File Info : application/pdf, 8 Pages, 1,013.88KB

PDF preview unavailable. Download the PDF instead.

?wpdmdl=1381&refresh=65b2d7102d6c71706219280
Quick Start Guide
Ethernet Switch
AS7535-28XB | AS7535-28XBE
Package Contents

www.edge-core.com

1
1. AS7535-28XB/AS7535-28XBE (includes 2 PSUs and 6 fan trays) 2. Rack Mounting Kit--2 brackets and 8 screws 3. Grounding kit--grounding lug, 2 screws, and 2 washers

2

3

4

5

4. (Optional) AC power cord 5. Documentation--Quick Start Guide (this document) and Safety
and Regulatory Information

Overview

1

4

67 8

12

2

9

3

10

5

11

13

1. 2 x DC or AC PSUs

7. BITS/ToD RJ-45 timing ports

2. 2 x 100G QSFP28 ports

8. 10MHz/1PPS I/O

3. 2 x 400G QSFP-DD ports

9. GNSS antenna

4. 24 x 25G SFP28 ports

10. USB Type C storage port

5. Product tag

11. RJ-45 alarm port

6. Management I/O: 1000BASE-T RJ-45, RJ-45 console,

12. 6 x fan trays

Micro-USB console, reset button

13. Grounding screw

Status LEDs

6

7

4

1

2

3

5

1. PSU LED: Green (OK), Amber (fault) 2. QSFP-DD Port LEDs: Blue (400G), Cyan (200G), Green (100G),
Yellow (50G) 3. QSFP28 Port LEDs: Green (100G), Cyan (50G), Magenta (40G),
Blue (25G), Yellow (10G) 4. SFP28 Port LEDs: Blue (25G), Green (10G), Cyan (1G)

FRU Replacement

5. System LEDs: PSU1/2 -- Green (OK), Amber (fault) DIAG -- Green (OK), Orange (fault detected) FAN -- Green (OK), Orange (fault) LOC -- Blinking Blue (OK) ALARM -- Green (OK), Red (alarm)
6. RJ-45 Management Port LEDs: Left (link), Right (activity)
7. BITS/ToD LEDs: Green (valid BITS), Blinking Green (1PPS ToD)

PSU Replacement 1. Remove the power cord.
2. Press the release latch and remove the PSU.
3. Install replacement PSU.

Fan Tray Replacement 1. Loosen the fan tray screw.
2. Pull out and remove the fan tray.
3. Install replacement fan tray.



­ 1 ­

E052023-CS-R02 150200002489A

Installation

Quick Start Guide

Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. Use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty. Avertissement: Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec l'appareil. L'utilisation d'autres accessoires et vis pourrait endommager l'appareil. Les dommages causés par l'utilisation d'accessoires non approuvés ne sont pas couverts par la garantie.
Caution: The device must be installed in a restricted-access location. Attention: L'appareil doit être installé dans un emplacement à accès restreint.
Note: The device has the Open Network Install Environment (ONIE) software installer preloaded, but no software image. Information about compatible software can be found at www.edge-core.com.
Note: The drawings in this document are for illustration only and may not match your particular model.
1 Mount the Device in an EIA-310 Rack

2 Ground the Device

Rear Panel

Side Panel

Verify Rack Ground Ensure the rack is properly grounded and in compliance with international and local standards. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment). Attach Grounding Wire Attach the grounding wire (#14 AWG/1.5 mm2, green with yellow stripe) to the grounding point on the device's rear panel or side panel. Then connect the other end of the wire to rack ground.
Caution: The earth connection must not be removed unless all supply connections have been disconnected. Attention: Le raccordement à la terre ne doit pas être retiré sauf si toutes les connexions d'alimentation ont été débranchées.

3 Connect Power
a. AC Power

1

1. For a 300mm-deep rack, use the four front screw holes to attach each of the brackets to the device with four of the included bracket screws. (For a 280mm-deep rack, use the four recessed screw holes.)
Install one or two AC PSUs in the device, if they are not already installed in the factory. Then connect an external AC power source to the PSUs. b. DC Power

2
2. Use the screws and cage/clip nuts supplied with the rack to secure the device in the rack.

Install one or two DC PSUs in the device, if they are not already installed in the factory.
Connect an external DC power source to the PSUs. Or, connect to a notolerance DC mains supply with a UL/CSA-approved circuit breaker rated at 16 A.

­ 2 ­

Quick Start Guide

Caution: Before connecting power supply cables to the device, ensure that power to the feed lines is turned off at the supply circuit breaker or disconnected from the power bus. Attention: Avant de connecter les câbles d'alimentation à l'appareil, assurez-vous que l'alimentation des lignes d'alimentation est coupée au niveau du disjoncteur d'alimentation ou déconnectée du bus d'alimentation.
Caution: Use a UL/IEC/EN 60950-1 and/or 62368-1 certified power supply to connect to a DC converter, and a #14 AWG/1.5 mm2 (for -44 VDC to -60 VDC PSU) wire to connect to a DC PSU. Attention: Utilisez une alimentation certifiée UL/IEC/EN 60950-1 et/ou 62368-1 pour le connecter à un convertisseur CC et un câble AWG #14/1.5 mm2 (pour -44 VDC à -60 VDC) pour vous connecter à une alimentation CC.
Caution: All DC power connections should be performed by a qualified professional. Attention: Toutes les connexions d'alimentation CC doivent être effectuées par un professionnel qualifié.

The following transceivers are supported in the QSFP28 ports:  100GBASE-SR4, PSM4, LR4, ER4, ZR4, CR4, AOC  40GBASE-SR4, PSM4, LR4
The following transceivers are supported in the SFP28 ports:  25GBASE-SR, LR, BX BiDi  10GBASE-SR, LR, CR, BX BiDi, T  1000BASE-SX, LX, BX BiDi, T
5 Connect Timing Ports

2

3

1

1. Connect the ground wire / protective earth. 2. Connect the -44 ­ -60 VDC wire.
3. Connect the DC return wire.
Note: It is suggested to use the following for DC power: One UL 1015 AWG#10-14 stranded wire, 2m maximum (-44VDC ­ -60VDC: Input+) One UL 1015 AWG#10-14 stranded wire, 2m maximum (VDC return: Input-) One UL 1015 AWG#10-14 stranded wire, 2m maximum, (green/yellow) green with yellow stripe (PE)
Note: The DC terminal screws should be tightened to a torque of 7 in-lbs maximum.
4 Make Network Connections

RJ-45 BITS/ToD Use Cat. 5e or better twisted-pair cables to connect the BuildingIntegrated Timing Supply (BITS) and Time of Day (ToD) ports to other synchronized devices.
10MHz/1pps Use coax cables to connect the 10 MHz and 1-pulse-per-second (1PPS) ports to other synchronized devices.
GNSS Antenna Attach an external antenna to the GNSS antenna port for clock synchronization with GPS time.
6 Make Management Connections

QSFP-DD/QSFP28/SFP28 Ports Install transceivers and then connect fiber optic cabling to the transceiver ports. Alternatively, connect AEC/AOC/DAC cables directly to the QSFPDD/QSFP28/SFP28 slots.
The following transceivers are supported in the QSFP-DD ports:  400GBASE-SR8, DR4, FR4, AEC cable

Mgmt RJ-45 Port Connect Category 5, 5e or better twisted-pair cable.

RJ-45 Console Port Use an RJ-45-to-DB-9 null-modem console cable (not included) to connect to a PC running terminal emulator software. Use a USB-to-male DB-9 adapter cable (not included) for connections to PCs that do not have a DB-9 serial port.

Configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.

Console cable pinouts and wiring:

Device's RJ-45 Console Null Modem PC's 9-Pin DTE Port

6 RXD (receive data)

<---------------- 3 TXD (transmit data)

3 TXD (transmit data)

----------------> 2 RXD (receive data)

4,5 SGND (signal ground) ------------------ 5 SGND (signal ground)

­ 3 ­

Hardware Specifications

Size (WxDxH) 438.4 x 300 x 43.3 mm (17.26 x 11.81 x 1.7 in.)

Weight Temperature

6.8 kg (14.99 lb), with two installed PSUs Operating: -40° C to 65° C (-40° F to 149° F) Transportation: -40° C to 85° C (-40° F to 185° F) Storage: -40° C to 85° C (-40° F to 185° F)

Humidity

Operating: 5% to 95% (non-condensing)

Power Consumption (at 25° C)
System Input Rating

Maximum: 383.6 W Typical: 164.03 W Minimum: 95.11 W
AC Input: 100­240 VAC, 50­60 Hz, 6.0­2.4 A 100-120 VAC, 50/60 Hz, 6.0 A Max or 200-240 VAC, 50/60 Hz, 3.0 A Max DC Input: -44 ­ -60 VDC, 15.5­9.6 A

Regulatory Compliances

Emissions

EN 55032 EN 61000-3-2 EN 61000-3-3 FCC Title 47, Part 15, Subpart B, Class A VCCI-CISPR 32 BSMI Class A

Immunity

EN 55035 IEC 61000-4-2/3/4/5/6/8/11

Environmental

Storage:  ETSI EN 300 019-1-1 Class 1.1  Temperature: -40° C to 85° C (-40° F to 185° F)
Transportation:  ETSI EN 300 019-1-2 Class 2.3  Temperature: -40° C to 85° C (-40° F to 185° F)
Operating Conditions:  ETSI EN 300 019-1-3 Class 3.2  Temperature: -40° C to 65° C (-40° F to 149° F)
 Relative Humidity: 5% to 95%

Safety

UL (CSA 22.2 No 62368-1 & UL 62368-1) CB (IEC/EN 62368-1, 2nd & 3rd Ed) BSMI CNS 15598-1

Quick Start Guide

Warranty Information and Technical Support Registering your product enables you to receive a more efficient warranty service. Be sure to register at www.edge-core.com.
­ 4 ­



AS7535-28XB | AS7535-28XBE



www.edge-core.com

1

2

3

4

5

1. AS7535-28XB/AS7535-28XBE  2  PSU  6  )
2.  --2  8  3.  -- 2  2 

4.  AC  5.  



1

4

67 8

12

2

9

3

10

5

11

13

1. 2 x DC  AC PSU

7. BITS/ToD RJ-45 

2. 2 x 100G QSFP28  3. 2 x 400G QSFP-DD 

8. 10MHz/1PPS I/O 9. GNSS 

4. 24 x 25G SFP28 

10. USB Type C 

5.  6.  I/O1000BASE-T RJ-45RJ-45 
Micro-USB 

11. RJ-45  12. 6 x  13. 

LED 

6

7

4

1

2

3

5

1. PSU LED (OK) 
2. QSFP-DD  LED (400G) (200G) (100G) (50G)
3. QSFP28  LED (100G) (50G) (40G) (25G) (10G)
4. SFP28  LED (25G) (10G) (1G)

 FRU

5.  LED PSU1/2 --    DIAG --    FAN --    LOC --    --   
6. RJ-45  LED  )  ) 7. BITS/ToD LED  BITS) (1PPS ToD)

 PSU 1. 
2.  PSU 3.  PSU

 1. 
2.  3. 

­ 5 ­





   

  #14 AWG/1.5 mm2 


  Open Network Install EnvironmentONIE  www.edge-core.com  

3 
a. AC 

1  EIA-310 

 AC PSU  AC  PSU b. DC  1
1.  300mm   280mm  

2
2.  
2 

 DC PSU  DC  PSU DC  UL/ CSA  16A 
   UL/IEC/EN 60950-1  /  62368-1   DC  #14 AWG/1.5 mm2  -44 VDC  -60 VDC PSU DC PSU  DC 





   

2

3

1

1.  2.  -44 ­ -60 VDC  3.  DC 

­ 6 ­



 DC   UL 1015 AWG#10-14  2m -44VDC ­ -60VDC +  UL 1015 AWG#10-14  2m VDC  -  UL 1015 AWG#10-14  2m  /  (PE)
DC  7 in-lbs 

6 

4 
QSFP-DD/QSFP28/SFP28   AEC/DAC  QSFP-DD/QSFP28/SFP28  QSFP-DD 
 400GBASE-SR8DR4FR4AEC  QSFP28 
 100GBASE-SR4PSM4LR4, ER4ZR4CR4AOC  40GBASE-SR4PSM4LR4 SFP28   25GBASE-SRLRBX BiDi  10GBASE-SRLRCRBX BiDiT  1000BASE-SXLXBX BiDiT
5 

Mgmt RJ-45   Category 55e 
RJ-45   RJ-45-  -DB-9    USB-  -  DB-9    DB-9 
115200 bps8  1  8 


 RJ-45 

  9  DTE 

6 RXD 

<---------------- 3 TXD 

3 TXD 

----------------> 2 RXD 

4,5 SGND  ------------------ 5 SGND 

RJ-45 BITS/ToD  5e  (BITS)   (ToD)  10MHz/1pps  10 MHz  1  (1PPS)   GNSS   GPS  GPS 
­ 7 ­



  x  x 

438.4 x 300 x 43.3 mm (17.26 x 11.81 x 1.7 in.)



6.8 kg (14.99 lb) PSU



-40° C  65° C (-40° F  149° F -40° C  85° C -40° F  185° F -40° C  85° C -40° F  185° F



5%  95% 

 25° C  383.6 W 164.03 W 95.11 W



AC 100­240 VAC50­60 Hz6.0­2.4 A 100-120 VAC50/60 Hz 6.0 A  200-240 Vac50/60 Hz 3.0 A DC -44 ­ -60 VDC15.5­9.6 A

 

EN 55032 EN 61000-3-2 EN 61000-3-3 FCC Title 47, Part 15, Subpart B, Class A VCCI-CISPR 32 BSMI Class A



EN 55035 IEC 61000-4-2/3/4/5/6/8/11



Storage:  ETSI EN 300 019-1-1 Class 1.1  Temperature: -40° C to 85° C (-40° F to 185° F)
Transportation:  ETSI EN 300 019-1-2 Class 2.3  Temperature: -40° C to 85° C (-40° F to 185° F)
Operating Conditions:  ETSI EN 300 019-1-3 Class 3.2  Temperature: -40° C to 65° C (-40° F to 149° F)
 Relative Humidity: 5% to 95%



UL (CSA 22.2 No 62368-1 & UL 62368-1) CB (IEC/EN 62368-1, 2nd & 3rd Ed) BSMI CNS 15598-1



­ 8 ­



References

Adobe PDF Library 15.0