQ8PD Board Output Fuse Rating 3A/32V PDS8 PDS8 Board Board Input Output Fuse Fuse Rating Rating 10A/ 3A/ 32V 32V Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Mark and predrill holes in the wall to line up with the top two/three keyholes in the enclosure. Install two/three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure's upper keyholes over the two/three upper screws; level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper keyholes over the two/three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the Fig. 1 enclosure approximately 2" from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate Enclosure UL Listed reporting device. To activate alarm signal open the door of the enclosure. 4. Mount Mercury modules to backplane(s), refer to page 3. 5. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow104NB Edge of Enclosure and corresponding Sub-Assembly Installation Guides for Tamper Switch LINQ8PD, PDS8 and VR6 for further installation instructions. (included) Hardware: Snap On Spacer | 5/16" Pan Head Screw | Lock Nut To Access Control Panel or UL Listed Reporting Device - 2 - T2MK7F8PQ Installation Guide T2MK7F8PQ: Configuration of Mercury Boards: 1. Fasten snap on spacers onto metal pems configuration (A), (B), (C) or (D) of backplane depending on the access controller (Fig. 2, pg. 3). 2. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 2a, pg. 3). 3. Mount backplane to enclosure with hardware. Access Controller Position Chart for the Following Models: Mercury Access Controller EP1502, MR52, MR16IN, MR16OUT EP2500, MUX8 EP1501, MR51e MR50 Pem Mounting A B C D Fig. 2 Fig. 2a Altronix - eFlow104NB L G N NC C NO NC C NO AC FAIL BAT FAIL TRIGGER EOL NO GND SUPERVISED RESET +AUX- BAT + DC + C C B A Pem Snap On Spacer Backplane Mercury Board + INP1 - + INP2- +BAT IN- +BAT OUT- BAT NC C AC NC C AC FAIL NC C NC C BAT FAIL Altronix - LINQ8PD Altronix - PDS8 Altronix VR6 is mounted under PDS8 Common Power Outputs (NEG) DM2 + N 1 2 3 4 5 6 7 OUT8 8 Common (--- ) DM2 + Common (--- ) OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 P Out8 <1 off 2> Out7 <1 off 2> Out6 <1 off 2> Out5 <1 off 2> Out4 <1 off 2> Out3 <1 off 2> Out2 <1 off 2> Out1 <1 off 2> IN2 Fuse + INP1 -- + INP2 -- 3 3 3 3 3 3 3 3 10 IN2 IN1 IN1 Fuse 10 DM1 + DM1 + OFF B A C C B A C D D B A T2MK7F8PQ Installation Guide - 3 - Trove2 Enclosure Dimensions (H x W x D approximate): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm) 2.00" (50.8mm) 21.50" (546.1mm) 5.25" (133.35mm) 3.5"(88.9mm) 3.5"(88.9mm) 5.25" (133.35mm) 2.00" (50.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 6.25" (158.8mm) 1.25" (31.8mm) 1.5" (38.1mm) 0.5625" (14.3mm) 0.685" (17.4mm) 1.77" (45mm) Knockouts 1.125" (28.3mm) 2.415" (61.3mm) 0.885" (22.5mm) 19.80" (502.9mm) 2.00" (50.8mm) 6.75" (171.5mm) 8.25" (209.5mm) 27" (685.8mm) 8.00" (203.2mm) 1.00" (25.4mm) 0.85" (21.6mm) 1.25" (31.8mm) 2.00" (50.8mm) 2.00" (50.8mm) 5.25" (133.4mm) 7.00" (177.8mm) 5.25" (133.4mm) 1.25" (31.8mm) 2.00" (50.8mm) Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IIT2MK7F8PQ I29U MEMBER - 4 - T2MK7F8PQ Installation Guide