Instruction Manual for KEN-A-VISION models including: T-26001 Vision Scope 2 Stereo Microscope, T-26001, Vision Scope 2 Stereo Microscope, Stereo Microscope, Microscope
KEN-A-VISION T-26001 (01) PDF MANUAL - Manual-Hub.com
File Info : application/pdf, 12 Pages, 1.01MB
DocumentDocumentVision Scope 2 Stereo Microscope Instruction Manual T-22XXX Series T-26001 www.ken-a-vision.com https://manual-hub.com/ !" # ! " $ https://manual-hub.com/ 1) Microscope should be stored in a dry and clean environment. Do not expose the microscope to the direct sunlight. Avoid high temperatures and violent vibration. 2) This microscope is a precision instrument. Handle with care. Avoid impact and abrupt movement during transportation. 3) To keep the image clear, clean any fingerprints or stains on the surfaces of the lens. 4) Never turn the left and right focusing knob in the opposite direction at the same time. Microscope damage will occur. % 1) All lenses must be kept clean. Fine dust on the surface of the lens should be blown off with hand blower or wiped off gently with a soft lens tissue. Fingerprints and oil marks should be cleaned with a tissue moistened with a small amount of a 3:7 mixture of alcohol and ether. 2) Never use organic solution to clean the other surfaces (especially the plastic surfaces). If necessary, please use a neutral detergent. 3) Once assembled, do not take the microscope apart as this may cause damage to the microscope. 4) After use, cover the microscope with the provided dust-cover and store in a dry, clean environment to prevent rust. 5) To ensure proper performance, please check and clean the microscope periodically. https://manual-hub.com/ Eyepiece shield Eyepiece Lock screw Head Illumination device Glass stage Clip Base Diopter adjustment ring Handle Focusing knob Power Dimmer knob https://manual-hub.com/ Eyepiece Eyepiece shield Head Lock screw Illumination device Glass stage Clip Base https://manual-hub.com/ Figure 1 Figure 2 1) Place the microscope base on a flat, firm surface and position the frosted stage plate on the base. (Figure 1) 1) Check the coarse focus knob on either side of the main support. The coarse focus knob should turn easily. 2) If you want to adjust the degree of tightness of the focusing arm, you can hold one of the focusing knobs and turn another one to attain a suitable position. The degree of tightness relies on the direction to be turned. The clockwise direction is tight; counterclockwise is loose. (Figure 2) 1) Set the specimen in the center of the stage plate. If necessary, clamp the slide with the clips. 2) To operate, plug the small round plug into the back of the base of the microscope and then plug the opposite end into the power outlet. Figure 3 1) Turn the focusing knob and observe the specimen through the right eyepiece until the image of the specimen is clear. 2) Observe the specimen through the left eyepiece and adjust the diopter ring until the image is clear. (Figure 3) https://manual-hub.com/ Figure 4 1) Adjust the two eyepieces along the direction of the arrow shown in Figure 4 until eyepiece feels comfortable and a single image is seen. 2) Use the left rheostat (dimmer knob) to adjust light intensity of the bottom (transmitted) light. 3) Use the right rheostat (dimmer knob) to adjust light intensity of upper (incidental) light. https://manual-hub.com/ " !!! " Product Number T-22001 T-22011 T-22021 T-22041 T-22051 T-22061 Magnifications Eyepieces Heads / Objectives 2 10x 2 15x 2 20x 1x & 3x 2x & 4x 10x & 30x 15x & 45x 20x & 60x 20x & 40x 30x & 60x 40x & 80x Note: The items marked are included; others are optional. #$$ " Zoom Magnifications Eyepieces Objective Zoom Range 2 10x 2 15x 2 20x 0.7x 4.5x 7x - 45x 10.5x 67.5x 14x 90x Note: The items marked are included; others are optional. https://manual-hub.com/ !" # !!! Objective Mag. 1X 2X 3X 4X Working Distance (mm) 100 Eyepiece SC6EP10 Objective Mag. field 10X 20 20X 10 30X 6.7 40X 5 Eyepieces (optional) SC6EP15 SC6EP20 Objective Mag. Mag. field Objective field 15X 15 20X 11 30X 7.5 40X 5 T-22XXX 45X 5 3.3 SERIESX T-22XXX 3.75 80X 2.5 SERIESX 6-2 Auxiliary objectives for T-22XXX Series Auxiliary objectives SC6OB5 SC6OB15 SC6OB20 Magnification 0.5X 1.5X 2X Working distancemm 165 45 30 Working distance is fixed regardless of the magnification factor. Total magnification = Objective mag. X Auxiliary mag. X Auxiliary mag. Diameter of field of view (mm) = Eyepiece field Objective magnification X Auxiliary objective magnification Photo adaptor mag. = Objective mag. X Auxiliary objective mag. X Photo eyepiece mag. https://manual-hub.com/ # " !!! Head Model T-22001 T-22041 Objective magnification Working distance Observation angle Interpupillary distance adjustment 1X3X 2X4X 100mm 45° Linkage between left and right eyepiece tube range of single adjustment: 54-75mm Diopter adjustment Range of single adjustment ±5D Objective Main body Mount with auxiliary objectives Field of view Mount the head Focusing device Glass stage Screw holeM48*0.75 20mm Mount the head in the bracket hole (diameter: 76mm) Focus adjustment by turning the focusing knobs. Range of single adjustment: 10 mm Diameter 60mm Clips Put it on the base from top https://manual-hub.com/ ! " . Trouble 1.Double images 2.Dirt appears in the field of view Cause Interpupillary distance is not correct Diopter adjustment is not correct Left and right eyepieces are different magnifications. Dirt on the specimen Dirt on the surface of eyepiece Remedy Adjust the interpupillary distance Adjust the diopter Mount eyepieces of the same magnification Clean the specimen Clean the surface 3.Image is not clear 4.Image is not clear while adjusting the focus Dirt on the surface of the objective Diopter adjustment is not correct Focus is not correct Clean the objective Adjust the diopter Adjust the focus 5.The focusing knob does not The focusing knob is too tight turn smoothly Loosen it to a suitable position 6.The image is obscure because of the head is slipping down by during observation The focusing knob is too loose Tighten it to a suitable position 8.Eyes feel tired easily Diopter adjustment is not Adjust the diopter correct Brightness of light is not correct Adjust the brightness The bulb was not inserted Insert it correctly correctly https://manual-hub.com/ Ken-A-Vision Mfg. Co., Inc. 5615 Raytown Road, Kansas City, MO 64133 USA Phone : (816) 353-4787 Fax: (816) 358-5072 www.ken-a-vision.com https://manual-hub.com/ %& "#'