Owner's Manual for POTTER models including: CSPKSTR-24 Indoor Low Profile Wall Mount Colored Speaker Strobe Series, CSPKSTR-24, Indoor Low Profile Wall Mount Colored Speaker Strobe Series, Mount Colored Speaker Strobe Series, Speaker Strobe Series
Potter CSPKSTR-24 Series Low Profile Wall Mount Colored Speaker Strobe - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 3 Pages, 2.09MB
DocumentDocumentFeatures · 24VDC fixed 15/75 candela strobe · Lens colors available: amber, blue, green, and red · Amber versions come with ALERT wording · Speaker voltage 25 or 70.7 VRMs standard, field selectable · Field selectable power taps: 1/8W, 1/4W, 1/2W, 1W, 2W, 4W · Xenon strobe maintains constant flash rate (1Hz) · High quality dBA output (intelligible) · Frequency range 400-4000 Hz · Screw Terminals, separate in/out wiring (18-12 gauge) · Tamperproof grill · Faceplate available in red or off-white · Product includes a 5 year warranty CSPKSTR-24 Indoor Low ProfilSepWeaaklel rM/SoturnotbCeoSleorrieeds Application The Potter CSPKSTR-24 is an indoor wall mount, low profile, field adjustable speaker/strobe that offers a quality speaker and visual signals. Applications include severe weather, evacuation, emergency response and many more. Description The CSPKSTR-24 Series offers a 24VDC, fixed 15/75 candela strobe in lens colors of amber, blue, green, and red. The CSPKSTR-24 provides a 25 or 70.7 VRMs speaker with field selectable power taps of 1/8W, 1/4W, 1/2W, 1W, 2W, or 4W. The strobes can be synchronized using the Potter AVSM Synchronization Control Module, FACP, or power supplies that produce a Gentex Synchronization Protocol. The CSPKSTR-24 can be mounted to a 4" X 2 1/8" deep back box without an extension ring or using Potter SPKRBB surface back box. The CSPKSTR-24 grills are constructed of high impact textured plastic. S2657 7320-0328:0206 Product Listings · ANSI/UL 1480 and ANSI/UL1638 · CSFM 7320-0328:0206 Product Compliance · Americans with Disabilities Act (ADA) · NFPA 72 · IBC/IFC/IRC Technical Specifications Speaker Operating Voltage Strobe Operating Voltage Synchronization Module Environmental Limitations Unit Dimensions Back Box Shipping Weight 25VRMs or 70.7VRMs 16-33VDC Potter AVSM 32°F to 120°F Indoor Only 6.1" (15.494cm) square X 1.88" (4.7752cm) deep 4" X 2 1/8" deep box or Potter SPKRBB surface back box 1.5 lbs. Potter Electric Signal Company, LLC · St. Louis, MO · Tech Support: 866-956-1211 / Customer Service: 866-572-3005 · www.pottersignal.com 8830059 - REV B · 10/14 PAGE 1 OF 3 firealarmresources.com CSPKSTR-24 Indoor Low ProfilSepWeaaklel rM/SoturnotbCeoSleorrieeds CSPKSTR-24 Colored Lens Strobe Current Ratings Lens Color 15/75CD 24VDC UL Max Amber 148mA Blue 280mA Green 360mA Red 397mA Input Watts 1/8 1/4 1/2 1 2 4 Speaker dBA @ 10 ft. 25 Volts 74.6 dBA 77.7 dBA 80.5 dBA 83.1 dBA 85.6 dBA 87.9 dBA 70.7 Volts 73.7 dBA 76.7 dBA 79.6 dBA 82.5 dBA 85.4 dBA 87.9 dBA NOTE: · Potter does not recommend using a coded or pulsing signaling circuit with any of our strobe products. · The CSPKSTR-24 Colored Lens Series is not listed for outdoor use. Colored Lens Speaker/Strobes Model Number Description CSPKSTR-24AR Alert Amber Speaker/Strobe CSPKSTR-24AW Alert Amber Speaker/Strobe CSPKSTR-24BR Plain Blue Speaker/Strobe CSPKSTR-24BW Plain Blue Speaker/Strobe CSPKSTR-24GR Plain Green Speaker/Strobe CSPKSTR-24GW Plain Green Speaker/Strobe CSPKSTR-24RR Plain Red Speaker/Strobe CSPKSTR-24RW Plain Red Speaker/Strobe Stock Number 4890230 4890231 4890224 4890225 4890226 4890227 4890228 4890229 Model Designations W = Off-White Faceplate R = Red Faceplate Plain units are non-returnable Architect and Engineering Specifications The alarm speaker shall be Potter CSPKSTR-24 Colored Lens Series or equivalent. The speaker shall be capable of producing alarm tones or voice on all 25 or 70.7 VRMs audio systems. The speaker shall provide incremental tap settings of 1/8, 1/4, 1/2, 1, 2, or 4 watts. Minimum dBA ratings at 1/4 watt shall be 76.7 dBA and at 4 watts 87.9dBA. Tap settings shall be adjustable with field selectable jumper pins. The speaker shall also have an optional visual signal capability. The visual signal shall have a 1 Hz flash rate regardless of input voltage. All field wiring connections shall be made via separate in-out terminal connections and the speaker or speaker strobe shall be ANSI/UL listed and comply with all local, state and federal fire alarm codes/standards. Potter Electric Signal Company, LLC · St. Louis, MO · Tech Support: 866-956-1211 / Customer Service: 866-572-3005 · www.pottersignal.com 8830059 - REV B · 10/14 PAGE 2 OF 3 firealarmresources.com Power Tap Selection CSPKSTR-24 Indoor Low ProfilSepWeaaklel rM/SoturnotbCeoSleorrieeds Mounting Diagram Wiring Diagram NOTE: DO NOT USE LOOPED WIRE UNDER TERMINALS. BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTION. · MAX WIRE DISTANCE - PANEL VOLTAGE - DEVICE MINIMUM VOLTAGE - X WIRE CONDUCTIVITY TOTAL CURRENT DRAW · CAUTION: APPLIES ONLY TO REGULATED SUPPLIES. · NOTICE: POWER IS SUPPLIED TO DEVICES WHEN CONTROL PANEL IS LATCHED. Potter Electric Signal Company, LLC · St. Louis, MO · Tech Support: 866-956-1211 / Customer Service: 866-572-3005 · www.pottersignal.com 8830059 - REV B · 10/14 PAGE 3 OF 3 firealarmresources.com