Instruction Manual for SECO-LARM models including: SD-6176-SSQ Outdoor Piezoelectric Request Exit Pushbuttons, SD-6176-SSQ, Outdoor Piezoelectric Request Exit Pushbuttons, Piezoelectric Request Exit Pushbuttons, Request Exit Pushbuttons, Exit Pushbuttons, Pushbuttons

SECO-LARM ENFORCER SD-6176-SSQ (01) PDF MANUAL - Manual-Hub.com


File Info : application/pdf, 4 Pages, 1.07MB

PDF preview unavailable. Download the PDF instead.

SECO-LARM ENFORCER SD-6176-SSQ (01)
Outdoor Piezoelectric Request-to-Exit Pushbuttons
Manual

SD-6176-SSQ SD-6176-SS1Q SD-6176-SSVQ SD-6276-SSQ SD-6276-SS1Q SD-6276-SSVQ

Slimline plate, "TOUCH/EXIT" Slimline plate, "EXIT/SALIDA" Slimeline plate, manual override
Single-gang plate, "TOUCH/EXIT" Single-gang plate, "EXIT/SALIDA" Single-gang plate, manual override

Piezoelectric push buttons for indoor or outdoor use (IP65). LED ring around button changes from green to red or red to green when the button is pressed. Timed or toggle output.

Includes separate manual override button in case power to piezoelectric push button fails.
Relay rated 2A@30VDC with two individually programmable outputs (NO/NC).

Note: Products with model numbers that end with "Q" or that have a round green "Q" sticker are RoHS compliant.
https://manual-hub.com/

ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton

Specifications:

Operating voltage Current drain Contact rating Ring LED
Colors reversible v a switch
Output time IP rating Operating temperature Plate material
Weight

Standby Active
Single-Gang Single-Gang w/Manual
Override
Slimline Slimline w/Manual
Override

12~24 VDC 100mA@12VDC 2A@30VDC or 0.5A@125VAC
Red Green 1~30 s, Toggle IP65 32 ~158 F (0 ~70 C) Stainless steel 3.5-oz (99g)
4-oz (113g)
2.6-oz (74g)
3.1-oz (88g)

Parts List:
Piezoelectric push button ........................... 1 x Wires for manual override 1 ........................ 2 x

Mounting screws .................................. 2 x Manual ................................................. 1 x

Overview:

SD-6176-SSVQ and SD-6276-SSVQ with Manual Override button shown, other models similar.

Slimline
15/8" (42mm)

Single-Gang
23/4" (70mm)

Side View
15/8" (42mm)

Rear View
(Plastic switch cover removed)

Buzzer adjust

LED ring

Relay adjust

41/2" (114mm)

Piezoelectric pushbutton
Manual override button2

Terminal blocks
LED color selection
Output mode selection Timer adjustment
Manual override button2

Installation:

1. Prepare wiring to provide 12~24 VDC power and connect devices to the relay outputs.

Note: The device includes one relay with two outputs. Outputs trigger simultaneously but can be

configured independently. To set the output modes, see Relay Output Modes on page 3.

2. Remove the plastic cover from the rear of the switch and carefully pierce the rubber grommet.

3. SD-6176-SSVQ and SD-6276-SSVQ: Wire the manual override button. See page 3.

4. Wire the switch according to the diagram on the right.

Terminal Block

Connect (-) and (+) to a 12~24 VDC power source.

Connect other devices to Outputs 1 or 2.

5. Replace the plastic switch cover and screw the plate

onto the mounting surface.

1 SD-6176-SSVQ and SD-6276-SSVQ only.

2

SECO-LARM U.S.A., Inc

https://manual-hub.com/

ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton

Wiring the Manual Override: SD-6176-SSVQ and SD-6276-SSVQ Only
Connect the manual override button with the included wires.

Wiring For N.O.: Connect the two wires between the NO and COM terminals of the override button and the Output 1 or 2 terminals on the switch.

COM N.O.

Wiring For N.C.: Connect the two wires between the NC and COM terminals of the override button and the Output 1 or 2 terminals on the switch.

COM N.C.

Notes a. Remove the thin panel on the bottom of the plastic cover to allow wiring to pass through. b. There is only one relay, wiring the button to either output will allow the other output to trigger simultaneously. c. Do not connect the manual override button to more than one output. d. When wiring for either N.O. or N.C., be sure to also set the Relay Output Mode to N.O., as described below.
If Relay Output Mode and override button wiring do not match, the product may not function as expected.

Manual Override Button

Configuring the Pushbutton:
1. Buzzer Output

DEFAULT: ON

Use the buzzer output jumper JP3 to program the buzzer output. Placing the jumper on the left turns buzzer output ON. Placing the jumper on the right turns buzzer output OFF.

2. Relay Output Mode 3. LED Ring Colors

DEFAULT: N.O.
Outputs 1 and 2 can be set independently using jumpers JP1 and JP2. Note: Both outputs trigger simultaneously. Place the jumper on the right for N.O. operation and on the left for N.C. operation.
DEFAULT: OFF

ON: LED is green while in standby, and turns red when triggered. OFF: LED is red while in standby, and turns green when triggered.

4. Switch Output Type

DEFAULT: Timer
TIMER: When set to TIMER, pressing the switch will trigger the relay for the set time. Set the time using the trimpot as described above. TOGGLE: When set to TOGGLE, pressing the switch will cause the relay to trigger until the switch is pressed again.

5. Timer Adjustment

DEFAULT: 1s
Output duration is adjustable 1~30 seconds. (Must be set to `Timer' in step 4) Gently rotate the trimpot using a Philips head screwdriver. Counterclockwise decreases the output time. Clockwise increases the output time.

SECO-LARM U.S.A., Inc

3

https://manual-hub.com/

ENFORCER Outdoor Piezoelectric Request to Exit Pushbutton
Sample Installation: Electromagnetic Lock (Fail-Safe) with Strobe Light

ENFORCER LED Strobe Light

ENFORCER Electromagnetic Lock

Also Available from SECO-LARM:

Electromagnetic Locks

Request-to-Exit Plates

No-Touch Request-to-Exit

RF Wireless Request-to-Exit

WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM's obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect, repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM, and the purchaser's exclusive remedy, shall be limited to replacement or repair only, at SECO-LARM's option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential personal or property damages of any kind to the purchaser or anyone else.

NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.

Copyright © 2011 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in whole or in part, without the written permission of SECO-LARM. SECO-LARM ® U.S.A., Inc.

16842 Millikan Avenue, Irvine, CA 92606 Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
4

Website: www.seco-larm.com E-mail: sales@seco-larm.com

PIHWK1 MiSD-6x73-SSxQ_1111.docx

SECO-LARM U.S.A., Inc

https://manual-hub.com/



References