User Manual for DATAKOM models including: DKM-250 DC Energy Analyzer and Earth Leakage Detector, DKM-250, DC Energy Analyzer and Earth Leakage Detector, Earth Leakage Detector, Leakage Detector
DKM-250 DC - Datakom Power
DKM-250 DC ENERGY ANALYZER & EARTH LEAKAGE DETECTOR DESCRIPTION The DKM-250 is a precision instrument designed for measuring, displaying and remote monitoring earth leakage and various DC parameters in a DC distribution box. The unit features a 32-bit ARM core microcontroller. The unit is supplied from the measuring DC voltage input. Operating range is between 19 and 270VDC. The current input of the unit is isolated from the rest of the circuit and has different circuit options: External current shunt (standard) Internal current shunt Hall Effect sensor input 4-20mA analog input The unit has 2 digital inputs and 2 relay outputs, both of them programmable for required functions. Thanks to its isolated RS-485 Modbus RTU comport, the device is free from ground potential difference issues and data are safely transferred to automation and monitoring systems. Program parameters may be uploaded to the unit through the RS485 port. The unit may output any measured value as analog signal through its 4-20mA port. This output allows easy connection to PLC systems. FEATURES Displays earth leakage in % Various current input options 2 programmable relay outputs 2 programmable digital inputs Programmable 4-20mA analog output Demand, Min & Max records Fully isolated RS-485 serial port MODBUS-RTU communications Bidirectional current & power measurement Bidirectional kW-h energy counter Bidirectional A-h counter Hours run counter Front panel programming Wide operating temperature range Sealed front panel (IP65 with gasket) Two part connection system CONNECTION DIAGRAM INSTALLATION TECHNICAL SPECIFICATIONS Supply Input: 19-270VDC Power Consumption: < 4W Voltage Measurement Input: Measurement range: 0-300V Accuracy: 0.5% Current Measurement Input: Measurement range: -100mV to +100mV. Accuracy: 0.5% Isolation: 1000V AC, 1 minute Internal Current Shunt Option: Measurement range: 0-15A Analog Output: 0-20mA Analog Output Precision: 16 bit Digital Input Range: 19 to 270VDC Relay Outputs: 5 Amps @ 28VDC Serial Port: Signal type: RS-485 Protocol: Modbus RTU Data Rate: 2400-38400baud Isolation: 1000V AC, 1 minute Operating Temp. Range: -20°C...+70 °C (-4°F...158°F) Max. Relative Humidity: %95 non-condensing Protection Degree: IP 65 (Front panel, w. gasket) IP 30 (Back panel) Enclosure: Flame retardent, ROHS compliant high temperature ABS/PC (UL94-V0) Installation: Flush mounting with rear brackets Dimensions: 102x102x53mm (WxHxD) Panel Cutout: 92x92mm Weight: 200 gr EU Directives: 2014/35/EC (LVD) 2014/30/EC (EMC) Reference Standards: EN 61010 (safety) EN 61326 (EMC) PANEL CUTOUTMicrosoft Word 2019