Read this manual carefully and keep it with other warranty documents. Connection must be carried out by a qualified installer in accordance with local regulations. Before installing or disassembling the thermostat, always switch off the electricity in the meter cupboard. This thermostat can be installed in a single flush-mounting box 50 mm deep, according to standard DIN formats.

1. Technical details

Power 90-240Vac 60/60Hz
Max. Load 16A/250V
Floor sensor type 10k NTC 1%
Temp. range 5°C-35°C
Accuracy 0.5°C
Cover IP21
Warranty 2 years

2. Wiring diagram

  1. Power supply (Line)
  2. Power supply (Neutral)
  3. Heating cable wire 1*
  4. Heating cable wire 2*
  5. N/A
  6. 6-7 Floor sensor connection

* Order Heating wire 1 and 2 does not apply. EARTH: Connect the earth of the heating cable and the earth of the power supply outside the thermostat.

Diagram showing connections labeled L, N, L1, N1, and 1-7, with NTC indicated.

3. Display icon explanation

Both Auto and Manual indicators on: Temporary temp. is manually set in Auto Mode. Returns to auto program schedule at next setpoint.

Icons displayed: Auto mode (point 5), Manual mode (point 6), Holiday mode (point 6), Heating active, Day indicator (point 4), Time (point 4), Frost protection active, Open window active, Key lock active, Current period indicator.

Display shows: Set, time 15:08, temperature 23.5°C, Weekly, Temp. reading.

Controls: On/Off, Mode (□), - key, + key.

Instruction: Long press to lock or unlock.

4. Time setting

5. Choose mode

Press ?️ to switch between Auto Mode or Manual mode.

6. Programming (Auto Mode)

(Thermostat on) Long press ?️ to enter options

Press ◀️ choose 02 and then ?️ to enter programming

Press ◀️ to choose hours, min. and temp. (with ◀️ or ▶️ and ?️)

There are 3 periods (6 setpoints) per day. See standard schedule for reference:

Wake up (On) Away (Off) Home (On) Away (Off) Home (On) Sleep (Off)
Setpoint Setpoint 1 Setpoint 2 Setpoint 3 Setpoint 4 Setpoint 5 Setpoint 6
Time/Temp 06:00 20°C 08:00 15°C 11:30 20°C 13:30 15°C 17:00 20°C 22:00 15°C

7. Holiday Mode

8. Sensor error

When an "E1" or "E2" code is shown the sensor is wrongly connected or broken. The thermostat will stop heating until the sensor is connected correctly or replaced.

9. Advanced settings

WARNING: Changing advanced settings may cause undesired results. Please consult your installer before entering this menu!

Press the on/off button once, long press ?️ to enter Advanced menu A. Press ◀️ to choose between A1 to AE. Press ◀️ or ▶️ to adjust.

No. Item Parameters Default
A1 Measured temp. calibration -9°C to +9°C 0.5°C
A2 Differential 0.5°C to 2.5°C 1°C
A3 Key lock 0: Half lock
1: Full lock
0
A4 Power with memory function 0: Power with memory function
1: Shutdown power after power off
2: Shutdown power after power on
0
A5 Backlight time 5 to 30 seconds 10 sec
A6 Programmable 0: 5+2 (Week 1-5 and weekend 6-7)
1: 6+1 (Week 1-6 and sunday 7)
2: 7 (Week 1-7)
0
A7 Lowest temp. setting 1-10°C 5°C
A8 Highest temp.setting 20-70°C 35°C
A9 Low temp.protection 1: 1°C -10°C
Function off: > 10°C Display (-----)
5°C
AA High temp.protection 1: 35°C-70°C
2: Function off: < 35°C Display (-----)
45°C
AB High temp. protection differential 1-9 2
AC Running temp. of open window function 1: 10-20°C,
2: Function off: < 10°C Display (-----)
15°C
AD Running time of open window function 10-20 min 10
AE Reset to factory settings Long press until display goes blank
Models: SF300 Digital Thermostat, SF300, Digital Thermostat, Thermostat, SF300 Digital Thermostat

File Info : application/pdf, 1 Pages, 309.71KB

PDF preview unavailable. Download the PDF instead.

SF300 Operating-Manual

References

Adobe PDF Library 16.0.5 Adobe InDesign 17.1 (Macintosh)

Related Documents

Preview Klima SF300 Digital Thermostat Operating Instructions
Comprehensive operating instructions for the Klima SF300 Digital Thermostat, covering technical details, wiring, display icons, programming, advanced settings, and troubleshooting for underfloor heating systems.
Preview Klima MIC2 Thermostat User Manual: Installation, Features, and Settings
Comprehensive user manual for the Klima MIC2 electric underfloor heating thermostat, covering installation, setup, modes, programming, technical specifications, and advanced functions.
Preview C16 Controller Programming Guide
A comprehensive guide to programming the C16 controller, detailing how to set heating schedules for different times of the day and days of the week.
Preview KLIMA Electric Underfloor Heating Mat Installation Guide
Detailed installation instructions for KLIMA Electric Underfloor Heating Mats (FHM_TWIN_ALU_150), covering technical specifications, preparation, installation methods, and important safety guidelines for optimal performance.
Preview Kuidas kasutada mobiilset kliimaseadet GPC09AM
See kasutusjuhend annab üksikasjalikud juhised mobiilse kliimaseadme GPC09AM kasutamiseks, sealhulgas paigaldamine, kasutamine, hooldus ja tõrkeotsing. Õppige, kuidas oma kliimaseadet tõhusalt kasutada.