User Manual for SKYDANCE models including: E1-L Plus ER, E1-L Plus EC, E1-L Plus ED, E1-L Plus EDC, E1-L Plus EB, E1-L Plus EBC, E1-L Plus EM1, E1-L Plus EM2, E1-L Plus EM3, E1-L Sensor LED Dimmer, E1-L, Sensor LED Dimmer, LED Dimmer, Dimmer
File Info : application/pdf, 2 Pages, 660.17KB
DocumentDocumentSensor LED Dimmer Model No.: E1-L + ER, E1-L + EC, E1-L + ED, E1-L + ED(C), E1-L + EB, E1-L + EB(C), E1-L + EM1, E1-L + EM2, E1-L + EM3 9 sensor detector/1 ChannelConstantVoltage/8A output RED Features Input connect with 9 kinds of sensor detector optional, output connected directly to the low voltage LED strip. Max 8A output current, max output power 384W@48V. PIR motion sensor: when people or objects enter the sensitive eld, the light turn on; when these exit the sensitive eld, the light turn off after 30 seconds. Touch sensor: short touch to turn on or turn off light; long touch to dimming up or down. Door sensor: when the door open, or no obstacle ahead, the light turn on gradually; when the door close, or obstacle ahead, the light turn off gradually. Hand sweep sensor: when hand sweep, the light turn on gradually; when hand sweep again, the light turn off gradually. 3 kinds of microwave motion detector: turn on the light upon detection of motion, and turn off after a pre-selected hold time when there is no movement, without dimming, with dimming and two-step dimming function respectively. All microwave motion detector, built-in daylight sensor, detection area, time delay and daylight threshold can be set via knob potentiometer for each specific application. Technical Parameters Input and Output Input voltage Input current Output voltage Output current Output power Output type 12-48VDC 8.1A 12-48VDC 8A 96W/192W/288W/384W (12V/24V/36V/48V) Constant voltage Warranty and Protection Warranty 5 years Safety and EMC EMC standard (EMC) Safety standard(LVD) Certification ETSI EN 301 489-1 V2.2.3 ETSI EN 301 489-17 V3.2.4 EN 62368-1:2020+A11:2020 CE,EMC,LVD Environment Operation temperature Case temperature (Max.) IP rating Ta: -30 OC ~ +55 OC T c: +85OC IP20 Mechanical Structures and Installations OUTPUT Sensor input SENSOR INPUT + S E1-L Installation rack INPUT 12-48VDC User Manual Ver 1.0.0 LED output LED output + Power input + Power input - Installation rack 33mm E1-L 97mm 18mm Wiring Diagram ER (PIR Motion Sensor) or othersensor OUTPUT E1-L Sensor LED Dimmer SENSOR INPUT + Uin=12-48VDC S Iin=8.1A Uout=12-48VDC Iout=8A Pout=96-384W Temp Range: -30~+55 INPUT 12-48VDC AC100-240V Power Supply 12-48VDC Constant Voltage ER: PIR Motion Sensor Wire length:1meter 33.5 mm 19.0 mm When people enter the sensitive field, the light turn on. When people exit the sensitive field, the light turn off after 30 seconds. EC: Touch Sensor Wire length:1meter Short touch the LED, turn on or turn off light. Long touch the LED, dimming up or down. ED / ED(C): Door Sensor 16.0 mm 33.5 mm 19.0 mm 14.0 mm Single color LED strip + Sensor data Sensitive eld Sensitivity angle 3m 120 Sensor data Dimming range PWM Frequency 0 -100% 128Hz Wire length:1meter ED ED(C) Wire length:1meter When the door open, or no obstacle ahead, the light turn on gradually. When the door close, or obstacle ahead, the light turn off gradually. EB /EB(C): Hand Sweep Sensor Wire length:1meter EB EB(C) Wire length:1meter When hand sweep, the light turn on gradually. When hand sweep again, the light turn off gradually. 33.5 mm 19.0 mm 12.5 mm 32.30 mm 31.50 mm 33.5 mm 19.0 mm 12.5 mm 32.30 mm 31.50 mm Sensor data Detective distance Detective angle 10cm 15-30 13.00 mm Sensor data Detective distance Detective angle 8cm 15-30 13.00 mm EM1: Microwave Sensor Switch E1-L Sensor LED Dimmer 42.5 mm 67.0 mm 73.5 mm EM1 Microwave SensorSwitch 10.525GHz Sensor Output + S Light Sensing 1meter 22.0 mm Sensor data HF system Power consumption Detection zone Detection sensitivity Hold time Daylight threshold Mounting height Motion detection Detection angle 10.525GHz < 0.5W(Standby) , <1W(Operation) Max.(DxH) 20 x 15m 10%/25%/50%/75%/100% 10s/30s/90s/3min/10min/20min/30min 10lux/30lux/50lux/100lux/150lux/200lux/Disable 15m Max. 0.5-3m/s 150°(wall installation), 360°(ceilling installation) This sensor is a motion switch without dimming function, which turn on the light upon detection of motion, and turn off after a pre-selected hold time when there is no movement. 1. With sufficient ambient light, the sensor does not turn on the light. 2. With insufficient ambient light, the sensor turn on the light when motion is detected. 3. After hold time, the light turns off if no motion detected. Sensor setting: By selecting the combination on knob potentiometer, sensor data can be precisely set for each specific application. 50% Detection area: Detection area can be reduced by rotate knob to fit precisely each application. SENS 25% 75% 100% 10% 30 10 TIME 100 50 LUX off 150 200 Hold time: Refers to the time period remains light on state after no motion detected. Daylight sensor: The sensor can be set to only allow the lamp to illuminate when below a defined ambient brightness threshold. Whensettooff(Disable)mode,thedaylight sensor will switch on the lamp when motion is detected regardless of ambient light level. 50lux: twilight operation. 30 lux: evening operation. 10 lux: darkness operation. Note that daylight sensor is active only when lamp totally switches off, and the ambient lux level refers to internal light reaching the sensor. Setting on this demonstration: Detection area: 50% Hold time: 90S Daylight sensor: 50lux Page 1 EM2: Microwave Sensor Dimmer 42.5 mm 67.0 mm 73.5 mm EM2 Microwave SensorDimmer 10.525GHz Sensor Output + S Light Sensing 1meter 22.0 mm Sensor data HF system Power consumption Detection zone Detection sensitivity Hold time Daylight sensor Mounting height Motion detection Detection angle 10.525GHz < 0.5W(Standby) , <1W(Operation) Max.(DxH) 20 x 15m 10%/25%/50%/75%/100% 10s/30s/90s/3min/10min/20min/30min 50lux/100lux/150lux/200lux/250lux/300lux/400lux 15m Max. 0.5-3m/s 150°(wall installation), 360°(ceilling installation) This sensor is a motion switch with dimming function, which turn on the light and dim up to expected brightness level upon detection of motion, and turn off after a pre-selected hold time when there is no movement. 1. The sensor turn on the light and dim up to expected brightness level when motion is detected. 2. After hold time, the light turn off if no motion detected. Sensor setting: By selecting the combination on knob potentiometer, sensor data can be precisely set for each specific application. 25% 50% SENS 75% 100% Detection area: Detection area can be reduced by rotate knob to fit precisely each application. 10% Hold time: Refers to the time period remains light on state after no motion detected. TIME Daylight sensor: The sensor can be set to allow the lamp to illuminate to expected brightness level. If the detected brightness is less than the expected brightness, the output will dim up to full brightness(100%). If the detected brightness is larger than the expected brightness, the output will dim down to min brightness(1%). LUX Note that daylight sensor is active only when lamp switches on, and the ambient lux level refers to internal light reaching the sensor. Setting on this demonstration: Detection area: 50% Hold time: 90S Daylight sensor: 150lux User Manual Ver 1.0.0 EM3: Microwave Sensor Switch (2-step dimming) 42.5 mm 67.0 mm 73.5 mm EM3 Microwave SensorSwitch 2-step dimming 10.525GHz Sensor Output + S Light Sensing 1meter 22.0 mm Sensor data HF system Power consumption Detection zone Detection sensitivity Hold time Stand-by time Daylight sensor Mounting height Motion detection Detection angle 10.525GHz < 0.5W(Standby) , <1W(Operation) Max.(DxH) 20 x 15m 10%/25%/50%/75%/100% 10s/30s/90s/3min/10min/20min/30min 10s/30s/90s/3min/10min/20min/30min 10lux/30lux/50lux/100lux/150lux/200lux/Disable 15m Max. 0.5-3m/s 150°(wall installation), 360°(ceilling installation) This sensor is a motion switch with two-step dimming function, which turn on the light upon detection of motion, after a pre-selected hold time, dim to 20% brightness, and turn off after a pre-selected stand-by time when there is no movement. 1. With sufficient ambient light, the sensor does not turn on the ight. 2. With insufficient ambient light, the sensor turn on the light and dim to 100% brightness when motion is detected. 3. After elapse of hold time, the sensor dim to 20% brightness if no new motion detected. 4. After elapse of stand-by time, the sensor turns off the light if no motion detected. Sensor setting: By selecting the combination on knob potentiometer, sensor data can be precisely set for each specific application. 25% 10% 50% SENS TIME 100 50 LUX off 150 200 75% 100% Detection area: Detection area can be reduced by rotate knob to fit precisely each application. Hold time: Refers to the time period remains light on and 100% brightness state after no motion is detected. Stand-by time: Refers to the time period remains light on and dim to 20% brightness state after elapse of hold time if no new motion is detected. Thestand-bytimeissameasthe hold time. Daylight sensor: The sensor can be set to only allow the lamp to illuminate when below a defined ambient brightness threshold. Whensettooff(Disable)mode,thedaylight sensor will switch on the lamp when motion is detected regardless of ambient light level. 50lux: twilight operation. 30 lux: evening operation. 10 lux: darkness operation. Note that daylight sensor is active only when lamp totally switches off, and the ambient lux level refers to internal light reaching the sensor. Setting on this demonstration: Detection area: 50% Hold time & Stand-by time: 90S Daylight sensor: 50lux 30 10 Microwave Sensor Detection Pattern E1-L Sensor LED Dimmer 10% 25% 50% 75% 100% 2 5 8 12 15 10 8 6 4 2 10% 2 25% 4 50% 75% 100% 6 8 10 Wall mounting pattern(Unit:m) Suggested installation height: 1-1.8m Ceilling mounting pattern(Unit:m) Suggested installation height: 2.5-15m Microwave Sensor User recommended settings Scenarios Settings Passage, staircase Balcony, corridor Cloakroom, storeroom Garage Kitchen Dinning room Toilet Meeting room Indoor public access Underground public access Detection distance 4-6m 4-6m 2-3m 2-3m 3-4m 3-4m 2-3m 2-3m 4-6m 4-6m Hold time 10s 10s 90s 90s 90s 3min 3min 10min 10min 10min Daylight sensor Twilight(50lux) / Darkness(10lux) Twilight(50lux) / Darkness(10lux) Evening(30lux) Evening(30lux) Evening(30lux) Evening(30lux) / Twilight(50lux) Daytime(>50lux) / Evening(30lux) Evening(30lux) Daytime(>50lux) Daytime(>50lux) Microwave Application Notice 1. The sensor is designed for indoor use only. The raining or wind blowing may trigger the microwave sensor even if without human motion when outdoor use. 2. The sensor should be installed by a professional electrician. please turn off the power before installing, wiring and changing setting of the knob. 3. The distance between any two sensors should be at least 3m to avoid interference each other. 4. When the microwave sensor is installed in a metal lighting fixture or space with large reflector, for example a warehouse with metal roof, the microwave signal will be reflected and cause the lights permanent illuminated even if without motion signal. Please reduce the detection area to solve the problems. 5. Make sure the sensor not close to or be blocked by high density materials, such as metal, glass, concrete walls etc. The materials will reduce or block microwave signal and cause false trigger. 6. The sensor which installed in the plastic and glass lampshade will reduce th sensitivity. For every 3mm increase in thickness, the sensitivity will reduced by 20%. 7. The light sensitivity threshold is in a sunny environment, no shadow and ambient light diffuse reflection. Ambient lux level could be different in different environment, weather, climate, time-of-delay and season. 8. Make sure there are no fans, DC motor, or other vibrating objects in installation area. The movement will trigger sensor as well. Page 2Corel PDF Engine Version 16.1.0.843 CorelDRAW X6