EAF-350. PARTS LIST—EAF-350 FAUCETS. Item No. Code No. Part No. Description 1. 0335040 EAF-60 Cover 2. 0335043 EAF-61 Cover Clip – Battery Support 3. 3324166...
Sloan EAF 350 Repair Parts | Air Delights
File Info : application/pdf, 2 Pages, 448.51KB
DocumentDocumentEAF-350-ISM EAF-350 1 2 3 4A 4B 5A 5B 11 6 7 8 9 10 Repair Parts and Maintenance Guide Optima® EAF-350 PARTS LIST--EAF-350 FAUCETS Item No. Code No. Part No. Description 1. 0335040 EAF-60 Cover 2. 0335043 EAF-61 Cover Clip Battery Support 3. 3324166 EFX-1015-A Battery Replacement Kit (with 2.5 mm hex key) 4A. 0335021 EAF-22 1.5 gpm (5.6 Lpm) AER Spray Head 4B. 0335036 EAF-63 0.5 gpm (1.9 Lpm) AER Spray Head 5A. 3335116 EAF-1021-A Electronic Sensor (15 Second Shut-off) with Fixing Clip Kit (0.5 gpm only) 5B. 3335113 EAF-1018-A Electronic Sensor (7 Second Shut-off) with Fixing Clip Kit (1.5 gpm only) 6. 3335114 EAF-1019-A Mixer Handle Assembly and Cartridge Kit 7. 0335001 EAF-2 Solenoid Valve Cartridge (IQ Faucet) 8. 0335115 EAF-1020-A Handle Repair Kit 9. 0335006 EAF-8 Back Check (2 required for ISM models) 10. 0335000 EAF-1 Faucet Mounting Kit 11. 3335023 EAF-1008 13" (330 mm) Flexible Supply Hose (1) (2 required for ISM models) 12. 0335007 EAF-9 Filter (2 required for ISM models) 13. 0362011 SFP11 4" Trimplate 14. 3362022 SFP-22 8" Trimplate IR-Click Settings Function Press Button LED Signal Temporary OFF (2 min) 1. 1 time for 2 seconds 2. 2 times (double push) 1. LED Green (1) 2. LED Red pulsating flashes reset: 1 time or will reset automatically after 2 mins Continuous Run 1. 1 time for 2 seconds 1. LED Green (1) 2 minute default setup 2. 1 time for 3-5 seconds 2. Water flows after (adjustable from 1-20 mins) releasing reset: 1 time or will reset automatically after 2 mins Sensor Range Adjustment 1. 1 time for 2 seconds 2. 2 times (double push) 3. 1 time for 5 seconds then hold till requested range is reached 4. Release 1. LED Green (1) 2. LED Red blinks 3. LED Red (1-8) 4. LED Green (1) 12 14. 13. The information contained in this document is subject to change without notice. 222 Repair Parts and Maintenance Guide Optima® EAF-350 TROUBLESHOOTING GUIDE 1. Faucet DOES NOT function. A. "Permanent Off" activated. Press button on faucet throat one time. 2. Faucet delivers water in an uncontrolled manner. A. Faucet is not working properly. Contact Sloan Technical Support. 3. Faucet DOES NOT deliver any water when Sensor is activated. INDICATOR: Solenoid valve produces an audible "CLICK." A. Water supply stop(s) closed. Open water supply stop(s). B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s) if required. INDICATOR: Solenoid valve DOES NOT produce an audible "CLICK." A. Battery low (battery powered models). Replace battery (refer to Battery Replacement on page 184). 4. After removing label water does not flow. Use this installation guide as a target by placing it in front of the sensor (approx. 1-1/2" away) until water begins flowing, then remove installation instruction from sensor. Water will stop flowing, wait 10 seconds before using faucet. 5. Faucet delivers only a slow flow or dribble when sensor is activated. A. Water supply stop(s) are partially closed. Completely open water supply stop(s). B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s) if required. C. Aerator is clogged. Remove, clean, and reinstall Aerator. Replace Aerator if required. D. Faucet is not working properly. Contact Sloan Technical Support. 6. Faucet DOES NOT stop delivering water or continues to drip after user is no longer detected. A. Faucet is not working properly. Contact Sloan Technical Support. 7. LED indicator blinks when faucet is in use. A. Battery low (battery powered models). Replace battery. 8. The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines. A. Supply stops are not adjusted properly. Adjust supply stops. B. For models with integral mixing valve Mixing valve is set improperly for the water temperature desired. Rotate mixing valve handle clockwise to decrease water temperature or counterclockwise to increase water temperature. OPERATION As the user's hands enter the beam's effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet. Water will flow until the hands are removed or until the faucet reaches its automatic time out limit setting. CARE AND CLEANING DO NOT use abrasive or chemical cleaners (including chlorine bleach) to clean faucet that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom tile, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating. When assistance is required, please contact Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614). The information contained in this document is subject to change without notice. 223Adobe InDesign 15.0 (Macintosh) Adobe PDF Library 15.0