Instruction Manual for randell models including: 8000-290, 9000W-290, 9000W-290 Series Solid Hinged Door Prep Table, Solid Hinged Door Prep Table, Hinged Door Prep Table, Door Prep Table
Unified Brands » Raised Rail "Pizza" Prep Tables - Unified Brands
Unified Brands » Literature Links Results - Unified Brands
Randell 8260N-290 Refrigerated Raised Rail Prep Table Two-section 60" W
File Info : application/pdf, 28 Pages, 5.15MB
DocumentDocumentPART NUMBER PP MNL1803, REV. H (05/22) This manual provides information for: OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR 8000-290 & 9000W-290 SERIES PREP TABLES 888-994-7636, fax 888-864-7636 unifiedbrands.net THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WARNING R290 flammable refrigerant in use. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once. Manufacture Service/Questions 888-994-7636. RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE: Due to a continuous program of product improvement, Unified Brands reserves the right to make changes in design and specifications without prior notice. NOTICE: Please read the entire manual carefully before installation. If certain recommended procedures are not followed, warranty claims will be denied. MODEL NUMBER _________________________ SERIAL NUMBER _________________________ INSTALLATION DATE ______________________ The serial number is located behind the hinged vented door of the compressor machine compartment. An example is shown here. EQUIPMENT DESCRIPTION MODEL PAN L CAPACITY 1/3 SIZE D H WORK REAR OF UNIT SURFACE (CLOSED COVER) OVERALL (COVER OPEN) DOORS STORAGE HP CU. FT. VOLT AMPS NEMA SHIP WT. 8148N-290 6 48" 33" 35" 44" 52.5" (1)27" 9.0 1/3 115/60/1 6 5-15P 405 8260N-290 8 60" 33" 35" 44" 52.5" (2)24" 14.67 1/3 115/60/1 6 5-15P 459 8268N-290 9 68" 33" 35" 44" 52.5" (2)27" 17.76 1/3 115/60/1 6 5-15P 484 8383N-290 11 83" 33" 35" 44" 52.5" (2)24",(1)21" 23.55 (2) 1/4 115/60/1 5.8 5-15P 585 8395N-290 13 95" 33" 35" 44" 52.5" (3)27" 28.18 (2) 1/4 115/60/1 5.8 5-15P 630 84111N-290 15 111" 33" 35" 44" 52.5" (3)24",(1)21" 32.81 (2) 1/4 115/60/1 5.8 5-15P 675 MODEL 8148W-290 8268W-290 8395W-290 PAN L CAPACITY 1/6 SIZE 21 48" 30 68" 42 95" D H WORK SURFACE (NO CUTTING BOARD) REAR OF UNIT (NO COVER) 33" 35" 46.5" 33" 35" 46.5" 33" 35" 46.5" OVERALL 53.5" 53.5" 53.5" DOORS STORAGE HP CU. FT. VOLT AMPS NEMA SHIP WT. (1)27" (2)27" (3)27" 9.0 17.76 28.18 1/3 115/60/1 6 1/3 115/60/1 6 (2) 1/4 115/60/1 5.8 5-15P 530 5-15P 595 5-15P 785 MODEL PAN L CAPACITY 1/6 SIZE 9148W-290 18 48" 9260W-290 24 60" 9272W-290 30 72" D H DOORS STORAGE HP VOLT AMPS NEMA SHIP WT. CU. FT. (BASE & RAIL) 33" 46.5" (1) 27" 5.5 1/3 115/60/1 6 5-15P 405 33" 46.5" (2) 24" 9.8 1/3 115/60/1 6 5-15P 465 33" 46.5" (2) 27" 11.2 1/3 115/60/1 6 5-15P 510 Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications. © 2022 Unified Brands. All Rights Reserved. IMPORTANT - READ FIRST - IMPORTANT INTERIOR EVAPORATOR COVER DANGER WARNING RISQUE D'INCENDIE OU D'EXPLOSION. INFLAMMABLE ALERTE RÉFRIGÉRANT UTILISÉ. DO NOT REMOVE PANEL - HIGH VOLTAGE - RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. NE PAS UTILISER DE DISPOSITIFS MÉCANIQUES POUR DO NOT USE MECHANICAL DEVICES TO DEFROST REFRIGERATOR. DO NOT DÉGIVRER LE RÉFRIGÉRATEUR. NE FAIRE AUCUN TUBE QUALIFIED PERSONNEL ONLY NE PAS RETIRE LE PANNEAU - HAUTE TENSION - PERSONNEL QUALIFIÉ SEULEMENT NO RETIRE EL PANEL - ALTA TENSIÓN - CALIFICADO PERSONAL CAUTION ATTENTIÓN PUNCTURE REFRIGERANT TUBING. RÉFRIGÉRANT DE PONCTION. SB6.1.2 MOVING PARTS, DO NOT OPERATE WITH COVER REMOVED RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. NO UTILICE DISPOSITIVOS MECÁNICOS PARA DESCONGELAR EL REFRIGERADOR. NO PERFORE LA TUBERÍA DEL REFRIGERANTE. PP LBL1701 REV B PIÉCES MOBILES NE PAS FAIRE FONCTIONNER SANS COUVERCLE LAS PIEZAS DE MOVIMIENTO NO FUNCIONAN CON LA CUBIERTA RETIRADA EXTERIOR OF UNIT CAUTION MISE EN GARDE RISQUE D'INCENDIE OU D'EXPLOSION. ÉLIMINER RISK OF FIRE OR EXPLOSION. DISPOSE OF PROPERLY IN ACCORDANCE WITH FEDERAL OR LOCAL REGULATIONS. FLAMMABLE REFRIGERANT USED. (or DISPOSER) CORRECTEMENT CONFORMÉMENT AUX RÉGLEMENTATIONS FÉDÉRALES OU LOCALES. RÉFRIGÉRANT INFLAMMABLE UTILISÉ. PP LBL1704 REV B PRECAUCIÓN RIESGO DE INCENDIO O EXPLOSIÓN. DESÉCHELO ADECUADAMENTE CONFORME A REGLAMENTOS FEDERALES O LOCALES. REFRIGERANTE INFLAMABLE UTILIZADO. SB6.1.4 NEAR EXPOSED REFRIGERANT TUBING CAUTION MISE EN GARDE RISQUE D'INCENDIE OU D'EXPLOSION EN RAISON RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW DE LA PERFORATION DU TUBE RÉFRIGÉRANT; SUIVEZ ATTENTIVEMENT LES INSTRUCTIONS DE HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED. MANIPULATION. RÉFRIGÉRANT INFLAMMABLE UTILISÉ. PRECAUCIÓN RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACIÓN DE LA TUBERÍA DE REFRIGERANTE; SIGA CUIDADOSAMENTE INFLAMABLE UTILIZADO. LAS INSTRUCCIONES DE MANEJO. REFRIGERANTE SB6.1.5 PP LBL1705 REV B NEAR MACHINE COMPARTMENT AND NAMEPLATE DANGER RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING. DANGER RISQUE D'INCENDIE OU D'EXPLOSION. RÉFRIGÉRANT INFLAMMABLE UTILISÉ. POUR ÊTRE RÉPARÉ QUE PAR UN TECHNICIEN QUALIFIÉ. NE PAS PERFORER LE TUBE RÉFRIGÉRANT. PELIGRO RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. DEBE SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CAPACITADO. NO PERFORE LA TUBERÍA DEL REFRIGERANTE. SB6.1.3.a CAUTION MISE EN GARDE RISQUE D'INCENDIE OU D'EXPLOSION. RÉFRIGÉRANT RISK OF FIRE OR EXPLOSION. FLAMMABLE INFLAMMABLE UTILISÉ. CONSULTER LE MANUEL DE REFRIGERANT USED. CONSULT REPAIR MANUAL / OWNER'S GUIDE BEFORE ATTEMPTING TO INSTALL OR SERVICE THIS PRODUCT. ALL SAFETY PRECAUTIONS MUST BE FOLLOWED. RÉPARATION / GUIDE DE L'UTILISATEUR AVANT D'ESSAYER D'INSTALLER OU DE RÉPARER CE PRODUIT. TOUTES LES PRÉCAUTIONS DOIVENT ÊTRE RESPECTÉES. PP LBL1703 REVB PRECAUCIÓN RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO. CONSULTE EL MANUAL DE REPARACIÓN / MANUAL DEL USUARIO ANTES DE INSTALAR O REPARAR ESTE PRODUCTO. DEBEN SEGUIRSE LAS PRECAUCIONES DE SEGURIDAD.SB6.1.3.b INSTALLATION CAUTION: THIS UNIT CONTAINS R290 FLAMMABLE REFRIGERANT. USE CAUTION WHEN HANDLING MOVING AND USE OF THE REFRIGERATOR OR FREEZER. AVOID DAMAGING THE REFRIGERANT TUBING OR INCREASE THE RISK OF A LEAK. WARNING: FAILURE TO FOLLOW INSTALLATION GUIDELINES AND RECOMMENDATIONS MAY VOID THE WARRANTY ON YOUR UNIT. WARNING: IT IS IMPORTANT THAT YOUR UNIT HAS ITS OWN DEDICATED LINE. CONDENSING UNITS ARE DESIGNED TO OPERATE WITH A VOLTAGE FLUCTUATION OF PLUS OR MINUS 10% OF THE VOLTAGE INDICATED ON THE UNIT DATA TAG. BURN OUT OF A CONDENSING UNIT DUE TO EXCEEDING VOLTAGE LIMITS WILL VOID THE WARRANTY. THE DANFOSS CONTROLLER HAS LOW VOLTAGE PROTECTION AND WILL NOT OUTPUT VOLTAGE TO THE COMPRESSOR IF VOLTAGE IS LESS THAN 104V. WARNING: IT IS IMPORTANT THAT A VOLTAGE READING BE MADE AT THE COMPRESSOR MOTOR ELECTRICAL CONNECTIONS, WHILE THE UNIT IS IN OPERATION TO VERIFY THE CORRECT VOLTAGE REQUIRED BY THE COMPRESSOR IS BEING SUPPLIED. LOW OR HIGH VOLTAGE CAN DETRIMENTALLY AFFECT OPERATION AND THEREBY VOID ITS WARRANTY. WARNING: EVAPORATOR FANS RUN CONTINUOUSLY WHILE THE BASE IS POWERED ON. WARNING: THIS UNIT IS INTENDED FOR USE IN LABORATORIES IN COMMERCIAL, INDUSTRIAL, OR INSTITUTIONAL OCCUPANCIES AS DEFINED IN THE SAFETY STANDARD FOR REFRIGERATION SYSTEMS, ASHRAE 15. SELECTING A LOCATION FOR YOUR NEW UNIT The following conditions should be considered when selecting a location for your unit: 1. Floor Load: The area on which the unit will rest must be level, free of vibration, and suitably strong enough to support the combined weights of the unit plus the maximum product load weight. All casters must be in contact with the floor to support the weight. Casters may require shims in order for the caster to be in contact with the floor. NOTE: If there is a question pertaining to weight load limits, consult the factory at 1-888-994-7636. 2. Clearances: Unit shall have a clearance of 0 inches at the top, 0 inches at the rear and 0 inches at each side. 3. Ventilation: The air cooled self contained unit requires a sufficient amount of cool clean air. Avoid surrounding your unit around other heat generating equipment and out of direct sunlight. Also, avoid locating in an unheated room or where the room temperature may drop below 70° F (21°C) or above 86°F (32°C). Do not place any object that can block the ventilation exhaust from the machine compartment register. INSTALLATION CHECKLIST After the final location has been determined, refer to the following checklist prior to start-up: 1. Check all exposed refrigeration lines to ensure that they are not kinked, dented, or rubbing together or rubbing against any steel. 2. Check all visible components for any potential damage. 3. Check that the condenser and evaporator fans rotate freely without striking any stationary members. 4. Unit must be property leveled; Check all legs or casters ensure they all are in contact with the floor while maintaining a level work surface. Adjusting bullet feet height or shimming casters may be necessary if the floor is not level. NOTE: Damage to equipment may result if not followed. Unified Brands is not responsible for damage to equipment if improperly installed. 5. Plug unit into power source. Unit will come on. If unit does not turn on, refer to controller operation section of this manual to manually turn on the unit. 6. Allow unit time to cool down to holding temperature. If temperature adjustments are required, the control is located on the front panel. Confirm that the units is holding the desired temperature. 7. If unit has drawers, check drawer to ensure the drawer slides freely and fully extents along with seating in the cabinet properly when closed. 8. Refer to the front of this manual for serial number location. Please record this information in your manual on page 1 now. It will be necessary when ordering replacement parts or requesting warranty service. 9. Allow your unit to operate for approximately 45 minutes before putting in food in the rail. Allow 2 hours for base of the unit to cool down to storage temperature, prior to loading product. NOTE: All motors are oiled and sealed. ELECTRICAL SUPPLY The wiring should be done by a qualified electrician in accordance with local electrical codes. A properly wired and grounded outlet will assure proper operation. Please consult the data tag attached to the compressor to ascertain the correct electrical requirements. Supply voltage and amperage requirements are located on the serial number tag located on the rear interior wall. 2 OM-8000 & 9000W SERIES PREP TABLES OPERATION AMBIENT CONDITIONS Unit is designed for normal operating temperatures between 70° F (21°C) - 86°F (32°C). Operating outside of those temperatures may cause premature product wear or failure. Unified Brands has attempted to preset the temperature control to ensure that your unit runs at an optimum temperature, but due to varying ambient conditions, including elevation, food type and your type of operation, you may need to alter this temperature using control adjustment until desired temperature is reached. CAREL CONTROLLER OPERATION LED FUNCTION Compressor energized Defrost in progress Evaporator fan energized MECHANICAL COMPARTMENT WARNING: BASE EVAPORATOR FANS ARE ALWAYS IN OPERATION WHEN THE UNIT IS ENERGIZED. DISCONNECT POWER TO THE UNIT PRIOR TO PERFORMING MAINTENANCE. An alarm is occurring 1. To power on the base, press and hold the base control power button until the LED display turns on. To power on the rail, press and hold the rail control power button until the LED display turns on. The power controls are located above the louver panel. 2. To power off the base press and hold the base control power button until the LED display turns off. To power off the rail press and hold the rail control power button until the LED display turns off. The power controls are located above the louver panel. 3. The drain valve for the upper rail is found behind the hinged vented door. The rail may be drained by placing a pan under the drain valve and opening the valve. (See Evening Shut Down of Prep Rail). MORNING STARTUP OF PREP RAIL 1. Unit cleaning may be performed at this time. 2. Turn on unit. See item 2 under the Mechanical Compartment section above for powering on the rail. 3. Allow a minimum 45 minutes for your unit to cool down before loading product. A uniform frost pattern will appear on side walls and bottom of prep rail area. 4. Load the product and proceed with food preparation. NOTE: Product entering unit must be at 35°F +/- 2°F. EVENING SHUT DOWN OF PREP RAIL 1. Remove product from unit at the end of the day's preparation. 2. Turn off unit. See item 3 under the Mechanical Compartment section above for powering on the rail. 3. Unit cleaning may be performed at this time if the frost has melted off the surface. 4. Once defrosted, the rail drain may be opened to remove any water that has resulted from the defrosting procedure. WARNING: IT IS RECOMMENDED TO ONLY MAKE CHANGES OF 2 DEGREE INCREMENTS AT A TIME. ALLOW FOR THE UNIT TO OPERATE 24 HOURS BETWEEN ADJUSTMENTS. IF THE 2 DEGREE ADJUSTMENT IS NOT ENOUGH ANOTHER ADJUSTMENT CAN BE MADE. IF THE SETTINGS NEED TO GO ABOVE OR BELOW THIS POINT THERE MAY BE OTHER CONTRIBUTING FACTORS AS TO THE CAUSE OF THE TEMPERATURE VARIANCES, PLEASE CONTACT THE FACTORY AT 1-800-621-8560. 3 OM-8000 & 9000W SERIES PREP TABLES POWER ON / OFF: Press and hold the Power Button seconds or until LED display turns On/Off. for more than 3 MANUAL DEFROST: Press and hold the Defrost Button seconds (melting snowflake will light). CHANGE SET POINT: To raise temperature for more than 3 1. Press and hold set button for 1 second to access set point. 2. When set point starts flashing, press up button to adjust set point. 3. Press set button for 3-seconds to save set point. CHANGE SET POINT: To lower temperature 1. Press and hold set button for 1 second to access set point. 2. When set point starts flashing, press down button 3. Press set button for 3-seconds to save set point. to adjust set point. DANFOSS CONTROLLER OPERATION LED FUNCTION Compressor energized & Evaporator fan de-energized Defrost in progress Fans delay after defrost completion ºC / ºF Evaporator fan energize An alarm is occurring Temperature unit MANUAL DEFROST DRAWER REMOVAL 1. Fully extend the drawer that is to be removed. 2. Remove product pans from drawer. 3. Lift up the drawer stop tabs on each side of drawer track. 4. Pull drawer out while lifting the tabs. POWER ON / OFF CHANGE SET POINT POWER ON / OFF: Press and hold the power button until LED display turns On / Off MANUAL DEFROST: Press and hold "Defrost" Button CHANGE SET POINT: To raise temperature 1. Press and hold " " to access set point. 2. When set point start flashing, Press " " to adjust set point. 3. After 30 seconds, the display automatically reverts to showing the current temperature. CHANGE SET POINT: To lower temperature 1. Press and hold "v" to access set point. 2. When set point start flashing, Press "v" to adjust set point. 3. After 30 seconds, the display automatically reverts to showing the current temperature. CHANGE FROM ºF /ºC : 1. Press the up/down buttons simultaneously for 5 seconds to access the menu. 2. Password is requested. Password is 000. 3. Press the bottom left button to OK the password. 4. Using the up/down buttons, navigate to the "diS" level. Press the bottom left button to OK the selection. 5. Using the up/down buttons, navigate to the "CFu" level. Press the bottom left button to OK the selection. a. "-F" designates Fahrenheit. b. "-C" designates Celsius. 6. Press the top left button repeatedly to return to exit and return to the home screen. DRAINING THE RAIL 1. Open hinged mechanical compartment door 2. Place container under drain valve 3. Open valve until all water has drained 4. Close valve 5. Discard water DRAWER INSTALLATION To remove and re-install individual drawers and drawer tracks, please refer to the figure above for proper installation instructions. MAINTENANCE WARNING: DO NOT USE SHARP UTENSILS AND/OR OBJECTS. WARNING: DO NOT USE STEEL PADS, WIRE BRUSHES, SCRAPERS, OR CHLORIDE CLEANERS TO CLEAN YOUR STAINLESS STEEL. CAUTION: DO NOT USE ABRASIVE CLEANING SOLVENTS, AND NEVER USE HYDROCHLORIC ACID (MURIATIC ACID) ON STAINLESS STEEL. WARNING: DO NOT PRESSURE WASH EQUIPMENT AS DAMAGE TO ELECTRICAL COMPONENTS MAY RESULT. Unified Brands strongly suggests a preventive maintenance program which would include the following monthly, weekly, and daily procedures: If a failure of the equipment is a direct result of any of the Preventative Maintenance guidelines being neglected, the repairs and parts replacements will not be covered under warranty. It is recommended that the customer contact the local Authorized Service Agent to provide a quote to perform periodic Preventative Maintenance. WEEKLY PM PROCEDURES 1. Clean all gaskets on a weekly if not daily basis with a solution of warm water and a mild detergent to extend gasket life. Do not use bleach for cleaning gaskets. Bleach will cause the gaskets to become brittle and not reach their normal life expectancy. 2. Clean and disinfect rail drains with a solution of warm water and mild detergent on a weekly basis. It is recommended to open and close the drain valve as the hot water is flowing through to clean any debris from the internal valve components. 4 OM-8000 & 9000W SERIES PREP TABLES MONTHLY PM PROCEDURES 1. Cleaning of all condenser coils on a monthly basis. Condenser coils are a critical component in the life of the compressor and must remain clean to assure proper air flow and heat transfer. Failure to maintain this heat transfer will affect unit performance and eventually destroy the compressor. Clean the condenser coils with coil cleaner and/or a vacuum, cleaner and brush. NOTE: Brush coil in direction of fins, normally vertically as to not damage or restrict air from passing through condenser. 2. Clean and disinfect drain lines and evaporator pan with a solution of warm water and mild detergent on a monthly basis. Remove clear plastic drain line from plastic tray of condensing unit and place pan under end of drain tube. Discard waste water from pan when cleaning is complete. Re-insert plastic drain tube into position on condensing unit. 3. Remove drawer tracks as per instructions on Drawer Installation guidelines. Once drawers are removed wipe away any debris buildup from the drawer tracks. The roller bearings come lubricated from the factory. Excessive oils and or water may remove the oils. It may be required to add lithium grease from time to time on bearings that appear dry. 4. Inspect all silicone seams at interior of the rail and refrigerated base cabinet on a monthly basis. Re-apply food grade silicone sealant as needed to any seams where silicone has peeled away or cracked. Apply silicone to a clean dry surface. Allow sufficient drying time to assure best adhesion of sealant. RECOMMENDED CLEANERS FOR YOUR STAINLESS STEEL INCLUDE THE FOLLOWING: JOB CLEANING AGENT COMMENTS Routine cleaning Soap, ammonia, detergent Medallion Apply with a sponge or cloth Fingerprints and smears Arcal 20, Lac-O-Nu, Ecoshine Provides a barrier film Stubborn stains and discoloration Cameo, Talc, Zud, First Impression Rub in the direction of the polish lines Greasy and fatty acids, blood, Easy-Off, Degrease It, burnt-on foods Oven Aid Excellent removal on all finishes Grease and Oil Any good commercial detergent Apply with a sponge or cloth Restoration/Preservation Benefit, Super Sheen Good idea monthly Reference: Nickel Development Institute, Diversey Lever, Savin, Ecolab, NAFEM Proper maintenance of equipment is the ultimate necessity in preventing costly repairs. By evaluating each unit on a regular schedule, you can often catch and repair minor problems before they completely disable the unit and become burdensome on your entire operation. For more information on preventive maintenance, consult your local service company or CFESA member. Most repair companies offer this service at very reasonable rates to allow you the time you need to run your business along with the peace of mind that all your equipment will last throughout its expected life. These services often offer guarantees as well as the flexibility in scheduling or maintenance for your convenience. For a complete listing of current Unified Brands ASA please visit www.unifiedbrands.net. Unified Brands believes strongly in the products it manufactures and backs those products with one of the best warranties in the industry. We believe with the proper maintenance and use, you will realize a profitable return on your investment and years of satisfied service. REPLACEMENT PARTS To order parts, contact your Authorized Service Agent. Supply the model designation, serial number, part description, part number, quantity, and when applicable, voltage and phase. CONTACT US If you have questions pertaining to the content in this manual, contact Unified Brands at 888-994-7636. TROUBLESHOOTING This unit is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are found at the end of this manual. When in doubt, turn unit off and contact service at 888-994-7636. SYMPTOM Unit does not run Unit too cold POSSIBLE CAUSE No power to unit Control in OFF position Faulty control Incorrect set point Door / drawer ajar Gasket torn or out of place Unit too warm Incorrect set point Warm product introduced to cabinet Ice on the coil Unit noisy Ice on the coil Unit does not defrost Excessive ice on the coil CAREL CONTROLLER CODES PROCEDURE Plug in unit Turn controller on Call for service at 888-9947636 Adjust control set point Ensure door / drawer is fully closed Inspect the gasket for wear and position Adjust control set point Pre-chill product 37ºF Initiate manual defrost Initiate manual defrost Initiate manual defrost DISPLAYED ALARM CODE E0 E1 dOr LO HI CHt Control probe Defrost probe Open door Low temperature High temperature Dirty condenser DANFOSS CONTROLLER CODES ALARM DISPLAYED ALARM CODE Hi Lo ALARM High Temperature Alarm Low Temperature Alarm CON Condenser Temperature High Limit uHi Line Voltage Too High uLi Line Voltage Too Low ACTION Inspect door/drawer sealing Contact service Contact service Clean condenser coil Inspect coil for any objects obstruction hindering airflow Contact service Verify voltage of power source, to be performed by qualified technician Contact service Verify voltage of power source, to be performed by qualified technician Contact service 5 OM-8000 & 9000W SERIES PREP TABLES Inspect door/drawer sealing LEA Continuous Compressor Runtime Inspect condenser coil, clean if necessary Contact service E01 S1 Sensor Failure Contact service E02 S2 Sensor Failure Contact service E03 S3 Sensor Failure Contact service E04 S4 Sensor Failure Contact service SERVICE CAUTION: COMPONENT PARTS SHALL BE REPLACED WITH FACTORY OEM PARTS. SERVICE WORK SHALL BE DONE BY FACTORY AUTHORIZED SERVICE PERSONNEL, SO AS TO MINIMIZE THE RISK OF POSSIBLE IGNITION DUE TO INCORRECT PARTS OR IMPROPER SERVICE. CAUTION: BEFORE MAKING ANY REPAIRS, ENSURE THE UNIT IS DISCONNECTED FROM ITS POWER SOURCE. This piece of equipment uses a R290 Refrigeration system. This equipment has been clearly marked on the serial tag the type of refrigerant that is being used. There is also a warning labels stating that the unit contains R290 refrigerant. R290 is safe to use as long as you follow these warning labels. No smoking or open flames when servicing this equipment. If needed, use a CO2 or powder type fire extinguisher. Replacement parts used on any R290 Refrigeration system cabinet must have specific UL certification for non-sparking components. Only authorized service technician, certified in R290 system should service this equipment. MANIFOLD SET A R134A manifold set can be used for servicing this equipment. REFRIGERANT RECOVERY Follow all national and local regulations for R-290 refrigerant recovery. LEAKING CHECKING AND REPAIR Leak check an R-290 system the same way you would an R-134a or R-404A system with the following exceptions. 1. Do not use a Halid leak detector on a R290 system. 2. Electronic leak detector must be designated specifically for combustible gas. Use of a bubble solution or an ultrasonic leak detector are acceptable. When repairing a leak, it is recommended using oxygen free dry nitrogen with a trace gas not exceeding 200PSI. When accessing an R290 system, piercing valves are not to remain on the equipment in a permanent manner. After charge is recovered, Schrader valves are to be installed on the process stubs. Proper charge is to be weighed into the system and the system is to be leak checked afterwards. The R290 equipment must have red process tubes and other devices through which the refrigerant is serviced, such as any service port. This color marking must remain on the equipment. If marking is removed, it must be replace and extend at least 2.5 centimeters (1") from the compressor. CHARGING Follow the charge amount specified on the data tag. It is recommended to use the shortest hoses possible to prevent undercharging. · Ensure the system is sealed and leak checked · Evacuate system to a minimum 500 micron · Weigh in correct charge · Leak check the system again · Bleed the refrigerant from the high side hose to the low side hose · Disconnect the hoses · Remove line taps WARRANTY Congratulations on the purchase of your new Unified Brands equipment. We hope you enjoy many years of reliable service in connection with the same. Please review all of the important safety and operational information contained in the Operator's Manual for this equipment before it is placed in service. If you have any questions related to equipment set up, operations, or service, please call 888-994-7636. In addition, please review the sales terms and conditions set forth below. *****IMPORTANT NOTICE***** WARRANTIES, LIMITATIONS ON WARRANTIES, AND LIMITATION OF REMEDIES The following Warranties, Limitation on Warranties, and Limitation of Remedies are included in the terms of sale for this product. Please read this entire warranty and all warranty modifications, disclaimers, and limitations of remedies set forth herein before accepting or using this equipment or product. Customer acknowledges and accepts the provisions of this notice by Customer's acceptance and use of the product. If these provisions are not acceptable and agreed to by Customer, then please return this product in its unused condition to Unified Brands or a Unified Brands authorized dealer. UNIFIED BRANDS warrants this product against defects in material and workmanship under normal use and services for which this product was designed. This warranty runs only to the original end user and is in lieu of any other liability for defects. THE WARRANTIES EXPRESSED IN THESE TERMS AND CONDITIONS ARE IN PLACE OF ANY AND ALL OTHER EXPRESS WARRANTIES (UNLESS SEPARATELY STATED IN PRINTED MATERIAL PREPARED BY US DESCRIBING OUR EQUIPMENT) AND EXCLUDE ALL IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE; NOR ARE THERE ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR OTHERWISE. In no event shall UNIFIED BRANDS be liable for damages or delay or for any consequential, special or contingent damages arising out of any breach of our warranty, whether or not we have knowledge of specific needs or our employees or agents have given any specific assurances. Anyone claiming that there has been a breach of warranty by UNIFIED BRANDS must give us written notice within THIRTY (30) days after discovery of the relevant defect or the right to assert such claim will have been waived conclusively and provided further that any such claim must also be asserted within the general warranty period for such equipment and/or parts. UNIFIED BRANDS will not be liable for any expense incurred without our prior written authorization for alterations made outside of our factory or for repairs which are not performed by UNIFIED BRANDS authorized service departments using UNIFIED BRANDS factory parts. Nor shall we be responsible for the performance of equipment as to which any repairs, revisions or alterations have been made by others. THE EXCLUSIVE REMEDY OF THE USER OR BUYER AND THE EXCLUSIVE LIABILITY OF UNIFIED BRANDS OR ANY SELLER OF UNIFIED BRANDS PRODUCTS, FOR ANY AND ALL CLAIMS, LOSSES, INJURIES, OR DAMAGES (INCLUDING CLAIMS BASED ON BREACH OF WARRANTY, CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY, OR OTHERWISE) RESULTING FROM OR ARISING OUT OF THE USE OF HANDLING OF THIS PRODUCT, SHALL BE THE RETURN OF THE PURCHASE PRICE OR AN AMOUNT NOT TO EXCEED THE ORIGINAL PURCHASE PRICE OF THE PRODUCT OR, AT THE ELECTION OF UNIFIED BRANDS OR THE SELLER, THE REPLACEMENT OF THE PRODUCT. https://unifiedbrands.net/ Randell-Warranty-Information 6 OM-8000 & 9000W SERIES PREP TABLES CONTROLS CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List SERVICE PART RP CNT1720BCAR RP CNT1720RCAR RP CNT1805BCAR RP CNT1805RCAR RF CNT2103 RF CNT2104 PP STK1802 CAREL CONTROLLER DESCRIPTION CONTROLLER, CAREL, PROGRAMMED - BASE - SGL COMPR SYSTEM CONTROLLER, CAREL, PROGRAMMED - RAIL - SGL COMPR SYSTEM CONTROLLER, CAREL, PROGRAMMED - BASE - DBL COMPR SYSTEM CONTROLLER, CAREL, PROGRAMMED - RAIL - DBL COMPR SYSTEM THERMISTOR, CAREL, QTI, AIR SENSOR, BARE LEADS, BLACK, 10' THERMISTOR, CAREL, QTI, COIL SENSOR, BARE LEADS, BLUE, 10' OVERLAY, CONTROL PANEL, 8000N COMMON XXX XX XXX XXX XX XXX XXX X XXX X XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 9148W-290 9260W-290 9272W-290 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 9148W-290 9260W-290 9272W-290 SERVICE PART RP CNT1720BC RP CNT1720RC RP CNT1805B RP CNT1805R RF CNT1602 RF CNT1603 PP STK1802 DANFOSS CONTROLLER DESCRIPTION CONTROLLER, DANFOSS, PROGRAMMED - BASE - SGL COMPR SYSTEM CONTROLLER, DANFOSS, PROGRAMMED - RAIL - SGL COMPR SYSTEM CONTROLLER, DANFOSS, PROGRAMMED - BASE - DBL COMPR SYSTEM CONTROLLER, DANFOSS, PROGRAMMED - RAIL - DBL COMPR SYSTEM THERMISTOR, DANFOSS, QTI, COIL SENSOR, MOLDED END, BLUE, 10' THERMISTOR, DANFOSS, QTI, AIR SENSOR, MODLED END, BLACK, 10' OVERLAY, CONTROL PANEL, 8000N COMMON 7 OM-8000 & 9000W SERIES PREP TABLES XXX---XX-XXX XXX---XX-XXX ---XXX--X-----XXX--X--- XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX BASE UNIT, 8000N-290 & 8000W-290 CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 ITEM SERVICE PART 1 HD CST060 1A HD CST061 1B HD CST040HD 1C HD CST041HD 2 RP LVR1803 2A RP LVR1804 2B RP LVR1805 3 HD CTH9901 4 HD BMP034 5 RP SHD1805 5A RP SHD1806 5B RP SHD1807 5C RP SHD1808 6 RP PNL1803 7 HD SHL180 7A HD SHL160 7B HD SHL9912 8 HD PIN0102 9 RP BRK0107 10 RP BRK0108 11 RP BRK1811 12* EL WIR1703 13* HD LEG9902 14* RP BCK0107 14A* RP BCK0108 14B* RP BCK0109 14C* RP BCK0110 14D* RP BCK0111 14E* RP BCK0112 15 RP END1901 * = NOT SHOWN 6" CASTERS W/ BRAKE 6" CASTERS W/O BRAKE 4" CASTERS W/ BRAKE 4" CASTERS W/O BRAKE LOUVER, HINGED LOUVER, HINGED LOUVER, HINGED LOUVER MAGNET BUMPER, RUBBER SHROUD, COND UNIT SHROUD, COND UNIT SHROUD, COND UNIT SHROUD, COND UNIT COVER, ACCCESS SIDE CMPR, L OR R SHELF 22" X 25" SHELF 19" X 25" SHELF 16.15" X 25" SHELF SUPPORT PIN SHELF SUPPORT - FRT & BACK SHELF SUPPORT BETWEEN DOORS LOUVER MOUNTING HINGE BRACKET POWER CORD 16/3 - 9' - 90 6" LEG W/ BULLET FOOT S/S BACK PANEL 48" S/S BACK PANEL 60" S/S BACK PANEL 68" S/S BACK PANEL 83" S/S BACK PANEL 95" S/S BACK PANEL 111" SIDE PANEL DESCRIPTION 8 OM-8000 & 9000W SERIES PREP TABLES XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX X-XXX XXX -X------- -----X--- XXXXXXXXX XXXXXXXXX X-X-X-XX- -X------- - - -XX- - -X -----X--- - - -XXX- -X X-X-X-X-X -X-X-X--- ---X-X--- XXXXXXXXX - - -XXX- -X XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX X-----X-- -X------- --X----X- ---X----- ----X---X -----X--- XXXXXXXXX BASE UNIT, 9000W-290 CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 9148W-290 9260W-290 9272W-290 ITEM SERVICE PART 1 HD CST060 1A HD CST061 1B HD CST040HD 1C HD CST041HD 2 RP LVR1807 2A RP LVR1808 2B RP LVR1809 3 HD CTH9901 4 HD BMP034 5 RP SHD1814 5A RP SHD1815 5B RP SHD1816 6 HD SHL160 6A HD SHL180 7 HD PIN001 8* RP SPT007 9 RP BRK1811 10* RP BRK0108 11* HD LEG9902 12* RP BCK0301 12A* RP BCK0304 12B* RP BCK0113 13* EL WIR469A 14* EL WIR1703 * = NOT SHOWN DESCRIPTION 6" CASTERS W/ BRAKE 6" CASTERS W/O BRAKE 4" CASTERS W/ BRAKE 4" CASTERS W/O BRAKE LOUVER, HINGED LOUVER, HINGED LOUVER, HINGED LOUVER MAGNET BUMPER, RUBBER SHROUD, COND UNIT SHROUD, COND UNIT SHROUD, COND UNIT SHELF 19" X 25" SHELF 22" X 25" SHELF SUPPORT PIN SHELF SUPPORT LOUVER MOUNTING HINGE BRACKET SHELF SUPPORT BETWEEN DOORS 6" LEG W/ BULLET FOOT S/S BACK PANEL 48" S/S BACK PANEL 60" S/S BACK PANEL 72" CORD, 14 GA 18" FEMALE 000469-14 POWER CORD, 9' 16/3 W/90*-45* ANGLE PLUG (SJTO WIRE) 9 OM-8000 & 9000W SERIES PREP TABLES XXX XXX XXX XXX X--X--X XXX XXX X--X--X X-X -XXXX XXX XXX -XX XXX X--X--X XXX XXX FAN ASSIST CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 ITEM SERVICE PART 1 RP FAN1801 2 RF FAN1401 3 RF FAN0703 * = NOT SHOWN FAN ASSIST ASSY FAN ASSIST MOTOR FAN ASSIST FAN GUARD 10 OM-8000 & 9000W SERIES PREP TABLES DESCRIPTION - - - -XX- -X - - - -XX- -X - - - -XX- -X MECH COMPARTMENT SINGLE COMPRESSOR CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 9148W-290 9260W-290 9272W-290 ITEM SERVICE PART DESCRIPTION 1 RF CMP1702 COMPRESSOR, 1/3HP, R290, EMBRACO FFU130UAX 2* RF CMP1702SC COMPRESSOR, START COMPONENTS 3 RP CAP1801 CAP, TUBE - RAIL 4 RF FAN1401 CONDENSER FAN 5 RF FAN0703 FAN GUARD 6 RF FLT251 FILTER DRIER, 1/4" DBL INLET 7 RP BRK1720 MOUNTING CLIP, FILTER DRIER (T07-1167) 8 RF SOL9801 SOLENDOID VALVE 9 RP BRK1812 BRACKET, SOLENOID VALVE (T07-1173) 10 RF ACM1702 ACCUMULATOR 11 RP MNT1802 COMPRESSOR ASM STAND 12 RF COI1603 CONDENSER COIL 13 RP SHD1809 CONDENSER FAN SHROUD (T07-1179) 14 RP CPN1802 DRAIN PAN - (T07-1146) 15 HD WCK1702 PAD, WICKING 16* EL WIR470 POWER CORD, 16GA 2' MALE * = NOT SHOWN 11 OM-8000 & 9000W SERIES PREP TABLES XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX XXX- - -XX-XXX MECH COMPARTMENT DOUBLE COMPRESSOR CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 ITEM SERVICE PART DESCRIPTION 1 RF CMP1604 COMPRESSOR, 1/4 HP, R290, EMBRACO, 115V-60HZ 2* RF CMP1604SC COMPRESSOR, START COMPONENTS 3 RP CAP1802 CAP, TUBE - RAIL 4 RF FAN0601 CONDENSER FAN 5 HD GRD1610 FAN GUARD 6 RF FLT251 FILTER DRIER, 1/4" DBL INLET 7 RF ACM1701 ACCUMULATOR 8 RP MNT1803 COMPRESSOR ASM STAND (T07-1168) 9 RF COI1603 CONDENSER COIL 10 RP SHD1810 CONDENSER FAN SHROUD (T07-1169) 11 RP CPN1803 DRAIN PAN (T07-1170) 12 EL WIR274 HEATER, DRAIN PAN 13* EL WIR470 POWER CORD, 16GA 2' MALE * = NOT SHOWN 12 OM-8000 & 9000W SERIES PREP TABLES - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X - - -XXX- -X EVAPORATOR COIL CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 ITEM SERVICE PART 1 RF COI107 EVAPORATOR COIL 2 RP CAP1804 CAP, TUBE - BASE 2A RP CAP1803 CAP, TUBE - BASE 3 RF FAN1401 FAN, EVAPORATORS 4 RP DRP107 EVAPORATOR DRAIN PAN 5 RP PNL107-290 SIDE, COIL, 8000N COMMON 6 RP PNL108-290 BACK, COIL, 8000N COMMON 7 RP PNL109-290 FRONT, COIL, 8000N COMMON 8 RP SHD1811 PLATE, FAN, 8000N COMMON 9 RP PNL1804 SIDE, COIL, NO PERF, 8000N COMMON * = NOT SHOWN DESCRIPTION 13 OM-8000 & 9000W SERIES PREP TABLES XXXXXXXXX - - -XXX- -X XXX- - -XXXXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX X-----X-- EVAPORATOR COIL CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 9148W-290 9260W-290 9272W-290 ITEM SERVICE PART 1 RF COI107 EVAPORATOR COIL 2 RP CAP1803 CAP, TUBE - BASE 3 RF FAN1401 FAN, EVAPORATORS 4 RP DRP107 EVAPORATOR DRAIN PAN 4A RP DRP107S EVAPORATOR DRAIN PAN/STAINLESS STEEL 5 RP PNL107-290 SIDE, COIL, 8000N COMMON 6 RP PNL108-290 BACK, COIL, 8000N COMMON 7 RP PNL109-290 FRONT, COIL, 8000N COMMON 8 RP SHD1811 PLATE, FAN, 8000N COMMON 9 RP PNL1804 SIDE, COIL, NO PERF, 8000N COMMON * = NOT SHOWN 14 OM-8000 & 9000W SERIES PREP TABLES DESCRIPTION XXX XXX XXX XXX XXX XXX XXX XXX XXX X-- DOOR ASSEMBLY CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 ITEM SERVICE PART 1 RF DOR0321 1A RF DOR0320 1B RF DOR0323 1C RF DOR0322 1D RF DOR0324 1E RF DOR0325 2* IN GSK9902 2A* IN GSK1025 2B* IN GSK1030 3 HD HDL0103 4 RP HNG9900 4A RP HNG026 4B RP HNG027 4C RP HNG023 4D RP HNG034 4E RP HNG035 5* HD BSH050 6* RP HNG025 * = NOT SHOWN DESCRIPTION DOOR HINGED LEFT, 21" DOOR HINGED RIGHT, 21" DOOR HINGED LEFT, 24" DOOR HINGED RIGHT, 24" DOOR HINGED LEFT, 27" DOOR HINGED RIGHT, 27" GASKET, 18.5" X 24.5" PUSH IN GASKET, 21.75" X 24.5" PUSH IN GASKET, 24.5" X 24.5" PUSH IN DOOR HANDLE (recessed) HINGE ASSY, UNIVERSAL, LEFT/RIGHT HINGE, STRAP L BRACKET TOP/BOTTOM HINGE, BOTTM l BRACKET W/ COLLOR HINGE, TOP L BRACKET W/O HINGE, TOP DOOR LH CHANNEL HINGE, TOP DOOR RH CHANNEL BUSHING, NYLON DOOR HINGE, SPRING LOAD ASSEMBLY 15 OM-8000 & 9000W SERIES PREP TABLES ---X-X-----X-X---X-X-X---X-X-X--X-X-X-X-X X-X-X-X-X ---X-X---X-X-X--X-X-X-X-X XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX DOOR ASSEMBLY CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 9148W-290 9260W-290 9272W-290 ITEM SERVICE PART 1 RP DOR0323 1A RP DOR0322 1B RP DOR0324 1C RP DOR0325 2 IN GSK1025 2A IN GSK1030 3 HD HDL0103 4 RP HNG9900 4A RP HNG026 4B RP HNG027 4C RP HNG023 4D RP HNG034 4E RP HNG035 5* HD BSH050 6* RP HNG025 * = NOT SHOWN DOOR HINGED LEFT, 24" DOOR HINGED RIGHT, 24" DOOR HINGED LEFT, 27" DOOR HINGED RIGHT, 27" GASKET, 21.75" X 24.5" PUSH IN GASKET, 24.5" X 24.5" PUSH IN DOOR HANDLE (recessed) HINGE ASSY, UNIVERSAL, LEFT/RIGHT HINGE, STRAP L BRACKET TOP/BOTTOM HINGE, BOTTM l BRACKET W/ COLLOR HINGE, TOP L BRACKET W/O HINGE, TOP DOOR LH CHANNEL HINGE, TOP DOOR RH CHANNEL BUSHING, NYLON DOOR HINGE, SPRING LOAD ASSEMBLY 16 OM-8000 & 9000W SERIES PREP TABLES DESCRIPTION -X-XX-X X-X -XX-X XXX XXX XXX XXX XXX XXX XXX XXX XXX DRAWER ASSEMBLY CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 ITEM SERVICE PART 1 RP DRW0206 DRAWER ASSEMBLY - 21" 1A RP DRW0201PT DRAWER ASSEMBLY - 24" 1B RP DRW0202 DRAWER ASSEMBLY - 27" 2 RP MOD050A DRAWER CARTRIDGE - 21" 2A RP MOD030A DRAWER CARTRIDGE - 24" 2B RP MOD029A DRAWER CARTRIDGE - 27" 3 RF FRT9903 DRAWER FRONT - 21" 3A RF FRT9904 DRAWER FRONT - 24" 3B RF FRT9905 DRAWER FRONT - 27" 4 RP FRM0301 DRAWER FRAME - 21" 4A RP FRM0302 DRAWER FRAME - 24" 4B RP FRM0303 DRAWER FRAME - 27" 5* IN GSK9903 DRAWER GASKET - 18.75" 5A* IN GSK1041 DRAWER GASKET - 21.75" 5B* IN GSK1046 DRAWER GASKET - 24.75" 6 RP TRK05SM DRAWER TRACKS (1L & 1R) 7 HD HDL130 DRAWER HANDLE 8 HC BRG210 DRAWER BEARING 9* FA SCW5002 DRAWER BEARING BOLT * = NOT SHOWN 17 OM-8000 & 9000W SERIES PREP TABLES DESCRIPTION ---X-X---X-X-X--X-X-X-X-X ---X-X---X-X-X--X-X-X-X-X ---X-X---X-X-X--X-X-X-X-X ---X-X---X-X-X--X-X-X-X-X ---X-X---X-X-X--X-X-X-X-X XXXXXXXXX XXXXXXXXX XXXXXXXXX XXXXXXXXX DRAWER ASSEMBLY CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 9148W-290 9260W-290 9272W-290 ITEM SERVICE PART 1 RP FRT0304 1A RP FRT0306 2 RP FRT0303 2A RP FRT0305 3 HD HDL0130 4 RP TRK05SM 5* IN GSK1042 5A* IN GSK1043 5B* IN GSK1048 5C* IN GSK1047 6 RP MOD1701A 6A RP MOD1603A 7 RP FRM0103 7A RP FRM127E 8 HD BRG210 9* FA SCW5002 7 HD HDL130 8 HC BRG210 9* FA SCW5002 * = NOT SHOWN DRAWER FRONT - BOTTOM - 24" DRAWER FRONT - BOTTOM - 27" DRAWER FRONT - TOP - 24" DRAWER FRONT - TOP - 27" DRAWER HANDLE DRAWER TRACKS (1L & 1R) DRAWER GASKET - 24" Top DRAWER GASKET - 24" Bottom DRAWER GASKET - 27" Top DRAWER GASKET - 27" Bottom DRAWER CARTRIDGE - 24" DRAWER CARTRIDGE - 27" DRAWER FRAME - 24" DRAWER FRAME - 27" DRAWER BEARING DRAWER BEARING BOLT DRAWER HANDLE DRAWER BEARING DRAWER BEARING BOLT 18 OM-8000 & 9000W SERIES PREP TABLES DESCRIPTION -XX-X -X--XXX XXX -X-XX-X X-X -XX-X -XX-X XXX XXX XXX XXX XXX DRAIN ASSEMBLY CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 9148W-290 9260W-290 9272W-290 ITEM SERVICE PART 1 PB VLV1803 2 PL TBG1801 3 HD CLM1801 4 HD CLP1902 5 PB ELB1801 6 EL GRM1801 7 HD DRN1702 * = NOT SHOWN DESCRIPTION VALVE, GREEN BACK, 25 MM TUBING, 1" VINYL, BLACK CLAMP, 1-1/4" OETIKER CLIP, SPRING, 1 TO 1-7/8 NICKEL PLATED STEEL ELBOW, 90 DEG GROMMET, PUSHON, DRAIN ASSY DRAIN, ABS, GRAY, 1.375", 1.00" NPS X 2.875" LG W/NUT & WASHER 19 OM-8000 & 9000W SERIES PREP TABLES XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX RAIL ASSEMBLY - NARROW HOOD COVER CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 ITEM SERVICE PART 1* HD PIN107 PIN, THREADED SOUTHCO 2* HD PIN107I INSERT, THREADED SOUTCHO 3* HD PIN001 PIN, KEY PAN RAIL 4 RP DSN001 DRAIN SCREEN, 2" 5 RP HNG006 HINGE, PAN COVER SET OF 2 6 HD PIN0101 PIN, LOCATING 0.875 LENGTH 7 FA NUT0403SS NUT, 1/4-20 CAP NUT 18-8 SS 8 RP PCR0115 COVER, HINGED PAN 8A RC PCR0117 COVER, HINGED PAN 8B RC PCR0118 COVER, HINGED PAN 8C RC PCR0114 COVER, HINGED PAN 8D RC PCR0115 COVER, HINGED PAN 8E RC PCR0116 COVER, HINGED PAN * = NOT SHOWN 20 OM-8000 & 9000W SERIES PREP TABLES DESCRIPTION XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX X-----X-----X-----X-----X-----X RAIL ASSEMBLY - WIDE HOOD COVER CALL FACTORY FOR REPLACEMENT PARTS: 888-994-7636 Parts List 8148N-290 8260N-290 8268N-290 8383N-290 8395N-290 84111N-290 8148W-290 8268W-290 8395W-290 9148W-290 9260W-290 9272W-290 ITEM SERVICE PART 1 RP HOD0101 1A RPHOD1801 1B RP HOD0301 1C RP HOD0202 1D RP HOD1802 1E RP HOD0407 1F RP HOD0310 1G RP HOD1803 1H HP HOD0609 2 HD ROD100 2A HD ROD200 3* HD PIN107 4* HD PIN107I 5* RP DSN001 6 RP LID048 6 RP HNG017 6A RP LID1502 6B RP LID068 6C RP LID083 6D RP LID095 6E RP LID111 6F RP LID1801 6G RP LID1802 6H RP LID1803 7* HD PIN001 * = NOT SHOWN DESCRIPTION HOOD COVER HOOD COVER HOOD COVER HOOD COVER HOOD COVER HOOD COVER HOOD COVER HOOD COVER HOOD COVER HOOD COVER, ROD W/ SINGLE BEND HOOD COVER, ROD W/ DOUBLE BEND PIN, THREADED SOUTHCO INSERT, THREADED SOUTCHO DRAIN SCREEN, 2" COVER (IMAGE ON LEFT) SLIDE BACK COVER (IMAGE ON RIGHT) COVER COVER COVER COVER COVER COVER COVER COVER PIN, KEY PAN RAIL 21 OM-8000 & 9000W SERIES PREP TABLES X--------X-- ------X---X- -X---------X --X--------- -------X---- ---X ------- ----X------- --------X--- -----X------ X- - -X-X-XX- - ----X---X--- XXXXXXXXXXXX XXXXXXXXXXXX XXXXXXXXXXXX X----------- - - - - - - - - -XXX -X--------X- --X--------X ---X-------- ----X------- -----X------ ------X----- -------X---- --------X--- - - - - - -XXX- - - 8000-290 SINGLE COMPRESSOR CAREL Wiring Diagram 16 - WHITE POWER SUPPLY 115V-60HZ-1PH CORD WITH GROUNDED CAP EL WIR461-90 NEMA G 5-15P PLUG GREEN 16 - BLACK 16 - BROWN 18 - BLACK 18 - BLUE 18 - BLACK 16 - WHITE 16 - BROWN 18 - BLACK 18 - BLUE 18 - BLACK 16 - WHITE 16FLA(96LRA) RAIL CONTROL 16(10)A 240V~ 16A 123456 7 COMP 16FLA(96LRA) 16(10)A 240V~ BASE CONTROL 16A 123456 7 COMP SENSOR CONNECTIONS 10K NTC RAIL 8 9 10 11 BASE 8 9 10 11 RAIL SENSING TUBE CONDENSER AIR (OPTION) COMPRESSOR COIL CONDENSER (DEF) (OPTION) 16 - BLACK 16 - WHITE 16 - BROWN EL WIR470 NEMA 5-15 EL WIR469A 16 - BLACK BLACK FAN #1 CONDENSER BLACK CONDENSER 16 - WHITE 16 - WHITE BLACK FAN #2 BLACK 16-WHITE 18 - BLUE 18 - BLUE 18 - BLACK 16 - WHITE 18 - BLUE RAIL SOLENOID 18 - BLUE 18 - BLUE BASE SOLENOID 18 - BLUE 18 - BLUE 18 - BLACK 18 - BLACK 18 - BLUE EVAP FAN #1 EVAP FAN #2 EL WIR0005 18 - WHITE 18 - WHITE 18 - GREEN 18 - GREEN 16-WHITE 22 OM-8000 & 9000W SERIES PREP TABLES 8000-290 DOUBLE COMPRESSOR CAREL Wiring Diagram POWER SUPPLY 115V-60HZ-1PH CORD WITH GROUNDED CAP NEMA # 5-15P NEMA G 5-15 PLUG 16FLA(96LRA) RAIL CONTROL 16(10)A 240V~ 16A 123456 7 COMP 35 GREEN 16-BROWN 16-BLACK 18-BLUE 16-BLACK 16-WHITE 16-BROWN 18-BLACK 18-BLUE 18-BLACK 16-WHITE 16FLA(96LRA) 16(10)A 240V~ BASE CONTROL 16A 123456 7 SENSOR CONNECTIONS 10K NTC RAIL 8 9 10 11 BASE 8 9 10 11 COMP RAIL SENSING TUBE CONDENSER AIR (OPTION) COIL CONDENSER (DEF) (OPTION) 16-BROWN BASE COMPRESSOR 16-WHITE 16-WHITE 18-BLUE CONDENSER FANS RAIL BASE 18-BLUE 18-BLUE 16-WHITE 18-BLACK 16-WHITE 1 2 (OPTIONAL TIMER) TIMER 16 - WHITE 16-WHITE 16-BROWN RAIL COMPRESSOR 18-BLACK COND HTR 16-WHITE 16-WHITE EVAP FAN #1 18-BLACK 16-WHITE EVAP FAN #2 18-BLACK 16-WHITE (OPTIONAL LED LIGHT) 16-WHITE 18-BLACK 16-WHITE FAN ASSIST OPTION ONLY 23 OM-8000 & 9000W SERIES PREP TABLES 9000W-290 CAREL Wiring Diagram 16 - WHITE POWER SUPPLY 115V-60HZ-1PH CORD WITH GROUNDED CAP EL WIR461-90 NEMA G 5-15P PLUG GREEN 16 - BLACK 16 - BROWN 18 - BLACK 18 - BLUE 18 - BLACK 16 - WHITE 16 - BROWN 18 - BLACK 18 - BLUE 18 - BLACK 16 - WHITE 16FLA(96LRA) RAIL CONTROL 16(10)A 240V~ 16A 123456 7 COMP 16FLA(96LRA) 16(10)A 240V~ BASE CONTROL 16A 123456 7 COMP SENSOR CONNECTIONS 10K NTC RAIL 8 9 10 11 BASE 8 9 10 11 RAIL SENSING TUBE CONDENSER AIR (OPTION) COMPRESSOR COIL CONDENSER (DEF) (OPTION) 16 - BLACK 16 - WHITE 16 - BROWN EL WIR470 NEMA 5-15 EL WIR469A 16 - BLACK BLACK FAN #1 CONDENSER BLACK CONDENSER 16 - WHITE 16 - WHITE BLACK FAN #2 BLACK 16-WHITE 18 - BLUE 18 - BLUE 18 - BLACK 16 - WHITE 18 - BLUE RAIL SOLENOID 18 - BLUE 18 - BLUE BASE SOLENOID 18 - BLUE 18 - BLUE 18 - BLACK 18 - BLACK 18 - BLUE EVAP FAN #1 EVAP FAN #2 EL WIR0005 18 - WHITE 18 - WHITE 18 - GREEN 18 - GREEN 16-WHITE 24 OM-8000 & 9000W SERIES PREP TABLES 8000-290 SINGLE COMPRESSOR DANFOSS Wiring Diagram 25 OM-8000 & 9000W SERIES PREP TABLES 8000-290 DOUBLE COMPRESSOR DANFOSS Wiring Diagram 26 OM-8000 & 9000W SERIES PREP TABLES 9000W-290 DANFOSS Wiring Diagram 27 OM-8000 & 9000W SERIES PREP TABLES Model No: Serial No: Date Purchased: Purchase Order No: Date Service Log Purchased From: Location: Date Installed: For Service Call: Maintenance Performed Performed By 28 OM-8000 & 9000W SERIES PREP TABLES